MAXI-CAST RESIN TRANSFORMERS

Similar documents
This section applies to the design and installation of transformers.

SECTION DRY-TYPE TRANSFORMERS

Presentation of the France Transfo factories

SECTION SUBSTATION TRANSFORMERS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Secondary Unit Substations

Low Voltage Transformers Sealed, General Purpose, Dry Type

INTERNATIONAL STANDARD

Primary and Secondary Electrical Distribution Systems

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Solid-Cast Versus Resin-Encapsulated Transformers

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

THE VALUE OF POWER FACTOR TESTING

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Multi-tap Transformers

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

An Overview of Lapp Insulator High Voltage Bushing Design


ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Explosion proof enclosures

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Transformer Design & Design Parameters

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

WINDING RESISTANCE TESTING

CRN A-F-G-E-HQQE 3x400D 50 HZ

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Transformer Bushings for GIS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

The following document contains information on Cypress products.

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Lightning Arresters P KVA P KVA. Description & Installation

WE-350 Series ¼ Turn Electric Actuator

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Single Phase Soft Starter

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Explosion-Proof Electric Unit Heaters

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Receiving, Installing, Operating and Maintaining Dry Type, VPI Sealed, Cast Coil and UNICLAD Transformers

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

Instructions for Secondary Unit Substation Transformers KVA, Three Phase

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Safely Installing, Maintaining and Inspecting Cable Trays

Power Transformers 10 to 100 MVA

Unified requirements for systems with voltages above 1 kv up to 15 kv

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Metal Clad Indoor Instrument Transformer for Plug-In Systems

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

TRANSFORMER DICTIONARY

Diesel Engine Driven Generators Page 1 of 6

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

INTERNATIONAL STANDARD

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Comparative study for cables and busbars

SECTION HEAT PUMPS

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

International Electrotechnical Commission Standards

Power Plant Electrical Distribution Systems

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

AC Electric Motors best practice

Table of Contents. TransformerIQ FAQs 1

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Distribution Voltage Regulators

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Installation Manual Version 7.3 IMPORTANT:

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

The Intelligent AX1 Switchgear for Medium Voltage

Transcription:

TM MAXI-CAST RESIN TRANSFORMERS A GROUP CBS COMPANY

TM Many models and sizes available from stock for same day shipment! CONTENTS Introduction...4 Application...4 MAXI-CAST Transformer View...5 Features...6-7 Section View...8 Construction...9-11 Quality Assurance...11 Technical Data...12-13 Specifications...14 3

INTRODUCTION Great progress has been made in the development and improvement of transformers over the last decade. The use of high quality insulation and the suitable selection of the coil structure design for high stress applications has advanced the design of the cast resin transformer. The MAXI-CAST transformer combines the advantages of liquid-filled and dry type transformers. Cast resin transformers are fabricated with an epoxy resin which has a special low viscosity formula mixed under a vacuum. The copper windings are completely embedded between layers of glass fiber and impregnated in a special process with pure resin mixed under vacuum conditions. This unique casting method makes it possible to assure voidfree epoxy penetration of both the inner layer and turn-to-turn insulation. After casting, the coils are cured in a temperature time sequence which is controlled by a microprocessor to guarantee full and stress-free adhesion of the resin to the conductors. It also provides a total safeguard against cracks under all circumstances. This result of the high technology application provides many unsurpassed characteristics. FEATURES/CHARACTERISTICS Moisture proof No partial discharge High overload capability Superior Impulse voltage strength Short-circuit damage resistance Thermal shock resistance Superior fire resistant design Maintenance free Environmentally safe Very low noise Very low operating cost APPLICATIONS MAXI-CAST transformers can be used in various fields. Here are just a few possible applications: Indoor or outdoor unit substations Industrial and petrochemical plants Offshore platforms Harmonic applications Extremely corrosive and dirty applications Low noise applications Water supplies Transit systems SCR power supplies Grid, ring or radial networks Station auxiliaries Pad mount applications 4

TM MAXI-CAST TRANSFORMER Lifting Lugs LV Terminal Name Plate Upper Frame HV Terminal Interphase Lead No Voltage Tap Changer Lower Frame Anti-vibration Rubber Wheel 5

