Hourly Analysis Program v.4.1 Page 1 of 1

Similar documents
Energy Efficient HVAC-system and Building Design

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

EN Insulating glass units, intended to be used in buildings and construction works

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

EN Insulating glass units, intended to be used in buildings and construction works

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

EN NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

EN Insulating glass units, intended to be used in buildings and construction works

Air Conditioning Contractors of America

DEVELOPMENT OF AN OPEN SOURCE HOURLY BUILDING ENERGY MODELING SOFTWARE TOOL

Federation of European Heating, Ventilation and Air-conditioning Associations

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

HVAC Calculations and Duct Sizing

Element D Services Heating, Ventilating, and Air Conditioning

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Innovent LASER Packaged Fresh Air Conditioning Units

CHAPTER 4 LOAD CALCULATIONS 4.1 CONTEXT

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

THERMAL LOSSES Thermal Losses Calculations

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

By Tom Brooke PE, CEM

Below are detailed instructions for using the EMS load calculator.

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Relative Humidities RH%

Greenhouse Cooling. Why is Cooling Needed?

Flexibility, Efficiency In San Antonio Arena

Whole House Dehumidification for Occupant Comfort and Energy Savings

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Load and Energy Calculations

Software Development for Cooling Load Estimation by CLTD Method

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Benefits of. Air Flow Management. Data Center

FLORIDA SOLAR ENERGY CENTER

Dedicated Outdoor Air Systems (D.O.A.S.)

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

Air Conditioning in Green Office Buildings?

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

HVAC Simplified Approach Option

ENERGY SAVINGS BY CHANGING CONSTANT AIR VOLUME SYSTEMS (CAV) TO VARIABLE AIR VOLUME SYSTEMS (VAV) IN EXISTING OFFICE BUILDINGS.

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Mechanical and Natural Ventilation

HVAC Systems: Overview

Residential HVAC System Sizing

Glossary of Heating, Ventilation and Air Conditioning Terms

Comparing Energy Savings of Different VAV Systems

HDA

Postharvest Sample Questions

Cooling Load Calculations and Principles

Air Conditioning Clinic

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

AIRCONDITIONING Cooling Loads Calculations

Building Performance Evaluation Guide Version 1.7

VE Compliance FAQ. Top Tips for Achieving Compliance

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

Fan Applications & System Guide

Why Do I Need Precision Air Conditioning?

2011 National Energy Code for Buildings: Archetype Building Analysis for Newfoundland and Labrador

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Dealing with Thermal Issues in Data Center Universal Aisle Containment

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

EN Insulating glass units, intended to be used in buildings and construction works

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

HVAC Checklist - Long Form

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Preliminary Final Proposal

Selecting the Supply Air Conditions for a Dedicated Outdoor Air System Working in Parallel with Distributed Sensible Cooling Terminal Equipment

Energy Efficiency in Buildings

APC APPLICATION NOTE #112

HVAC Systems in Schools & Commercial Buildings and Radon

ENERGY PERFORMANCE MODELLING AND HEAT RECOVERY UNIT EFFICIENCY ASSESSMENT OF AN OFFICE BUILDING

Red River College MECB 101 School of Construction and Engineering Technologies Manitoba Energy Code for Buildings 101 (MECB 101)

CIBSE Loads User Guide

Proper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems. History

University of St Andrews. Energy Efficient Data Centre Cooling

Performance Rating of Room Fan- Coils

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

CE6500 Energy Recovery Ventilator

IDA ICE 4: Getting Started EQUA Simulation AB, September 2009

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates

Transcription:

