EX-PROTECTED PORTABLE POWER SUPPLY UNITS

Similar documents
A good connection. International approvals.

Plug and Socket Devices CES 63 A Series 8579

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Terminal Boxes Series 8146

Linear Luminaire with LED Series EXLUX 6402/2

8146/5 Series Breaker Panelboards

Plug and Socket Devices SolConeX 16 A Series 8570

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Series 8146/5-V37 and Series 8150/5-V37

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Solenoid Valve Island Type 3965

Technical Data. Dimensions

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Transformers from 25va to 500kva. Standard despatch in days not weeks

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Technical data sheet TDS0070

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Electric Rotary Actuator - On/Off or programmable control actuator

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Terminal Box. Specifications TNCN

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Linkeo 19" freestanding cabinets

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

STB Series Enclosures

Safety instructions VEGADIS DIS81.CEIA/V****

7 Lighting Technology

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Plastic tube flowmeters Series PT/PS

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Distribution Boards & Consumer Units

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Explosion proof enclosures

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Inductive sensor NI10-M18-Y1X-H1141

Contrast 2 LED. Performance Compactness Complete flexibility NEW

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Control Stations Made of Polyester Resin Series 8146

2.12. page Products for Explosion hazardous Environment

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Instructions for Safe Use

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Threaded Resistance Thermometers Model TR10-D, Miniature Design

HERZ-Thermal Actuators

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Control and Distribution Boxes made of Stainless Steel Series 8150

Safety detection solutions

Technical Information RIA14

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Guide to enclosures for potentially explosive atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

distributing & controlling system solutions

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

R.C.C.B. s two-pole LEXIC

SITRANS F flowmeters SITRANS F M

SMS 4 / SMS 5 safety mat Product information

ELECTRICAL INSPECTION BULLETIN (Effective )

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Cable Plug acc. to DIN EN , Form A

Product Information Sheet UH28CS-12kV Hi Pot Tester

Vario-Series Accessories

RUBBER SLEEVE KNIFE GATE VALVE

Morgue refrigeration unit

Solenoid Valve Type 3962

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Assisted lift operated 2/2-way solenoid valves Type EV250B

Differential-Hall-Effect based Sensors Series A5S

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

How can a charging station for electric vehicles be set up simply and safely?

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Operating Instructions

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Abtech Custom Solutions

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

ASSEMBLED SOCKET-COMBINATIONS

TEIP11 I/P signal converter for standard signals. Measurement made easy

H45 LED - Direct and indirect pendant

CONSULTING Training Courses

Operating Instructions

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

Flameproof Audible Signal 115 db (A) Series YA90

Crane control unit KST 3

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Transcription:

EX-PROTECTED PORTABLE POWER SUPPLY UNTS 6 A 25 A for Zone Special requirements apply for power distributions for the use and operation of portable equipment in hazardous areas in Zones, 2, 2 and 22. t is necessary to ensure that any external mechanical influences are effectively kept away from the equipment. CEAG explosion-protected power distributions fulfil these high mechanical explosion protection requirements by means of a high-strength protective framework made of stainless steel (.430) and enclosures that have been specially developed for this purpose. Whether in accordance with customer requirements or as a series product, sizes 6 A 25 A are possible. All the electrical outgoing circuits can be fitted with separate MCBs or ELCBs. Customized components, such as electronic subassemblies, can also be safely built into special, flameproof enclosures with the required Certificate of Conformity. The power distributions are fitted with flange sockets that fulfil the high requirements of the degree of protection P 66, even with plugs inserted. Thus, these distributions are even suitable for use under most extreme industrial conditions. For the additional connection to the protective conductor (PE) or equipotential bonding conductor (PA), there is a stud welded directly onto the framework. nternational approvals. Flexible power distribution in the hazardous area thanks to sockets with lamellar contacts for optimum contact safety Padlocking of switch with all-pole disconnection and full AC3 switching capacity High mechanical, chemical and thermal resistance Customer specific design 2..06 EATON S CROUSE-HNDS BUSNESS

