Products. Load banks Electronic. Computerized. Resistive. Manual. Inductive. Test Systems. Battery Chargers. Others

Similar documents
DC Electronic Loads 8500 series

Temperature & Humidity SMS Alert Controller

SL Series AC and DC Electronic Loads

Thyristor-controlled power supplies and battery chargers

Power Electronics Testings

UPS Applications and VRLA Battery Sizing

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Essential Electrical Concepts

1.44 kw Programmable DC Power Supplies XLN Series

VOLTAGE REGULATOR AND PARALLEL OPERATION

Specification Requirements DBL 700MX and 1000MX Series UPS

Inverter / Charger Installation General Operations and AC and DC Connections

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Uninterruptible Power Supply

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

TMS TANK MANAGEMENT SYSTEM

High Power Programmable DC Power Supplies PVS Series

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

MPR-Systems. Mini Power Racks 1200 W W

Modular I/O System Analog and Digital Interface Modules

Product Specification instalert Rapid Messenger Variable Message Sign

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Power Electronics Testing

PowerGem Pro Uninterruptible Power Supply

Executive Summary. Technical Description

OPERATING INSTRUCTIONS

OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

User Guide Reflow Toaster Oven Controller

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Mixing Sodium and Lead Battery Technologies in Telecom Applications

Air conditioning, electrical testing

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Self Monitoring Power Supply (BPSM)

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Permissible ambient temperature Operation Storage, transport

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

I. R. D. T INSTITUTE OF RESEARCH DEVELOPMENT AND TRAINING

NC-12 Modbus Application

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Temperature & Humidity SMS Alert Controller

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

TruPower-Portable-500W. Solar Starter kit

User s Manual Before using the inverter, you need to read and save the safety instructions.

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Electrical Systems. <Presenter>

Battery Test Solutions Pack/Module/Cell

ABB PSPS Erich Steinmann; Generator control-2013

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

SECTION DETECTION AND ALARM

MIDNITE SOLAR AND SOLAR WASHINGTON

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

The Basics of Digital Multimeters

KONSTANTER SPL / SPL Programmable Electronic Load

RS - SPM. Serial parallel translator module

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SMART SENSOR COLLECTION

FIREDEX Conventional Fire Panels

MAJORSINE Power Inverter

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Considerations When Specifying a DC Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Multi-Range Programmable DC Power Supplies 9115 Series

OUTPUT CABLE CONNECTIONS:

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Low and High Voltage Power Supplies

Multi-Range Programmable DC Power Supplies 9115 Series

Phase Modular Finally the benefits of Modular ups are for all

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual for CH-PFC76810

A Practical Guide to Free Energy Devices

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

EC450 Power Control System

BATTERY MANAGEMENT SYSTEM

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Stroom voor elke toepassing

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Everything you need for protection scheme testing

7-41 POWER FACTOR CORRECTION

38 Series - Relay interface modules A

Contactless Power Transfer : Inductive charging of EV

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Transcription:

Products Load banks Electronic Resistive Inductive Computerized Manual Test Systems Battery Chargers Others

Electronic load Bank - Computerized 220V/360A 6KW 12V/2200A 20KW 100V/200A 200V/200A 220V/40A 220V/80A 220V/100A 12V/1200A Electronic load Bank - Manual DC Programmable multi load system 16V/20A 20V-60V/300A,6KW 60V/120A,600W 60V/10A,300W 35V/25A 48-60V/150A 3Channel Electronic Load Bank

Resistive load Banks 12V/1500A,18KW 48V/300A,14.4KW AC Resistive load 220V/360A,79.2KW Trolley Resistive load Inductive load Banks 30KVA Inductive Load Battery Chargers Cell Booster SMPS Charger Digital Charger 15V/200A Charger 2-12V/50A Cell Booster Battery Chargers -Computerized 12KW Programmable DC Supply 24KW Programmable DC Supply

Test Systems Others Life Cycle Tester Thermal Battery Test system i-charger Ageing Setup Automated Test Equipment Automated Charge Setup DC Power Supply Instantaneous β Mini tester High Power oil cooled Rectifiers

