ACO Building Drainage

Size: px
Start display at page:

Download "ACO Building Drainage"

Transcription

1 ACO Building Drainage Backflow systems Backflow systems 33 Stop that backflow ACO backflow stops and lifting plant

2 Contents Background What causes backflow?... 3 Liability aspects... 3 The backflow level... 4 Installation principles and type classification... 5 Selection criteria for backflow safety valves... 6 Product line Cellar drain with backflow stop... 8 Type 2 backflow stop with shaft system...10 Type 2 backflow stop for unenclosed pipes Type 3F black water automatic backflow stop with shaft system Type 3F black water automatic backflow stop for unenclosed pipes Optional components and accessories for backflow stops Backflow stop DN Mini lifting plant for wastewater free of faeces (underground) Lifting plant for wastewater free of faeces (above-floor) Lifting plant for black water (free standing installation) Pump station load class A 15 for wastewater containing faeces (mono/duo) Pump station load class B 125 for wastewater containing faeces (mono/duo) Pump station load class D 400 for wastewater containing faeces (mono/duo)... 31

3 Background What causes backflow? Wastewater can backflow into buildings whenever wastewater can no longer drain off optimally into the public sewers. The dimensioning of drainage installations today takes into consideration economic aspects and selfcleaning effects based on average rainfall events. However, heavy rainfall which exceeds the reference rainfall level can also occur. This means that the drainage installations can be overloaded at any time. In addition to periods of heavy rainfall, wastewater can also be prevented from draining off as quickly as required by unwanted reductions in pipe cross sections caused by deposits or blockages in sewer pipes, not to mention cracked pipes, pump failures in public sewers, and floods all can lead to sewage backflowing into a building. Levels are rising The flood on the River Oder in 1997, the Whitsun flood, the Flood of the millennium in 2002 on the Elbe and its tributaries, the major flooding in the Alps in 2005, and the extraordinary amount of snow in East Bavaria in February 2006 all point in one direction: extreme floods and heavy rain and snow falls are increasing across the whole of Europe. And they will become even more frequent in future. Flooding is basically a combination of two factors: water input and surface area. The first has increased: more heavy rainfall. The second has decreased: less unpaved and unbuilt-up areas. Paradoxically, the construction of flood prevention dikes on rivers has already increased the frequency of flooding. Scientists at the Max Planck Institute for Meteorology have observed a long term trend since the middle of the 70s of an increase in flood events affecting numerous rivers in west and south Germany and neighbouring countries. Even if these rivers do no break their banks, there is always a risk that sudden heavy rainfall can affect already overloaded sewers which are often only designed to handle average rainfall events. If the capacity of the sewer shafts is exceeded, wastewater follows the natural law of communicating pipes: it flows back into buildings. To prevent backflow, drainage installations below the backflow level have to be properly protected. 3 Local authorities are not liable for extraordinary floods or rainfall Home owners can no longer rely on the public sewers during extreme rainfall events. If water flows out of sewers during floods of the century, and causes damage to private homes, local authorities cannot be held liable according to the decision handed down by the German Federal Court of Justice (BGH) in Karlsruhe. Local authorities can claim force majeure under such circumstances. Although local authorities are responsible for the safe operation of the sewer system and are responsible for any damage caused during normal conditions, this no longer applies to completely unusual and rare disastrous rainfall, according to the BGH. Their justification is that liability for risks associated with pipe networks are limited by the economic strength of the local authorities. Extra costs for wider pipes have to stay within reasonable proportion to the additional protection provided by such measures. No fixed limit has been defined. It is clear however that local authorities no longer have to dimension their systems to cope with rain which occurs more rarely than every 100 years. This decision handed down in May 2004 strengthens the hand of local authorities who stipulate that landowners bear sole responsibility for protecting their property against backflow.

4 Background Backflow level Backflow level 4 The backflow level is the highest level (water level) to which wastewater can rise in a drainage installation. The backflow level is defined by the local authority (local bylaws). In the absence of any specific definition, the backflow level is usually taken as the level of the road above the sewer connections. All drainage installations below this level are at risk of backflow and should therefore be protected by implementing the appropriate measures.

5 Background Installation principles for backflow safety valves Incorrect Correct Drainage installations which lie above the backflow level (figure left) must not be connected to a backflow safety valve (lifting plant or backflow stop). This is because it would prevent wastewater draining off properly from installations above the backflow level during a backflow situation. According to the principle of communicating pipes, the wastewater would first flow up out of the deepest lying drains below the backflow level and flood the cellar. This is why all drainage installations installed above the backflow level must be connected to the sewer downstream of the backflow stops (figure right). During a backflow event, the down pipe will not fill higher than the level of the street, and the backflow stop prevents the wastewater backing up into deeper lying drainage installations instead it forces it to rise up through the manhole cover of the sewers. Type classification of backflow stops pursuant to EN Type Installation Automatic seal Emergency seal Area of application 0 Horizontal pipe 1 0 rain water installations 1 Horizontal pipe 1 1* rain water installations 2 Horizontal pipe 2 1* rain water installations/ wastewater free of faeces 3 Horizontal pipe 1 (pneumatic 1 wastewater free faeces, wasteor electric) water containing faeces (designated "F") 4 Fitted in floor drains 1 1* wastewater free of faeces 5 Fitted in floor drains 2 1* wastewater free of faeces 5 * Emergency seal can be combined with an automatic seal. The use of different types is regulated by national law. The following table defines the specific authorisations applying to Germany, Austria and Switzerland. Country Differences Germany Austria Switzerland Types 2, 3 and 5 are authorised for wastewater free of faeces. Only Type 3 with designation F can be used for wastewater containing faeces. Types 0 to 5 are authorised for use with wastewater free of faeces. Only Type 3 can be used for wastewater con taining faeces. Backflow stops can only be used subject to prior case-by-case authorisation.

