Surge protection devices

Similar documents
SURGE PROTECTIVE DEVICES

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

DEHNshield Application-optimised multipole combined lightning current and surge arrester

wietap wietap Overvoltage Protection Tensions running high

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

Surge Protection for Photovoltaic Systems

CATALOGUE SURGE PROTECTION LOW VOLTAGE

Products and solutions for lifting systems

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

Products and solutions for pumping, irrigation and piping

Class I surge protection with sparkover gaps

White paper. ABB solutions for switching and protection of low speed wind turbines

R.C.C.B. s two-pole LEXIC

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

38 Series - Relay interface modules A

Three-phase monitoring relay CM-PFE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

38 Series - Relay interface modules A

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

DC Combiner box and AC solutions. Leadership in circuit protection

Products and solutions for machine builders (OEM) 100% electricity

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

5SV Residual Current Protective Devices

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electronic overload relay EF65, EF96 and EF146

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Electronic overload relay EF19 and EF45

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Low Voltage Products. Switches Automatic Transfer Switches

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Safety technique. Emergency stop module BO 5988 safemaster

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Unified requirements for systems with voltages above 1 kv up to 15 kv

Redundancy Module QUINT-DIODE/40

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Rack mounted telephone- and leased line modem for industrial applications

SELECTION OF FINAL CIRCUIT PROTECTION

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ADM1TE 5/30A DIN rail single phase two wire energy meter

MasterINTERFACE 39 Series - Relay interface modules

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RM4TG20 three-phase network control relay RM4-T - range V

How To Build A Low Voltage Capacitor Lvcp

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

RELAYS Solar Energy Systems

Electrical safety and protection devices

Arc Terminator Active Arc-Resistant Switchgear

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

49 Series - Relay interface modules A. Features

How can a charging station for electric vehicles be set up simply and safely?

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Photovoltaic System Overcurrent Protection

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

3-phase, bidirectional energy meter

RY2 miniature industrial relays

Thermistor motor protection

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Type: DILM9 10(24VDC) Article No.:

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

MasterINTERFACE 39 Series - Relay interface modules

Bimetallic Overload Relay Specifications

48 SERIES Relay interface modules 10 A

Surge protection for emergency alarm systems

ABB solutions for photovoltaics Protection and other modular devices

ABB Inc. April 19, 2011 Slide 1

Catalog. Modular DIN rail components Installation contactors

Emergency lighting units EM powerled

Telephone- and leased line modem for industrial applications TD-36

The complete range of consumer switchboards and switchgear

Relés e Contatores de Estado Sólido SIRIUS

Breaking and protection devices

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Transcription:

Surge protection devices

Surge protection dev TY 1, 2 MODUAR COCEPT For quick assembly of different versions based on various requirements COMPACT SIZE Also compliant with electrical equipment standards EASY MOUTIG AD REMOVA With 35mm DI rail IP20 PROTECTIO DEGREE Finger safe PHOTOVOTAIC CERTIFIED VERSIOS U Recognized for USA and Canada and compliant with UTE C 61740-51 PROTECTIO AGAIST OVERVOTAGE Caused by direct or indirect lightning strikes TYS WITH PUG-I CARTRIDGES For fast servicing capability STATUS IDICATOR For single modules VERSIOS WITH OR WITHOUT COTACT For SPD remote status indication VERSIOS FOR PHOTOVOTAIC APPICATIOS Up to 1500VDC EXCEET PROTECTIO EVE Up 1.5kV Suitable for protection of all terminal equipment. TY 2 2

