ROLLING FIRE DOOR TESTING PROGRAM

Similar documents
Office of the State Fire Marshal. Fire Rated Doors

DESIGN CLARIFICATION (DC)

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Owner s Manual & Safety Instructions

STANDARD FOR NON-FIRE RATED ROLLING DOORS

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

ROLLING CURTAIN DOOR INSTALLATION, MAINTENANCE & PARTS MANUAL WINDLOCK MODEL 955WL

Owner s Manual & Safety Instructions

ANGLIA DOOR SYSTEMS LTD O&M MANUAL ROLLER SHUTTER DOOR OPERATING & MAINTENANCE INSTRUCTIONS. Page 1 of 13

DiscPlus DX195 and DX225 Air Disc Brakes

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Owner s Manual Gantry Cranes

1000-LB. TRAILER JACK OWNER S MANUAL

1 Ton Telescoping Gantry Crane

Best/Flex Roller Expandable Conveyor

PRODUCT MANUAL - M090

SECTION FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS

Andersen Electric Window Opener for Andersen Awning and Roof Windows

RZ Guardrail System Installation Manual

Information Technology Solutions

WE-350 Series ¼ Turn Electric Actuator

STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model NOTICE TO USER

Strut Spring Compressor

FORKLIFT SAFETY TIPS

How To Ensure Safety Of Lifting Equipment

lamp post light Set up and Operating Instructions

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

3/4 PIPE CLAMP WITH STAND

Roll-Up Door Maintenance Guide

Steel Door Frame Installation in Steel Stud Construction

15GAL STEEL OIL DRAIN WITH 110V PUMP

OWNER S MANUAL Table Tennis Table Patent Pending

STANDARD PRACTICE INSTRUCTION

INTRODUCTION KINGPIN REPLACEMENT

Fire Doors Basic Guidance & Checklist

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

Cooktop Low-Profile Ventilation Hoods

Housing Quality Standards Inspection Checklist

SLACK PERFORMANCE KARTS

Seatbelt Solutions

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

Fuel Injection Pump, Rotary ( )

Utility Distribution Systems

EXCAVATOR SAFETY TRAINING

SELF-STEERING AXLE TABLE OF CONTENTS

PEDAL CAR - GO CART ASSEMBLY & OPERATING INSTRUCTIONS

Chapter 7 Hydraulic System Troubleshooting

Drive shaft, servicing

12. REAR WHEEL/BRAKE/SUSPENSION

Basic Spring Motor Roller Shades

CONGRATULATIONS! TABLE OF CONTENTS. 1 Safety Warnings 2 About Your Wheels 3 Setting Up Your Wheels 7 Care and Cleaning 8 Warranty

Commercial Fire Inspections

R O A D M A S T E R, I N C.

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

HYDRAULIC LIFT TABLE CART 2200-LB.

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

HC-3000 SERIES RAKE Parts Breakdown DURABILT INDUSTRIES, LLC AIRPORT ROAD POCAHONTAS ARKANSAS 72455

NONSUCH SPARS Recommended Owner s Maintenance Schedule

ATS Overhead Table Shelf System INSTRUCTION MANUAL

WARNING! Failure to follow these inspection procedures can cause personal injury and property damage.

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

Retractable Screen. Replacement Screen Instructions

Name Of Occupancy Date. Yes No Describe

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

Street-Lynx. Reilly MotorSports, Inc. Installation Manual

TURN TABLES 1.5 TON CAPACITY / 2 PC. Model 45742

Oregon Fuel Injection

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

SAFETY & OPERATING INSTRUCTIONS

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

Owner s Manual & Safety Instructions

WARNING TO END USER, INSTALLER AND SELLER OF THIS PART!