6 Which backflow safety valve is best for which application? Wastewater type Wastewater outflow Down gradient into the sewers No gradient to the sewers backflow level backflow level Wastewater free of faeces ACO Junior Cellar drain with Type 5 backflow stop ACO Sinkamat-K Underground (top) or above ground (below) lifting plant for wastewater free of faeces 6 ACO Triplex-K Backflow stop for continuous pipe Type 2 Wastewater containing faeces ACO Quatrix-K Backflow stop for continuous pipes Type 3F ACO Muli-Star MDS1/MWS1 Lifting plant for wastewater containing faeces

7 The benefits of ACO Triplex-K backflow safety valves and Quatrix-K using the shaft system Extensions for deeper installation If a backflow stop has to be installed at a much deeper level for structural reasons, it is easy to convert the ACO backflow safety valve shaft systems with the optional extensions. It is also easy to manually put together several extensions if required. Sealing flange for pressurised water If the floor plate needs to be protected against pressurised water, it is possible to equip the shaft system with an optional sealing flange. This flange provides reliable protection to keep the soil moisture out of the cellar. The height of the flange is infinitely adjustable for easy adaptation to the level of the floor plate. Adjustment to the tile pattern and floor level The top section for load class K3 is infinitely height adjustable and tiltable. This allows the cover to be perfectly adjusted to the floor height and the tile pattern. A specially adapted locking system also prevents small children from removing the cover. 7 Multi-option cover to suit customer s requirements Use either side of the cover as required. The uniform side is a plastic cover. If tiles are laid in the installation room, turn the cover round and use the side which is recessed to accommodate the matching tiles.

8 The ACO Junior cellar drain with backflow stop The ACO Junior cellar drain with backflow stop is a Type 5 backflow stop in accordance with EN Because of its compact dimensions, this cellar drain is ideal for refurbishing cellars where the drainage systems are being upgraded by installing a backflow stop in one of the old drains. The ACO Junior cellar drain with backflow stop has two flaps including an emergency seal. It is installed in the floor plate. Wastewater enters the drain via the grating. It is also possible to connect drainage installations to the drain, such as showers, washing machines or sinks lying beneath the backflow level, by adding a DN 50 inlet to the drain on site. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is backflow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The emergency seal integrated into the second flap provides additional security and can be operated manually. Note that when the emergency seal is locked in position, it also prevents wastewater generated in the building from flowing into the sewer. It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. 8 Product benefits Compact dimensions ideal for refurbishment No tools required to assemble and dismantle the sludge bucket and backflow device Rotatable top section for optimal adjustment to the tile pattern Extensions available for flexible adjustment to deeper installation positions Installation example ACO Junior cellar drain with backflow stop DN 100 Type 5 pursuant to EN

9 Article description ACO Junior cellar drain with backflow stop, DN 100 Type 5 pursuant to EN 13564, Made of plastic with removable sludge bucket and odour trap, 60 mm water trap. Shut off unit with two backflow flaps and a manually lockable emergency seal, top section made of plastic with frame dimensions 197 x 197 m and grey grating class K3. Outlet socket DN 100 with 1.5º socket slope for connection to plastic pipes pursuant to DIN and DIN Drain performance: 1.6 l/s Weight: approx. 1.2 kg Article Article-Nr. DN H1 H2 L ACO Junior Inlet socket Extension, Height 130 mm ACO maintenance kit H1 95 DN H2 1, L

10 ACO Triplex-K-2 double backflow stop with shaft system The ACO Triplex-K-2 backflow stop is a Type 2 backflow safety valve pursuant to EN This product has been specially designed for installation in floor plates. The backflow stop can be equipped with a sealing flange against pressurised water. The ACO Triplex-K-2 is specified for use with wastewater free of faeces. It must only be connected to drainage installations generating wastewater free of faeces, e.g. floor drains, showers or washing machines located below the backflow level. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is backflow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The ACO Triplex-K-2 also has an emergency seal. This is integrated within the rear flap. This is an additional safety feature and is actuated manually. The emergency seal can be easily actuated without a great deal of force and is safely in position when a loud click is heard. Note that when the emergency seal is locked in position, it also prevents wastewater generated in the building from flowing into the sewer. It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. 10 Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Easily convertible to an automatic backflow stop for wastewater containing faeces Installation example ACO Triplex-K-2 double backflow stop, DN 100 Type 2 pursuant to EN for installation within floor plates. Figure shows Triplex-K-2 with optional sealing flange to protect the device against pressurised water.

11 Article description ACO Triplex-K-2 double backflow stop, DN 100/125/150 Type 2 pursuant to EN for installation in floor plates. With telescopic, adjustable top section and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For wastewater free of faeces (grey water), for installation in pipe systems, gradient 12 mm, with two automatically closing backflow flaps, with integrated emergency seal. Safe manual locking with audible click signal when locked, with cleaning and maintenance opening and inspection pipe. Convertible to automatic Type 3F backflow stop for use with wastewater containing faeces pursuant to DIN EN Weight 6.5 kg Article No. DN Ø (mm) L (mm) H1 H2 H min H max For optional components and accessories see page 18/19. Note: If upgrading is planned some time in the future, make sure that allowance is made for the following dimension, H min : 460 mm 11 D H2 H min. H max. H D 30 L 12 Ø x300

12 ACO Triplex-K-2 double backflow stop The ACO Triplex-K-2 double backflow stop corresponds to Type 2 EN This product is specially designed for installation in an unenclosed wastewater pipe. This backflow stop is naturally also suitable for subsequent installation in existing shafts thanks to its compact dimensions. This backflow stop is specified for use with wastewater free of faeces. It must only be connected to drainage installations generating wastewater free of faeces, e.g. floor drains, showers or washing machines located below the backflow level. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is backflow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The ACO Triplex-K-2 also has an emergency seal. This is integrated within the rear flap. This is an additional safety feature and is actuated manually. The emergency seal can be easily actuated without a great deal of force and is safely in position when a loud click is heard. Note that when the emergency seal is locked in position, it also prevents wastewater generated in the building from flowing into the sewer. It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Easily convertible to an automatic backflow stop for wastewater containing faeces 12 Installation example ACO Triplex-K-2 double backflow stop, DN 100 Type 2 pursuant to EN for installation in unenclosed pipes.