Electronic load Bank-Computerized 220V/360A Electronic Load Bank Designed to perform load simulation tests on various DC Sources such as Rectifiers, AC-DC converters, Battery Banks, Chargers Etc Voltage range of 160-220V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-360 Amperes Max Load capacity is 360A Or 72 KW max User friendly application software The Battery voltage and Battery current are recorded by the Data Acquisition Electronics module and are transferred to the Computer / HMI connected to the system

6KW Electronic Load Bank High power Electronic load bank, Designed for Performance analysis of EV batteries. Voltage range of 10-120V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-500 Amperes. Max Load capacity is 500A Or 6 KW max User friendly application software Modes of operation :Constant Current, Constant power Operating mode: Manual, Remote modes

12V/2200A Electronic Load Bank High Rate discharge electronic load bank,designed to perform capacity test on submarine batteries. Voltage range of 4-12V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-2200 Amperes Max Load capacity is 2200A Or 26.4 KW max User friendly application software RS232 interface with easy to use application software Modes : Constant Current, Constant power Operation: HMI, Remote modes

20KW Electronic Load Bank 30V 1500A or 20 KW Max. Manual and remote mode operation. RS232 Interface with easy to user Application Software. Operating mode: Constant current. Measurement :Voltage/Current/AH with programmable sample rate Protections: Over Voltage, over current, over power and reverse protection

100V/200A Electronic Load Bank High Rate discharge electronic load bank, Designed to perform discharge load simulation on Primary batteries Voltage range of 10-100V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-200 Amperes Max Load capacity is 200A Or 20 KW max Squib firing electronics Dynamic Pulse load simulation of as low as 10mS @1mS DAQ User friendly application software Max Load capacity is 200A Or 20 KW max Operating mode: Constant Current, Constant power,constant Resistance,Constant voltage

200V/200A Electronic Load Bank High Rate discharge electronic load bank,designed to perform discharge load simulation on Primary batteries Voltage range of 10-200V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-200 Amperes Max Load capacity is 200A Or 40 KW max Igniter firing electronics to test fire the primary batteries Dynamic Pulse load simulation of as low as 10mS @1mS DAQ User friendly application software Operating mode: Constant Current, Constant power,constant Resistance,Constant voltage

220V/40A Electronic Load Bank Designed to perform load simulation tests on various DC Sources such as Rectifiers, AC-DC converters, Battery Banks, Chargers Etc. Voltage range of 160-220V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-40 Amperes. Max Load capacity is 40A Or 8.8 KW max. User friendly application software. The Battery voltage and Battery current are recorded by the Data Acquisition Electronics module and are transferred to the Computer / HMI connected to the System

220V/80A Electronic Load Bank Designed to perform load simulation tests on various DC Sources such as Rectifiers, AC-DC converters, Battery Banks, Chargers Etc. Voltage range of 160-220V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-80 Ampere Max Load capacity is 80A Or 17.6 KW max. User friendly application software. The Battery voltage and Battery current are recorded by the Data Acquisition Electronics module and are transferred to the Computer / HMI connected to the System

220V/100A Electronic Load Bank Designed to perform load simulation tests on various DC Sources such as Rectifiers, AC-DC converters, Battery Banks, Chargers Etc Voltage range of 160-220V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-100 Amperes Max Load capacity is 100A Or 22 KW max User friendly application software The Battery voltage and Battery current are recorded by the Data Acquisition Electronics module and are transferred to the Computer / HMI connected to The system

12V/1200A Electronic Load Bank High Rate discharge electronic load bank,designed to perform capacity tests on submarine batteries. Voltage range of 4-12V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-1200 Amperes. Max Load capacity is 1200A Or 10 KW max. User friendly application software. Operating mode: Constant current, Constant power.