CANTON FIRE DEPARTMENT

MAINTENANCE MANUAL RSS-3000 ELECTRIC DROP BEAM VEHICLE BARRIER

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Chelsea Loft Bed WARNING:

Active and Passive Sash Replacement

USER INSTRUCTIONS AND SPECIFICATIONS for use of SAFE APPROACH STANDING SEAM ANCHOR & SAFE APPROACH METAL ROOF SCREW-DOWN ANCHOR

6 LOADING AND UNLOADING A FLATBED

92-00 Civic/ Integra/ Del Sol/ CRX Rear Kit Part No

Asking Price: N/A Final Price: N/A OROPS BUCKET AUXILIARY HYDRAULICS GENERAL APPEARANCE. Good. Good

SUSPENSION DIAGNOSIS

Parts Manual & Service Manual

Vehicle Restraint Installation Manual

ELECTRIC KNIFE SHARPENER

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Fitting Instructions Garador, Westland & Catnic Garage Door Spring Box Roller Wheels & Wall Bracket & Link Arm

FOREWORD. Right and left as used throughout this manual are determined by facing the direction the machine will travel when in use.

60 WATT LED TRIPLE BEAM WORKLIGHT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Digital Fingerprint safe

Model 854/856. Operating and Assembly Manual. Palmor Products Inc Serum Plant Road Thorntown, IN 46071

Instructions and precautions. Fork Height. Visit our website at:

Transcription:

ROLLING FIRE DOOR TESTING PROGRAM Overhead Door Company of the Northland 3195 Terminal Drive Eagan, MN 55121 Phone # (651) 683-0307 Fax # (651) 683-0625

Inspection, Testing and Certifications per NFPA-80 Standards National Fire Protection Association (NFPA) standards require building owners to have their rolling and Sliding fire doors inspected and tested annually, and to maintain written documentation of such inspections. Overhead Door Company of the Northland s Fire Door Drop Testing (FDDT) Program helps building Owners and managers stay in compliance with the most recent NFPA-80 standards, while maintaining the Proper operation and full closure of your facility s rolling and sliding fire doors. Fire Door Drop Testing Services Include The inspection, testing and certification of your facility s rolling and sliding fire doors to meet NFPA-80 Section 15-2.4.3-5 requirements by factory trained and certified technicians. A written Fire Door Inspection and Drop Test Report, which documents each FDDT service call For your facility s records along with recommendations for any needed repairs or product replacement. See the following pages for additional detail on inspection and drop test guidelines. A Fire Door Certification tag is attached to each tested fire door indicating the date the door was inspected, tested and certified. Copies of your facilities Fire Door Inspection and Drop Test Results are kept in our company s records in case of an emergency or any compliance questions. (see sample enclosed) You will be contacted on an annual basis to schedule future FDDT service appointments to help keep your fire doors in compliance with NFPA-80 section 15-2.4.3-5 and in good working order. Fire Doors play a key role in building safety. Properly operating fire doors help protect property and save lives in the event of an emergency. Defective, damaged or non-functioning fire doors can lead to tragic results and may subject building owners and managers to catastrophic losses and increased legal liability. Overhead Door Company of the Northland s FDDT Program provides for your facilities ongoing compliance with your NFPA-80 section 15-2.4.3-5 requirements, while establishing and maintaining FDDT records for your facility on an annual basis. FDDT Program Enrollment You can enroll in the Overhead Door Company of the Northland s FDDT Testing program or get more information on this or other Preventive Maintenance contracts or services we provide by: Calling 651-683-0307 or sign up online at www.overheaddoornotrhland.com to schedule an appointment for a FREE estimate for this service.

