DELTABEAM COMPOSITE BEAM

Similar documents
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE

Chapter 3 Pre-Installation, Foundations and Piers

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

INSTRUCTIONS FOR USE

Hanson Building Products. precast basement solutions

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

Detailing of Reinforcment in Concrete Structures

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Understanding BS EN 771-3: Aggregate concrete masonry units

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Embedded Parts Introduction - Anchors

Long Carbon Europe Sections and Merchant Bars. Slim Floor. An innovative concept for floors

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Technical Assignment 2 TABLE OF CONTENTS

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

HPM Rebar Anchor Bolt. For bolted connections. Technical Manual. European Technical Approval ETA-02/0006. Version: Peikko Group 01/2015

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Eurocode 4: Design of composite steel and concrete structures

Design and Construction of Cantilevered Reinforced Concrete Structures

PPM High-Strength Anchor Bolt

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Index Series Prestressed Florida-I Beams (Rev. 07/12)

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Residential Deck Safety, Construction, and Repair

Safe & Sound Bridge Terminology

US 51 Ohio River Bridge Engineering and Environmental Study

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Preliminary steel concrete composite bridge design charts for Eurocodes

PART 1 GENERAL 1.1 SECTION INCLUDES

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

SECTION 1 GENERAL REQUIREMENTS

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

Chapter 2 Basis of design and materials

High Strain Dynamic Load Testing of Drilled Shafts

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

EAST LYME HIGH SCHOOL

Prestressed Concrete I-Beam and TxGirder Haunch Design Guide

SECTION PIPE HANGERS AND SUPPORTS

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Chapter. Restoration of Damaged Structures

Construction of precast reinforced concrete structures. Prefabricated reinforced concrete construction:

ENGLISH FORK GUIDE 2013

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

39HQ Airovision Air Handling Units

Introduction. Eurocodes. Specification. Cost

METHOD OF STATEMENT FOR STATIC LOADING TEST

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

APPENDIX H DESIGN CRITERIA FOR NCHRP PROJECT NEW BRIDGE DESIGNS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

INSTALLATION. General. Important Note. Design. Transport

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

HOPLEYS OPENWEBSTEELJOISTS

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Formwork for Concrete

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Joist. Reinforcement. Draft 12/7/02

Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span

Timber Decks. Technical Note. March 2007

Field Damage Inspection and Static Load Test Analysis of Jiamusi Highway Prestressed Concrete Bridge in China

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

Design Manual to BS8110

Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC October 27, 2015 Session 26

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Connection Solutions

Packaged Terminal Air Conditioner Wall Sleeve Installation

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

WORLD S TALLEST TIMBER BUILDING, BERGEN

INTRODUCTION TO LIMIT STATES

Forensic engineering of a bored pile wall

How To Build A Gambrel Roof And A Gable End Roof

Schöck Isokorb type KST User Selection Guide. Schöck Isokorb type KST Blindtext

Eurocode 2: Design of concrete structures

Structural Products. CI/SfB (23) Nh2 P356 August 2008

The ACR : Advanced Design Features for a Short Construction Schedule

Phosphoric Acid Anodized Aluminum Honeycomb

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Fire safety in timber buildings

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Analysis II Façade Redesign: Architectural Precast Panels

Composite Construction with KÖCO- Stud Welding Technology IMPRESSIVE TECHNOLOGY 6/

Transcription:

DELTABEAM COMPOSITE BEAM Type approval Finland: VTT-RTH-03040-07, Germany: Z-26.2-49, UK: BBA 05/4204, Russia: РОСС FI.СЛ19.Н00323, Czech Republic: 204/C5/2006/060-025293, Slovak: TO-08/0021 Replaces the brochure 5/03 4/2007, updated reprint