13 Article description ACO Triplex-K-2 double backflow stop, DN 100/125/150 Type 2 pursuant to EN for installation in unenclosed drainpipes. For wastewater free of faeces (grey water), For installation in pipe systems, gradient 12 mm, with two automatically closing backflow flaps, with integrated emergency seal. Safe manual locking with audible click signal when locked, with cleaning and maintenance opening and inspection pipe. Convertible to automatic Type 3F backflow stop for use with wastewater containing faeces pursuant to EN Weight 3.5 kg Article No. DN Ø (mm) L (mm) H (mm) For optional components and accessories see page 18/19. H1 D D L

14 ACO Quatrix-K black water automatic backflow stop with shaft 14 The ACO Quatrix-K black water automatic backflow stop corresponds to Type 3F pursuant to EN This product is specially designed for installation in floor plates. The backflow stop can be retrofitted with a sealing flange to protect the device from pressurised water. The ACO black water automatic backflow stop is designed for use with wastewater containing faeces. Type 3F backflow stops must be used whenever toilets are installed below the backflow level. Two flaps are open during normal operations. When water from the sewers backflows into the pipes, the operating stop is automatically closed by a pneumatic/electric control device. As soon as the wastewater rises up above the permissible height in the pipe, an under pressure sensor sends a signal back to the control unit. The control unit automatically operates the electric motor to close the operating stop. When water no longer backflows into the system, a sensor informs the control unit and the flap is automatically reopened. The drainage installations connected to the backflow stop must not be used during a backflow situation! The presence of backflow is signalled by an optical and acoustic alarm. An integrated battery maintains continuous operations for up to 24 hours during a power cut. The ACO Quatrix-K also contains a manually operated emergency seal. The seal can be used manually. The flap can be turned into two positions. Picture 1: Operating seal and emergency seal are open. Wastewater can be drained. Picture 2: Operating seal closes automatically during backflow. An optical and visual alarm is signaled. Picture 3: If needed, the emergency seal can be closed manually. Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Pneumatic sensor for problem-free operation Installation example ACO Quatrix-K black water automatic backflow stop, DN 100 Type 3F pursuant to EN for installation in floor plates. Figure shows the ACO black water automatic backflow stop with the optional sealing flange to protect against pressurised water.

15 Article description ACO Quatrix-K black water automatic backflow stop, DN 100/125/150 Type 3F pursuant to EN for installation in floor plates. With telescopic, height adjustable top section and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For water containing faeces (black water) and wastewater without faeces (grey water), flood safety classification IP 68. For installation in pipes, gradient 12 mm, with double backflow safety valve, with automatic operating seal, with manually actuated emergency seal, with cleaning and maintenance opening, with inspection pipe. Electric control box IP 56, with optical and acoustic backflow warning, emergency power supply with safety battery including all connection cables. Weight 10.0 kg Article No. DN Ø (mm) L (mm) H1 H2 H min H max Optional components and accessories see page 18/ H2 H min. H max H1 D D 30 L Ø x300

16 ACO Quatrix-K black water automatic backflow stop The ACO Quatrix-K black water automatic backflow stop corresponds to Type 3F pursuant to EN This product is designed for use with wastewater containing faeces. Type 3F backflow stops must be used whenever toilets are installed below the backflow level. Two flaps are open during normal operations. When water from the sewers backflows into the pipes, the operating stop is automatically closed by a pneumatic/electric control device. As soon as the wastewater rises up above the permissible height in the pipe, an under pressure sensor sends a signal back to the control unit. The control unit automatically operates the electric motor to close the operating stop. When water no longer backflows into the system, a sensor informs the control unit and the flap is automatically reopened. The drainage installations connected to the backflow stop must not be used during a backflow situation! The presence of backflow is signalled by an optical and acoustic alarm. An integrated battery maintains continuous operations for up to 24 hours during a power cut. The ACO Quatrix-K also contains a manually operated emergency seal. The seal can be used manually. The flap can be turned into two positions. Position 1: Emergency seal closed no wastewater can be drained Position 2: Emergency seal opened wastewater can be drained. Operating seal closes automatically during backflow. 16 Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Pneumatic sensor for problem-free operation Installation example ACO Quatrix-K black water automatic backflow stop, DN 100 Type 3F pursuant to EN for installation in unenclosed drainpipes.

17 Article description ACO Quatrix-K black water automatic backflow stop, DN 100/125/150 Type 3F pursuant to EN for installation in unenclosed drainpipes. For water containing faeces (black water) and wastewater without faeces (grey water), flood safety classification IP 68. For installation in pipes, gradient 12 mm, with double backflow safety valve, with automatic operating seal, with manually actuated emergency seal, with cleaning and maintenance opening, with inspection pipe. Electric control box IP 56, with optical and acoustic backflow warning, emergency power supply with safety battery including all connection cables. Weight 10.0 kg Article No. DN Ø (mm) L (mm) H (mm) Optional components and accessories see page 18/ H D D L

18 Product DN order no. ACO single backflow stop Triplex-K-0, DN 100/ /150 Type 0 pursuant to DIN EN for installation in an unenclosed rainwater pipe Installation in pipes, with an automatically closing backflow flap, cleaning and maintenance opening. Weight 3.5 kg ACO single backflow stop Triplex-K-0, DN 100/ /150Type 0, pursuant to DIN EN for installation in floor plates, for rainwater With telescopically adjustable top section, and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For installation in pipes, with automatically closing backflow flap, cleaning and maintenance opening. Weight 6.5 kg ACO single backflow stop Triplex-K-1, DN 100/ /150 Type 1, pursuant to DIN EN 13564, for installation in unenclosed pipes for rainwater For installation in pipes, with an automatically closing backflow flap, with integrated emergency seal, secure manual closing with audible locking signal, cleaning and maintenance opening. Weight 3.5 kg 18 ACO single backflow stop Triplex-K-1, DN 100/ /150 Type 1, pursuant to DIN EN for installation in floor plates for rainwater With telescopically adjustable top section, and cover plate K3. Retrofittable with adjustable flange for sealing against pressurised water. For installation in pipes, with automatically closing backflow flap, with integrated emergency seal, safe manual locking thanks to audible locking signal, with cleaning and maintenance opening. Weight 6.5 kg ACO cleaning pipe Triplex-K, DN 100/125/ for installation in unenclosed pipes Retrofittable with backflow stop Type 0, 1, 2 or 3F Weight 6.5 kg ACO cleaning pipe Triplex-K, DN 100/125/ for installation in floor plates Retrofittable with backflow stop Type 0, 1, 2 or 3F Weight 6.5 kg

