Detecting glass particles in glass jars of baby food

Similar documents
Coating Thickness and Composition Analysis by Micro-EDXRF

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Scanners and How to Use Them

Application Report: Running µshape TM on a VF-20 Interferometer

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Technical Considerations Detecting Transparent Materials in Particle Analysis. Michael Horgan

Ultrasonic Wave Propagation Review

INTRODUCTION. A. Purpose

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

Analytical Test Method Validation Report Template

Sound absorption and acoustic surface impedance

Encoders for Linear Motors in the Electronics Industry

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

SPECIAL APPLICATIONS

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Radiation Strip Thickness Measurement Systems

Introduction to Fourier Transform Infrared Spectrometry

Measuring of optical output and attenuation

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

TOF FUNDAMENTALS TUTORIAL

The accurate calibration of all detectors is crucial for the subsequent data

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Application Note: Absorbance

Atomic and Nuclear Physics Laboratory (Physics 4780)

MACHINE VISION MNEMONICS, INC. 102 Gaither Drive, Suite 4 Mount Laurel, NJ USA

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT

Cargo Container X-ray Inspection Systems

After a wave passes through a medium, how does the position of that medium compare to its original position?

1 Laboratory #5: Grating Spectrometer

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Product Range Overview

EDXRF of Used Automotive Catalytic Converters

The Array Scanner as Microdensitometer Surrogate: A Deal with the Devil or... a Great Deal?

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

The future of X ray inspection systems in the food industry 1. Why do manufacturers need X ray inspection systems?

Theremino System Theremino Spectrometer Technology

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Silicon, the test mass substrate of tomorrow? Jerome Degallaix The Next Detectors for Gravitational Wave Astronomy Beijing

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

Name Class Date. spectrum. White is not a color, but is a combination of all colors. Black is not a color; it is the absence of all light.

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Uses of Derivative Spectroscopy

2 Spectrophotometry and the Analysis of Riboflavin

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

ADVANCES IN AUTOMATIC OPTICAL INSPECTION: GRAY SCALE CORRELATION vs. VECTORAL IMAGING

Copyright by Mark Brandt, Ph.D. 12

Quality Control and Maintenance Programs

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Single Photon Counting Module COUNT -Series

2 Absorbing Solar Energy

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Automated Contact Resistance Tester CR-2601

Pneumatic control loops save water and energy with fixed-bed filters

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement

Plastic Film Texture Measurement With 3D Profilometry

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Application Example: Quality Control of Injection-Molded Parts

DLO1191 Linear smoke detector

APPLICATION NOTES: Dimming InGaN LED

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

Function Guide for the Fourier Transformation Package SPIRE-UOL-DOC

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

LASER ENGRAVING REFLECTIVE METALS TO CREATE SCANNER READABLE BARCODES Paper P516

Module 13 : Measurements on Fiber Optic Systems

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

SCAN R tm. Snapshot Characterization and Analysis Software. Version 1.0 Product description and features

Chapter 17: Light and Image Formation

FIBER OPTIC COMMUNICATIONS. Optical Fibers

Fluorescent Array Imaging Reader

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

13C NMR Spectroscopy

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Teaching Time: One 25-minute period. Lesson Summary Students use iron filings to observe the 2 and 3- D field lines around a magnet.

Introduction to CCDs and CCD Data Calibration

Technical Article. Gesture Sensors Revolutionize User Interface Control. By Dan Jacobs

What food processors should know: metal detection vs. X-ray inspection

Silicon Drift Detector Product Brochure Update 2013

VECTORAL IMAGING THE NEW DIRECTION IN AUTOMATED OPTICAL INSPECTION

Information about the T9 beam line and experimental facilities

Application Note AN DirectFET Technology Inspection Application Note

THE DØ Luminosity Monitor (LM) consists of two array of

Technical Bulletin on the Evaluation of the Kinetics Tuned Absorber/Diffuser Panel by Peter D'Antonio RPG Diffusor Systems, Inc Upper Marlboro, MD

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system

Transcription:

