Model: LED100PIRWH - White Model: LED100PIRB - Black. Installation & Operating Instructions. Single Spot 8W LED Lighting with Motion Detection Sensor

Similar documents
5W LED Energy Saver PIR Bulkhead

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

OPERATING INSTRUCTIONS

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

Fused Spur Time Switch

LED MOTION ACTIVATED FLOOD LIGHT

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

LOS 2500 SUPER CEILING SENSOR. Installation Manual

LED MOTION ACTIVATED FLOOD LIGHT

PIR Motion Detector E-808

Infrarot-Bewegungsmelder IP44

Wireless 7 Day Programmable Room Thermostat

INFRARED QUARTZ WALL HEATER

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

REDWALL-V adjustment procedures guide

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

LED Security Spotlight User Manual

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Die-Cast Metal, Motion- Activated Post Light

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

60W Security Twinspot. 754HB2/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Operating instructions IV / 2007

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

D/N VARI-FOCAL IR CAMERA

Operating instructions II / 2004

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cross-beam scanning system to detect slim objects. 100 mm in

(IR) Bullet LPR/ANPR Network Camera


Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Product and Application Description

Dome Camera with IR Night Vision

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Drayton Digistat +2RF/+3RF

High definition day/night

Dual Technology Ceiling Mount Sensor

Wireless Home Security Alarm System AM 500

Installation Instructions

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

ALARM SYSTEM INSTALLATION GUIDE

COLOR VIDEO DOOR PHONE CDV-71BE/D

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Product Catalogue August Energy management Switches and controls

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

1. Description. 2. List of Accessories included A B C F G H

ELECTRIC INSTANTANEOUS WATER HEATER

EBDSPIR-PRM, EBDSPIR-PRM-IP

Day / Night IR Color Camera User Manual V2.1.0

DALI RC BASIC SO. Control unit Operating instructions

Neuton Solar Power Diverter Quick Installation Guide

Building Technologies

Electrical Safety Tips. Help us keep you safe

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

ELECTRIC CENTRAL HEATING FLOW BOILER

Motion Activated Camera User Manual

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Color Mark Sensor with Red or Green LED E3S-VS

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Awning Instructions. Full Cassette 1.5m to 6m

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Video surveillance camera Installation Guide

12 Volt 30 Amp Digital Solar Charge Controller

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Operating Instructions Bedienungsanleitung Mode d emploi

Cable Plug acc. to DIN EN , Form A

Home Monitoring and Control service provided by Verizon Online LLC

Dome Security Camera with IR night vision

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

LIEBERT VNSA Installation Sheet

aseries A13B Mini Bullet Camera User Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

ACS-30-EU-EMDR-10-MOD

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

Introduction. Page 2 / 9

Owner s Manual

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Robust and waterproof

basicdim DGC Compact control module

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

AUTOMOTIVE LED LIGHT CATALOG

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

6 LED colours: White Blue Green Red Yellow Amber

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Security Camera Indoor/Outdoor Color Camera w/ Night Vision

Floodlight Range Installation Guide

ATL Fuel Level Sender Probes

Transcription:

Model: LED100PIRWH - White Model: LED100PIRB - Black Installation & Operating Instructions Single Spot 8W LED Lighting with Motion Detection Sensor

1. Designated Use LED100PIR is an outdoor motion detector for automatic LED lighting control. Suitable for installation on walls. Simple plug in wall plate for easy & safe connection. Suitable for a wide range of locations: corridors, gardens, staircases, entrances, garages, outdoor parking areas etc. 2. Basic Safety Instruction Danger of death through electric shock. Must only be installed by qualifi ed electricians. Avoid the metal parts of the device due to potentially high temperature. 1 The device conforms to EN60598 for designated installation; IP44 in accordance with EN 60598 and IEC62471 Photo biological safety of lamps and lamp system. Designed for use in normal environments. Intended for outdoor installation. Energy saving. Long LED bulb life. Index : Page 2 Contents, Tools required. Page 3 Product dimensions. Page 4 Installation procedure. Page 5 Sensor detection range. Page 6 Walk test & adjustment, Detector head adjustment. Page 7 Knob settings. Page 8 Lens masking. Page 9 Lamp adjustment, High temperature in lamp.

3. Contents: Whats in the box? x2 x2 x1 x1 x1 2 4. Tools Required: Tools/equipment needed for installation. x1 x1 x1

5. Product Dimensions: 22.00 81.00 75.00 182.80 3 80.00 47.50 61.50

6. Installation Procedure: Switch off the power. Twist-open the wall plate. 240V OFF Fix the wall plate to the wall. Ø5mm L N Mounting Screws x2 60mm 4 Feed the wires through rubber gasket of the wall plate and attach to corresponding terminal. Attach the device to the wall plate. L N L LIVE BROWN N NEUTRAL BLUE GREEN/ EARTH YELLOW Switch On the power. 240V ON Unit goes into warm-up period for 40 sec.

Installation Advise: As the detector responds to changes in temperature, avoid the following situation: Pointing the detector towards objects with highly reflective surfaces, such as mirrors etc. Mounting the detector near heat sources, such as heating vents, air conditioning units, lights etc. Pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc. ºC ºC ºC 40 40 40 5 Detection Range: LED100PIR: Recommended installation height is 2.5 meter above ground, the maximum detection range about 10 meter and at the angle of about 140 deg. 3M eter 1.8m to 2.5 Meter 3m 10m 10 M eter 140 º

Walk Test and Adjustment The purpose of Walk Test is used to test and adjust the detection coverage of LED100PIR under auto mode. Adjust the Time knob to T, then conduct a walk test as described in test procedure. Test procedure: Adjust the Time knob to T, (Lux knob can be Sun or Moon ). Switch power On. Walk across the detection area, once the detector is triggered and the lamp will turn On for 2 seconds. Note walking direction when performing test. 2 sec 6 Test mode Detector Head Adjustment The detector head can be panned 90 deg. to the left and 90 deg. to the right. 90º 90º

Knob Settings LED100PIR has two adjustment knobs: Time and Lux at the bottom of the detector head. Adjust knobs carefully with hand. TIME knob setting You can set the time knob from 5 sec to about 10 min, LED100PIR will turn On the lamp, for the time duration set after each detected movement. Adjust the knob as desired. LUX knob setting When setting the Lux knob at MOON, LED100PIR Single will only operate in the dark. When setting the Lux knob at SUN, LED100PIR will operate in any light level. 7 Turn On Time Adjustment 5 sec Environment LUX Level to Turn On 10 min Dusk Setting (Time knob setting) When setting the Time knob to D, the motion detector of LED100PIR won t function. The lamp will operate depending on the LUX level, ie Dusk to Dawn. =

Lamp turns On at night. Lamp turns On at day & night. Setting Advise Lens masking 8 The purpose of the lens mask is to mask out areas not desired for detection. Lens mask fitting procedure: Use a penknife or pliers to cut out lens mask segment, exposing area for detection. Attach the lens mask to the detector head. Turn slightly the lens mask for it to be locked into place. A B

Lamp Adjustment The lamp can be tilted down 85 deg. and pan outwardly 40 deg. 40º 9 85º High Temperature The temperature of the lamp is very high during operating. You will get hurt, if you touch the heat sink. 40 30 20 10 40 30 20 10 +40ºC -20ºC

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. 10

HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Designed in the U.K. 67-058-417 Zerofour August 2011 Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com