19 Optional components and accessories Product order no. Product order no. Conversion kit for Quatrix-K black water automatic backflow stop Type 3F. For converting cleaning pipes or backflow stops for wastewater free of faeces. DN 100/DN 125/DN 150 ACO locking cover l including rubber seal for ACO Triplex-K-0 single backflow stop Type 0 ACO Triplex-K cleaning pipe DN 100/DN 125/DN 150 ACO conversion kit for Triplex-Kdouble backflow stop Type 2. For conversion of cleaning pipes and backflow stops Types 0 or 1. DN 100/DN 125/DN 150 ACO extension with lip seal for ACO backflow stops and ACO cleaning pipes for installation in floor pipes DN 100/DN 125/DN 150 Installation height 100 mm ACO operating sealing flap with push-in component for ACO Quatrix-K black water automatic backflow safety valve Type 3F. DN 100/DN 125/DN 150 ACO sealing flange for ACO backflow stops and ACO cleaning pipes for installation in floor plates DN 100/DN 125/DN 150 ACO emergency sealing flap with push-in component for ACO Quatrix-K black water automatic backflow stop Type 3F. DN 100/DN 125/DN 150 ACO top section For ACO backflow stops and ACO cleaning pipes for installation in floor plates. DN 100/DN 125/DN 150 ACO control box Protection Type IP56 for ACO Quatrix-K black-water automatic backflow stop Type 3F. DN 100/DN 125/DN 150 ACO reversing cover, surface-water tight, For ACO backflow stops and ACO cleaning pipes for installation in floor plates. DN 100/DN 125/DN ACO drive with 5 metres of cable for ACO Quatrix-K black water automatic backflow safety valve Type 3F. DN 100/DN 125/DN 150 ACO test pipe for ACO Triplex-K-2 and ACO Quatrix-K ACO backflow sealing flap with push-in component for ACO Triplex-K-2 double backflow stop Type 2, ACO Triplex-K-1 single backflow stop Type 1, ACO Triplex-K-0 single backflow stop Type 0. DN 100/DN 125/DN 150 ACO locking cover including rubber seal for ACO Triplex-K-2 double backflow stop Type 2, ACO Triplex-K-1 single backflow stop Type 1. DN 100/DN 125/DN 150

20 ACO Triplex DN 50 backflow stop Small, compact, high performance perfect for retrospective installation to protect washing machines, wash basins and showers from backflow. The simple Type 0 backflow stop is used to protect unenclosed DN 50 wastewater pipes from backflow. Ideal for retroactive installation thanks to its compact dimensions. The backflow flap can open 100 % to allow outflowing water to pass unhindered without any restriction of the pipe cross-section. Blockages with this small backflow stop are therefore impossible. Product benefits Minimal product dimensions perfect for retroactive installation Toolless maintenance and cleaning Removable backflow flap for optimal pipe cleaning in both directions The ACO Triplex DN 50 backflow stop complies with DIN EN and features toolless cleaning and maintenance no pipe blockages because flap opens 100 %. 20

21 Article description ACO simple backflow stop,triplex-k-0 DN 50 Type 0 pursuant to DIN EN For installation in unenclosed pipes for wastewater free of faeces, with a self-closing backflow flap, with a cleaning and maintenance opening. Article No DN 50 EN Typ 0 PP DN ACO Triplex DN 50 with a completely practical cleaning opening for flushing and cleaning the pipe. Can be opened without tools. Just screw off the cleaning cap to remove the backflow flap without any tools for optimum cleaning of the pipe.

22 ACO Sinkamat-K mini lifting plant, underground The ACO Sinkamat-K underground mini lifting plant is an innovative solution for draining parts of buildings located beneath the backflow level. It is suitable for installation in floor plates. The lifting plant can also be installed in water-impermeable concrete by using the optional ACO sealing flange. This product is used for draining wastewater free of faeces. Drainage installations lying below the public sewers can only be drained into the public sewers by using an automatic wastewater lifting plant. The ACO Sinkamat-K underground mini lifting plant also provides optimal protection against backflow because the pressure pipe has to be led above the backflow level. The mini lifting plant consists of a collecting tank with three DN 100 inlet sockets, a height adjustable top section, and a pump with a float switch and integrated backflow flap. The collecting tank is made of high quality polyethylene with high chemical resistance, and high impact and collision resistance. A range of top sections are available. The wastewater from showers, washing machines etc. being drained from cellars flows into the inlet of the collecting tank. The float switch switches the pump on and off as required. The powerful pump has a quick connection for easy installation and dismantling without the use of tools. It has a capacity of up to 8 m 3 per hour and can suck out water to a depth of 10 mm. Maximum pump height 6.5 m. Installation example 22 ACO Sinkamat-K underground mini lifting plant for wastewater free of faeces, for installation in floor plates.

23 Article description ACO Sinkamat-K mini lifting plant for rooms lying below the backflow level, for wastewater free of faeces. High quality polyethylene tank for buried installation with DN 100 inlet sockets. With height adjustable top section, external dimensions 198 x 198 mm, height adjustable mm. Grey water submersible pump, with 220 volt AC motor, 50 HZ, 0.37 kw, 2850 rpm. 5 m connection cable, winding protection and float switch for low switch-on height, with integrated backflow flap and pressure pipe connection AG R 1 1/2". The pump has a quick connection for installation and dismantling without tools. Suitable for grain sizes up to 10 mm, maximum operating temperature 40 C. Hmax: 6.5 m Qmax: 8 m 3 /h Article No o ) Sinkamat-K (Article No ) Sinkamat-K (Article No ) 30 ventilation DN H max. 675 PVC-U pressure pipe with integrated check valve WU-concrete sealing ring (optional) PVC-U Ø430 Inlet DN PVC-U pressure pipe with integrated check valve WU-concrete sealing ring (optional) H min. 604 PVC-U Ø ventilation DN Ø75 inlet DN 100 Ø Ø replacement pump 50/1 Z m. 10 m cable/z. Sinkamat cable gland 335 inlet DN H max. 675 replacement pump 50/1 Z m. 10 m cable/z. Sinkamat cable gland 335 Ø Ø75 inlet DN inlet DN 100 inlet DN

