ERP. Energy Recovery Ventilator. with Humidity Exchange. Technical Brochure

Similar documents
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Operation and Installation Manual. Max Series

CE6500 Energy Recovery Ventilator

Horizontal ventilation units

How To Get A Passive House

Ventilation System Air Conditioner SVC MANUAL(Exploded View)

Lesson 36 Selection Of Air Conditioning Systems

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Bring the fresh in. Dedicated Outside Air Systems

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

york air-conditioning products Residential & VRF News 2015

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

RRV934. Multi-controller. Synco living

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

LG Electronics AE Company, Commercial Air Conditioning

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

saving energy in comfort Factsheet Recair Enthalpy

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

DUCTED AIR CONDITIONING SOLUTIONS

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

squrboxbox heat recovery squrboxbox I technical information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

Innovent LASER Packaged Fresh Air Conditioning Units

Adjustable room thermostat for heating only or cooling only systems

SECTION MORTUARY REFRIGERATORS

ECOCIAT. Domestic hot water heat recovery unit

HEAVY DUTY STORAGE GAS

HVAC Processes. Lecture 7

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Energy Efficiency HOSPITALITY.

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

FULL DC INVERTER SYSTEMS

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Compact. Efficient. TROX.

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

HERZ-Thermal Actuators

RPV - RP - RA air handling units

Pioneer in sustainability

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Low Cost. Lower Energy Costs. Higher Efficiency.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Zehnder Focus 200. Ventilation device

Daikin Airconditioning UK Ltd HRV. Heat Reclaim Ventilation VAM-FA VKM-GM VKM-G

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

FTXS. Wall Mount Heat Pump or Cooling Only

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Glossary of Heating, Ventilation and Air Conditioning Terms

Unico Inverter. Unique and efficient.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

PORTABLE AIR CONDITIONER

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Pool Dehumidification Basics

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

How To Control Humidity With A Humidifier

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

CADB and CADT-D / DI / DC Series

Mechanical Rooftop Custom Capabilities

3-2. Using the air conditioning system and defogger Automatic air conditioning system

Sustainable Preservation Practices for Managing Storage Environments Webinar: April 3, 2013

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Energy Efficiency. Bars & RestauRants.

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

USER S MANUAL HSC-24A

Combi Unit Genius. The energy efficient Building Service Centre

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Portable Air Conditioner

Air Conditioning in Green Office Buildings?

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

UDSA - UDSBD unit heater

FLORIDA SOLAR ENERGY CENTER

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

Under sill units. Type FSL-B-ZAS

Energy Recovery Ventilation Equipment

Material test chamber with mechanical convection

Transcription:

Technical Brochure ERP Energy Recovery Ventilator with Humidity Exchange

Contents About Impelair Who we are, What we do. ERP Units... 1 Unit Specifications... 2 Performance Data... 3 Components... 6 Accessories... 8 Components... 6 Dimensions... 8 Impelair AS was established to serve the Heating, Ventilation and Air Conditioning (HVAC) market with innovative design, superior quality, advanced logistics and reliable services. Impelair AS aims to offer energy-efficient, easy-to-operate and service-free HVAC equipment for the market while maintaining premium quality. Impelair AS is located in the Aegean Free Zone in Izmir, Turkey. The Free Zone has more than 240 global companies taking advantage of the simplified customs and logistics procedures. The manufacturing processes involve high-tech CNC machines to ensure precise manufacturing quality and production plant efficiency. The equipment is manufactured on assembly and sub-assembly lines where quality control is carried out in line with both national and international standards. Every single unit manufactured is checked with electrical control equipment before packing to prevent any problems in the field. The HVAC market has been growing as an industry for the last 15 years. With the enhancement in building material technology and the new regulations for energy efficiency imposed by the authorities, the equipment technology is also changing to meet demand. At Impelair AS, we not only focus on today s technologies but also on communicating our vision of what tomorrow s needs will be. We are working in cooperation with the major component manufacturers, meaning we all benefit from the mutual innovations and knowhow. By applying the results of this work to our product range at Impelair AS, we create energyefficient products for buildings with a low energy profile.