DC Programmable Multi Load System Designed to multi channel electronic load for precise load control and performance analysis of primary & secondary batteries. Voltage range of 10-150V. This system is capable of efficiently loading the DC Source with a constant current in the range of 0-400 Amperes. Max Load capacity is 400A Or 40 KW max. 10Kw, 30Kw,40Kw and 10+30Kw. User Configurable load control. High precision programmable current pulse for ignition. Précised data acquisition. Dynamic pulse loading at 10milli second. Load Realization time is < 1mSec. Dedicated application software package. Test Termination by time, by Voltage, by Forced Termination and Emergency Cutoff(Circuit Breaker). Protections : Reverse,Short circuit

Electronic Load Bank-Manual 16V/20A Electronic Load Bank Designed for Load simulation tests on DC power supplies Voltage range of 4-16V.The system is capable of efficiently loading the DC source with constant current in the range of 0-20 Amperes Max load capacity 20 Amps Operating mode: Manual mode

20-60V/300A,6KW Electronic Load Bank Designed to perform the discharging the aircraft batteries. Voltage range of 20-60V.The system is capable of efficiently loading the DC source with constant current in the range of 0-300 Amperes. Max load capacity 300 Amps or 6 KW. Operating mode: Manual mode.

60V/120A,600W Electronic Load Bank Designed for Load simulation tests on High voltage SMPS. Voltage range of 10-60V.The system is capable of efficiently loading the DC source with constant current in the range of 0-120 Amperes. Max load capacity 120 Amps or 600 Watt. Easy to operate, load START and STOP switches Operating mode: Manual mode

60V/10A,300W Electronic Load Bank Designed for Load simulation tests on Solar panels Voltage range of 2-60V.The system is capable of efficiently loading the DC source with constant current in the range of 10 Amperes Max load capacity 10 Amps or 300 Watt Easy to operate, load START and STOP switches Operating mode: CC,CP,CR,CV Operation: Manual mode

35V/25A Electronic Load Bank Designed for Load simulation tests on Solar panels. Voltage range of 4-35V.The system is capable of efficiently loading the DC source with constant current in the range of 25 Amperes Max load capacity 25 Amp Easy to operate, load START and STOP switches Operating mode:cc,cp,cr,cv

48-60V/150A Electronic Load Bank Designed for Load simulation tests on lead acid batteries Voltage range of 35V-60V.The system is capable of efficiently loading the DC source with constant current in the range of 150 Amperes Max load capacity 150 Amps Easy to operate, load START and STOP switches AH Display through AH Meter Operating mode: CC,CP,CR,CV Operation :Manual mode

3 Channel Electronic Load Bank Designed to perform the discharging 3 individual batteries simultaneously Voltage range of 5-45V.The system is capable of efficiently loading the DC source with constant current in the range of 0-10 Amperes(3 X 10) simultaneously and 3 channels parallel, i.e. 30 Amperes Max load capacity 30 Amps or 1350 Watt Operating mode: Manual mode

Resistive Load banks 12V/1500A,18KW Resistive Load Designed for Load simulation tests on battery banks Load setting through MCB's and Disconnected Switches Max Load capacity current 1500A Voltage,current and AH display through Digital display Meters

48V/300A Resistive Load Designed for load simulation tests on battery banks and DC Generators Load setting through toggle switches Max Load capacity 300A Portable for field service applications Voltage and current display through digital display meters

AC Resistive Load Bank Designed for Load Simulation Tests on AC MCB's and DG sets Load Setting through Toggle switches Load is designed per phase is 15A @ 230VAC Max Load capacity : 45A Voltage and Current display through Digital display meters

220V/360A Resistive Load Designed for Load simulation tests on Battery banks and power plant batteries Load setting through Rotary switches Max Load capacity is 360A Voltage and Current Display Through Digital display Meters

Trolley Resistive Load 48V/100A 4.8KW Designed for Load Simulation Tests on Battery banks Load setting through Toggle Switches Max Load capacity 100A Voltage and Current Display Through Analog display meters

30KVA Inductive Load Designed for Load Simulation on DG sets Max load capacity: 30KVA Simulation of 0.8PF and unity PF Load Protected by Over voltage,under voltage and Short Circuit Load Protected by Thermal Cut Off (>80 Degrees) Display of KVA, KW, PF, KVR, 3 Phase Voltages and 3 Phase Currents by Digital Energy Meter.