ices TY 1, 2,3 OVATO Electric surge arresters commonly defined as SPDs (Surge Protection Devices), are devices designed to protect electric systems and equipment against transient and impulse overvoltages such as those caused by lightning and by electric switching. Their function is to divert the discharge or impulse current generated by an overvoltage to earth, thereby protecting the equipment downstream. The range is available in monoblock versions or with removable cartridges in class I, II and III for alternating current (AC) applications and with removable cartridges in class II for photovoltaic applications (DC). Range SA1 SA2 SA0 SA2 D Version Monoblock With plug-in cartridge With plug-in cartridge With plug-in cartridge Classification E Type 1, 2 Type 2 Type 1, 2, 3 Type 2 for PV IEC Class I, II Class II Class I, II, III Class II for PV VDE Class B, C Class C Class B, C, D Class C for PV Continuous voltage Uc 320VAC/ 320VAC/ 320VAC/ 600...1500VDC 420VDC 420VDC 420VDC Impulse current Iimp 25kA -.5kA - 10/350µs Max discharge current Imax 8/20µs 100kA 40kA 60kA 40kA Rated discharge current In 8/20µs 25kA 20kA 25kA 20kA Combined surge Uoc/Isc 1.2/50, 8/20µs - - 10kV / 5kA - 3

Technical characteristics Surge protection devices SPDs are installed in parallel to the electric line to be protected. At the mains rated voltage, they are comparable to an open circuit and have a high impedance at their ends. In the presence of an overvoltage, this impedance falls to very low values, closing the circuit to earth. Once the overvoltage has ended, their impedance rises again rapidly to the initial value (very high), returning to open loop conditions. PZ protection zones Type 1, 2 (Class B, C) Type 2 (Class C) Type 1, 2, 3 (Class B, C, D) O A O B 1 2 3 Protection zones Standards define the PZs (ightning Protection Zones), which indicate the different zones at risk. These are distinguished as: PZ 0A: Area outside a building not protected by PS (e.g. lightning rods) where a direct lighting strike is possible. In this zone, there is total exposure to induced electromagnetic fields. PZ 0B: Area outside a building protected by PS; therefore, a direct lighting strike is not possible. In this zone, there is total exposure to induced electromagnetic fields. PZ 1: Area inside a building so protected against direct lightning strikes. In this zone, there is the possibility of very high overvoltages and of induced electromagnetic fields which may be attenuated depending on the degree of screening. This zone must be protected by an SPD type 1 at the boundary with zone PZ 0A or 0B. PZ 2: Area inside a building (e.g. in a room), in which there is the possibility of low overvoltages since they are limited by SPDs installed upstream. This zone must be protected by an SPD type 2 at the boundary with zone PZ 1. PZ 3: Area inside a building (e.g. the system connected to a socket in a room) characterised by very sensitive equipment, in which there is the possibility of very low overvoltages as they are limited by SPDs installed upstream. This zone must be protected by an SPD type 3 at the boundary with zone PZ 2. Installation category For the correct choice of the SPD, the dielectric strength of the equipment to protect needs to be considered. This level is established by IEC 60664-1 standard. A 230/400V system specifies: - Installation category I: 1.5 kv for equipment containing particularly sensitive electronic circuits (for example, electronic devices like PCs or TVs) - Installation category II: 2.5 kv for non electronic devices (for example, household appliances or electric tools) - Installation category III: 4 kv for devices being part of the fixed system (for example, distribution boards,, 2,3 100% I imp 10/350μs Installation category Impulse withstand voltage of equipment 100% l n IV 6kV 8/20μs III 4kV switching devices, isolators, ducting and their accessories) - Installation category IV: 6 kv for devices installed upstream of the distribution board (for example, delivery point with the distribution system). Definitions and ratings - Maximum continuous voltage Uc: Maximum value of AC or DC voltage that the SPD is capable of permanently withstanding without activating or getting damaged; this is its rated voltage. - Protection level voltage Up: Maximum value of the voltage between the terminals of the SPD in presence of an impulsive overvoltage. It is a fundamental parameter to correctly choose the SPD; account of it must be taken in relation to the impulse voltage of the equipment to be protected. - Impulse current Iimp: Peak value of the current that flows in the SPD with a 100% Uoc II 2.5kV I 1.5kV 1.2/50μs 50% 50% 50% 10% 10% 10% 10 350 t (μs) 8 20 t(μs) 1.2 50 t(μs) Impulse current Iimp Rated discharge current In o-load charge voltage Uoc 4

