JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

Similar documents
Series description: Wilo-Drain TC 40

Conlift1, Conlift2, Conlift2 ph+

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

1. Description. 2. List of Accessories included A B C F G H

Please also see 10 golden rules for correct Saniflo installation on

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ACO Building Drainage

Series description: Wilo-Yonos MAXO

lifting stations motralec

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

Series description: Wilo-Yonos MAXO-D

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Vertical selfpriming Side-Channel Pumps Type WPV

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

CRN A-F-G-E-HQQE 3x400D 50 HZ

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

CRK A-W-A-BUBV

ECOCIAT. Domestic hot water heat recovery unit

Series description: Wilo-Star-Z

MODEL INSTALLATION INSTRUCTIONS

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Power consumption (kw)

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Fire Pump Plan Review March 2010

VAG Non-Return Valves

Tsurumi BER. Submersible Ejectors

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Butterfly Valves PN 6/10/16 for flanged connection

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Oil and Coolant Circulating Heating System. Model - OCSM

Vacuum drying oven for non-flammable solvents

Type overview. Technical data

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Manual piston sampler...m 11

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Model 1210C Battery Powered Pump Shown. Description

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Refrigeration Compressed Air Dryer Buran Ultrapulse

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

HERZ-Thermal Actuators

SJT / SJM / SJP Large Vertical Pumps

TELESCOPE Motorized Lighting Suspension

LC/LCD ranges level controllers

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Digital inductive conductivity transmitter

Operation Manual. Trash Water Pump - ARTIKEL Read and follow the operating instructions and safety information before using for the first time.

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

MEMBRANE VACUUM MINI PUMPS

swimming pool accessories

Jay R. Smith Mfg. Co.

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Electric Rotary Actuator - On/Off or programmable control actuator

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Multistage high-pressure multistage centrifugal pumps

Catalogue Wilo- Stratos PARA

Incubator with mechanical convection

Direct steam injection humidifiers

Hydraulic Control Solutions

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

SunMaxx Solar Filling Station Operating Instructions

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

TFSR & TFSK Roof Fans

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Rules for Classification and Construction Additional Rules and Guidelines

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

PS1800 Centrifugal Pumping Systems

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Overview of types. Technical data

Operators manual Basic water heater

The conditions below apply to the curves shown on the following pages.

GENIX AUTOMATIC LIFTING STATIONS

Heating, air-conditioning, cooling

Assisted lift operated 2/2-way solenoid valves Type EV250B

Duplex Filters 40 FLDK 0008(C)-0120(C)

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

Fluxi 2000/TZ Turbine Gas Meter

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

How To Use A Flowmeter

Transcription:

APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In order to ensure a practical arrangement, special importance was attached to easy installation. The submersible unit is permitted for general use in areas subject to flooding without requiring additional outlay. The control unit has to be fitted in a well ventilated flood-proof room. The construction with PE tanks has freely accessible drains and a clamp-type inlet flange for easy installation. The topmounted cleaning opening and the easy replaceability of the pre-mounted pumps also ensure time-saving servicing. For application areas with special obligations for fire protection like airports or underground railways we recommend our sewage liftings stations in stainless steel on request. Submersible Large storage capacity Selectable inlet position PE-tank compli 1500 compli 2500 PERFORMANCE PERFORMANCE Operative limit Discharge pipe DN100 Single channel impeller 50Hz 2800RPM Discharge DN80/DN100 23695-02 45220-02 We reserve the right to change specifications without notice Pump performance is subject to ISO 9906 tolerances The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056. This data is represented in the performance curve as a limit of application. D 204-4.4-EN-1607 1