Life Cycle Tester Designed to meet BIS standards for cycle testing of various batteries. Capable of performing Capacity test(discharge). Capacity test perform on Constant Current, Constant Power Mode. Charge test perform on Constant Current,Constant Voltage,Constant Power mode. Instant charge over from Charge to Discharge or vice versa. Precise data Acquisition. Individual cell voltage monitoring. Battery Temperature & Ampere Hour Monitoring. Online Tabular, Graphical Display while testing. Dedicated application software package. The test results are presented both in graphical and tabular forms. User friendly GUI of the system.

Thermal Battery Test System Specially designed to test fire the thermal batteries used in missiles. Configurable load control. High precision programmable current pulse ignition. Squib firing Electronics For testing Squib/ Pyros for allfire and no fire currents. Précised data acquisition. Dedicated application software package. The test results are presented in both graphical and tabular forms. User Friendly GUI of the system

i -Charger Constant Current and Constant Voltage options for Charge. Individual Cell Monitoring. Custom made jig for individual cell accessing. Dedicated data acquisition module for individual cell monitoring. Optional CC Discharge facility for capacity test. User Programmable end limits for Charging/Discharge. AH Computation and display. Charge/Discharge configuration based on the type of battery. Suitable for Ni-cd, AgOZn and lead acid batteries. User friendly GUI

Ageing Setup Designed to carry out ageing test on multi output SMPS modules Capable of loading 30 Multi o/p SMPS modules simultaneously Continuous monitoring of the condition of each section of the SMPS Raises an alarm (LED or BUZZER) on fault detection The ageing hot chamber maintains temp level Modular construction Easy to connect and disconnect the SMPS modules Programmable load current for each section Voltage and current display for each section of the SMPS Protected against SHORT CKT & REVERSE POLARITY Soft start and delayed switching ON of SMPS to reduce inrush current Source connected for each section of SMPS Reverse Polarity (Audio & Visual) Power On, Load On Ageing chamber temperature indicator

Automated Test Equipment Salient Features: Specially designed to test/define electrical performance characteristics of SMPS based AC to DC switching adaptors Capable of performing various tests on 2 adaptors simultaneously Online voltage, current display through digital meters, test pass or fail indication through front panel LEDs Audio alarm for test pass or fail indication Can be configured R&D, production and quality control test setup Software Features: Dedicated application software package with user friendly GUI Online serial number allocation and sticker printing for passed adaptors Separate serial number allocation for failed adaptors for verification of test results later User has the Option To select/edit/configure new model test parameters To take different types of reports on test data To take reports either by serial number or by date To select different combinations of tests To select different types of stickers Test data will be stored -date wise in separate files Separate backup (results) for passed and failed adaptors Online printing of stickers for passed adaptors Allows design of sticker to cater to various customer needs

Automated Charge Setup Automated Charge Setup For AgOZn Batteries Five independent modules to cater to five batteries simultaneously Each module is capable of acquiring cell voltages of up to 23 cells (Extendable) Monitors and acquires individual cell voltages,total battery voltage and battery current Specially designed jig fixtures for each type of the battery Gold plated spring contact pins for each cell voltage monitoring User interactive GUI based application software Flexible test configuration wizard Programmable individual cell cut - off limits Pause and resume facility Automatic test resumption on power failure and retrieval Programmable sampling rates, based on end voltage Auto test cut - off based on end voltage Online display of test parameters Graphical and tabular representation of the acquired data

DC Power Supply Designed for charging battery. Voltage range 0-64V. Current range 0-5Amps. Modes of operation :CC,CV. Input power supply 230 Volts AC. Protections: Over voltage, over load, short circuit, reverse polarity.