10/350µs waveform (activation must be guaranteed for 20 times without damage). It is used to classify SPDs in test class I. - Rated discharge current In: Peak value of the current that circulates in the SPD with an 8/20µs waveform (activation must be guaranteed for 20 times without damage). It is used to classify SPDs in test class II. - o-load discharge voltage Uoc: Peak value of the no-load discharge voltage delivered by the test generator with 1.2/50µs waveform simultaneously with a short-circuit current with 8/20µs waveform, applied at the terminals of the SPD. It is used to classify SPDs in test class III. - Maximum discharge current Imax: Peak value of the current that flows in the SPD with an 8/20µs waveform. An SPD is capable of withstanding it at least once. Suggestions for installation Fuse (g/gg fuses), which should be chosen according to the SPD manufacturer s instructions. F1 SA2 3 F2 F1 > 5A g/gg F2 =5A g/gg F1 5A g/gg F2 = not required. SPD coordination In order to obtain an effective protection against overvoltage, it is advisable to install several SPDs coordinated with one another in cascade connection. For instance, it is advisable to have a class I SPD in the main distribution board, a class II SPD in the sub-distribution board and a class III SPD near the end equipment to be protected. In this way, the energy originating from an overvoltage gradually decreases as it reaches the equipment to protect. SURGE PROTECTIO DEVICES FOR PHOTOVOTAIC APPICATIOS Class II SPDs can be used to protect the system in a domestic environment and in industrial buildings when equipped with lightning rod systems having a safety distance S. It is advisable to install class II SPDs as close as possible to the panels, consequently in the so-called string boards. If the inverter is far away from the string boards (indicatively more than10m away), another class II SPD needs to be installed next to the inverter on the DC side. Installation of a class II AC SDP suitable for the type of system is required downstream of the inverter on the AC side. S P D a a+b <_ 0.5m Housing b EBB Fuse S P D b <_ 0.5m Industrial buildings Main inverter switchboard b EBB EBB: Equipotential Bonding Bar. For correct installation, it is advisable to make connections between the line and the SPD input (phase or neutral terminals) as well as between the SPD output (earth terminal) and the equipotential bonding connection with a maximum 0.5m length of the leads. To reduce the distance, use of the so-called V connection is admissible. String switchboard Back-up protection Protection against short circuits of SPDs is provided by overcurrent devices 5

TY 1, 2 CASS B, C Monoblock The surge protection device type SA1 combines the performance of SPD type 1 and 2 into a single product. It protects against direct and indirect lightning strikes as well as induced overvoltage conditions. It can be installed in areas with a high risk of direct lightning strikes, inside main distribution boards or sub-distribution boards. Operational characteristics Maximum continuous voltage Uc: 320VAC/420VDC Impulse current Iimp (10/350µs): 25kA per pole; Rated discharge current In (8/20µs): 25kA per pole; Maximum discharge current Imax (8/20µs): 100kA per pole Standard-supplied contact for remote status indication Degree of protection: IP20. Reference standards Comply with standards: IEC 61643-1, E 61643-. SA1... Order Pole Contact DI Rated Voltage pro- Power Qty Wt code arrange- remote size voltage Un tection level Up installation per pkg ment available n [VAC] [kv] system n [kg] SA1 1P A320R 1P YES 2 230 <1.3 T-C, T-S, TT❶ 1 0.275 SA1 1 A320R 1P+ YES 3 230 <1.4 TT, T-S 1 0.3 SA1 2P A320R 2P YES 2 230 <1.4 T-S 1 0.395 SA1 3P A320R 3P YES 3 230/400 <1.4 T-C 1 0.595 SA1 3 A320R 3P+ YES 5 230/400 <1.4 TT, T-S 1 0.760 SA1 4P A320R 4P YES 4 230/400 <1.4 T-S 1 0.780 ❶ For - only. TY with signal contact SA1 1P A320R SA1 1 A320R SA1 2P A320R SA1 3P A320R SA1 3 A320R SA1 4P A320R Electrical properties SPD per E 61643- Type 1, 2 SPD per IEC 61643-1 Class I, II SPD per VDE 0675-6 Class B, C Rated voltage Un VAC 230 230 230 230 / 400 230 / 400 230 / 400 Maximum continuous voltage Uc VAC / VDC 320 / 420 Impulse current Iimp (10/350) (-/-) ka 25 25 / 50 25 per pole 25 per pole 25 / 100 25 per pole Max impulse current Imax (8/20)(-/-) ka 100 100 / 100 100 per pole 100 per pole 100 / 100 100 per pole Rated discharge current In (8/20) (-/-) ka 25 25 / 50 25 per pole 25 per pole 25 / 100 25 per pole Voltage protection level Up (-/-) kv <1.3 <1.4 / <1.5 <1.4 <1.4 <1.4 / <1.75 <1.4 Temporary overvoltage (TOV) Ut (- for 5s) VAC 335 Residual voltage Ures (-/-) at 3kA (8/20) kv 0.9 0.9 / 0.2 0.9 0.9 0.9 / 0.2 0.9 Follow current If (-) Arms o >100 o o >100 o Tripping time ta (-/-) ns <25 <25 / 100 <25 <25 <25 / 100 <25 Thermal isolation protection Yes Back-up protection fuse (supply >250A) A 250 g/gg Maximum short-circuit current (50Hz) ka 25 Status indicator - blown Colour Red Connections Degree of protection IP 20 Terminal tightening torque m 3 Maximum conductor section mm 2 25 (flexible) / 35 (rigid) Type of signalling contact Changeover (SPDT) Contact capacity A 250VAC / 0.5A; 5VAC / 3A; 250VDC / 0.1A; 5VDC / 0.2A Contact terminal tightening torque m 0.25 Maximum contact conductor section mm 2 1.5 Ambient conditions Operating temperature -40.+80 C Fixing On 35mm DI rail (IEC/E 60715) Housing material Thermoplastic, RA 7035, U 94 V-0 6