FEATURES/CHARACTERISTICS 6 MOISTURE PROOF The complete casting of HV and LV coils under vacuum prevents the penetration of moisture into the winding and the breakdown by ionization. Therefore, it is suitable for both storage and operation in adverse environments, including prolonged storage in up to 100% humidity and is capable of being energized immediately after such storage without drying. NO PARTIAL DISCHARGE There is no possibility of partial discharge in MAXI-CAST transformers. Each high voltage coil is individually tested for partial discharge before assembly to ensure a partial discharge-free operation under all circumstances, and to guarantee the life expectancy of the insulation system. MAXI-CAST transformers are free of partial discharge at least up to 1.2 times of the rated voltage, and no visible corona at 2 times the rated voltage. (CORONA TEST CIRCUIT) HIGH OVERLOAD CAPABILITY Based on the high thermal time constant factor of the windings, MAXI-CAST transformers can be overloaded for considerably longer periods of time than liquid immersed or dry type transformers. It has a greater capability to withstand sudden momentary high overloads such as might be encountered in heavy traction or severe duty industrial applications. IMPULSE VOLTAGE STRENGTH MAXI-CAST transformers have impulse levels equal to liquid-immersed transformers. The coils are very resistant to impulse voltage. Impulse withstand levels to 200kv are available because of careful design and special structure. The impulse voltage stress of the HV coil is evenly distributed throughout the winding due to a suitable winding arrangement. SHORT CIRCUIT RESISTANT The coil construction provides the highest mechanical withstand capability. The dynamic short circuit strength of a MAXI-CAST transformer is greatly superior to that of liquid-immersed or dry type transformers. In the event of a maximum short circuit, MAXI-CAST transformers are not endangered mechanically, due to the dense glass fiber filling and the adhesion of epoxy resin to the conductors. In case of a short circuit, the conductors heat up much faster than the surrounding insulation. Therefore only a strong glass fiber reinforced design, as found in cast resin transformers can prevent cracking of the coils and failure. THERMAL SHOCK RESISTANCE Tensile and bending strength of glass fiber reinforced epoxy resin (used in the MAXI-CAST design) is appreciably higher than that of quartz powder filled resin (used by mostly other manufacturers) has the disadvantage of becoming brittle and tending to crack when exposed to low temperature. Due to the complete combination of epoxy resin and glass fiber, even the worst temperature fluctuation will not induce the cracking of the coils in MAXI-CAST transformers.

TM FEATURES/CHARACTERISTICS FIRE RESISTANT MAXI-CAST transformers have an inherently safe characteristic of self fire-extinguishing and fire resistance. So there would be no fear of spread of fire even if a fire took place in near by equipment. The transformers can be used indoors without fear of fire, and it is not necessary to provide additional measures for safety. (a) (b) (c) a) Ignited for 2 minutes on the surface of cast coil with acetelene torch b) As the torch was removed from the surface of burning resin c) The flame extinguished by itself after 15 seconds MAINTENANCE FREE Maintenance is almost completely eliminated. No checking of liquid level and no yearly dielectric test for moisture absorption is required. Due to the smooth coil surfaces, heavy dirt and dust build up is eliminated even under the worst circumstances. The recommended routine maintenance is an occasional visual or Infra-Red thermal inspection. ENVIRONMENTALLY SAFE MAXI-CAST transformers will not emit oil or toxic gases into the atmosphere. Therefore, they do not pollute the environment and are recommended strongly as a replacement for askarel filled (PCB) transformers. PCB is poisonous, chemically aggressive and can discharge dangerous gases at elevated temperatures. LOW NOISE The encapsulation of the core in a special resin and the design of the clamping mechanism have provided an appreciable noise reduction. Noise is also reduced due to the sound suppressing effect of the elaborate core cutting and the coil support elastic structure. COST SAVING If the advantage of MAXI-CAST transformers are taken into consideration at the planning stage, the overall costs of a power supply system can often be considerably reduced. They are sufficiently compact for convenient installation in a building where space is generally limited and have much smaller power loss than oilimmersed and dry-type transformers. Total costs are lower even though cast resin transformers may be more expensive than other transformers. Cost savings add low maintenance and longer operating life in all conditions. FEWER FAILURES Stanadard Insurance Company studies have shown failure rates in cast coil transformers to be less than 5% that of standard dry type transformers in some applications 7

MAXI-CAST TRANSFORMER SECTION 1 2 10 11 1 Lifting Lugs 2 LV Terminals 3 HV Coil 4 LV Coil Termination 5 Core Bandage 6 LV Coil 7 Pulling Holes 8 Lower Frame 9 Core Yoke 10 Core Bolt Insulation 11 Core Pressing Bolts 12 Upper Frame 13 Coil Clamp Adjustor 14 Tap Link 15 Resin Support Block 15A Resilient Pad 16 Core Leg 17 Tie Bars 18 HV Terminal 19 HV Taps 20 Anti-Vibration Rubber 21 Trolley Frame 22 Bi-directional Wheel 23 HV Conductors 24 Air Ducts for Cooling 25 LV Conductors 9 3 12 13 HV Coil 15 14 15A 16 17 4 24 5 18 19 6 LV Coil 20 7 21 25 8 22 8