ERP Units Energy Recovery Ventilator ERP Silver units are designed to meet the fresh air demand for shops, offices, hotels, day care centers, schools and similar premises. With the high end energy recovery exchanger, thermal efficiency of the unit exceeds 70% and with the perfectly engineered Radical blade AC fans Specific Fan Power of the unit goes as low as 0,80 kw/m -3 /s -1 (EN 13779). With the standard remote LCD control panel and IQ Control the user is flexible with several control settings like 3 speed fans and unbalanced ventilation, weekly timer, filter monitoring and by-pass ventilation. More control settings are available with optional accessories. Class 0 flame retardant insulation is used for sound and thermal insulation of the unit. Functions ERP Units; Supply fresh air for indoors. Exhaust stale indoor air. Transfer heat from or to supply air from the exhaust air stream. Transfer humidity from or to supply air from the exhaust air stream and reduce A/C load. Filter supply air. Energy Savings and Responsibility for Nature ERP Units; Reduces up to 70% of the energy required to condition fresh air to ambient temperature. With high efficient Radical blade AC fans, reduces power consumption. Reduces the cooling load, as a result of the humidity transfer from fresh air to exhaust air stream and decreases installed and operational capacity of the air conditioning devices. Reduces CO 2 emission, as the result of energy saving, and prevents environmental pollution. Reduces initial investment cost and operational costs of air-conditioning systems, as a result of exhausted airs energy recovery. Advantages High Thermal Efficiency with patented heat exchanger design. Low Power Consumption with RadiCal Blade AC Fans. Low Sound Level with Engineered Unit Design. Humidity Transfer. Standard LCD Remote Control with IQ Control. Easy Service and Maintenance with Engineered Unit Design. Models ERP units are designed in 5 different types with nominal airflows varying between 500 m 3 /h and 0 m 3 /h. Unit Notation Series Name Nominal Air Flow 500 800 Fresh Air Heater 00 Ventilation On Demand 00 EXAMPLE ERP - 800 - AH - CO2 The notation indicates ERP unit with 800 m 3 /h nominal airflow with electrical fresh air heater and Ventilation On Demand control with CO 2 sensor. ERP 0 CO 2 IAQ 0 0 AH RH 1

Unit Specifications Control ERP units are equipped with IQ Control. IQ Control is capable of controlling AC fans, by-pass clamp, frost heater and operation timer. The control of fans can be done with 3 speed settings/unbalanced ventilation/ ventilation on demand. 2 permanent temperature sensors measure return air/fresh air temperatures and control the bypass. Filters are checked with timer and the user is informed for filter maintenance periodically. Complete Package ERP units have by-pass ventilation as standard. With by-pass ventilation it is possible to use fresh air directly to cool down indoors at summer. The controller checks both indoor and outdoor air temperatures and user set temperature and switches on/off the clamp integrated directly to the unit. Decrease in Air Conditioning Load ERP units are capable of not only heat exchange but also moisture exchange. It is possible to move the humidity in fresh air to exhaust air stream in summer and recover the moisture of the exhaust air to fresh air in winter. As a result of the humidity exchange in summer, the air conditioning load resulted from the fresh air is reduced dramatically. Slim Design ERP units are designed to meet tough installation conditions like limited ceiling space. ERP units are limited to a maximum height of 385 mm until ERP 0 and 550 mm until ERP 0. Low Sound Level With the innovative RadiCal blade design and the decreased pressure drop of both components and internal design, the sound level of the unit is reduced along with the reduced fan speed. 2