TY 2 CASS C With plug-in cartridge The surge protection device type SA2 is suitable for installation in sub-distribution boards and near to terminal equipment. It protects against indirect overvoltages. The protection cartridges are plug-in and can be easily replaced for quick servicing. Operational characteristics Maximum continuous voltage Uc: 320VAC/420VDC Rated discharge current In (8/20µs): 20kA per pole Maximum discharge current Imax: (8/20µs) 40kA per pole Version with or without contact for remote status indication Degree of protection: IP20. Reference standards Comply with standards: IEC 61643-1, E 61643-. SA2... Order Pole Contact DI Rated Voltage pro- Power Qty Wt code arrange- remote size voltage Un tection level Up installation per pkg ment available n [VAC] [kv] system n [kg] SA2 1P A320 1P 1 230 <1.5 T-C, T-S, TT❶ 1 0.0 SA2 1P A320R 1P YES 1 230 <1.5 T-C, T-S, TT❶ 1 0.5 SA2 1 A320 1P+ 2 230 <1.5 TT, T-S 1 0.240 SA2 1 A320R 1P+ YES 2 230 <1.5 TT, T-S 1 0.245 SA2 2P A320 2P 2 230 <1.5 T-S 1 0.260 SA2 2P A320R 2P YES 2 230 <1.5 T-S 1 0.265 SA2 3P A320 3P 3 230/400 <1.5 T-C 1 0.370 SA2 3P A320R 3P YES 3 230/400 <1.5 T-C 1 0.375 SA2 3 A320 3P+ 4 230/400 <1.5 TT, T-S 1 0.465 SA2 3 A320R 3P+ YES 4 230/400 <1.5 TT, T-S 1 0.470 SA2 4P A320 4P 4 230/400 <1.5 T-S 1 0.480 SA2 4P A320R 4P YES 4 230/400 <1.5 T-S 1 0.485 ❶ For - only. TY without signal contact SA2 1P A320 SA2 1 A320 SA2 2P A320 SA2 3P A320 SA2 3 A320 SA2 4P A320 with signal contact SA2 1P A320R SA2 1 A320R SA2 2P A320R SA2 3P A320R SA2 3 A320R SA2 4P A320R Electrical properties SPD per E 61643- Type 2 SPD per IEC 61643-1 Class II SPD per VDE 0675-6 Class C Rated voltage Un VAC 230 230 230 230 / 400 230 / 400 230 / 400 Maximum continuous voltage Uc VAC / VDC 320 / 420 Max impulse current Imax (8/20)(-/-) ka 40 40 / 40 40 per pole 40 per pole 40 / 40 40 per pole Rated discharge current In (8/20) (-/-) ka 20 20 / 20 20 per pole 20 per pole 20 / 20 20 per pole Voltage protection level Up (-/-) kv <1.5 <1.5 / <2 <1.5 <1.5 <1.5 / <2 <1.5 Temporary overvoltage (TOV) Ut (- for 5s) VAC 335 Residual voltage Ures (-/-) at 3kA (8/20) kv 0.95 0.95 / 0.1 0.95 0.95 0.95 / 0.1 0.95 Follow current If (-) Arms o >100 o o >100 o Tripping time ta (-/-) ns <25 <25 / 100 <25 <25 <25 / 100 <25 Thermal isolation protection Yes Back-up protection fuse (supply >5A) A 5 g/gg Maximum short-circuit current (50Hz) ka 25 Status indicator - blown Colour Red Connections Degree of protection IP 20 Terminal tightening torque m 3 Maximum conductor section mm 2 25 (flexible) / 35 (rigid) Contact capacity A 250VAC / 0.5A; 5VAC / 3A; 250VDC / 0.1A; 5VDC / 0.2A Type of signalling contact Changeover (SPDT) Contact terminal tightening torque m 0.25 Maximum contact conductor section mm 2 1.5 Ambient conditions Operating temperature -40.+80 C Fixing On 35mm DI rail (IEC/E 60715) Housing material Thermoplastic, RA 7035, U 94 V-0 7