24 ACO Sinkamat-K above-floor mini lifting plant The ACO Sinkamat-K above-floor mini lifting plant is an innovative solution for draining rooms lying below the backflow level. It is particularly suitable for drainage installations in cellars such as showers, washing machines or sinks for which no fitted drainage was originally planned. This product is used for draining wastewater free of faeces. Drainage installations lying below the public sewers can only be drained into the public sewers by using an automatic wastewater lifting plant. The ACO Sinkamat-K above-floor mini lifting plant also provides optimal protection against backflow because the pressure pipe has to be led above the backflow level. The mini lifting plant consists of a collecting tank onto which several inlets can be connected in situ, and a pump with a float switch and integrated backflow flap. The collecting tank is made of high quality polyethylene with high chemical resistance, and high impact and collision resistance. Thanks to its new modern shape, with the compact dimensions (l x w x h) 416 mm x 329 mm x 330 mm, the above-floor lifting unit can be easily installed beneath the usual sinks. The repositioned inspection opening enables the cover of the lifting plant to be easily removed forwards. This means that it is no longer necessary to dismantle the odour trap beneath the sink. The wastewater from showers, washing machines etc. being drained from cellars flows into the inlet of the collecting tank. The float switch switches the pump on and off as required. The powerful pump has a quick connection for easy installation and dismantling without the use of tools. It has a capacity of up to 8 m 3 per hour and can suck out water to a depth of 10 mm. Maximum pump height 6.5 m. Installation example 24 ACO Sinkamat-K above-floor mini lifting plant for wastewater free of faeces for free standing installation in frost-free rooms.

25 Article description ACO Sinkamat-K mini lifting plant For draining rooms below the backflow level, for wastewater free of faeces. High quality polyethylene tank for above-floor installation, modern shape with compact dimensions. Rearranged front-facing inspection opening, with tank venting and active charcoal filter. Several inlets of various sizes up to DN 50 can be connected to the tank in situ. Grey water submersible pump, with 220 volt AC motor, 50 HZ, 0.37 kw, 2850 rpm. 5 m connection cable, winding protection and float switch for low switch-on height, with integrated backflow flap and pressure pipe connection AG R 1 1/2". The pump has a quick connection for installation and dismantling without tools. Suitable for grain sizes up to 10 mm, maximum operating temperature 40 C. Hmax: 6.5 m Qmax: 8 m 3 /h Article No pump 50/1-Z without grip for Sinkamat ÜF made of plastic PVC-U connection pressure pipe with integrated check valve 416

26 ACO Muli-Star MDS1/MWS1 wastewater lifting plant Cellar rooms lying below the backflow level, and with no slope towards the sewers, must be drained in all cases with the help of a lifting plant. ACO has specially developed the ACO Muli-Star MDS1/MWS1 wastewater lifting plant for applications in detached houses and basement apartments: compact dimensions and five possible connections at different points make it ideal for all applications, especially when the installation situation is otherwise problematic. On the pressure-side, the compact lifting plant has a 57 mm impeller passage to ensure blockage-free operation of the system. The extra integrated ball backflow preventer ensures that backflowing sewage never flows back into the lifting plant. The low weight of 31 kg, and the readyto-install condition on delivery, guarantees rapid installation of the lifting plant. Installation example 26 ACO Muli-Star lifting plant for black water as a free standing installation in a frost free room.

27 Article description Polyethylene collecting tank with inspection shaft for simple maintenance, Ø 133 mm, with fastening kit for bolting down to prevent floating. With 3 horizontal inlet sockets DN 100, and 1 vertical inlet socket DN 50/DN 100, vent pipe connection DN 50 to connect to plastic vent pipe, with float switch, adjustable to match inlet height. Pressure pipe connection with integrated special fastening DN 100 for elastic connection to pressure pipes Ø mm. With connecting flange for stop valve DN 80 PN 10. Pump motor, 3-phase motor (MDS1): 400 V, 50 Hz, AC motor (MWS1): 230 V, 50 Hz, protection type IP 68, with unblockable free-flow impeller. Control box and alarm. Protection type IP 54, with 1.5 m cable and CEE plug (for MDS1) or with safety plug (MWS1), with isolated centralised alarm and operating display, including 5 m control cable between the lifting plant and the control box. Connection for manual membrane pump R 1½. Article Article No. MDS MWS Vent DN (T100) Power cable (1,5 m long) with CEE-plugr (MDS) or. Safety-plug (MWS) COntrol box (ready for plug) Ø Ø ,3 Special fastening for elastic connection to the pressure pipe DN 100 (Optional: sealing ring DN 80) Integrated Special backflow valve with purging device InletDN 50 InletDN 100 Ø (Z2) Ø (Z1) 40 Ø 52 Ø Collecting tank Float anchor fastening Screwed inspection cover DN 125 Cover / Feed-through float switch Connection Ø 48 for manual membrane pump Drain plug R 1 Free-flow impeller

28 ACO Muli-Max-F mono / duo pump shaft The ACO Muli-Max-F pump shaft made of PE-HD has particularly compact dimensions. The telescopic height-adjustable top section enables installation to a total depth of 3 metres. The pump shaft is available in three load classes: With cover Class A 15 supports weight of pedestrians With cover Class B 125 supports weight of cars With cover Class D 400 supports weight of trucks Thanks to its innovative design, the new ACO pump shaft cannot be pushed upwards by groundwater even if the water table rises to the top of the manhole cover. The collection tank is shaped to prevent the collection of sediment. The inside is designed to accommodate a whole range of different pump types depending on the specifications and applications. The pressure pipe and the tension chain are made of high quality stainless steel. The pneumatic water level switch guarantees high levels of operational safety. Two types of control box are available (with and without display), which guarantee optimal function and monitoring. The ACO Muli-Max-F multipurpose pump shaft is suitable for single and multifamily homes, for commercial properties, in industry, and for pressure drainage. Mono or Duo ideal pump stations for every application 28