Ex-protected portable power supply units EXKO 23320 A005 Ex-protected portable power supply unit EXKO 2 G Ex de C T4 / 2 D Ex td A2 T95 C EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C up to +40 C 400 V / 230 V 63 A 50-60 Hz 63A gl / gg x M50 Trumpet shaped cable gland Enclosure material sheet steel, painted (option stainless steel AS 36L) metal frame stainless steel, squared 20 x 20 x 2 including lockable wheels 968 x 800 x 600 mm Enclosure colour RAL 7032 x MCB 4-pole - C40A, 0kA x Plug 63A 5-pole, 06h (GHG547506R000) x RCD 4-pole - 40A 0.03A 0kA x Wall socket 63A 5-pole, 06h (GHG544506R000) x RCD 4-pole - 63A 0.03A, 0kA 3x Flange socket 32A 5-pole, 06h (GHG528506R000) 3x RCD with overcurrent protection 6x Flange socket 6A 3-pole, 06h (GHG58306R000) (-pole+n, C6A/0.03, 0kA) actuating flap for components 3x MCB 4-pole - C32A, 0kA EXKO 23320 A005 Enclosure material stainless steel AS 36L 75 75 75 75 770 770 986 874 986 874 3 m H07 RN-F 5G 25 mm² potential equalisation connection bolt (M8 x 30) 600 3 m H07 RN-F 5G 25 mm² 600 800 800 GHG547506R000 GHG547406R000 EATON S CROUSE-HNDS BUSNESS 2..07

Ex-protected portable power supply units Ex-protected portable power supply unit EXKO 23320 A006 2 G Ex de C T4 / 2 D T95 C EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C to +40 C 400 V / 230 V 32 A 32 A gl / gg x M32 Trumpet shaped cable gland, x M2 cable gland plastic Connecting cable H07RN-F 5 x 6mm² with plug 32A, 3 m Enclosure material Sheet steel, painted (optional: stainless steel AS 36L), Metal frame stainless steel squared 20 x 20 x 2 including lockable wheels 09 x 800 x 600 mm 69 kg Enclosure colour RAL 7032 x MCB S204M - C32A, 0kA x RCD F204A - 40A 0.03A 0kA 3x RCBO DS97 - C6A 0.03A, 0kA x Plug 32A 5-pole, 380-45V (06h) (GHG527506R000) x Flange socket 32A 5-pole, 380-45V (06h ) (GHG528506R000) 6x Flange socket 6A 3-pole, 230V (06h) (GHG58306R000) actuating flap for components EXKO 23320 A006 Enclosure material stainless steel AS 36L 75 75 803 09 874 3 m H07 RN-F 5G 6 mm² 800 potential equalisation connection bolt (M8 x 30) 600 2..08 EATON S CROUSE-HNDS BUSNESS

Ex-protected portable power supply units Ex-protected portable power supply unit EXKO 23320 A0006 2 G Ex de C T4 EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C to +40 C 230/24 V transformer, 00 VA 6 A 6 A gl / gg x M25 Trumpet shaped cable gland, x M2 cable gland plastic Enclosure material glass-fibre reinforced polyester (option sheet steel, painted or stainless steel AS 36L) Metal frame stainless steel squared 20 x 20 x 2 with wheels 062 x 500 x 336 mm 30 kg Enclosure colour black x MCB S202M - K0.5A, 0kA 2x Flange socket x RCBO DS97 - C4A 0.03A, 0kA 6A 3-pole, 24V (GHG5420007R0003 x transformer 230/24V 00VA actuating flap for components EXKO 23320 A0006 Enclosure material stainless steel AS 36L 062 500 336 EATON S CROUSE-HNDS BUSNESS 2..09

Ex-protected portable power supply units Ex-protected portable power supply unit EXKO 23320 A0007 2 G Ex de C T4 EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C up to +40 C 0/24 V transformer, 500 VA 6 A 25A gl / gg x M25 Trumpet shaped cable gland, x M2 cable gland plastic Enclosure material glass-fibre reinforced polyester (option sheet steel, painted or stainless steel AS 36L) Metal frame stainless steel squared 20 x 20 x 2 with wheels 062 x 774 x 336 mm 44 kg Enclosure colour black x MCB S202P - K6A, 0kA x Flange socket 6A 3-pole, 0V (GHG58304R000) 2x MCB S202M - C6A, 0kA 2x Flange socket 6A 2polig, 24V (GHG5420007R0004) x transformer 0/24V 550VA actuating flap for components EXKO 23320 A0007 Enclosure material stainless steel AS 36L 062 774 336 2..0 EATON S CROUSE-HNDS BUSNESS