Detecting glass particles in glass jars of baby food Ben Lopez, Adam Hirst and Tamzin Lafford IBEX Innovations Ltd., Discovery 2, NETPark, William Armstrong Way, Sedgefield, TS21 3FH, U. K. Abstract IBEX technology has been successfully demonstrated to detect glass beads down to 1 mm in diameter in glass jars of puréed baby food in a standard X-ray imaging system using a conventional X-ray detector. Such contaminants present little or no contrast in X-ray absorption, a technique widely used in food safety inspection, making them very difficult to detect by these means. By applying IBEX MAP technology to recover energy-dependent information from a standard X-ray detector with the X-ray source working at a single peak kv, images are generated based on contrast between the materials (rather than a combination of their thickness and density). Contaminant particles can then be highlighted by their material difference from normal product. There are no inherent barriers to applying this technology at speeds compatible with food production lines. Introduction Food safety is obviously very important, and infants are at particular risk if their food is contaminated. Glass jars running through a production line occasionally get chipped, potentially leaving small fragments of glass in the contents of the jar. These are a health hazard, particularly to a baby, and such fragments are not necessarily easy to spot visually on spooning out the contents, since glass is optically transparent, while the food is generally opaque. Identifying and rejecting contaminated or damaged jars of baby food before they leave the factory is a critical step in the quality assurance process. X-ray inspection systems are used routinely in the food industry to monitor production quality. However, low-density contaminants such as glass and plastic in food are difficult to detect, since there is little or no X-ray absorption contrast between the contaminant and the food product. IBEX technology brings the contaminants to light by recovering energy-dependent information from conventional X-ray detectors in images collected at a single source kv setting. This leads to differentiation between materials directly, independent of their thicknesses or absorption contrast, since their X-ray attenuation characteristics are a function of energy. The capability of IBEX technology to detect glass beads down to 1 mm in diameter in glass jars of puréed baby food in a singleenergy X-ray imaging system has been demonstrated. There are no intrinsic obstacles to applying this technology on a production line. 004-MM-004 Rev. 1.00 Page 1 of 5 2016 IBEX Innovations Ltd.

IBEX technology The absorption of X-rays by a material depends on the material type, its thickness, and the energy of the X-rays (Eq. 1): I(E) = I 0 (E)exp ( μ(e)t) Eq. 1 where I(E) is the intensity incident on the detector, as a function of energy; I 0(E) is the incident intensity, as function of energy; µ(e) is the linear attenuation coefficient of the material as a function of energy, and t is the material thickness. The X-ray imaging detectors most widely used are based on silicon with a scintillator in front. These are rapid, relatively inexpensive, reliable and available in large areas. They measure an integrated signal in each pixel spectral information is lost. There is therefore no direct way to determine both material and thickness from the signals obtained. While spectroscopic detectors are available, they are generally slower than silicon detectors, more expensive and are not usually available in large areas. IBEX overcomes the limitations by placing a patented Multi-Absorption Plate (MAP) in front of a standard X-ray imaging detector, which could be a flat-panel or a line scanner or other configuration. The MAP is a 3D periodic structure which modulates the X-ray spectrum in a predictable manner over a few pixels, repeating the pattern across the area of the detector. Materials information is extracted from the modulated image, enabling generation of an image based on differences between materials, rather than on X-ray absorption contrast. Once the material is identified, thickness information is then also available. The results can be presented in a variety of ways, depending on the requirements of the application. A high resolution, conventional absorption contrast image is returned as part of the process. Figure 1 schematically shows a conventional X-ray imaging system: the source delivers a spectrum of energies which are attenuated by the sample according to the material thicknesses and densities in the beam path. The resulting absorption contrast image is collected using a flat-panel detector or a line scanner. In this example, there are three bone fragments in the mass of chopped chicken, but they cannot be identified via the range of grey levels in the absorption contrast image. Introduction of the IBEX MAP (Figure 2) allows a materials image to be constructed. Having identified the contaminants, the information may be presented in various ways, such as the materials contrast and contaminant overlay images shown. X-ray source Sample absorbs X-rays X-ray absorption contrast image Standard digital X-ray detector Figure 1: Conventional X-ray absorption contrast imaging. The X-ray source delivers a spectrum of energies. The X-rays are attenuated by the sample according to the materials and their thicknesses in the path of the beam, resulting in an absorption contrast image. 004-MM-004 Rev. 1.00 Page 2 of 5 2016 IBEX Innovations Ltd.