TM CONSTRUCTION MAXI-CAST transformers prides itself in the ability to offer a wide variety of designs and configuations to satisfy most customer needs. Computers and CAD/CAM systems are used to quickly and accurately design and manufacture to meet specific customer requirements. CORE AND FRAME The core is made of the highest quality, cold-rolled, grain-oriented, high silicon content steel and acurately cut on the latest CNC machines. Three legs of the core are arranged in a single plane and interconnected with a yoke. The legs are arranged circular structure multi-ply step-wise design, and are carefully interlaced with stepwise epoxy arranged yokes. The core is mitered at a 45 angle and carefully stacked to obtain very low losses, exciting current and noise. The core is insulated on both sides of each lamination and protected against corrosion by a resin coating and grounded in accordance with required standards. The frame consists of upper and lower steel channels. It holds the core and coil together securely. The undercarriage is bolted to the bottom of the lower frame. Wheels enable the transformer to be moved either length -wise or side -wise. Lifting lugs and grounding terminals are fitted to the upper and lower frame respectively. To protect against corrosion, all steel parts are coated with epoxy paint. LOW VOLTAGE AND HIGH VOLTAGE WINDING High grade insulated copper wire is used in all winding construction. Turns are arranged in multiple sections and layers as dictated by design requirements. Cooling ducts are strategically placed within the windings to provide low thermal drop through thin sections of insulation, and provide smooth and even surfaces for effective convection or forced air cooling. The completed windings are placed in close tolerance with molds and cast under high vacuum conditions using a very low viscosity epoxy resin. The resin penetrates and saturates all portions of the windings. After the molds are filled with epoxy resin, they are moved into carefully programmed ovens where the epoxy resin is fully cured. Finished coils contain smooth surfaces to enhance heat transfer to cooling air, and also prevent dirt or dust build-up. The complete saturation and penetration of the resin results in a winding free of partial discharge, well above operating voltage conditions. Glass cloth and fiberglass mat render outstanding mechanical strength properties as well to the finished product. 9

CONSTRUCTION NO-VOLTAGE TAP CHANGER MAXI-CAST transformers are provided with a re-connectable link tap changing device on the high voltage side of the transformer. This can be operated with the transformer de-energized only to change the ratio of the transformer. The device is sturdy in construction, and the links are clearly identifiable as to the tap selected. COOLING FANS Forced cooling is a relatively simple method of increasing the capacity of cast resin transformers. This is especially advantageous for transformers which are highly loaded only for a few hours a day and then operated at a normal load for the rest of the time. Fans are mounted on both sides of the transformer base. Through the use of cooling fans, a capacity increase of 30-50% can be achieved with minimal efforts. It is also very effective at sites where the available space is limited and peak load conditions are only needed on a limited basis. TEMPERATURE MONITORING UNIT The temperature monitoring control system protects the coils against overheating due to increased ambient temperature or overload, and permits utilization of full transformer power at any required load cycle without hazard to the transformer. This system consists of a protective relay and temperature sensors buried in the upper portion of the low voltage coils so that the direct temperature measurement of the coils can be made. When the temperature of the coils exceeds its set value, a control relay operates and closes the contacts. This can activate an alarm or start fans to cool the transformer. 10

TM CONSTRUCTION ENCLOSURE MAXI-CAST transformers are normally supplied without an enclosure (Core and Coil only), Additional protection may be offered by an enclosure to protect against solid bodies and liquids. *ENCLOSURE CBS1 (Nema 1 indoor) This has protection against solid bodies greater than 12mm diameter and has louvered sheet steel or stainless steel walls. The top panel is removable and the floor is open to allow cables to be inserted easily through the floor. *ENCLOSURE CBS2 (Nema 3 outdoor) This is similar to enclosure CBS1 but also has protection against rain and blowing water up to 60 degrees from the vertical. Because this enclosure is used in outdoor applications it is equipped with a rain tight roof assembly and has hooded and filtered louvered walls. ASSEMBLY HV and LV coils are arranged coaxially and clamped rigidly. The support structure between the core and coils is resilient preventing the major part of vibrations and noise caused by magnetostriction. The noise level is dampened to a level equivalent to that of oil-immersed transformers. QUALITY ASSURANCE Quality assurance begins with a tight control of incoming materials and is continuous throughout the various steps of the manufacturing process. Quality control is carried through the testing of each transformer and ends only when the transformer is installed and operating. MAXI-CAST transformers are tested in accordance with ANSI and IEC standards prior to shipment, as noted below. Additionally, each high voltage coil is routinely tested before assembly as a means to verify the integrity of the epoxy impregnation. Notes: The MAXI-CAST factory has fully equipped laboratory facilities for testing cast epoxy resin transformers. Tests are performed as noted in the following table. NO. ITEMS ROUTINE TYPE SPECIAL TEST TEST TEST 1 Measurement of winding insulation resistance 2 Measurement of turns ratio 3 Phase-relation test: Polarity, angular displacement and phase sequence 4 No-load loss and exciting current 5 Load loss and impedance voltage 6 Applied potential dielectric test 7 Induced voltage dielectric test 8 Temperature rise test 9 Impulse voltage test 10 Measurement of sound level 11 Measurement of partial discharges 12 Short-circuit test 13 Heat cycle test 11