Air System Design Load Summary for Zona 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1800 HEATING DATA AT DES HTG COOLING OA DB / WB 32.4 C / 23.1 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent Sensible Latent ZONE LOADS Details (W) (W) Details (W) (W) Window & Skylight Solar Loads 0 m² 0-0 m² - - Wall Transmission 54 m² 1555-54 m² 1788 - Roof Transmission 66 m² 875-66 m² 816 - Window Transmission 0 m² 0-0 m² 0 - Skylight Transmission 0 m² 0-0 m² 0 - Door Loads 0 m² 0-0 m² 0 - Floor Transmission 66 m² 0-66 m² 0 - Partitions 63 m² 0-63 m² 0 - Ceiling 0 m² 0-0 m² 0 - Overhead Lighting 1774 W 1674-0 0 - Task Lighting 0 W 0-0 0 - Electric Equipment 5585 W 5445-0 0 - People 16 1097 987 0 0 0 Infiltration - 0 0-0 0 Miscellaneous - 0 0-0 0 Safety Factor 5% / 5% 532 49 5% 130 0 >> Total Zone Loads - 11178 1036-2734 0 Zone Conditioning - 10877 1036-2664 0 Plenum Wall Load 0% 0-0 0 - Plenum Roof Load 0% 0-0 0 - Plenum Lighting Load 0% 0-0 0 - Return Fan Load 972 L/s 0-972 L/s 0 - Ventilation Load 116 L/s 1059 1153 116 L/s 3012 0 Supply Fan Load 1047 L/s 19-1047 L/s -19 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 559-5% 137 - >> Total System Loads - 12514 2189-5794 0 Central Cooling Coil - 12514 2189-0 0 Central Heating Coil - 0 - - 5794 - >> Total Conditioning - 12514 2189-5794 0 Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are clg loads

Psychrometric Analysis for Zona 9 Location: Buenos Aires, Argentina Altitude: 19.8 m. Data for: February DESIGN COOLING DAY, 1800 1. Outdoor Air 0.0200 2. Mixed Air 3. Central Cooling Coil Outlet 4. Supply Fan Outlet 5. Duct Heat 6. Room Air 7. Return Duct Outlet 4 35 7 6 2 1 0.0175 0.0150 0.0125 0.0100 0.0075 0.0050 Specific Humidity ( kg/kg ) 0.0025 0 5 10 15 20 25 30 35 Temperature ( C ) 0.0000

Space Design Load Summary for Zona 9 TABLE 1.1.A. COMPONENT LOADS FOR SPACE '' Zona 9 '' IN ZONE '' Zone 9 '' DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1900 HEATING DATA AT DES HTG COOLING OA DB / WB 30.8 C / 22.7 C HEATING OA DB / WB -0.6 C / -3.2 C OCCUPIED T-STAT 23.9 C OCCUPIED T-STAT 21.1 C Sensible Latent Sensible Latent SPACE LOADS Details (W) (W) Details (W) (W) Window & Skylight Solar Loads 0 m² 0-0 m² - - Wall Transmission 54 m² 1552-54 m² 1788 - Roof Transmission 66 m² 986-66 m² 816 - Window Transmission 0 m² 0-0 m² 0 - Skylight Transmission 0 m² 0-0 m² 0 - Door Loads 0 m² 0-0 m² 0 - Floor Transmission 66 m² 0-66 m² 0 - Partitions 63 m² 0-63 m² 0 - Ceiling 0 m² 0-0 m² 0 - Overhead Lighting 1774 W 1681-0 0 - Task Lighting 0 W 0-0 0 - Electric Equipment 5585 W 5454-0 0 - People 16 1102 987 0 0 0 Infiltration - 0 0-0 0 Miscellaneous - 0 0-0 0 Safety Factor 5% / 5% 539 49 5% 130 0 >> Total Zone Loads - 11313 1036-2734 0 ENE EXPOSURE TABLE 1.1.B. ENVELOPE LOADS FOR SPACE '' Zona 9 '' IN ZONE '' Zone 9 '' COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (m²) (W/(m²- K)) Coeff. (W) (W) (W) WALL 54 1.529-1552 - 1788 H EXPOSURE ROOF 66 0.573-986 - 816