BETA TESTER INSTANT BATTERY TESTER Designed around latest micro controller based electronic load control In put Voltage : 10V-13V DC Voltage Load Current: 10A-100A DC Current (Programmable) Test Duration: Selectable Test Duration - 15/30 sec s Data Storage: Open ckt Voltage, On Load voltage, Load current are stored in USB pen drive. Can store up to 99 test records Display: Voltage and Current Display through 4*20 LCD Display Modes of Operation: CC (Constant Current) Ergonomically designed, User-friendly LCD KEYPAD. Protections: Over voltage and Reverse Polarity Indications: Power On and Test Over (Buzzer indication) Cooling: Forced Air cooling No external auxiliary supply required. Operates on battery Less power consumption (< 5W) Input Termination: 25sqmm PVC cable with Heavy duty Crocodile Clips Software: Application software for data extraction, display and hard copy in pre-defined report format Portable and Suitable for field testing and capacity assessment of batteries Can be used for testing battery in a series string of battery bank without disconnecting from the bank

Battery Chargers Cell Booster Designed for charging the Individual weak cells. Voltage range 2-15V Max charging current is 50A Portable for Field service applications Voltage and current display through digital Voltmeter and Current meter. Voltage and Current setting through course and fine potentiometers. Mode of operation: CV and CC through Switch. Forced Air cooling.

SMPS Charger Designed for charging the Battery banks. Voltage range 4V-60V Max charging current is 25A Portable for Field service applications Voltage and current display through digital Voltmeter and Current meter. Voltage and Current setting through course and fine control. Mode of operation CV and CC through Switch. Forced Air cooling.

Digital Charger Designed for charging the Aircraft batteries. Max charging current is 25A Portable and easy to carry. Voltage and current display through digital Voltmeter and Current meter. Digital Timer is providing to Cut off the charging current at setting time. Purpose of battery safe Voltage and Current setting through course and Fine control. Mode of operation CV(constant voltage) and CC(constant current) Through Switch. Forced Air cooling.

15V/200A CV Charger Designed for charging the automotive batteries. Max charging current is 200A Voltage and current display through digital Voltmeter and Current meter. Voltage and Current setting through course and fine control. Mode of operation CV(constant voltage). 3 phase,6 pulse battery charger Forced Air cooling.

2-12V/50A Cell booster Designed for charging the Battery banks. Max charging current is 50A Portable for Field service applications Voltage and current display through digital Voltmeter and Current meter. Voltage and Current setting through course and fine control. Mode of operation CV and CC through Switch. Forced Air cooling.

12KW Programmable DC Supply Designed for charging the Battery banks. Voltage range 60-150 V Max charging current is 200A and Power is 12KW Voltage, current and power programmable sample rate with software. Voltage and current display through digital Voltmeter and Current meter. RS232 interface with easy to use application software Mode of operation CV,CC and CP Operation: Manual and remote mode,external selection through switch Modular design Input supply :3 Phase,4 wire Cooling : force air

24KW Programmable DC Supply Designed for charging the Battery banks. Voltage range 120-300 V Max charging current is 200A and Power is 24KW Voltage, current and power programmable sample rate with software. Voltage and current display through digital Voltmeter and Current meter. RS232 interface with easy to use application software Mode of operation CV,CC and CP Operation: Manual and remote mode,external selection through switch Modular design Input supply :3 Phase,4 wire Cooling : force air

High power oil-cooled Rectifier Salient Features: Input : 230v,1Ø,50Hz or 415v,3Ø,50Hz Output voltage : DC 6 volts - 150 volts (as specified) Output current : 5A - 2000A (as specified) Cooling : Oil cooling Dimmer controlled linear type rectifier Modes of operation : CV/CC Ergonomically designed, User - friendly control panel Auto/Manual operation selection through front panel toggle switch Push to on and push to off switches connected through high power contactor Tin plated, color coded heavy duty copper bus bars Protected from : Single phasing, short circuit Indications for : R - Y - B, High temperature, Oil level, Digital panel meters for voltage and current Dimmer And Rectifiers are housed in separate tanks for easy maintenance Powder Coated surface - protects from environmental changes