INSPECTION AND DROP TEST GUIDELINES REFER TO THE MANUFACTURER S INSTALLATION / RESET INSTRUCTIONS AND NFPA-80 CAUTION: Every component of a door and its installation must be checked for determination of factors that may effect a door s intended operation and performance. The list below may be incomplete and is provided as a guideline only. VISUAL INSPECTION A) Proper Installation 1) Curtain, Barrel and guides are aligned, level, plumb and true. 2) Attachment to the jambs and proper bolts, washers, expansion anchors or as required. 3) Expansion Clearance. 4) Fusible link locations. B) Damaged, Incorrect or missing parts 1) Slats bent slats, cracked beads, torn ends. 2) End Locks missing, broken, bent or loose. 3) Bottom Bar Bent angles, loose bolts, correct starter slat. 4) Guide Assembly bent guides, loose bolts, missing fiber washers, bell mounts 5) Hood & Flame Baffle Bent, dented, rubbing curtain, holes, tears, attachment to wall, intermediate supports or missing fusible hood link. (when required) 6) Brackets & Operating Mechanisms worn, misaligned, or badly meshed gears, broken sprockets or bent drive / spring shafts. 7) Automatic Closing and Governor Assemblies Missing or broken parts, drop or release arms tied, blocked or jammed. 8) Fusible Links sash chain / cable, S-Hooks, eyes Fusible links painted or coated with dust or grease, kinked or pinched cable, chain twisted of no longer flexible, raceways. 9) Mounting and Assembly Bolts Missing fiber washer, loose or broken bolts. 10) Past replacement parts not from original door manufacturer homemade or mismatched slats and or bottom bar. C) Ancillary Equipment 1) Smoke detectors / release devices check batteries annually 2) Control Panel Check all functions. 3) Miscellaneous other equipment should be checked for proper operation and function. OPERATIONAL INSPECTION Roll door up and down in normal operation to check for spring tension and free movement of curtain in guides. DROP TEST If the door does not roll up and down properly in normal operation or if there are damaged or missing parts that will create a hazard or prevent proper operation or reset. THESE CONDITIONS SHOULD BE CORRECTED BEFORE CONDUCTING A DROP TEST. Drop Test per manufacturer s written instructions. Drop test should for automatic closing of the curtain at an average speed not less that 6 per second, nor more than 24 per second, and full closure of the curtain with the bottom bar resting on the sill or floor. Reset door per manufacturers written instructions. ULITMATE ACCEPTABILITY OF A FIRE DOOR IS THE DECISION OF THE AUTHORITY HAVING JURISDICTION, AS DEFINED BY NFPA-80

ROLLING DOOR DROP TEST AND INSPECTION FORM NOTE TO OWNER: NFPA-80 and Model Codes requires the annual testing of rolling fire doors to demonstrate proper operation and full closure. Resetting of release mechanism must be done in accordance with the manufacturers' instructions. A written record must be maintained and made available to the authority having jurisdiction. NFPA-80 also requires that when damaged impairs the doors proper emergency function that it be repaired with parts obtained from the original doors' manufacturer and upon completion of the repairs that the door be tested to assure emergency operation and closing. WARNING: Severe injury or death may result through improper attempts at drop testing, repairing and or maintenance Drop testing repair and or maintenance should be performed by qualified personnel with a complete knowledge and understanding of this type of door. Before drop testing, conduct a visual inspection for damage or missing parts that may create a hazard during testing of effect proper operation or resetting. Verify proper installation. Open and close the door to check for correct spring tension. COMPANY ADDRESS CONTACT PHONE DATE DOOR LOCATION: VISUAL CHECK OPERATION TEST DROP TEST DOOR SIZE MANUFACTURER SERIAL # PASS FAIL PASS FAIL PASS FAIL VISUAL INSPECTION Curtain barrel and guides are aligned, level, plumb and true Slats check for damaged, bent or torn ends. Bottom Bar bent, missing parts, properly secured to curtain assembly Guide assembly, bent angles, loose or missing bolts, missing fiber washers. Hood and flame baffle bent or damaged impeding door operation, fire link intact. Automatic closing and governing mechanisms missing, broken parts, release arms blocked or wedged. Fusible links and sash chains / links painted or covered with grease, missing or obstructed in any way. Mounting and Head Plate assembly bolts missing or loose. Smoke detectors and release devices working properly, batteries charged. (if applicable) OPERATIONAL INSPECTION Door operates freely up and down and has the proper amount of spring tension. DROP TEST Door operation dropped properly during simulated drop test. Reset door according to manufacturers' specifications. RECOMMENDED WORK The automatic release device has been tested to demonstrate proper operation and full closure. The door has been reset in accordance to manufacturers reset instructions and left in proper working condition, unless otherwise noted above. TESTED BY WITNESSED BY COMPANY REPRESENTING ADDRESS SIGNATURE RECOMMENDED WORK IS: AUTHORIZED DECLINED SIGNATURE DATE BY OVERHEAD DOOR COMPANY OF THE NORTHLAND * 3195 TERMINAL DRIVE * EAGAN * MN 55121 * 651-683-0307