Air System Sizing Summary for Zona 9 Air System Information Air System Name... Zona 9 Equipment Class... SPLT AHU Air System Type... SZCAV Number of zones... 1 Floor Area... 65.7 m² Sizing Calculation Information Zone and Space Sizing Method: Zone L/s... Sum of space airflow rates Space L/s... Individual peak space loads Calculation Months... Jan to Dec Sizing Data... Calculated Central Cooling Coil Sizing Data Total coil load... 14.7 kw Sensible coil load... 12.5 kw Coil L/s at Feb 1800... 1047 L/s Max block L/s... 1047 L/s Sum of peak zone L/s... 995 L/s Sensible heat ratio... 0.851 m²/kw... 4.5 W/m²... 223.8 Water flow @ 5.6 K rise...... N/A Load occurs at... Feb 1800 OA DB / WB... 32.4 / 23.1 C Entering DB / WB... 25.4 / 18.9 C Leaving DB / WB... 15.4 / 14.8 C Coil ADP... 14.3 C Bypass Factor... 0.100 Resulting RH... 54 % Design supply temp.... 14.4 C Zone T-stat Check... 1 of 1 OK Max zone temperature deviation... 0.0 K Central Heating Coil Sizing Data Max coil load... 5.8 kw Coil L/s at Des Htg... 1047 L/s Max coil L/s... 1047 L/s Water flow @ 11.1 K drop...... N/A Load occurs at... Des Htg W/m²... 88.2 Ent. DB / Lvg DB... 18.6 / 23.2 C Supply Fan Sizing Data Actual max L/s... 1047 L/s Standard L/s... 1045 L/s Actual max L/(s-m²)... 15.94 L/(s-m²) Outdoor Ventilation Air Data Design airflow L/s... 116 L/s L/(s-m²)... 1.77 L/(s-m²) Fan motor BHP... 0.03 BHP Fan motor kw... 0.02 kw Fan static... 10 Pa l/s/person... 7.08 l/s/person

Zone Design Load Summary for Zona 9 Zone 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1900 HEATING DATA AT DES HTG COOLING OA DB / WB 30.8 C / 22.7 C HEATING OA DB / WB -0.6 C / -3.2 C OCCUPIED T-STAT 23.9 C OCCUPIED T-STAT 21.1 C Sensible Latent Sensible Latent ZONE LOADS Details (W) (W) Details (W) (W) Window & Skylight Solar Loads 0 m² 0-0 m² - - Wall Transmission 54 m² 1552-54 m² 1788 - Roof Transmission 66 m² 986-66 m² 816 - Window Transmission 0 m² 0-0 m² 0 - Skylight Transmission 0 m² 0-0 m² 0 - Door Loads 0 m² 0-0 m² 0 - Floor Transmission 66 m² 0-66 m² 0 - Partitions 63 m² 0-63 m² 0 - Ceiling 0 m² 0-0 m² 0 - Overhead Lighting 1774 W 1681-0 0 - Task Lighting 0 W 0-0 0 - Electric Equipment 5585 W 5454-0 0 - People 16 1102 987 0 0 0 Infiltration - 0 0-0 0 Miscellaneous - 0 0-0 0 Safety Factor 5% / 5% 539 49 5% 130 0 >> Total Zone Loads - 11313 1036-2734 0

Zone Sizing Summary for Zona 9 Sizing Calculation Information Zone and Space Sizing Method: Zone L/s... Sum of space airflow rates Space L/s... Individual peak space loads Calculation Months... Jan to Dec Sizing Data... Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (kw) (L/s) (L/s) Load (kw) (m²) L/(s-m²) Zone 9 11.3 995 995 Jan 1900 2.7 65.7 15.14 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult. (kw) Load (L/s) (kw) (m²) L/(s-m²) Zone 9 Zona 9 1 11.3 Jan 1900 995 2.7 65.7 15.14