CONSIDERATIONS WHEN SPECIFYING A TRANSFORMER

Similar documents
Transformer Design & Design Parameters

Presentation of the France Transfo factories

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

Electrical Maintenance Workshop


Multi-tap Transformers

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Primary and Secondary Electrical Distribution Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Power Plant Electrical Distribution Systems

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Transformer Manufacturing Processes

Distribution Voltage Regulators

ECOCIAT. Domestic hot water heat recovery unit

understanding medium frequency induction melting furnace and its components

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

REGULATORS 175/153 Series

Power Transformers 10 to 100 MVA

FLASH TANK ECONOMIZER PRODUCT GUIDE

TRANSFORMER DICTIONARY

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

Secondary Unit Substations

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

جامعة البلقاء التطبيقية

Boiler Plan II Table of Contents

Max. Length of HTS Cables in the Future

Commercial Semi-Instantaneous Water Heaters

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

HI-VELOCITY SYSTEMS

SECTION DRY-TYPE TRANSFORMERS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool

Tasarım ve Baskı: AJANSBRAND A

Element D Services Heating, Ventilating, and Air Conditioning

Vehicle Design Summit Electric Hub Motor (V2) Eric Conner Harvey Tang Matthew Peddie

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

High School Graduation years 2013, 2014, Unit/Standard Number

Transformer Calculations

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Horizontal Jet Pumps 1/3-1-1/2 HP

Cooling Capacity CFM in. w.c. (125 Pa)

1150 hp motor design, electromagnetic and thermal analysis

Principles of Adjustable Frequency Drives

Power Transformer Fundamentals: Design and Manufacturing

Model 1210C Battery Powered Pump Shown. Description

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Diesel Engine Driven Generators Page 1 of 6

Power transformers. Special transformers Railway

Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Low Voltage Transformers Sealed, General Purpose, Dry Type

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TWE+TTA TWE+TWA T.R.

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

Single-Phase AC Synchronous Generator

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Tutorial One: Calculation of leakage inductance of transformer using FEM MVA, 132 kv/33kv, Y/, Ampere-turns: , No.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

SECTION MORTUARY REFRIGERATORS

MUELLER FALLING FILM CHILLERS

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Nominal Life Expectancy for Building Components

UEENEEJ164A Analyse the operation of HVAC air and hydronic systems

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

The "DAVID" Steam Engine By Alan Marconett Hobbit Engineering

Table of Contents. TransformerIQ FAQs 1

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Chapter 22: Electric motors and electromagnetic induction

Oil and Coolant Circulating Heating System. Model - OCSM

Lightning Arresters P KVA P KVA. Description & Installation

Amendments to the Compendium of Classification Opinions

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Corrugated Tubular Heat Exchangers

Enhancing the Design of Electric Machines through the Interaction of Software Tools. Markus Anders Electric machine sector manager CD-adpaco

3. Three phase winding technology

Transcription:

CONSIDERATIONS WHEN SPECIFYING Application A TRANSFORMER Configuration Internal Construction Dielectric Fluid Accessories

APPLICATION Distribution Running lights, HVAC, Office Motor Control Center Dedicated Load Pump, Crusher Extreme Duty Drag-line

Available Configurations Padmount Station Secondary Unit Substation Specialty Grounding, Rectifier, Mine Duty

INTERNAL CONSTRUCTION Shell vs. Core Form Transformers Rectangular vs. Round Coil Construction Disk Wound

Shell form & core form transformer construction -5 legged wound core- Each phase has a magnetic flux return path independent from the other phases. - 3 legged stacked core- Each phase shares a core bar. Harmonic content can lead to tank heating if wye/wye connected. IEEE Std C57.12.80-2002 definitions: Shell form: A transformer in which the laminations constituting the iron core surround the windings and usually enclose the greater part of them. Core form: A transformer in which those parts of the Magnetic circuit surrounded by the windings have the Form of legs with 2 common yokes.

Shell & core transformers

Rectangular coil & 5 legged core assembly

Distributed gap core construction ore after shear operation Distributed gaps

Distributed gap core construction Raw stock core material

Distributed gap core construction Pressed cores queued for annealing Loading the annealing oven

Distributed gap core construction Annealed cores

Rectangular coils HV finish HV taps HV start Cooling ducts LV winding Core windows LV leads

Rectangular coils w/ distributed gap cores x 2x 2x x x 2x 2x x

Rectangular coils w/ distributed gap cores Annealed Laminations Stacking the distributed gap cores

Rectangular coils w/ distributed gap cores 2 1 2 3 4 5 Application of core frame

Rectangular coils w/ distributed gap cores Assembled 5 legged distributed gap core and coil assembly

Rectangular coils w/ distributed gap cores Outer core legs and core frame

Shell & core transformers

Round core and coil assembly Top view, single core/coil

Cruciform core shear

Cruciform stacked core construction

Cruciform core construction Yoke - leg interface Top view

Cruciform stacked core construction

Cruciform core

Round Coils

Round Coils 60 degree cooling ducts Radial forces are equalized during short circuits & overloads

Core Coil Assembly Improved cooling

Core Coil Assembly core frame insulation

Round coils with cruciform core Top yoke LV leads HV leads & taps

Round coils with cruciform core Tanking assembled core & coil assembly

Disk-Type Coil Winding

Disk Coil Construction Continuous Disk Helical Disk Tube Extension PB Washer Winding Tube Static Plate Winding Tube Inner Diameter Coil Inner Diameter Coil section Outside Vertical Spacer Radial Spacer Vertical Spacer Wound Diameter Vertical Spacer Outside Vertical Spacer Winding Space WD MC MD RB Radial Spacers Winding Tube Static Plate

Stages of Disk Windings Assembly

Construction comparisons

Rectangular coil - 5 legged core advantages With strip conductor secondaries: HV electrically centered on the LV winding Significant gain in mechanical strength Suitable for high volume production No tank heating from stray flux induction in tank wall when connected wye-wye

Round coil - cruciform core uses With wire / wire windings: Means of providing increased hoop strength Enables solid construction of higher kva units Suitable for small power designs & dedicated loads Reduction in width dimension for retrofit applications

Round Coil/Cruciform Core Advantages 360 degree cooling Increased insulation life More efficient cooling during heavy duty cycles Top & bottom pressure plates Containment of axial forces during short circuits Round coil construction Maximum containment of radial forces during short circuits Improved clearances between phases

Dielectric Fluids Mineral Oil (Type II) Vegetable-Based Oil (Envirotemp FR3) High Fire Point (300 degrees C) Biodegradable Silicone Voltesso Lower Temperature Pour Point

Standard Accessories Oil Temperature Gauge Liquid Level Gauge Pressure/Vacuum Gauge Pressure Relief Valve Drain Valve w/ Sample Port Upper Fill Port Air Space filled with Dry Nitrogen

Optional Accessories Part 1 Dry Contacts on Gauges Pressure Relief Device Forced Air Cooling 15% increased capacity 2499 kva and smaller 25% increased capacity 2500 kva and larger Winding Temperature Gauge Sudden Pressure Rise Relay Seal-In Relay

Optional Accessories Part 2 Removable Radiators Positive Pressure System Stainless Steel Auxiliary Wiring Cabinet NEMA 4X Hardware Base Tank Radiators Transitions

Thank you!