Type Tank capacity l Inlet height mm Free passage mm Clamp-type inlet flange Connecting flange PN 10 For connecting pipe Ventilation Weight approx. Code No. Duplex system with one tank compli 1525/4 C1 500 700 100 DN 150 DN 100 DN 100 DN 70 253.5 kg JP09181 compli 1535/4 C1 500 700 100 DN 150 DN 100 DN 100 DN 70 261.5 kg JP09182 compli 1555/4 C5 500 700 100 DN 150 DN 100 DN 100 DN 70 363.5 kg JP09183 compli 1575/4 C5 500 700 100 DN 150 DN 100 DN 100 DN 70 373.5 kg JP09184 compli 1575/4 B6 500 700 70 DN 150 DN 100 DN 100 DN 70 357.5 kg JP09185 compli 1535/2 B2 500 700 70 DN 150 DN 80 DN 100 DN 70 235.5 kg JP45933 compli 1555/2 B2 500 700 70 DN 150 DN 80 DN 100 DN 70 301.5 kg JP45934 compli 1575/2 B5 500 700 70 DN 150 DN 80 DN 100 DN 70 321.5 kg JP45141 compli 15100/2 B5 500 700 70 DN 150 DN 80 DN 100 DN 70 367.5 kg JP45142 compli 15200/2 B6 500 700 70 DN 150 DN 100 DN 100 DN 70 549.5 kg JP45935 Duplex system with two tanks compli 2525/4 C1 1000 700 100 DN 150 DN 100 DN 100 DN 70 300.5 kg JP09186 compli 2535/4 C1 1000 700 100 DN 150 DN 100 DN 100 DN 70 308.5 kg JP09187 compli 2555/4 C5 1000 700 100 DN 150 DN 100 DN 100 DN 70 410.5 kg JP09188 compli 2575/4 C5 1000 700 100 DN 150 DN 100 DN 100 DN 70 420.5 kg JP09189 compli 2575/4 B6 1000 700 70 DN 150 DN 100 DN 100 DN 70 404.5 kg JP09190 compli 2535/2 B2 1000 700 70 DN 150 DN 80 DN 100 DN 70 282.5 kg JP45936 compli 2555/2 B2 1000 700 70 DN 150 DN 80 DN 100 DN 70 348.5 kg JP45937 compli 2575/2 B5 1000 700 70 DN 150 DN 80 DN 100 DN 70 368.5 kg JP45938 compli 25100/2 B5 1000 700 70 DN 150 DN 80 DN 100 DN 70 414.5 kg JP45939 compli 25200/2 B6 1000 700 70 DN 150 DN 100 DN 100 DN 70 596.5 kg JP45940 PERFORMANCE Type Delivery head H [m] 4 5 6 7 8 9 10 11 12 13 14 16 18 20 compli...25/4 C1 Flow rate Q [m 3 /h] 104 87 71 51 32 16 compli...35/4 C1 103 89 72 54 36 21 compli...55/4 C5 100 87 74 59 45 22 compli...75/4 C5 100 87 75 44 22 compli...75/4 B6 91 82 62 41 24 Type Delivery head H [m] 5 6 7 8 9 10 13 16 19 22 25 28 31 34 37 40 42 47 compli...35/2 B2 Flow rate Q [m 3 /h] 103 97 89 81 73 65 40 16 compli...55/2 B2 103 97 91 85 78 58 37 18 compli...75/2 B5 104 88 71 54 37 23 11 compli 100/2 B5 91 76 55 41 32 15 4 compli 200/2 B6 100 86 73 58 43 33 15 ELECTRICAL DATA Type Type of Voltage Motor rating kw Current RPM Cable quality Cable current Volt P1 P2 Ampere min-1 H07RN-Fcompli length...25/4 C1 3-phase 3/N/PE~400 2.4 1.90 4.2 1395 6 G 1.5 10 m compli...35/4 C1 3-phase 3/N/PE~400 3.5 2.65 6.9 1424 6 G 1.5 10 m compli...55/4 C5 3-phase 3/N/PE~400 5.8 4.65 10.2 / 5.9 1430 10 G 2.5 10 m compli...75/4 C5 3-phase 3/N/PE~400 7.2 5.90 12.8 / 7.4 1432 10 G 2.5 10 m compli...75/4 B6 3-phase 3/N/PE~400 7.2 5.90 12.8 / 7.4 1432 10 G 2.5 10 m compli...35/2 B2 3-phase 3/N/PE~400 3.7 3.04 11.5 / 6.6 2895 6 G 1.5 10 m compli...55/2 B2 3-phase 3/N/PE~400 5.2 4.45 8.7 / 5.0 2910 10 G 2.5 10 m compli...75/2 B5 3-phase 3/N/PE~400 7.7 6.60 13.2 / 7.7 2925 10 G 2.5 10 m compli 100/2 B5 3-phase 3/N/PE~400 10.5 9.20 17.6 / 10.2 2920 10 G 2.5 10 m compli 200/2 B6 3-phase 3/N/PE~400 17.3 15.4 28.8 / 16.7 2940 10 G 2.5 10 m 2

