ANALYSIS OF SWITCHING TIME FOR PILOT OPERATED DIRECTIONAL CONTROL VALVE ANALIZA CZASU PRZESTEROWANIA ROZDZIELACZA STEROWANEGO POŚREDNIO

Similar documents
PROPORTIONAL FLOW CONTROLLER MODEL IN MATLAB-SIMULINK MODEL PROPORCJONALNEGO REGULATORA PRZEPŁYWU W MATLAB-SIMULINK

A R C H I V E S O F M E T A L L U R G Y A N D M A T E R I A L S Volume Issue 3

STUDIES OF TRUCK SEMITRAILER STABILITY DURING LOADING AND UNLOADING BADANIA STATECZNOŚCI NACZEPY SAMOCHODU CIĘŻAROWEGO PODCZAS ZAŁADUNKU I ROZŁADUNKU

AUTOMATED GENERATION OF 3D MODELS OF HYDRAULIC COMPONENTS ZAUTOMATYZOWANE GENEROWANIE MODELI 3D ELEMENTÓW HYDRAULICZNYCH

Example. Fluid Power. Circuits

Unit 24: Applications of Pneumatics and Hydraulics

MULTI-POLE MODELING AND INTELLIGENT SIMULATION OF A HYDRAULIC DRIVE WITH THREE-DIRECTIONAL FLOW REGULATING VALVE

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Slide Basic system Models

Unit 24: Applications of Pneumatics and Hydraulics

The Secret of Hydraulic Schematics. BTPHydraulics

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Unit 24: Applications of Pneumatics and Hydraulics

COUNTERBALANCE VALVES

Flow divider (flow distributor), type TQ

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

SIMPLIFIED VALVE CIRCUIT GUIDE

Moving Magnet Actuator MI FFA series

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Experiment 3 Pipe Friction

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

MODEL OF THE PNEUMATIC DOUBLE ACTING CYLINDER COMPILED BY RHD RESISTANCES

6. VVT-i (Variable Valve Timing-intelligent) System

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Series PVP Variable Volume Piston Pumps

Pressure drop in pipes...

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

CORRECTION OF DYNAMIC WHEEL FORCES MEASURED ON ROAD SIMULATORS

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

MODELING OF CAVITATION FLOW ON NACA 0015 HYDROFOIL

Manufacturing Equipment Modeling

Forces. Definition Friction Falling Objects Projectiles Newton s Laws of Motion Momentum Universal Forces Fluid Pressure Hydraulics Buoyancy

TRACKING ERRORS DECREASING IN CNC SYSTEM OF MACHINE TOOLS

P = n M 9550 [kw] Variable Intake Manifold in VR Engines. Self-study programme 212. Principles and Description of Operation. Service.

du u U 0 U dy y b 0 b

HYDRAULIC ARM MODELING VIA MATLAB SIMHYDRAULICS

Adaptation of General Purpose CFD Code for Fusion MHD Applications*

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

REDESIGN OF THE INTAKE CAMS OF A FORMULA STUDENT RACING CAR

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

Battery Thermal Management System Design Modeling

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Pressure Relief and Regulating Valves

DSRQ - DSRSQ - DSRSQ-THERM

FLUID MECHANICS IM0235 DIFFERENTIAL EQUATIONS - CB _1

Unit 24: Applications of Pneumatics and Hydraulics

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Hydraulic Troubleshooting PRESENTED BY

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

ROTARY GEAR FLOW DIVIDERS

Displacement (x) Velocity (v) Acceleration (a) x = f(t) differentiate v = dx Acceleration Velocity (v) Displacement x

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

SIMPLIFIED VALVE CIRCUIT GUIDE

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Modeling Mechanical Systems

Minor losses include head losses through/past hydrants, couplers, valves,

Water hammering in fire fighting installation

Agricultural Engineering 2014:1(149):65-72 H o m e p age:

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Contents. LWN edition:

MAXIMIZING THE OUTPUT OF YOUR BRAKES Getting Your Pedal Geometry Right

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

POWER EFFICIENCY MANAGEMENT OF PHOTOVOLTAIC ENERGY SOURCE BASED ON MPPT ALGORITHM

Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli , Tamil Nadu, India

Engineering Problem Solving as Model Building

INTERACTION OF LIQUID MOTION ON MOBILE TANK STRUCTURE

Unsteady Pressure Measurements

OPTIMIZATION OF DIAMETER RATIO FOR ALPHA-TYPE STIRLING ENGINES

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

Series TMM Axial Piston Motor. Technical Information

PART 2 FORKLIFT HYDRAULIC SYSTEM

Basic Principles in Microfluidics

Proportional and Servo Valve Technology

Monitoring of the single-point diamond dresser wear

Variable Displacement Pump AA10VSO

A Descriptive Summary of Vickers Inline Pumps and their Applications

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

DESCRIPTION OF MOTION OF A MOBILE ROBOT BY MAGGIE S EQUATIONS

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Design of heat exchangers

Experiment # 3: Pipe Flow

Engine Heat Transfer. Engine Heat Transfer

OPTIMISE TANK DESIGN USING CFD. Lisa Brown. Parsons Brinckerhoff

Why and How we Use Capacity Control

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Transcription:

TECHNICAL TRANSACTIONS MECHANICS CZASOPISMO TECHNICZNE MECHANIKA 1-M/013 JANUSZ RAJDA*, EDWARD LISOWSKI** ANALYSIS OF SWITCHING TIME FOR PILOT OPERATED DIRECTIONAL CONTROL VALVE ANALIZA CZASU PRZESTEROWANIA ROZDZIELACZA STEROWANEGO POŚREDNIO Abstract The paper presents an analysis of switching time for pilot operated directional control valve [1 3] in a typical hydraulic system, in which the actuator is a hydraulic cylinder. A mathematical model has been built which contains equations of motion for the valve and actuator components, the balance of fluid flow, flow through the gap, and the principle of conservation of momentum and the flow curves of pressure relief valves [6, 8]. The system of equations is solved by fourth- -order Runge-Kutta method. A survey to find minimal switching time has been conducted [4]. Positive overlap value, the coefficient of its movement resistance and control pressure value have significant impact on the switching time in the tested valve. Keywords: modeling of hydraulic systems, spool type directional control valve Streszczenie W artykule przedstawiono analizę czasu przesterowania suwakowego rozdzielacza pośredniego działania [1 3] w typowym układzie hydraulicznym, w którym elementem wykonawczym jest siłownik hydrauliczny. Zbudowano model matematyczny zawierający równania ruchu elementów zaworu i siłownika, bilansu przepływu cieczy, przepływu przez szczelinę i zasady zachowania pędu oraz charakterystyki zaworów przelewowych [6, 8]. Układ równań rozwiązano metodą zmiennokrokową Runge-Kutty 4 rzędu. Przeprowadzono badania polegające na poszukiwaniu najkrótszego czasu przesterowania [4]. Istotny wpływ na czas przesterowania w badanym rozdzielaczu ma wartość dodatniego przekrycia suwaka, współczynnik oporów jego ruchu oraz wartość ciśnienia sterownia. Słowa kluczowe: modelowanie układów hydraulicznych, rozdzielacz hydrauliczny suwakowy * MSc. Eng. Janusz Rajda, Ponar Wadowice S.A. ** Prof. Eng. Edward Lisowski, Institute of Applied Informatics, Faculty of Mechanical Engineering, Cracow University of Technology.

34 Designations m s, m t computational mass of directional control valve spool (or cylinder rod and piston) respectively, plus the mass of retainer, spring and volume mass of attached liquid V i the volume of the i-th line of the hydraulic system B i equivalent volumetric elastic modulus for i-th line of the hydraulic system Q i volumetric flow rate at the input for i-th line of the hydraulic system Q p pump volumetric efficiency p i pressure at i-th line of the hydraulic system p z1 cracking pressure for pressure relief valve at the system input dp z1 excess of cracking pressure for relief valve at the system input p z cracking pressure for pressure relief valve at the cylinder output dp z excess of cracking pressure for pressure relief valve at the cylinder output a s, a t kinematic coefficient of friction for the valve spool (or cylinder rod and piston) c centering spring stiffness coefficient for directional control valve F ss0 centering spring preload force for directional control valve F ss centering spring force for directional control valve F ts, F tt kinematic friction force of directional control valve (or cylinder rod and piston) x 1 coordinate of the spool position (from the neutral position) F hs control pressure force acting on the surface of the valve spool A s active area of the valve spool affected by pressure p 1 F ht resultant pressure force acting on the surface of the piston/piston rod F ds resultant hydrodynamic force acting on the spool of directional control valve, x coordinate of position of the cylinder piston/piston rod (from the maximum extended position) v speed of movement of the piston/piston rod S 1 sectional area of the piston rod S k active cross-sectional area on the side of the cylinder piston rod S s width of the flow gap at the valve spool S k minimum cross section of stream at the valve channel x p1 overlap value for the valve spool m 1 liquid outflow coefficient r fluid density a i fluid inlet/outlet angle for i-th control edge fluid flow speed at the i-th control edge v Qi 1. Introduction Control of working movements at the machinery or equipment with hydraulic drive is usually carried out by means of directional control valves, usually spool type [1, ]. Start or change of direction of the working movement is caused by the spool shift. Therefore, switching of the directional control valve is forcing the system, so switching time is important in the valve operation. By changing the switching time, we can change time constants for

