Gasketed heat exchanger, XG 65 / 85

Similar documents
Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Solenoid valves 2/2-way direct-operated Type EV210A

Technical data. Danfoss DHP-A

Thermostatic element RAVV for 2-way valves

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Assisted lift operated 2/2-way solenoid valves Type EV250B

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

Automatic Bypass Control AVDO

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

solarplus solar systems general features

Butterfly Valves PN 6/10/16 for flanged connection

Solar Collector Series. Product List

Transformer oil cooler ALFA A02

Thermostatic valve Type AVTA

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

VAD Variable Area Desuperheaters

HDA

ECOCIAT. Domestic hot water heat recovery unit

Questionnaire Pure Media Systems

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Data sheet ECC 12 and 22

VAD. Variable Area Desuperheaters

2- and 3-port valves with flanged connections, PN 10

Blowdown vessels Meeting the requirements of HSE PM60

Self-operated Temperature Regulators Temperature Regulator Type 1u

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Thermostatic Actuators

Stove-boiler for solid fuels KW Directions for use and assembling

SF15K SF05KSS, SF10KSS

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Corrugated Tubular Heat Exchangers

Plate Heat Exchangers. Series FP, FPDW

Series description: Wilo-Yonos MAXO

Solenoid valves Type EVU

BRAZED PLATE INSTALLATION MANUAL

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SOLAR HEATING SYSTEMS.

API Flanged Safety Relief Valves Series 526 CATALOG

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Clinic Washer-Disinfectors. Washer-Disinfector Line

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

3/2-way Solenoid Valve, direct-acting, NC or NO

Installation and maintenance instructions. Danfoss Vent

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

ECOplus Solar Cylinder

HEAVY DUTY STORAGE GAS

V5001S. Kombi-S Shutoff Valve. Product specification sheet

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

How To Use An Akua Magnetic Lime Scale Preventing Device

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

IEC Connectors. Introduction

MFP14, MFP14S and MFP14SS Automatic Pumps

QLM and QLD Series Three-port Control Valves

stainless steel pre-assembled manifolds

Sondex Welded heat exchangers:

Series description: Wilo-Yonos MAXO-D

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

MAKING MODERN LIVING POSSIBLE. Instantaneous Water Heaters. Instructions for installation and use. Danfoss District Energy

Operators manual Basic water heater

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Vacuum drying oven for non-flammable solvents

High-efficient gas boiler CompactGas

Kompressoren. Adsorption Dryer AD

Solar Hot Water Heaters

Air Eliminators and Combination Air Eliminators Strainers

SITRANS F flowmeters SITRANS F M

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

SISTO-16TWA/HWA/DLU. Type Series Booklet

CRN A-F-G-E-HQQE 3x400D 50 HZ

VALVES FOR REFRIGERATING SYSTEMS

OPTIMASS 1400 Technical Datasheet

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

HEAT INTERFACE UNITS (Modular)

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Transcription:

Description / application The XG is a heat exchanger with gasket developed for use with district heating and cooling systems. The heat exchangers can be opened for cleaning puposes and for replacement of plates and gaskets. The XG plate heat exchangers with gaskets are manufactured with different plate sizes. Approvals: Pressure Equipment Directive (PED) 97/23/EC GOST/Russia Main data: - Min. temperature 0 C - Max. temperature +150 C - Max. working pressure 16 bar - Circulation water / glycolic water up to 50% - Connection size DN 150 (flanged) - Clip-on gaskets DH-SMT/FI VD.KA.Y1.02 Danfoss 05/2006 1

Ordering Explanation, XG type XG 65 1 10 Number of plates Pass of the heat exchanger 1 = 1-pass 2 = 2-pass Plate size Gasketed heat exchanger Plate types L- type H- type The heat exchanger consists of plates type L or plates type H. The H- type plate has larger herring bone angle than the L- type plate. H- type plate fits better e.g. for certain cooling applications than L- type plates. H- type heat exchangers have higher heat transfer rate, but they also have higher pressure loss. The XG 65 and bigger gasketed heat exchangers consist of the plate set which contains both H- and L- type plates. The dimensioning process of the heat exchanger determines the ratio between H- and L-type plates. The result of the plate set is as effective and as suitable for its purpose as possible. General Danfoss code numbers indicate XG types and accessories in general. They do not identify the exact content of the heat exchanger or the accessories. These heat exchangers are dimensioned and manufactured individually by orders. The selection and dimensioning is done by Danfoss sales personnel. The request for a quotation following next page can be used to give all necessary details for the sales personnel in order to prepare a quotation. The order can be placed upon the given quotation. Gasketed heat exchanger type XG Type XG 65 XG 85 General code for heat exchanger 004B2049 004B2052 Accessories for gasketed heat exchanger type XG Type XG 65 XG 85 General code for insulation 004B2054 004B2057 General code for accessories and spares 004B2059 004B2062 2 VD.KA.Y1.02 Danfoss 05/2006 DH-SMT/FI