TECHNICAL DATA Temp. Rise 80/115/150C, 60Hz Class 5KV, BIL HV; 75KV/LV; 30KV. ANSI/IEEE C 57. 12. 01 Load Rated Impedance No-Load Loss Dimension (inches) Weight Power Type Voltage Loss (W) (lbs) (KVA) (%) (W) at 100 C A B C D E F G H 112.5 MC-1 12/5 5.75 450 2350 41.3 19.7 40.9 27.6 16.9 18.5 10.2 1.2 1210 150 MC-150/5 5.75 550 2900 41.3 19.7 47.2 27.6 16.9 18.5 10.2 1.2 1430 225 MC-225/5 5.75 700 3500 45.3 25.6 48.8 29.9 22.8 19.9 10.6 1.2 2120 300 MC-300/5 5.75 850 3800 45.3 25.6 53.1 29.9 22.8 19.9 10.6 1.2 2510 500 MC-500/5 5.75 1200 6300 53.5 25.6 58.3 34.6 22.8 22.2 11.8 1.2 3640 750* MC-750/5 5.75 1800 7800 55.1 29.5 67.7 36.6 24.1 23.8 12.4 1.9 4890 1000* MC-1000/5 5.75 2300 9000 59.1 29.5 72.8 38.6 24.1 24.4 13.0 1.9 6060 1500* MC-1500/5 5.75 3100 13500 66.9 37.4 82.7 44.5 29.9 27.2 14.4 1.9 7300 2000* MC-2000/5 5.75 3600 16600 70.9 37.4 88.6 46.9 29.9 27.8 14.6 1.9 9900 2500* MC-2500/5 5.75 4600 19000 78.7 40.2 95.3 46.9 29.9 27.8 14.6 1.9 11000 * Indicates stock units ready to ship. NOTE: These are maximum dimensions. Actual production transformer may be slightly smaller. 12

TM TECHNICAL DATA Temp. Rise 80/115/150C, 60Hz Class 15KV, BIL HV; 110KV/LV; 30KV. ANSI/IEEE C 57. 12. 01 Load Rated Impedance No-Load Loss Dimension (inches) Weight Power Type Voltage Loss (W) (lbs) (KVA) (%) (W) at 100 C A B C D E F G H 112.5 MC-1 12/15 5.75 520 2700 44.1 25.6 45.3 30.0 22.8 20.0 10.4 1.2 1370 150 MC-150/15 5.75 650 3200 41.1 25.6 51.6 30.0 22.8 20.0 10.4 1.2 1590 225 MC-225/15 5.75 850 3700 51.2 29.5 54.7 33.5 24.1 23.2 11.2 1.9 2360 300 MC-300/15 5.75 1000 4300 51.2 29.5 61.4 33.5 24.1 23.2 11.2 1.9 2820 500 MC-500/15 5.75 1550 7100 59.1 29.5 68.9 39.4 24.1 27.6 12.8 1.9 4270 750* MC-750/15 5.75 2100 8600 63.0 37.4 74.4 41.7 30.0 27.8 13.2 1.9 5580 1000* MC-1000/15 5.75 2750 9000 68.9 37.4 76.8 45.7 30.0 28.1 14.4 1.9 7120 1500* MC-1500/15 5.75 3500 12000 70.0 40.2 82.7 46.9 34.3 29.9 14.8 1.9 8300 2000* MC-2000/15 5.75 4600 16600 78.7 40.2 91.7 51.6 34.3 31.7 15.9 1.9 11660 2500* MC-2500/15 5.75 5200 19000 83.5 40.2 98.4 51.6 34.3 31.7 15.9 1.9 13400 * Indicates stock units ready to ship. NOTE: These are maximum dimensions. Actual production transformer may be slightly smaller. 13