Performance Data ERP - 500 AIR PERFORMANCE Model ERP - 500 225 125 Air Flow (l/s) 175 Power Supply 220-240 V / Single Phase / 50 Hz Fan Speed High Medium Low Max. Power Consumption W 205 Air Flow m 3 /h 500 450 350 Air Flow I/s 140 125 External St. Pressure Pa 108 75 70 175 Temp. Exc. Efficiency % 72 73 75 Pressure (Pa) 125 MEDIUM HIGH Sound (db) 36 35 32 75 50 Temperature Efficiency; η T = Outdoor Air; -3 C, 75% RH T 2 T 3 x % 25 LOW Return Air; 22 C, 55% RH 0 300 350 400 450 500 550 650 700 750 800 Sound Power Level is measured 1.5 m away from the unit at HZ. Air Flow (m 3 /h) ERP - 800 AIR PERFORMANCE Model ERP - 800 225 Air Flow (l/s) 300 350 Power Supply 220-240 V / Single Phase / 50 Hz Fan Speed High Medium Low Max. Power Consumption W 310 Air Flow m 3 /h 800 700 500 Air Flow I/s 220 195 140 External St. Pressure Pa 115 75 55 175 Temp. Exc. Efficiency % 72 74 76 Pressure (Pa) 125 MEDIUM HIGH Sound (db) 37 35 33 75 50 LOW Temperature Efficiency; η T = Outdoor Air; -3 C, 75% RH T 2 T 3 x % 25 Return Air; 22 C, 55% RH 0 300 400 500 700 800 900 0 1 1 1300 Sound Power Level is measured 1.5 m away from the unit at HZ. Air Flow (m 3 /h) 3

Performance Data ERP - 0 AIR PERFORMANCE Model ERP - 0 225 Air Flow (l/s) 300 350 400 Power Supply 220-240 V / Single Phase / 50 Hz Fan Speed High Medium Low Max. Power Consumption W 420 Air Flow m 3 /h 0 850 700 Air Flow I/s 280 235 195 External St. Pressure Pa 130 90 55 175 Temp. Exc. Efficiency % 72 73 75 Pressure (Pa) 125 MEDIUM HIGH Sound (db) 39 38 36 75 50 LOW Temperature Efficiency; η T = Outdoor Air; -3 C, 75% RH T 2 T 3 x % 25 Return Air; 22 C, 55% RH 0 500 700 800 900 0 1 1 1300 1400 0 Sound Power Level is measured 1.5 m away from the unit at Hz. Air Flow (m 3 /h) ERP - 0 AIR PERFORMANCE Model ERP - 0 225 300 Air Flow (l/s) 400 500 700 Power Supply 220-240 V / Single Phase / 50 Hz Fan Speed High Medium Low Max. Power Consumption W 580 Air Flow m 3 /h 0 1 700 Air Flow I/s 415 305 195 External St. Pressure Pa 65 105 125 175 Temp. Exc. Efficiency % 71 72 73 Pressure (Pa) 125 MEDIUM HIGH Sound (db) 43 41 40 75 50 LOW Temperature Efficiency; η T = Outdoor Air; -3 C, 75% RH T 2 T 3 x % 25 Return Air; 22 C, 55% RH 0 800 0 1 1400 1 1800 0 2 2400 2 Sound Power Level is measured 1.5 m away from the unit at Hz. Air Flow (m 3 /h) 4

Performance Data ERP - 0 AIR PERFORMANCE Model ERP - 0 225 300 Air Flow (l/s) 400 500 700 Power Supply 220-240 V / Single Phase / 50 Hz Fan Speed High Medium Low Max. Power Consumption W 980 Air Flow m 3 /h 1900 1400 0 Air Flow I/s 525 385 275 External St. Pressure Pa 70 95 60 175 Temp. Exc. Efficiency % 70 71 72 Pressure (Pa) 125 MEDIUM HIGH Sound (db) 49 47 46 75 50 LOW Temperature Efficiency; η T = Outdoor Air; -3 C, 75% RH T 2 T 3 x % 25 Return Air; 22 C, 55% RH 0 800 0 1 1400 1 1800 0 2 2400 2 Sound Power Level is measured 1.5 m away from the unit at Hz. Air Flow (m 3 /h) 5

