OBJY8.E Systems, Electrical Insulation Certified for Canada - Component

Similar documents
Material and Components Used for UL/C-UL/ULC Mark Follow-Up Services

Technical Information. UL-Recognized 600 Volt Class Electrical Insulation Systems Based On NOMEX

Overview. 2 Von Roll Insulation Training

Hook-Up and Lead Wire

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

For more information please contact your local UL field representative

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Certificate of Compliance

Batteries in HP notebooks


Release: 2. UEENEEJ194A Solve problems in low voltage refrigeration circuits

Power Resistor for Mounting onto a Heatsink Thick Film Technology

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

GC-3 Green Seal Environmental Criteria for Anti-Corrosive Paints

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

White Papers: Delayed Egress Hardware

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

RTV162. Electronic Grade Silicone Adhesive Sealant

Industrial Control Power Transformers

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ex.com. ID 4016 Rev A

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

New Cable Tie Type Classifications

1 Form A Solid State Relay

UL TEST REPORT AND PROCEDURE

ACTIVITE RACCORDEMENT 10 RUE AMPERE CHASSIEU CEDEX FRANCE TERMINAL BLOCKS

Meeting the Fire Code with Continuous Foam Plastic Insulation

FIRESTOPPING. Cable. Firestopping is the technology used to

Residential Air Conditioning. Program Standards

American National Standard For Electrical Rigid Steel Conduit (ERSC)

Solid State Lighting Definitions for Functional and Decorative Applications

Double Coated Urethane Foam Tapes

Screw Plug Immersion Heaters

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness

Industrial Semi Metal USB

Magnet Wire Hermincel 200 C

DNVGL-CP-0393 Edition December 2015

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PLP - TERMS AND CONDITIONS

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

WOYR2.E Switches, Appliance and Special Use - Component. Switches, Appliance and Special Use - Component

i410/i1010 AC/DC Current Clamp

Baldor Electric Position on DOE Small Motor Rule

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Evaluating Water-Damaged Electrical Equipment

Simulation Technology to Support the Design of Electric Distribution and Control Devices

Mecc Alte 400Hz In Depth

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

5SV Residual Current Protective Devices

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Certification of Plastic Materials

Building Cables and Wires

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Unified requirements for systems with voltages above 1 kv up to 15 kv

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Technical Data Sheet February 2014

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications

Optocoupler, Phototransistor Output, AC Input

Bulletin Approval of electrical equipment. Bulletin Approval of electrical equipment

A Practical Guide to Dielectric Testing

Photovoltaic MOSFET Driver with Integrated Fast Turn-Off, Solid-State Relay

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Basic Nameplate Information

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

SECTION 22 LIGHTNING PROTECTION SYSTEM

For the modifications listed below, the Qualification Approval tests in IEC and IEC 61646, shall be used as a guideline by the assessor:

SECTION METAL WALL PANELS

The Japan Society of Mechanical Engineers C 2010

UL Online Certifications Directory

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Making a world of difference. Turbocor centrifugal compressors for air-conditioning systems

BASIS RANGE TMB SERIES

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Circuit Breakers. NRC Series. NRC Series

Hitachi Cable, Ltd. Auto Parts Business Strategy

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

USB-to-Data Highway Plus Cable

Performance Rating of Room Fan- Coils

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

The oil condition sensor increases the function range of the thermal oil level sensor. The oil condition sensor measures the following variables:

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Electrical Maintenance Workshop

MATERIAL SAFETY DATA SHEET PRODUCT: CFW Uncoated, CFW Coated (UL-15), CFW Coated (A-12) REVISION DATE: December 9 th, 2008

Removable Insulation Blankets from A to Z

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Low Profile Unit Cooler

Transcription:

OBJY8.E209256 See General Information for TOYOZUMI DENGENKIKI CO LTD 4-16-1 KOISHIKAWA BUNKYO-KU, TOKYO 112-0002 JAPAN E209256 Class 155 (F) insulation system, designated 20. Marking: Company name, system designation and Recognized Component Mark for Canada. Last Updated on 2008-10-14

OBJY8.GuideInfo [Insulating Devices and Materials Certified for Canada - Component] (Plastic Materials and Electrical Insulation Systems Certified for Canada) Systems, Electrical Insulation Certified for Canada - Component See General Information for Plastic Materials and Electrical Insulation Systems Certified for Canada - Component The devices covered under this category are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. THE FINAL ACCEPTANCE OF THE COMPONENT IS DEPENDENT UPON ITS INSTALLATION AND USE IN COMPLETE EQUIPMENT SUBMITTED TO UNDERWRITERS LABORATORIES INC. USE This category covers combinations of insulating materials arranged to form an insulation system such as that used in magnetic devices, such as motors, transformers, solenoids, etc. Also included are coated core (integral ground) insulation constructions. Insulation systems rated greater than 105 C (A) have been tested to demonstrate their acceptability for use at a specified temperature class by either the thermal aging programs of Underwriters Laboratories Inc. or an equivalent consideration. For insulation systems rated at 105 C (A) or less, the insulation systems have been qualified by a modified version of the aforementioned thermal aging programs. Coated core constructions are additionally examined and tested to determine the insulating qualities of the coating and that the coating can be applied with uniform thickness and has the ability to adhere to the substrate. Unless otherwise specified in the individual Recognitions, the insulation system has been investigated for use at a rated voltage corresponding to the low-voltage distribution network where transient overvoltages are limited and partial discharge is not likely to contribute to the degradation of the insulation system. This application is consistent with systems extending from the consumer's service in low-voltage or extra-low voltage applications at not more than 750 V according to CAN/CSA-C22.1, "Canadian Electrical Code, Part I." CONDITIONS OF ACCEPTABILITY Unless specified otherwise in the individual Recognitions, consideration is to be given to the following Conditions of Acceptability when these components are employed in the end-use equipment: 1. End-product constructional details and test performance are not covered under this category; such investigations are found in the end-product standards under which the products are examined and tested. 2. Special chemical environments, such as refrigerants, oils, soaps, x-ray, ultraviolet light, etc., are not covered under this category. 3. The acceptability of construction features of the transformer, motor or coil assemblies produced with these insulation systems, such as spacings, insulation thicknesses (greater than those specified under "Construction Details" in the individual Reports for the insulation systems), thickness and voltage rating of lead insulation (if applicable), etc., shall be determined in the end-use application. Additional Conditions of Acceptability may be specified in the individual Recognitions. REQUIREMENTS These products have been investigated to comply with the requirements of CAN/CSA-C22.2 No. 0, "General Requirements - Canadian Electrical Code, Part II, Appendix B." UL MARKING Components Recognized under UL's Component Recognition Program are identified by markings consisting of the Recognized company's identification and catalog, model, or other product designation. In addition, components produced under the UL Component Recognition Program will also bear the Recognized Component Mark for Canada. The Listing or Classification Mark of Underwriters Laboratories Inc. is not authorized for use on, or in connection with, Recognized Components. Only those components that actually bear the "Marking" should be considered as being covered under the Component Recognition Program.

* * * * * * * * * * * * * * * * * * * * * * * * * UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information. Last Updated on 2004-07-15

OBEU8.GuideInfo Plastic Materials and Electrical Insulation Systems Certified for Canada - Component [Insulating Devices and Materials Certified for Canada - Component] Plastic Materials and Electrical Insulation Systems Certified for Canada - Component See General Information for Insulating Devices and Materials Certified for Canada - Component Last Updated on 1994-10-13

NYYV8.GuideInfo Insulating Devices and Materials Certified for Canada - Component Insulating Devices and Materials Certified for Canada - Component Last Updated on 1994-03-26