TY 1, 2,3 CASS B,C,D With plug-in cartridge The surge protection device type SA0 with plug-in cartridge combines the performance of SPD type 1, 2 and 3 into a single product. It is ideal in all those systems of reduced extent, to protect the load side from the main circuit breaker downstream to terminal equipment. It protects against direct and indirect lightning strikes as well as induced overvoltage conditions. It can be installed inside main distribution boards and near by terminal equipment. The protection cartridges are plug-in and can be easily replaced for quick servicing. Operational characteristics Maximum continuous voltage Uc: 320VAC/420VDC Impulse current Iimp (10/350µs):.5kA per pole Rated discharge current In (8/20µs): 25kA per pole Maximum discharge current Imax (8/20µs): 60kA per pole Combined surge Uoc/Isc (1.2/50, 8/20µs): 10kV/5kA Standard-supplied contact for remote status indication Degree of protection: IP20. Reference standards Comply with standards: IEC 61643-1, E 61643-. SA0... Order Pole Contact DI Rated Voltage pro- Power Qty Wt code arrange- remote size voltage Un tection level Up installation per pkg ment available n [VAC] [kv] system n [kg] SA0 1P A320R 1P YES 1 230 <1.5 T-C, T-S, TT❶ 1 0.195 SA0 1 A320R 1P+ YES 2 230 <1.5 TT, T-S 1 0.365 SA0 2P A320R 2P YES 2 230 <1.5 T-S 1 0.370 SA0 3P A320R 3P YES 3 230/400 <1.5 T-C 1 0.540 SA0 3 A320R 3P+ YES 4 230/400 <1.5 TT, T-S 1 0.670 SA0 4P A320R 4P YES 4 230/400 <1.5 T-S 1 0.670 ❶ For - only. with signal TY contact SA0 1P A320R SA0 1 A320R SA0 2P A320R SA0 3P A320R SA0 3 A320R SA0 4P A320R Electrical properties SPD per E 61643- Type 1, 2, 3 SPD per IEC 61643-1 Class I, II, III SPD per VDE 0675-6 Class B, C, D Rated voltage Un VAC 230 230 230 230 / 400 230 / 400 230 / 400 Maximum continuous voltage Uc VAC / VDC 320 / 420 Impulse current Iimp (10/350) (-/-) ka.5.5 / 50.5 per pole.5 per pole.5 / 50.5 per pole Max impulse current Imax (8/20)(-/-) ka 60 60 / 50 60 per pole 60 per pole 60 / 50 60 per pole Rated discharge current In (8/20) (-/-) ka 25 25 / 30 25 per pole 25 per pole 25 / 30 25 per pole Combined surge Uoc/Isc (1.2/50, 8/20) kv/ka 10/5 Voltage protection level Up (-/-) kv <1.5 <1.5 / <1.7 <1.5 <1.5 <1.5 / <1.7 <1.5 Temporary overvoltage (TOV) Ut (- for 5s) VAC 335 Residual voltage Ures (-/-) at 3kA (8/20) kv 0.8 0.8 / 0.2 0.8 0.8 0.8 / 0.2 0.8 Follow current If (-) Arms o >100 o o >100 o Tripping time ta (-/-) ns <25 <25 / 100 <25 <25 <25 / 100 <25 Thermal isolation protection Yes Back-up protection fuse (supply>160a) A 160 g/gg Maximum short-circuit current (50Hz) ka 25 Status indicator - blown Colour Red Connections Degree of protection IP 20 Terminal tightening torque m 3 Maximum conductor section mm 2 25 (flexible) / 35 (rigid) Type of signalling contact Changeover (SPDT) Contact capacity A 250VAC / 0.5A; 5VAC / 3A; 250VDC / 0.1A; 5VDC / 0.2A Contact terminal tightening torque m 0.25 Maximum contact conductor section mm 2 1.5 Ambient conditions Operating temperature -40.+80 C Fixing On 35mm DI rail (IEC/E 60715) Housing material Thermoplastic, RA 7035, U 94 V-0 8