X-ray source Sample absorbs X-rays IBEX MAP modulates X-ray beam Standard digital X-ray detector Experiment Samples were measured using an in-house, fixed cabinet X-ray system fitted with a conventional, low-power, tungsten-target X-ray source running at 160 kv, 0.5 ma (80 W). Given this low power compared to typical inspection systems, the total integration time per image was 7.5 s in order to give high signal-to-noise within this test. (This time would be much reduced on a production tool). The detector was a Rayence 1417 WGA CMOS flat-panel detector equipped with an IBEX Multi-Absorption Plate (MAP). Jars were mounted by hand against an alignment jig. Figure 2: An IBEX MAP-enabled system. The MAP modulates the image in a predictable manner, allowing recovery of energy-dependent information leading to construction of a materials contrast image, as seen above. For assessing a repeatable product such as a jar of baby food, a statistical model is built of normal product, using known clean examples. The model is based on beliefs about the mathematical description of noncontaminated product and is automatically updated by incorporating information on clean samples and the normal, acceptable variations between them, as further samples are measured. Automated decision rules are employed to create an algorithm capable of detecting contaminant fragments, since their material signature differs from that of baby food. The model includes descriptions of the materials (the baby food and its container) as well as the shapes associated with the product. IBEX materials contrast image The MAP does not add overheads to image acquisition, and data processing can be done in real time, so there are no fundamental barriers to implementing this technology in a production environment. Contaminant identification overlay First, 20 glass jars of puréed baby food (all the same variety) were measured and the images analysed in order to build the mathematical model of normal product, including the acceptable variation within normal, and to train the analysis system in the materials signatures of the baby food and jar. Sample images were corrected for flat-field and dark-field prior to IBEX materials analysis. Five additional jars were deliberately contaminated with glass beads 1 mm, 2 mm and 3 mm in diameter placed in the bulk of the baby food. These were then measured along with a further 14 uncontaminated jars, in random order, in the test run. Figure 3: Left: one of the jars of puréed baby food used in the trial. Right: glass beads used for the contamination. 004-MM-004 Rev. 1.00 Page 3 of 5 2016 IBEX Innovations Ltd.

Results and Discussion Besides low/no contrast between the glass bead contaminants and the baby food in glass jars, a particular challenge in this case is that the shape of the sample varies slightly between samples. The shape of the meniscus of the contents is not constant; neither are the details of the shape of the glass jar and its local thickness. These variations must be recognised within the model of normal, whilst retaining sensitivity to deviations from normal caused by contaminants. Using IBEX materials contrast technology, the glass contaminants stand out well against the puréed baby food, despite some local variations in jar thickness. All five contaminated samples were correctly identified, with a clear, quantitative distinction between contaminated and uncontaminated jars. An example is shown in Figure 4 and Figure 5. Figure 4 shows the absorption contrast image (the IBEX image with the effect of the MAP stripped out). It is hard to see the glass bead contaminants in this image. Figure 5 shows the contaminants identified using IBEX materials technology, highlighted in orange overlaid on the absorption contrast image. Figure 5: IBEX materials technology detects the contaminants. In the image above, they are shown in orange. In this demonstration of capability, there were no false positives and no false negatives. Images of all 19 test jars, with contaminants highlighted, are shown in Figure 6. Figure 4: Absorption contrast image of a contaminated jar of baby food. The glass bead contaminants are barely visible. The pale rectangle in the bottom left of the image comes from the alignment jig used in this test where the samples were positioned manually. Figure 6: Absorption contrast images of all 19 jars in the test set. The glass contaminants were successfully detected in the five contaminated jars. These are framed in yellow, with the contaminants themselves highlighted in orange. Contaminant detection based on IBEX materials technology delivers a measure of 004-MM-004 Rev. 1.00 Page 4 of 5 2016 IBEX Innovations Ltd.

contaminant significance for each sample. The values for uncontaminated samples are scattered around some mean value, while values for contaminated jars are markedly different (Figure 7). This allows a threshold to be set to discriminate between contaminated and uncontaminated jars, as a pass/fail criterion in a production environment. Acknowledgments Thanks to Jordan Hall for technical support in data collection, and to Adam Ratcliffe for help with data analysis. References IBEX technology is protected by a number of patent applications worldwide. See www.ibexinnovations.co.uk for the latest information. Contaminated jars Threshold Non-contaminated jars Figure 7: Quantitative measures of contaminant significance enable thresholding in a production QA environment. This test showed clear differences in this measure between contaminated and non-contaminated samples. Conclusions In a demonstration of capability, IBEX materials contrast technology successfully identified five jars of baby food deliberately contaminated with glass beads from a test set of a total of 19 jars. The difference in the quantitative measure of contaminant significance between clean and contaminated jars opens the possibility of pass/fail thresholding in a production environment. There are no inherent barriers to this technology being applied at production-line speeds and it may be used with flat-panel or line detectors. 004-MM-004 Rev. 1.00 Page 5 of 5 2016 IBEX Innovations Ltd.