SPECIFICATION SPECIFICATION DATA MAXI-CAST transformers are normally available with specification as follows: Rated Voltage HV coil: Up to 36KV LV coil: 0.48-4.16 KV * MAXI-CAST transformers with multiple high voltage connections can also be supplied. Tap Range Standard: ±2.5%, ±5% * Other ratings are available by arrangement. Power Capacity Single phase. 20-2,000 KVA Three phase: 50-10,000 KVA Frequency: 50Hz, 60Hz Typical % impedance voltage: 4-8% Connections HV coil: Delta LV coil: Wye with neutral point * Other connections are available to meet requirements. Temperature ratings (according to ANSI C-57) HV coil: Class F LV coil: Class F Max. ambient temperature: 40 C Temperature rise limitation: 150 C Tolerance (according to ANSI C-57) Total losses: +10% Component losses: +15% (No-load and load losses) No-load current: +30% Impedance voltage: ±10% (at rated current) Voltage ratio: ±0.5% or 1/10 of measured impedance voltage at rated current. STANDARDS MAXI-CAST transformers conform to the requirements of ANSI/IEEE C57-12.01 (1979) standards. However they can also meet the requirements of the following standards, upon request: ANS IEC726 (1982) General requirements for dry-type distribution and power transformers BS-171 (1978) Power transformers CSA standard C9-M (1981) Dry-type transformer AS2374 (1982) Power transformer VDE 0532 (1982) * Transformers for rectifier applications and other special purposes can be supplied according to the client's specification (Rapid Transit System, Air and Iron Core Reactors, Precipitator Transformers etc.) ACCESSORIES NORMALLY PROVIDED ACCESSORIES Terminal screws and links for HV taps Nameplate Ground wire clamping screw Protective cap for HV taps Lifting lugs Danger labels Installation manual OPTIONAL ACCESSORIES PTC thermistor & relay unit Wheels Dial-type thermometer Anti-vibration pads Enclosure Anchor bolts SPECIAL ACCESSORIES Cooling fans and control relay 14

TM GROUP CBS, INC. WE PROVIDE QUALITY MAINTENANCE, REPAIR AND SUPPLY SERVICES WORLDWIDE www.electrical911.com www.groupcbs.com Circuit Breaker Sales Co., Inc. World's largest inventory of low and medium voltage circuit breakers. Millions of parts in stock. Complete service, remanufacture and upgrade capabilities including building new or matching existing switchgear lineup from 480V to 34.5kV. Tel: 800-232-5809 www.circuitbreakersales.com Arc Technology, Inc. Electrical contact retipping and replacement for oil switches, air switches, tap changers, regulators, circuit breakers, motor starters and reclosers. Tel: 253-735-0485 www.arc-technology.com CBS Power Products, Inc. New alternative utility and industrial power products. Transformers, vacuum circuit breakers and other power apparatus. Tel: 972-250-2500 www.cbspowerproducts.com Northwest Circuit Breakers, Inc. Serving the Pacific Northwest with shop or field service, repair, upgrade or replacement of power system apparatus. Tel: 253-735-0192 www.nwcircuitbreakers.com Solid State Exchange & Repair, Inc. Service and support for all brands and types of solid state power electronics including circuit breaker trip devices, rating plugs, protective relays and more. Tel: 940-243-3731 www.solidstaterepair.com Circuit Breaker Sales & Repair, Inc. Servicing the Gulf Coast with shop or field service, repair, upgrade or replacement of power system apparatus. Tel: 713-921-4545 www.cbsalesandrepair.com Transformer Sales Co. Dry, cast coil and liquid filled transformers up to 34.5kV. Tel: 940-665-4484 www.transformersales.com Instel Power Services, Inc. Serving the Southeast with onsite testing, maintenance and repair services. Full NETA shop specializing in onsite maintenance and power quality monitoring. Tel: 864-288-0991 www.instelpower.com Sentinel Power Services, Inc. Serving the Central U.S. with onsite testing, maintenance and repair services for low and medium voltage substations, switchgear, transformers, circuit breakers and protective relays. Tel: 800-831-9550 www.sentinelpowerservices.com Astro Controls, Inc. Sales and service for all types of industrial molded case circuit breakers and motor controls. Tel: 800-289-2757 www.astrocontrols.com

http://www.lgindustrialsystems.com P.O. Box 1557 Gainesville, Texas 76240 Tel: 940-665-6026 Fax: 940-665-4681 E-mail: info@groupcbs.com P.O. Box 703766 Dallas, Texas 75370 Tel: 972-250-2500 Fax: 972-250-2501 E-mail: info@cbspowerproducts.com