343 the whole hydraulic system [11]. In industrial applications, there are many solutions to allow forcing of hydraulic directional control valves, for example in the form of slots cut in the spool, proportional spool position control by a given course, etc. [5, 7, 10, 1]. All of these solutions increase the time constant of the directional control valve, which usually has a positive effect on the elimination of hydraulic hammer and pressure excess at start of the system. However, in some applications of directional control valves, such as safety devices, in order to obtain a rapid response of the machinery or equipment, the switching time should be as short as possible [9]. In this paper, the task undertaken is to determine parameters associated with the spool which affect the speed of the opening of flow path at the valve. The study has been conducted using the hydraulic pilot operated directional control valve type WEHE [13].. Object of the study General view of the directional control valve is shown in Fig. 1. It is built of the main body 1, the spool, the retainers 3 and the centering spools 4, the covers 5 forming the pressure chambers 6 and 7 and the pilot valve 8. Switching the valve is caused by the fluid under pressure provided into the chamber 6 (or 7) and the simultaneous relief of the opposite chamber 7 (or 6). As a result of the force of the fluid pressure, the spool overcoming the force of the spring, motion resistance and hydrodynamic force, moves toward the extreme position forming different configuration of connections. Fig. 1. Schematic structure of directional control valve WEHE Rys. 1. Schemat budowy rozdzielacza WEHE 3. Mathematical model Operation of directional control valve WEHE has been examined in the hydraulic system, the schematic diagram of which is shown in Figure. Hydraulic cylinder 4 is assumed to be working element. The system is supplied by a fixed displacement pump of

344 capacity Q p. The pump is connected with a hydraulic directional control valve by means of the conduit with volume V 1 and pressure p 1. This line is characterized by constant volumetric elastic modulus B 1. At the output of the directional control valve and the inlet of the hydraulic line having a volume V and equivalent volumetric elastic modulus B, flow is Q 1. Pressure in this line is p. The liquid of flow rate Q flows into the hydraulic cylinder and flows out of flow rate Q 3 to the hydraulic line V 3 with an equivalent volumetric elastic module B 3. In this line, there is pressure p 3. The cylinder load is simulated by means of pressure relief valve 6. On energizing the solenoid 3, pilot valve 1 gives pressure into control chamber of the spool initiating the process of moving the spool and allowing the flow of fluid in the system. It is assumed that the system is in thermal equilibrium, and the mass of the liquid is concentrated in specific points of the system, that is, the valve spool, the individual sections of the line and the rod (and the piston) of the cylinder. The pressure in the drain line is omitted. Under these assumptions, the mathematical model will constitute the differential equations for the valve spool movement and cylinder piston rod movement, equations of flow continuity and the principle of conservation of momentum as well as equations of flow through the slot and performance curves of pressure relief valves. Fig.. Hydraulic diagram with the marked system parameters Rys.. Schemat hydrauliczny wraz z oznaczeniami parametrów układu Equations of the forces acting on the spool of directional control valve: m d x 1 s Fts Fss Fds F hs dt + + + = (1)

345 Equation of the cylinder piston rod motion: m d x t Ftt dt = Fht () Flow balance equation for volume V 1 : Flow balance equation for volume V : Q V1 dp1 Qp Q1 Qz1 = (3) B dt ( V + S1 x ) dp Q = B dt 1 Flow balance equation for volume V 3 : Q ( V3 S x ) dp Q = B dt 3 4 Volumetric flow rate Q and Q 3 can be determined from the relation: 3 1 3 Q = S v, Q = S v (6) 3 1 Volumetric flow rate through the slot Q 1 can be determined: Q = µ S ( x ) 1 1 s 1 ( p1 p) ρ Function S s (x 1 ) is determined on the base of measurements on 3D model and approximated by the function: Ss( x1) = a1 ( x1 xp1) + a ( x1 xp1) for Ss < Sk Ss = Sk for Ss Sk (8) Ss = 0 for x 1 < x p1 Volumetric flow rate Q 4 can be determined from the valve performance curve and describe by the relation: Q4 = k4 ( p3 + dpz) for p3 > pz Q4 = 0 for p3 pz (9) Volumetric flow rate Q z1 can be determined from the valve performance curve and describe by the relation: Qz1 = kz1 ( p1+ dpz1) for p1 > pz1 Qz1 = 0 for p1 pz1 (10) Spring force F ss can be determined from the relation: Fss = Fss0 + c x1 (11) Viscous friction force of the spool F ts and piston rod F tt can be determined from the relation: (4) (5) (7)