29 ACO Muli-Max-F pump shaft Load Class A 15 Article description Areas of application: single and multifamily homes, commercial properties, industrial buildings, pressure drainage. Mono pump station (Duo pump station) for ground installation, made of polyethylene. Shaft body made of polyethylene, internal diameter: 900 mm. With automatic overwater coupling, for holding ACO submersible motor pumps. With pressure pipe outlet pipe made of stainless steel and 1 (2) ball valves R ½ ", stainless steel pressure pipe connection DN 40 or R 2", external pressure pipe connector to DN 50. Length from top shaft to centre pressure pipe: 1050 mm, layout nine o clock. 1 x DN 150 inlet pipe, length from base shaft to centre inlet 775 mm, layout three o clock (supplied kit containing seals). 2 x DN 100 connection sockets for empty cable conduit/venting layout six o clock and twelve o clock, length base shaft to centre connection socket 1439 mm, with coupling socket R ½ " for rinsing connection (optional accessory). 1 shaft cover (just laid on top), load class: A 15, internal diameter: 600 mm pursuant to DIN EN 124, without vent. With open impoundment bell. With ON-OFF pump alarm function. Pneumatic control cable, length: 10 m. ACO submersible motor pump(s), protection type IP 68. Pressure pipe connection, R 2" or 1½ ", ball retaining valve, stainless steel pipe and guide element to connect to overwater coupling, stainless steel chain, length: 1.5 m ACO system, General Building Supervisory Authority Authorisation: Z Article Article No. Mono Duo Ø816 operating key with chain purging connection pressure pipe DN 40, connection coupling Storz C 52 (optional) * Ø785 manhole cover Class A DIN EN 124 elastic conduct belt (optional) * displayed: top view type iduo * not included in the scope of delivery stepless height adjustable attachment (optional) * ca. 200 ball valve manhole cover class A DIN EN 124 connection DN 100 for empty cable conduit or ventilation ball retaining valve overwater coupling device for submerging pump 140 inlet DN H = 1900 H max = 3000 Installation example ACO Muli-Max-F mono polyethylene pump shaft with pre-assembled black water submersible pump 1050 traverse 775 Ø1200 connection DN 100 for empty cable conduit or ventilation pressure pipe connection DN 50 inlet DN 150

30 ACO Muli-Max-F pump shaft Load Class B 125 Article description Areas of application: single and multifamily homes, commercial properties, industrial buildings, pressure drainage. Mono pump station (Duo pump station) for ground installation, made of polyethylene. Shaft body made of polyethylene, internal diameter: 900 mm. With automatic overwater coupling, for holding ACO submersible motor pumps. With pressure pipe outlet pipe made of stainless steel and 1 (2) ball valves R ½ ", stainless steel pressure pipe connection DN 40 or R 2", external pressure pipe connector to DN 50. Length from top shaft to centre pressure pipe: 1050 mm, layout nine o clock. 1 x DN 150 inlet pipe, length from base shaft to centre inlet 775 mm, layout three o clock (supplied kit containing seals). 2 x DN 100 connection sockets for empty cable conduit/venting layout six o clock and twelve o clock, length base shaft to centre connection socket 1439 mm, with coupling socket R ½ " for rinsing connection (optional accessory). 1 shaft cover (just laid on top), load class: B 125, internal diameter: 600 mm pursuant to DIN EN 124, without vent, including 2 operating keys. With open impoundment bell. With ON-OFF pump alarm function. Pneumatic control cable, length: 10 m. ACO submersible motor pump(s), protection type IP 68. Pressure pipe connection, R 2" or 1½ ", ball retaining valve, stainless steel pipe and guide element to connect to overwater coupling, stainless steel chain, length: 1.5 m ACO system, General Building Supervisory Authority Authorisation: Z Article Article No. Mono cover laid on loose Mono cover with odour-tight threaded coupling Duo cover laid on loose Duo cover with odour-tight threaded coupling Ø816 Ø750 manhole Cover Class B DIN EN operating key with chain purging connection pressure pipe DN 40, connection coupling Storz C 52 (optional) * stepless height adjustable attachment (optional) * ca. 200 ball valve elastic conduct belt (optional) * manhole class B DIN EN 124 connection DN 100 for empty cable conduit or ventilation ball retaining valve overwater coupling device for submerging pump 140 inlet DN H = 1950 H max = 3000 displayed: top view type -duo * not included in the scope of delivery Installation example ACO Muli-Max-F duo polyethylene pump shaft with two preassembled black water submersible pumps 1050 traverse 775 Ø1200 pressure pipe connection DN 50 connection DN 100 for empty cable conduit or ventilation inlet DN 150

31 ACO Muli-Max-F pump shaft Load Class D 400 Article description Areas of application: single and multifamily homes, commercial properties, industrial buildings, pressure drainage. Mono pump station (Duo pump station) for ground installation, made of polyethylene. Shaft body made of polyethylene, internal diameter: 900 mm. With automatic overwater coupling, for holding ACO submersible motor pumps. With pressure pipe outlet pipe made of stainless steel and 1 (2) ball valves R ½ ", stainless steel pressure pipe connection DN 40 or R 2", external pressure pipe connector to DN 50. Length from top shaft to centre pressure pipe: 1050 mm,layout nine o clock. 1 x DN 150 inlet pipe, length from base shaft to centre inlet 775 mm, layout three o clock (supplied kit containing seals). 2 x DN 100 connection sockets for empty cable conduit/venting layout six o clock and twelve o clock, length base shaft to centre connection socket 1439 mm, with coupling socket R ½ " for rinsing connection (optional accessory). 1 shaft cover (just laid on top), load class: D 400, internal diameter: 600 mm pursuant to DIN EN 124, without vent, including 2 operating keys. With reinforced concrete load distribution plate: 1550/625 x 200 mm. With coupling, height: 1400 mm, height-adjustable, including seal. With open impoundment bell. With ON-OFF pump alarm function. Pneumatic control cable, length: 10 m. ACO submersible motor pump(s), protection type IP 68. Pressure pipe connection, R 2" or 1½ ", ball retaining valve, stainless steel pipe and guide element to connect to overwater coupling, stainless steel chain, length: 1.5 m ACO system, General Building Supervisory Authority Authorisation: Z Article Article No. Mono cover laid on loose Mono cover with odour-tight threaded coupling Duo cover laid on loose Duo cover with odour-tight threaded coupling Ø1550 Ø785 manhole cover class D DIN EN 124 displayed: top view type -duo operating key with chain purging connection pressure pipe DN 40, connection coupling Storz C 52 (optional) * ca. 200 ball valve traverse load-distributing panel elastic conduct belt stepless height adjustable attachment 1400 long connection DN 100 for empty cable conduit or ventilation ball retaining valve overwater coupling device for submerging pump inlet DN 150 H max = 2250 to 3000 (continuous height adjustable ) * not included in the scope of delivery Installation example ACO Muli-Max-F mono polyethylene pump shaft with one pre-assembled black water submersible pump Ø1200 connection DN 100 for empty cable conduit or ventilation pressure pipe connection DN 50 inlet DN 150