ACCESSORIES Code No. 1 2 3 Seal leak detector DKG In case of duplex systems two units have to be taken into consideration. Rechargeable battery for control for mains-independent alarm Sluice valve with two pipe sockets for 6 inlet and tank connection (DN 150) H B E F D 660 450 110 105 160 JP44900 JP44850 JP28591 4 Maintenance valve with pipe socket (DN 100) H B E F D 300 295 60 81 174 JP45173 5 Sluice valve* for 4 pressure side (DN 100), PN 10, DIN EN 1171 H B E D 345 190 DN 100 for 4 pressure side JP00329 6 Swing-type check valve R 101* PN 4, flange PN 10, DIN 3202, DIN EN 12050-4 without counterweight Swing-type check valve R 100 G* PN 4, flange PN 10, DIN 3202, DIN EN 12050-4 with adjustable counterweight H D/DN 300 100 JP00325 JP00324 7 Hand diaphragm pump for emergency purposes (up to H geod 15 m) H E D ca. 640 430 1½ JP00255 8 Stop valve, 1½ (DN 40), PN 16 9 Elastic connection 1½ (DN 40), PN 4 H B D 125 max. 60 1½ H D 120 50 JP44786 JP44777 10 Clamp 1½ JP44763 11 Flanged connection* (similar to Q unit 90 ), C 100 (similar to Q-Stück 90 ), B 80 für B5, B2 H B C/DN D/DN 175 120 100 PN 10 100 PN 6 150 100 80 PN 10 80 PN 6 JP00579 JP00578 12 Y-ducting* DN 100/100/100, PN 10 (only for compli 1500) H B C/DN D/DN 355 480 100 100 JP00203 13 Flanged spigot F-KS* for pressure side, DN 100, plastic pipe Welded connection* (F unit), for pressure side, C 100, steel pipe Elastic connection 4" (DN 100), PN 4 for pressure side, DN 100, plastic pipe H D C/DN Flansch 153 110 100 PN 10 JP08673 100 114 100 PN 10 JP00688 H D JP44778 200 110 14 H D for pressure side, DN 100, steel pipe JP44774 200 114 15 Clamp 4 JP44767 16 Reducing adapter* for B5, B2 (similar to FFR-piece to PN 10) H C/DN D/DN 100 80 100 JP00498 17 Tank, 500 l JP45945 * with screws and seal 3

Dimensions compli 1500 (mm) Dimensions compli 2500 (mm) 43009-04 43010-02 In case of a chamber, plan 60 cm working space around all parts which have to be serviced. In case of a chamber, plan 60 cm working space around all parts which have to be serviced. Mounting dimensions compli 1500 (mm) Mounting dimensions compli 2500 (mm) casing casing 20778-05 20779-04 4

Mounting arrangement of compli 1500 Mounting arrangement of compli 2500 to be provided at site 22529-04 22530-04 Mounting arrangement of compli 1500 Mounting arrangement of compli 2500 45106-00 45107-00 5

TECHNICAL DATA Pump Vertical, single-stage, submersible, single-vane impeller with spiral housing and horizontal outlet flanged on to a stable duckfoot bend as well as low-noise and low-vibration absorber. Bearing Common shaft for pump and motor, grease-packed ball bearing. Motor Submersible, IP 68 type of protection, insulation class F, winding thermostats for the protection of the drives against overheating, automatic start-up by three-contact circuit and control, operating mode S3 in keeping with VDE. Seal Silicon-carbide mechanical seal independent of the sense of rotation, oil chamber and artificial carbon mechanical seal (or duplex rotary shaft seal) to motor compartment, safe to run dry, connection options for seal leak detector. Materials Tank made of corrosion-resistant and environmentally friendly polyethylene, pump and motor housing, impeller and duckfoot bend made of wear-resistant grey cast iron, shaft completely covered against the material to be transported, rubber insulated hose. Scope of supply Tank system in keeping with German / international standard DIN EN 12050 in assembly groups, prepared for final assembly on site: Tank with clamp-type flange DN 150, two mounted submersible pumps and automatic level control, duckfoot bend, mounting material, elastic connections for the DN 70 ventilation and duckfoot bend connections with clamps, control with motor protection for automatic two-way connection with mains-dependent alarm system, potential-free contact for collective failure messages, hand-0-automatic switch and optical display of sense of rotation, alarm and operation. To be fitted with a micro-processor control as well upon request. Cable between pump and control 10 m. Accessories to be ordered according to mounting drawing. Mounting arrangement with additional tank Mounting arrangement 20894-03 45999-00 In keeping with the construction and testing principles of German / European standard DIN EN 12050, sewage disposal units are to be used for the transport of faecal matter and domestic waste-water in building drainage systems as described in German standard DIN 1986 T3. In keeping with the stipulations of German / European standard DIN EN 12056-4 they have to be mounted with collecting tanks inside building permitting a free space of 60 cm for operation and repair. The pressure pipe has to be passed above the locally defined backpressure level and a non-return valve tested in keeping with German / European standard 12050-4 has to be mounted. In keeping with German / European standard 12056 the ventilation pipe has to be passed up to the roof. 6 Jung Pumpen GmbH Industriestr. 4-6 33803 Steinhagen Germany Phone +49 5204 17-0 Fax +49 5204 80368 email: info@jung-pumpen.de