346 F = α x, F = α x (1) tt t ts s 1 Forces from control pressure acting on the spool F hs and cylinder piston rod F ht can be determined from the relation: F = A p A p, F = A p (13) ht 1 3 hs a 1 The resultant value of hydrodynamic forces acting on the valve spool can be calculated from the relation (Figure 3): F = ρ [ Q ( v cosα v cos α ) Q ( v cosα v cos α )] (14) hd1 1 Q1 1 Q 4 Q4 4 Q5 5 Fig. 3. Inlet and outlet angle of fluid stream on control edges Rys. 3. Kąt wlotu i wylotu strugi cieczy na krawędziach sterujących 4. Test results In order to determine the time for full opening of the directional control valve, system of equations (1) to (14) is resolved, using the data from technical information of the directional control valve WEHE. It was assumed that the control pressure (X) is obtained from the main supply line of the system (P). Moreover, the figures are taken for the cylinder: diameter D = 100 mm, d t = 56 mm and stroke 1000 mm. Forcing at the input is pump with constant flow Q p = 480 dm 3 /min. Example response of the spool to step forcing for standard value of positive spool overlap (x p1 = 5 mm) and reduced overlap (x p1 = 0.5 mm) are shown in Fig. 4. Fig. 5 and 6 show respectively pressure course in the volume V 1 and piston rod velocities v. As follows from the courses, the lower value of overlap parameter (x p1 = 0.5 mm), the valve spool moves a little more slowly to the end position. This is due to a lower pressure during the start-up of the system (Fig. 5). Reducing the spool overlap value, however, results in earlier opening of the flow ways and the piston rod faster begins to move, as is shown in Fig. 6. Reduction of the directional control valve overlap allows to reduce the response time of the valve in the initial phase of its operation. In the final stage, speed of the spool movement decreases due to the pressure drop at pressure line, from where control pressure is taken. Excessive reduction of the spool overlap value will result in increased internal leakage. The study for various combination of parameters have shown that in addition to reducing the spool overlap value, reduction of spool movement resistance and increase of control pressure have a significant impact on minimizing the switching time.

347 Fig. 4. Spool valve movement as a response to step forcing Rys. 4. Przemieszczenie suwaka rozdzielacza jako odpowiedź na wymuszenie skokowe Fig. 5. Pressure course at the system inlet Rys. 5. Przebieg ciśnienia na wejściu do układu Fig. 6. Velocity course for the cylinder piston rod Rys. 6. Przebieg prędkości tłoczyska siłownika

348 References [1] Amirante R., Moscatelli P.G., Catalano L.A., Evaluation of the flow forces on a direct (single stage) proportional by means of a computational fluid dynamic analysis, Energy Conversion and Management 48, 007, 94-953. [] Amirante R., Del Vescovo G., Lippolis A., Evaluation of the flow forces on an open centre directional control valve by means of a computational fluid dynamic analysis, Energy Conversion and Management 47, 006, 1748-1760. [3] Lisowski E., Domagała M., Determination of static characteristic of direct acting relief valve, Proceedings of the 1st international conference on computational methods in fluid power technology, Melbourne 003, 11-0. [4] Lisowski E., Domagała M., Optimization hydraulic components using fluid-solid interaction simulation, Proceedings of 4th FPNI-PhD Symposium, Florida-Sarassota 006, 151-159. [5] Lisowski E., Filo G., Zastosowanie logiki rozmytej do sterowania proporcjonalnym zaworem przelewowym, Przegląd Mechaniczny, nr 1/00. [6] Momeni H., Lisowski E., CFD analysis of pilot operated relief valve, Proceedings of 5th FP -NI-PhD Symposium, Kraków 008, 493-500. [7] Stryczek S., Napędy hydrostatyczne, WNT, Warszawa 1999. [8] Lisowski E., Rajda J., Modelowanie CFD przepływu przez zespół zaworów, Konferencja Napędy i sterowania hydrauliczne i pneumatyczne, Wrocław 01. [9] Renn J.C., Kao T.C., Application of CFD to design a power-saving hydraulic directional two-land-four-way-valve, Proceedings of the 1st international conference on computational methods in fluid power technology, Melbourne 003, 6-8. [10] Standard ISO 4401-08-07-0-94. [11] Manring N.D., Modeling Spool-Valve Flow Forces, University of Missouri at Columbia, 004, ASME International Mechanical Engineering Congress and Exposition, Anaheim, USA, 004. [1] Osiecki A., Napęd i sterowanie hydrauliczne maszyn. Teoria obliczenia układu, Wydawnictwo Politechniki Gdańskiej, Gdańsk 1981. [13] Catalogue: Ponar Wadowice. Directional spool valve, WK 460 110, 04.001.