TY 2 DC CASS C PV For photovoltaic applications The surge protection device type SA2 D with plug-in cartridge for photovoltaic applications is suitable for installation on the DC side of a photvoltaic system and protects against induced overvoltage conditions. The protection cartridges are plug-in and can be easily replaced for quick servicing. Operational characteristics Maximum continuous voltage Ucpv: 600VDC, 1000VDC, 00VDC, 1500VDC Rated discharge current In (8/20µs): 20kA per pole Maximum discharge current Imax: (8/20µs) 40kA per pole Temporary overvoltage (TOV) Ut: 1.5Ucpv (SA2 DA... type only) Version with or without contact for remote status indication Degree of protection: IP20. Certifications and compliance Certifications obtained: curus (except for SA2 DA K50R and SA2 DB... types). Comply with standards: IEC 61643-1, E 61643-; UTE C 61740-51 for SA2 DA... types only. SA2 D... Order Pole Contact DI Rated Continuous Voltage pro- Qty Wt code arrange- remote size voltage Un voltage Ucpv tection level Up per pkg ment available n [VDC] [VDC] [kv] n [kg] SA2 DB 600 +, -, 2 600 600 <1.9 1 0.320 SA2 DB 600R +, -, YES 2 600 600 <1.9 1 0.325 SA2 DB K00 +, -, 3 1000 1000 <3.6 1 0.420 SA2 DB K00R +, -, YES 3 1000 1000 <3.6 1 0.425 Version compliant with UTE C 61740-51 Guide. SA2 DA 600R +, -, YES 2 600 600 <2.2 1 0.285 SA2 DA K00R +, -, YES 2 1000 1000 <2.8 1 0.305 SA2 DA K20R +, -, YES 3 00 00 <4.4 1 0.410 SA2 DA K50R +, -, YES 3 1500 1500 <4.8 1 0.500 without signal TY contact SA2 DB 600 SA2 DB K00 with signal contact SA2 DA 600R SA2 DA K00R SA2 DA K20R SA2 DA K50R SA2 DB 600R SA2 DB K00R Electrical properties Certifications curus SPD per E 61643- Type 2 SPD per IEC 61643-1 Class II SPD per VDE 0675-6 Class C Rated voltage Un VDC 600 1000 00 1500 600 1000 Maximum continuous voltage Ucpv VDC 600 1000 00 1500 600 1000 Max discharge current Imax (8/20) ka 40 per pole 30 per pole 40 per pole 40 per pole 40 per pole 40 per pole Rated impulse voltage In (8/20) ka 20 per pole 20 per pole 20 per pole 20 per pole 20 per pole 20 per pole Voltage protection level Up kv <2.2 <2.8 <4.4 <4.8 <1.9 <3.65 Residual voltage Ures at 3kA (8/20) kv 1 Follow current If Arms o Tripping time ta ns < 25 Thermal isolation protection Yes Back-up protection fuse (Isc >10A) A ot required 10gPV Maximum short-circuit current Iscwpv A 200 10 Status indicator - blown Colour Red Connections Degree of protection IP 20 Terminal tightening torque m 3 3 Maximum conductor section mm 2 25 (flexible) / 35 (rigid) Type of signalling contact Changeover (SPDT) Contact capacity A 250VAC / 0.5A; 5VAC / 3A; 250VDC / 0.1A; 5VDC / 0.2A Contact terminal tightening torque m 0.25 Maximum contact conductor section mm 2 1.5 Ambient conditions Operating temperature -40.+80 C Fixing On 35mm DI rail (IEC/E 60715) Housing material Thermoplastic, RA 7035, U 94 V-0 9