Components Heat Exchanger The energy recovery exchanger used in ERP products are made from a unique thin paper film that allows both heat and humidity transfer from the two separated air streams with a very high performance rate. Since the paper is thin (app ~0,05 mm) both temperature and humidity can be effectively exchanged. The unique structure of the paper allows the transfer of only the water molecules from the heat exchange surface and as a result of the solid molecular structure the leakage through air streams is minimized. With the unique energy recovery exchanger ERP units reach a thermal efficiency of 70% in summer and 76% in winter. With the given performance it is evident that with ERP units the total air conditioning load can decrease up to 15% in a regular cooling system. EA Stale air exhaust SA Fresh air supply to the room OA Fresh air induction RA Stale air extraction from the room ERP units deliver not only absolute thermal efficiency but thanks to the optimized design, pressure drop across the heat exchanger is limited to meet not only todays but also tomorrow s energy efficiency regulations. 0 10 20 90 80 70 60 50 40 30 WINTER ENTHALPY (kj/kg) 110 SUMMER 120 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 ABSOLUTE HUMIDITY (gr WATER VAPOR / kg DRY AIR) -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 DRY BULB TEMPERATURE ( C ) 6

Components Control ERP units are equipped with IQ Control. IQ Control is capable of controlling AC fans, by-pass clamp, frost heater and operation timer. The control of fans can be done with 3 speed settings/unbalanced ventilation/ventilation on demand. 2 permanent temperature sensors measure return air/fresh air temperatures and control the by-pass. Filters are checked with timer and the user is informed for filter maintenance periodically. By-Pass By-pass ventilation is done during summer and allows return air to by-pass the heat exchanger introducing fresh air at outdoor air temperature and cools down indoors. ERP Units are equipped with by-pass ventilation as standard. With the pre-installed temperature sensors IQ Control checks return air temperature, fresh air temperature and user set temperature. According to the evaluation in the PCB, the by-pass clamp is opened automatically. Warm Climate Moderate Climate Hot Climate 2523 5124 2024 6437 1520 6768 Based on 24h operation Heating Time / Year Cooling Time / Year By-Pass ventilation Time / Year 1113 299 472 Fans Innovative RadiCal blade fans with AC motors are used in ERP units. Casing ERP units are designed to have a compact and service-easy construction. All of the components can be disassembled without the need of dismantling the unit and ducts. The height of the product is minimized to have a compact design ensuring the minimum pressure drop inside the unit at the mean time. Galvanized sheet metal is used for ERP units and the unit is insulated against thermal leakage and sound with M1 class flame retardant Polyurethane foam. 7

Accessories Demand Controlled Ventilation Ventilation On Demand; VOD, by use of additional CO 2 /IAQ or RH sensor the demand indoors is calculated and the fan speed settings are adjusted accordingly. To switch to VOD mode, a proper sensor must be installed and connected, to the duet system and also the user must select VOD on Select Mode menu of the Remote Control. When VOD (Ventilation On Demand) is selected the fan speed is controlled by the analog 0.10V input signal. At 0...1V the fans are running at minimum VOD speed and at 9...10V the fans are running at maximum speed for VOD. In between the fan speed is linearly controlled. Empty Home Minimum Air Flow Minimum Air Conditioning Load Minimum Energy Consumption Partial Load Medium Air Flow Medium Air Conditioning Load Medium Energy Consumption Full Load Maximum Air Flow Maximum Air Conditioning Load Maximum Energy Consumption Filters Panel filters are used in ERP units for standard filtration. Filtration class is G3 according to EN 779. G3 filters are medium efficiency disposable air filters suitable for ventilation applications with good dust holding capacity. The filters consist of a dry non-woven extended surface fabric media and create low initial pressure drop. Dimensions Model Dimensions L W D Weight (kg) H 500 1220 725 0 50 385 ERP 800 1220 0 0 61 385 0 1370 1275 0 80 385 0 1535 1115 0 300 102 550 0 1535 1415 0 300 126 550 8

www.impelair.com

Impelair AS. Aegean Free Zone Gündüz Sokak D-1/D 35410 Gaziemir, Izmir Turkey Phone (+90) 232 251 70 20 Fax (+90) 232 251 57 38 www.impelair.com 116 - ERP SERIES FEB 2014 impelair reserves the right to make alterations due to technical developments without prior notice.