Ex-protected portable power supply units Ex-protected portable power supply unit EXKO 23320 A004 2 G Ex de C T4 EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C up to +40 C 230/42 V transformer, 550 VA 6 A 50-60 Hz 6 A gl / gg x M25 Trumpet shaped cable gland, x M2 cable gland plastic Connecting cable H07RN-F 3 x.5 mm² with plug 6A, 3 m Enclosure material glass-fibre reinforced polyester (option sheet steel, painted or stainless steel AS 36L) Metal frame stainless steel squared 20 x 20 x 2 with wheels 062 x 500 x 336 mm 40 kg Enclosure colour black x MCB S202P - K3A, 0kA 2 x Flange socket 6 A 2-pole, 42 V (GHG5420007R0002) x MCB S202M - C0A, 0kA x Plug 6 A 3-pole, 230 V 06 h (GHG57306R000) x transformer 230/42V 550VA actuating flap for components EXKO 23320 A004 Enclosure material stainless steel AS 36L 062 0 m H07RN-F 3G.5 mm² 500 336 EATON S CROUSE-HNDS BUSNESS 2..

Ex-protected portable power supply units EXKO 23320 A009 Ex-protected portable power supply unit EXKO 23320 A009 2 G Ex de C T4 EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C up to +55 C 240/42 V transformer, 400 VA 6 A 6 A gl / gg x M32 Trumpet shaped cable gland, x M2 cable gland plastic Enclosure material Sheet steel (option stainless steel AS 36L) Metal frame stainless steel squared 20 x 20 x 2 with wheels 064 x 62 x 336 mm 38 kg Enclosure colour RAL 7032 x MCB S202M - K6A, 0kA 4x Flange socket 6A 3-pole, 24V (GHG5425300V0000) x Ex-d Sicherung 2x T 2A 4x Plug 6A 3-pole, 24V (GHG5422300V0000) x transformer 240/24V 400VA actuating flap for components EXKO 23320 A009 Enclosure material stainless steel AS 36L 393 064 62 336 2..2 EATON S CROUSE-HNDS BUSNESS

Ex-protected portable power supply units EXKO 23320 A002 Ex-protected portable power supply unit EXKO 23320 A002 2 G Ex de C T4 / 2 D T95 C EC-Type Examination Certificate PTB 99 ATEX 044 Permissible ambient temperature -20 C to +40 C 207 V / 20 V 32 A 63 A gl / gg x M40 Trumpet shaped cable gland, x M2 cable gland plastic Connecting cable H07RN-F 5 x 0 mm 2 without plug, 0 m Enclosure material Plastic, metal plate AS 304L Metal frame 378 x 594 x 23 mm 25 kg Enclosure colour black x MCB S202M - C32A, 0kA 3x Wall socket 6A 3-pole, 20V (04h ) (GHG58304R000) 3x Fi-LS DS97 - C6A 0.03A, 6kA actuating flap for components EXKO 23320 A002 Enclosure material stainless steel AS 36L 594 23 378 327 EATON S CROUSE-HNDS BUSNESS 2..3

Ex-protected portable power supply units Ex-protected portable power supply unit EXKO 23320 A0025 2 G Ex de C T4 EC-Type Examination Certificate PTB 99 ATEX 057 Permissible ambient temperature -20 C to +40 C 230/24 V transformer, 400 VA 6 A 6 A gl / gg x M25 Trumpet shaped cable gland, x M2 cable gland plastic connecting cable H07RN-F 3 x 2.5 mm² with plug 6 A, 3 m Enclosure material Ex-d enclosure: die-cast aluminium, connection box: stainless steel AS 36L Metal frame stainless steel squared 20 x 20 x 2 including lockable wheels 936 x 720 x 369 mm 62 kg Enclosure colour RAL 7032 x MCB S202M - C0A, 0kA x Plug 6A 3-pole, 230V (06h) (GHG57306R000) x MCB S202M - C3A, 0kA 4x Wall socket 6A 3-pole, 24V (0h ) (GHG5830R000) x power supply 230V AC / 24V DC 20A actuating flap for components EXKO 23320 A0025 Enclosure material stainless steel AS 36L 3m H07 RN-F 3G 2.5 mm² 936 potential equalisation connection bolt (M8 x 30) GHG57306R000 6 A, 3-pole, 230 V 720 369 2..4 EATON S CROUSE-HNDS BUSNESS