32 ACO Building Drainage product range Drainage Flat roof, balcony and terrace drains Floor drains and channels Bathroom systems Pipe systems Backflow stops Manhole covers Reinigungsverschlüsse Separating Grease separators Starch separators Light oil separators Process engineering Pumps Wastewater lifting plant Finished pump station ACO Passavant GmbH Im Gewerbepark 11c Stadtlengsfeld Tel Fax Geb 60 02/2010 The ACO Group. A strong family you can build on.

ACO ShowerDrain S-line Setting new standards for bathroom drainage

ACO ShowerDrain S-line Setting new standards for bathroom drainage ACO ShowerDrain S-line Setting new standards for bathroom drainage ACO. The future of drainage. The ACO system chain provides the drainage solutions for tomorrow s environmental conditions. Increasingly

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Protect Your Home From Flooding. A guide for Lethbridge Residents

Protect Your Home From Flooding. A guide for Lethbridge Residents Protect Your Home From Flooding A guide for Lethbridge Residents Every year, millions of litres of water flow into the City of Lethbridge s stormwater and wastewater collection systems from residential

More information

lifting stations motralec

lifting stations motralec 3.0 lifting stations motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological

More information

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm

More information

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Shower and Floor Gullies Channel Drain and Tile Drain SECTION Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

Preventing water damage in the basement

Preventing water damage in the basement Preventing water damage in the basement Thousands of home insurance claims are filed every year. Some losses are major, others aren t, but they re always an inconvenience and usually avoidable! As prevention

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

BASEMENT FLOODING. Prevention Guide for. Homeowners

BASEMENT FLOODING. Prevention Guide for. Homeowners BASEMENT FLOODING Prevention Guide for Homeowners 1 Did You Know? Floods are the most common hazards in Canada. Water damage is a common cause of loss for homeowner insurance. A heavy rainfall can result

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

swimming pool accessories

swimming pool accessories 76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.

More information

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants

More information

EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy. Tel. +39 0438.4697 - Fax +39 0438.460766. www.europlast.

EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy. Tel. +39 0438.4697 - Fax +39 0438.460766. www.europlast. EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy Tel. +39 0438.4697 - Fax +39 0438.460766 www.europlast.it e-mail: europlast@europlast.it 09/05 drainage system EXPORT COMPANY PROFILE

More information

Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation

Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation Ground Surface Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation Ground Surface Soil Ground Water Level Basement Wall Groundwater drains to

More information

foundation designed to keep water out of the basement.

foundation designed to keep water out of the basement. Preventing Sewer Backups To safeguard your home against flooding from sewer backups, you should understand your home's basic plumbing and the preventative techniques discussed in this brochure. Basement

More information

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH Proposed Construction of Basement Flood Risk Assessment 35 Edwardes Square London W8 6HH 1 Introduction This FRA has been carried out in accordance with the National Planning Policy Statement (NPPF), the

More information

BUILDING DRAINAGE. Planning and design in building drainage

BUILDING DRAINAGE. Planning and design in building drainage BUILDING DRAINAGE Planning and design in building drainage Planning and design in building drainage 4 Publisher: ACO Haustechnik ACO Passavant GmbH Im Gewerbepark 11 c 36457 Stadtlengsfeld No liability

More information

Plugging Home Drains to Prevent Sewage Backup

Plugging Home Drains to Prevent Sewage Backup AE-1476 Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or heavy rain, taking a few steps to prepare for water levels that could result

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Manual piston sampler...m 11

Manual piston sampler...m 11 SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the

More information

DUBLIN CITY COUNCIL FLOOD FORUM

DUBLIN CITY COUNCIL FLOOD FORUM DUBLIN CITY COUNCIL FLOOD FORUM PROPERTY FLOOD PROTECTION GUIDE DCC Customer Services (Drainage) DCC Flood Forum Tel: 222 0700 Tel: 222 3294 DCC Afterhours Tel: 679 6186 0 Rev 1 Aug 2013 DUBLIN CITY COUNCIL

More information

DRAIN CLEANING MACHINES

DRAIN CLEANING MACHINES CLEANER, PIPE CLEANING, For blockages in bathroom, toilet & laundry Drain Cleaner H 75 With Bulb Head:DH75B ø20~75mm Manual Plastic wire drum for easy maintenance after use. High quality wire for smooth

More information

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY a guide to PREVENTING SEWER BACKUPS AND FLOODING Sewer backups and flooding can damage District homes and businesses. Sewer blockages are most commonly found

More information

Drains and shower channels. Wastewater Drainage

Drains and shower channels. Wastewater Drainage Drains and shower channels Wastewater Drainage Drains for industrial and public buildings Bathrooms Wellness Ecoguss... 75 78 Practicus... 79 81 Bathroom drains For use in the private and commercial sector

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE 31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT

More information

Downspout to storm sewer. Leaky laterals

Downspout to storm sewer. Leaky laterals Flooded street Surface water through MH top Blocked street catch basin Cracked MH or sewer Property line Downspout to storm sewer BREATHERS Leaky laterals Weeping Tile to sanitary or storm sewer BASEMENT