Dimensions [mm] 1,2,3 Type 1, 2 (Class B, C) SA1...A320R 36 54 Type 2 (Class C) SA2...A320 18 36 54 SA2...A320R 18 36 54 SA0...A320R 94 103 Type 1, 2, 3 (Class B, C, D) 103 101 18 36 54 Type 2 for photovoltaic applications (Class C PV) SA2 DB... SA2 DB...R 103 94 36 54 SA2 DA...R 36 54 103 10 36 54

Wiring diagrams Type 1, 2 (Class B, C) SA1 1P A320R SA1 1 A320R SA1 2P A320R SA1 3P A320R SA1 3 A320R SA1 4P A320R 1, 2 TY Type 2 (Class C) SA2 1 A320 SA2 2P A320 / SA2 3P A320 SA2 1P A320R SA2 2P A320R SA2 4P A320 TY SA2 4P A320R SA2 3 A320R SA2 3P A320R SA2 1 A320R / SA2 3 A320 2 SA2 1P A320 Type 1, 2, 3 (Class B, C, D) TY SA0 1 A320R / SA0 2P A320R SA0 4P A320R 1 SA0 3 A320R SA0 3P A320R 1,2,3 SA0 1P A320R Type 2 for photovoltaic applications (Class C PV) SA2 DB 600R + - + SA2 DB 600 SA2 DB K00R - - + SA2 DA 600R SA2 DA K00R SA2 DB K00 + SA2 DA K20R SA2 DA K50R - TY T.C. T.C. T.C. T.C. T.C. 2 DC

The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards. www.ovatoelectric.com OVATO EECTRIC S.P.A. Present in over 100 countries VIA DO E. MAZZA, - 24020 GORE (BERGAMO) ITAY Tel. +39 035 42821 Fax +39 035 4282200 E-mail: info@ovatoelectric.com Sales department: Tel. +39 035 4282354 - Fax +39 035 4282400 OVATO Electric offices in the world United Kingdom OVATO EECTRIC TD Tel. +44 8458 0023 www.ovato.co.uk Czech Republic OVATO EECTRIC S.R.O. Tel. +420 226 203203 www.ovatoelectric.cz Germany OVATO EECTRIC GmbH Tel. +49 43 7669370 www.ovatoelectric.de USA OVATO EECTRIC IC Tel. +1 757 5454700 www.ovatousa.com Spain OVATO EECTRIC S..U. Tel. +34 93 78016 www.ovatoelectric.es Canada OVATO EECTRIC CORP. Tel. +1 450 6819200 www.ovato.ca Poland OVATO EECTRIC SP. Z O.O. Tel. +48 71 79710 www.ovatoelectric.pl United Arab Emirates OVATO EECTRIC ME FZE Tel. +971 50 8833 247 www.ovatoelectric.ae PD79 GB 02