MODEL SL104C OUTDOOR MOTION SENSOR LIGHT

Similar documents
5W LED Energy Saver PIR Bulkhead

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

INFRARED QUARTZ WALL HEATER

Operating instructions IV / 2007

LED MOTION ACTIVATED FLOOD LIGHT

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Die-Cast Metal, Motion- Activated Post Light

PIR Motion Detector E-808

60W Security Twinspot. 754HB2/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

LED MOTION ACTIVATED FLOOD LIGHT

Infrarot-Bewegungsmelder IP44

LUCCI AIRFUSION QUEST II CEILING FAN

Operating instructions II / 2004

Portable Air Conditioner

EBDSPIR-PRM, EBDSPIR-PRM-IP

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Awning Instructions. Full Cassette 1.5m to 6m

LED Security Spotlight User Manual

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

HERZ-Thermal Actuators

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

3 IN 1 BATHROOM HEATER

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

LOS 2500 SUPER CEILING SENSOR. Installation Manual

Drayton Digistat +2RF/+3RF

EBDSPIR-DD, EBDSPIR-DD-IP

Ceiling Fan Installation Instructions

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

OPERATING INSTRUCTIONS

60 WATT LED TRIPLE BEAM WORKLIGHT

LED Par 56 Short DMX ORDERCODE 42421

Cross-beam scanning system to detect slim objects. 100 mm in

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Xenon HID Lighting System

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

FIRERAY 2000 Installation Guide

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

This icon denotes a situation involving the risk of serious injury or even death, if the warning given is ignored.

ACS-30-EU-EMDR-10-MOD

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

COLOR VIDEO DOOR PHONE CDV-71BE/D

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

2-SLICE COOL TOUCH TOASTER

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

DALI RC BASIC SO. Control unit Operating instructions

Radiant Temperature Sensor TY7321

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Wireless Home Security Alarm System AM 500

Dual Technology Ceiling Mount Sensor

Ducoterra Radiant Heating Panel Installation Manual

4.3-inch Back-Up Camera

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

ELECTRIC CENTRAL HEATING FLOW BOILER

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Accessory Manual Ventilation Section Model Comfort Circle

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

WE-350 Series ¼ Turn Electric Actuator

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

For installation guide see reverse of book

Odyssey of the Mind Technology Fair. Simple Electronics

Meaco 30L and Meaco 40L dehumidifier instruction manual

Single Channel Loop Detector

User Manual THR840DUK Digital Thermostat

Light Source User Guide

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

How To Use A Power Supply On A Powerline 2.2 (Ai)

Wireless 7 Day Programmable Room Thermostat

Instruction manual for Firstline FCS12000CH

Wind Sensor W-RS485 with RS485 Interface

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Stove Guard Kit User Manual

Transcription:

MODEL SL04C OUTDOOR MOTION SENSOR LIGHT SPECIFICATIONS. POWER : 0V - 40V ~ 50Hz.. 3 seconds to 0 minutes adjustable shut-off time. 3. 400 watts (MAX.) lighting load for halogen lights. 4.0 elliptical view field, metres forward. 5. Weather resistant. 6. LED Indication of PIR Stand-by and Activated Mode. FUNCTION & CONTROL.TIME( ) : Adjusts the infrared motion sensor s shut-off time. Light will remain on for the setting time interval after last motion is detected..lux( / ) : The light sensitivity adjustment allows you to easily set the light so that it won t go on during daylight. 3. SENS.: The detecting distance adjustment allows you to easily set the detecting distance. Passive infrared is more sensitive in winter than in summer, be sure to reduce the sensitivity knob counter-clockwise to avoid false triggering. Fig.

INSTALLATION Warning : If in doubt, the installation of the infrared motion sensor light should be carried out by a qualified electrician. Before you begin, please verify the contents of this package. It should contain the following parts: LIST PARTS NAME QUANTITY LIST PARTS NAME QUANTITY A Mounting Bracket H Rubber Washer B Halogen Light I Terminal Block C Screw A J Screw B D Shakeproof Washer K Fixed Plate E Spring Washer L Screw C F Nut M Earth / Ground Screw G Gland Fig.

. Turn off the power at the main fuse box in your home(see Fig. 3).. Fix metal bracket on the wall with Wood Screws (not included). 3. Fix halogen lamp to metal bracket with attached hardware. 4. Strip sheath and insulation of cable. Let conductors expose approximate 6 mm. 5. Open cover of connection box. Fig. 3 6. Lead power wire through attached grommet. 7. Connect wire to terminals as Fig. 4 8. Fix power cable (use plate. Ref K). 9. Close cover of connection box. SL04 CONNECTION DIAGRAM Connection box lid NOTE:. If more range is required, try pointing the motion sensor slightly upward, so that the 3rd Level of vision can monitor an area above your head.. Try to keep the quartz light as far away as possible from the motion sensor, as heat from the light may confuse the motion sensor. WARNING!! THIS UNIT MUST BE EARTHED Green & yellow wire LAMP Blue wire N Brown wire L 30v ac supply cable Pre wired connections to lamp & sensor CAUTION: PLEASE FOLLOW AC POWER CONNECTION LABEL MARKINGS. WRONG POWER CONNECTION WILL DESTROY THIS SENSOR UNIT. LOCATION SELECTION Fig. 4 Selecting A Location. When mounted at the recommended height of M, the detection pattern extends M. (see Fig. 5) 30v ac supply cable Cable clamp Connection box * THIS FITTING MUST BE EARTHED 9 T OP VI EW 6 3 0 0 3 6 9.0M SIDE VI EW 0 3 6 9 M Fig. 5 3