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

VAG Non-Return Valves

VAG Non-Return Valves VAG Non-Return Valves VAG SKR Slanted Seat Tilting Disk Check Valve Body Shaft Disk Bearing bush Seat Technical details Nominal pressure PN 10 / PN 16 Nominal diameter DN 200...1200 Fields of application:

More information

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812 TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment

More information

1300 MAXTRAK SPECIFICATION

1300 MAXTRAK SPECIFICATION CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps grundfos se & sl ranges Submersible and dry-installed wastewater pumps 0.9-30 kw 2, 4, 6 pole 50Hz No compromise Highest total efficiency wastewater pumping ULTIMATE WASTEWATER PUMPING TECHNOLOGY The renewed

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5 PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

Puddle Flange. FRANK Puddle Flange

Puddle Flange. FRANK Puddle Flange Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES

CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES Introduction: In most cases when installing the Isola Platon cavity drain system the actual level of water ingress or potential level of water

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information

Top 10+ Mistakes of DWV plumbing design

Top 10+ Mistakes of DWV plumbing design Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of

More information

The Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES

The Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES The Axial Flow Valve SERIES Class 300/600 sales@elster-instromet.co.uk www.elster-instromet.com THE AXIAL FLOW VALVE - SERIES 300/600 A UNIQUE REGULATOR What is the Axial Flow Valve? The Axial Flow Valve

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer thameswater.co.uk/developerservices thameswater.co.uk/developerservices 1 Questions and answers Did you know Thames Water is legally responsible for more than 100,000

More information

Type of Sewer Systems. Solomon Seyoum

Type of Sewer Systems. Solomon Seyoum Type of Sewer Systems Solomon Seyoum 0 Learning objectives Upon completion of this lecture, the participants will be able to differentiate between types of sewer systems and discuss different aspects of

More information

Syphonic Roof Drainage

Syphonic Roof Drainage Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Plumbing for retail food businesses

Plumbing for retail food businesses Plumbing for retail food businesses Every day, thousands of food outlets in Sydney produce waste, such as cooking oil, grease and food solids. If that waste is discharged directly into our sewers, it can

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. SEPTIC TANK SYSTEMS There are three common types of septic tank systems in Tasmania Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. Dual purpose (or all-waste)

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

ACO Building Services

ACO Building Services ACO Building Services Floor drains Drainage technology competence ACO WAL-SELECTA cast iron floor drains ACO WAL-SELECTA cast iron floor drains Applications Floor drains safely drain off brown water from

More information

2013 Jetters. Ph: 800.771.1881 Fax: 877.526.3246. sales@sharkpw.com www.sharkpw.com. Effective January 1, 2013

2013 Jetters. Ph: 800.771.1881 Fax: 877.526.3246. sales@sharkpw.com www.sharkpw.com. Effective January 1, 2013 2013 Jetters BROCHURE Effective January 1, 2013 Ph: 800.771.1881 Fax: 877.526.3246 sales@sharkpw.com www.sharkpw.com 2013 shark Jetters Brochure PH: 800.771.1881 FAX: 877-526-3246 JETTERS drain cleaners

More information

Water Management all about networks

Water Management all about networks Water Management all about networks TABLE OF CONTENTS 1. Message from the mayor. Sanitary and storm sewer networks 3. Environmental and economic repercussions 4. Flood-prevention measures 5. Protective

More information

PREVENTING WET OR FLO ODED BASEMENTS

PREVENTING WET OR FLO ODED BASEMENTS PREVENTING WET OR FLO ODED BASEMENTS TABLE OF CONTENTS Prevention Tips...Page 1 Why is there Water in my Basement?...Page 2 City of Saskatoon Sewer Systems...Page 3 Why Does Saskatoon Have Two Separate

More information

1/3 HP Submersible Sump Pump with Vertical Float Switch

1/3 HP Submersible Sump Pump with Vertical Float Switch 1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity

More information

Drainage and Grease Management for the Commercial Kitchen

Drainage and Grease Management for the Commercial Kitchen Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

TELESCOPE Motorized Lighting Suspension

TELESCOPE Motorized Lighting Suspension TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend

More information

Uniclass L7315 + L2123 EPIC J3413. CI/SfB (52.5) Heavy duty channel drainage system ACO S Range

Uniclass L7315 + L2123 EPIC J3413. CI/SfB (52.5) Heavy duty channel drainage system ACO S Range Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) Heavy duty channel drainage system ACO S Range ACO S Range CHANNEL DRAINS Load Class BS EN 1433:2002 Optimum solution The ACO S Range is an interconnecting

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown

More information

minimum deductible may be increased significantly.

minimum deductible may be increased significantly. ABOUT YOUR HOUSE CE 50 Basement flooding is unfortunately a common occurrence in many parts of Canada. But the good news is that many types of basement flooding may be avoided. This publication explains

More information

Remote Head REMO ONE. Code 5750. Manual

Remote Head REMO ONE. Code 5750. Manual Remote Head REMO ONE Code 5750 Manual by sachtler. All rights reserved Version: 1.2/09/05 Issue date: September 2005 Order no.: srh20t010a We want you to receive Sachtler products that are always state

More information

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN 12566-3. Packaged Sewage Solutions with a Future (4-300 PT)

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN 12566-3. Packaged Sewage Solutions with a Future (4-300 PT) FLUIDO Fully Biological Sewage Treatment Plant according to EN 12566-3 Packaged Sewage Solutions with a Future (4-300 PT) We clear it for you REWATEC Top Quality from Germany A sewage treatment plant is

More information

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:

More information

The Town of Lakeshore Basement Flooding Information to Residents

The Town of Lakeshore Basement Flooding Information to Residents The Town of Lakeshore Basement Flooding Information to Residents The following information is intended for residents that have homes connected to Municipal storm and sanitary sewers. However, rural residents

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions

Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS GB OPERATING INSTRUCTIONS Automatic Wedge Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION The is an automatic wedge welding machine for

More information

PLUMBING CARE AND REPAIR

PLUMBING CARE AND REPAIR PLUMBING CARE AND REPAIR No special skills are required for any of the repairs described in this section. Plumbing repairs are seldom dangerous unless leaking water is soaking areas where there are electrical

More information