Ordering continued Request for a quotation The quotation form can be filled out and faxed to the Danfoss Sales representative. In digital version of Data sheet you can also download the quotation form in.doc -format to be filled out and sent by e-mail. Company Contact person Telephone Fax E-mail address Technical requirements for a heat exchanger Application Heating Domestic hot water Cooling Capacity, kw Min. heat surface margin / over surfacing, % Hot side Medium Water Glycol % Other Flow, l/s (m 3 /h) Inlet temperature, C Outlet temperature, C Maximum pressure drop, bar Cold side Medium Water Glycol % Other Flow, l/s (m 3 /h) Inlet temperature, C Outlet temperature, C Maximum pressure drop, bar Design requirements Max. working pressure, bar Max. working temperature, C Additional requirements Plate material EN 1.4301 (AISI 304) EN 1.4401 (AISI 316) Pipe connection material (inlet) Carbon steel EN1.4401 (AISI 316) lining Other information Oy Danfoss Ab Danfoss LPM Box19 79101 Leppävirta Finland Phone: +358 403 092 200 Fax: +358 403 092 281 sales@danfoss.com www.danfoss.com www.lpm.danfoss.fi DH-SMT/FI VD.KA.Y1.02 Danfoss 05/2006 3

Technical data Type XG 65-1 XG 85-1 Max. working pressure (bar) 16 Max. operating temp. ( C) 150 Min. operating temp. ( C) 0 Flow medium Circulation water / glycolic water up to 50% Volume/channel (litres) 1.780 2.520 Heat surface, m²/plate 0.550 0.850 Connection type Place for flange 1) Connection size (DN) 150 Plate material Stainless steel, mat. no. EN 1.4401 or EN 1.4301 Gasket material, rubber EPDM Gasket type Clip-on 1) Flanges PN 16 acc. to EN 1092, facing type B (B1) Design and function T12 T11 T22 T11 T22 T21 T11 - Primary side in T12 - Primary side out T112 - Primary side second inlet (2-pass) T21 - Secondary side in T22 - Secondary side out T212 - Secondary side second inlet (2-pass) T112 T12 T21 T212 1-pass heat exchanger 2-pass heat exchanger The heat exchangers are made of shape-pressed heat plates between which the flow channels are created. Gaskets between the plates separate the flow channels from each other so that the flows do not mix. The heavy turbulence and counter-flow principle enables efficient heat transfer. The task of the heat exchanger is to transfer heat from the primary to secondary flow through a heat transfer plate thus preventing the flows from mixing with each other. The plate heat exchanger with gaskets can be opened for cleaning and for replacement of plates and gaskets. A stepless output adjustment can be carried out by changing the number of plates. The choice of heat exchanger is determined by the desired heat output, required temperatures and the permitted pressure losses. Sizing Dimensioning and selection of the heat exchangers can be done by Danfoss Sales personnel only. The types XG65 and bigger gasketed heat exchangers are not included in the Danfoss dimensioning program for heat exchangers. 4 VD.KA.Y1.02 Danfoss 05/2006 DH-SMT/FI

Mounting The heat exchanger must be mounted in vertical position. It is recommended that all pipes connected to the heat exchanger are equipped with shut-off valves for maintenance purposes. The pipes to be connected must be mounted so that the strain caused by the thermal expansion, for instance, does not harm the heat exchanger. The pipes must be equipped with brackets to prevent any torsional stress concentration at the heat exchanger s pipe connections. It is recommended that the heat exchanger is equipped with insulation. Dimensions Lmax H A F D B C I Type Connection External dimensions [mm] A B C D H F I Lmax Weight empty [kg] XG 65- DN 150 3,5*n 740 380 1057 A+120 1675 330 2500 2.9*n+1100 XG 85- DN 150 3,5*n 740 380 1531 A+120 2149 330 2500 4.0*n+1420 n = number of plates Place for flange n d₃ DN 150 k 240 n mm 8 L 60 d 3 M20 Material Material Carbon steel or EN 1.4401 (AISI 316) lining L k DH-SMT/FI VD.KA.Y1.02 Danfoss 05/2006 5

Dimensions continued Dimensions of the heat plates L-type H-type C C C C A C C C C B B Type Dimensions [mm] A B C XG 65-1268 593 150 XG 85-1743 593 150 6 VD.KA.Y1.02 Danfoss 05/2006 DH-SMT/FI

DH-SMT/FI VD.KA.Y1.02 Danfoss 05/2006 7

8 VD.KA.Y1.02 Danfoss 05/2006 DH-SMT/FI