. Before mounting the sensor on the wall or ceiling, please refer the figures below to prevent INCORRECT installation. MOUNT ON STABLE SURFACE AIM SENSOR DOWNWARD TO REDUCE RANGE DON'T EXPOSE TO RAIN OR ROOF RUNOFF AVOID REFLECTED LIGHT FROM BRIGHT SURFACES MORE SENSITIVE TO MOVEMENT ACROSS FIELD THAN INTO FIELD POSITION SENSOR EXACTLY LEVEL FROM SIDE TO SIDE DON'T MOUNT ABOVE LAMPS OR NEAR AIR VENTS MAKE SURE LENS NEVER POINTS DIRECTLY AT THE SUN 4

Adjustments: Time : The detector has an adjustable Time ON control from 3 sec. minimum to a maximum of 0 minutes (approx). Timer starts working after the last movement is detected. While there is movement from a heat source in the detecting area the lighting will remain on and the time will keep resetting. LUX( / : The adjustment controls the sensitivity to the background light level at which the detector will operate automatically. It may be set to any level between 5 lux and full daylight. The unit will operate when it senses motion and the ambient light is at or below the chosen level. SENS. : The detecting distance adjustment allows you to easily set the detecting distance. Passive infrared is more sensitive in winter than in summer, be sure to reduce the sensitivity in winter by adjusting the SENS knob counter-clockwise to avoid false triggering. LED Indication of PIR Stand-by and Activated Modes: Internal LED indication (behind the lens) works with LUX / control. It will start blinking and detector will start reacting to motion objects when the ambient light level is lower than the detector s setting on LUX / control. It will remain On when detector is activated as long as the setting on Time control. NOTE: When the LED indication is Off, it means the ambient light level is higher than the detector s setting on LUX( / ) control and detector won t react to any motion objects. Initial Set-up & Operation: POWER OFF SWITCH ON AUTO MODE OFF-ON-OFF-ON QUICKLY PERMANENTLY ON MODE Auto Mode. Sequence Diagram. Switch on supply and the detector will commence a 30-sec warm up period, during which the lamp may turn on and off.. Turn the Time( ) control to minimum and the LUX( / ) control to maximum. 3. Walk in front of the detector until the light comes up. This checks the operation of the detector and the field of view. Once the light comes on, move to a new position and stand still until the light goes out, move again until the light comes on. 4. Repeat step 3 and adjust the angle of the detector until the optimum field of view is achieved. 5. Turn the Time( ) and LUX( / ) controls to the desired positions 6. The detector is now in Auto Mode and will operate according to the preset time and ambient light adjustments. AFTER HOURS OR POWER OFF-ON-ONCE (QUICKLY) 5

Lights Permanently Off: Turn the control switch OFF. Light Permanently ON (Manual Override): By flipping the connected power switch Off-On twice quickly, it will change from Auto Mode to PERMANENTLY ON Mode. The detector will return to Auto Mode i.e. light will go off automatically after two hours or by flipping power switch Off-On once instead. IMPORTANT: If you find the light permanently On accidentally (notby the above method), please switch power Off for 3 second or so and then switch power On again, it shall return to Auto Mode and work normally. Trouble Shooting:. Unit doesn t function at all / Lights don t come on - Check wiring to unit to make sure that you have correct AC power at the unit. - Check the wiring from the unit to the source of power to make sure you have wired the unit correctly. - Check the ambient light control if it was set at your desired level. Detector clicks but does not operate - Check lamps are not broken. - Check lamps tight in lampholders. 3. Lights go on and off quickly - Ensure light and heat are not being reflected back onto the detector. Check for white or reflective surfaces in protection pattern. - Note the detector is more sensitive in cold weather 4. Lights stay on - Check unit has not gone into Manual Override mode. - Light bulb sockets may be wired directly to the power source - Recheck the wiring diagram - Adjust time to minimum - Ensure unit is firmly fixed to a solid object with no moving branches etc. in field of view. - Ensure detector is not being activated by stray moving heat sources such as heating outlets, car etc. 5. Lights switch on during storms - Adverse weather conditions and temperature changes can result in unwanted activations. - This can be minimized by mounting in a protected location 6. Maintenance and repair - Do not attempt to repair as this could invalidate warranty or result in personal injury. - Clean detector lens and outside casing with damp cloth NOTE: This product is RoHS compliant 6

Due to our policy of continuous improvement we reserve the right to change specification without prior notice. Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be accepted by Challenger for any misinterpretation of these instructions. RoHS CHALLENGER SECURITY PRODUCTS 0 Sandersons Way, Marton, Blackpool, FY4 4NB Tel: 053 79888, Fax: 053 79887 Email: enquiries.challenger@adivision.co.uk Web: www.challenger.co.uk