DELTABEAM Benefits of Deltabeam EVEN CEILINGS: allows flexible layouts through the whole life cycle of the building and easy HVAC installations below or inside the floor. COMPOSITE ACTION: no additional work at site, achieved by the infill concrete HIGH FIRE RESISTANCE: no additional work at site, achieved by the infill concrete MAJOR SAVINGS IN MULTI STOREY BUILDINGS: due to shallow structure, the total height of the building can be reduced or extra floor can be built: savings in facade material costs and maintenance (air-condition, heating) TECHNICAL APPROVALS: Finland, UK, Czech Republic, Russia and Germany INTENSIVE RESEARCH: ongoing research program with University of Oulu, dozens of loading test, including fire tests TECHNICAL SUPPORT: with short response time at every stage of the project DESIGN CALCULATIONS: design calculations and fabrication drawings for each beam will be delivered to the client EXPERIENCED TEAM: impressive reference list starting from 1989, more than 6000 projects HIGH PRODUCTION CAPACITY: high quality from multiple factories around the Europe EASY AND FAST INSTALLATION: light and easy hoisting, simple to assemble SHORT TOTAL ASSEMBLY TIME: hollow core - Deltabeam construction reduces total assembly time compared to traditional methods FREE FLOOR BELOW: no obstacles to work on floor below, minimum amount of propping if any FLEXIBLE PRODUCT RANGE: flexible beam types and details, composite columns, erection work and auxiliary tools for erection groups COMMON MATERIALS: basic structural steel, reinforcement and concrete used MODERN PRODUCTION TECHNOLOGY: robots weld and paint, modern plasma cutting QUALITY AND ENVIROMENT SERTIFICATES: ISO9001, ISO14001 and EN729-2 Peikko benefits reliable: passed demanding test program competitive price and delivery time economical and easy to use in designing, manufacturing and installation of the elements

CONTENTS 1. DESCRIPTION OF THE SYSTEM...4 2. DIMENSIONS AND MATERIALS...4 3. MANUFACTURING...6 3.1 Manufacturing method 6 3.2 Manufacturing tolerances 6 3.3 Painting 6 3.4 Manufacturing markings 6 3.5 Quality control 6 4. CAPACITY CURVES...6 5. APPLICATION...9 5.1 Limitations for application 9 5.2 Design principles 9 5.2.1 Design phases and delivery processes 10 5.2.2 Selecting the Deltabeam profile 11 5.2.3 Connection details of Deltabeam 11 5.2.4 Expansion and working joints of the slabs 12 5.2.5 Voids and joints 12 5.2.6 Supporting beams during installation 12 5.2.7 Fire protection and environmental classes 12 5.2.8 Surface finishings 12 5.2.9 Basic design information 13 6. INSTALLATION... 13 6.1 Deliveries 13 6.2 Storage on site 13 6.3 Lifting and moving 13 6.4 Installation 14 6.4.1 Beam fixing 14 6.4.2 Supporting the beams 14 6.4.3 Installing the slabs 14 6.4.4 Concreting 15 7. THINGS TO DO WHEN TOLERANCES ARE EXCEEDED... 16 7.1 When the corbel is on too low level 16 7.2 When the corbel is on too high level 16 7.3 When the beam doesn t reach support point 16 7.4 When anchoring bolts don t meet bolt holes of the beam 16 7.5 When transverse reinforcement doesn t meet web holes 16 7.6 When tolerances of Gerber-joint are exceeded 17 7.7 When the Deltabeam is too long 17 7.8 When the length or position tolerances of hollow-core slabs fall below or are exceeded 17 INSTRUCTIONS FOR FILLING IN THE DATA SHEETS... 17 www.peikko.com 3

DELTABEAM 1. DESCRIPTION OF THE SYSTEM Deltabeam is a hollow steel-concrete composite beam made from welded steel plates with holes in the sides. It is completely filled with concrete after installation on site. Deltabeam acts as a composite beam with either hollow-core, composite, or thin shell slabs, and in-situ casting. Deltabeam can have a fire class rating as high as R120 without additional fire protection. Figure 2. Deltabeam with light weight pre-cast concrete element and in-situ casting. Figure 1. Deltabeam with thin shell and hollow-core slabs 2. DIMENSIONS AND MATERIALS Materials and standards: Plates S420 EN 10025-3, EN 10149-2 S355J2+N EN 10025-2 Rebars A500HW SFS 1215 (yield limit 500 MPa) Figure 3. Deltabeam air holes casting hole top plate web web hole rebars bottom plate beam ledge 4

Table 1. Dimensions of Deltabeam [mm] Table 2. Dimensions of edge beams [mm] b2 b2 57 57 h Ø h Ø d2 b1 b B b1 d2 b1 B b 20 b B b1* b2 d2 h Ø** D20-200 395 97.5 100 5-25 200 80 D20-300 495 97.5 180 5-25 200 80 D20-400 660 130 278 5-25 200 80 D22-300 495 97.5 170 5-25 220 80 D22-400 660 130 270 5-25 220 80 D25-300 495 97.5 155 5-25 250 150 D25-400 660 130 255 5-25 250 150 D26-300 495 97.5 148 5-25 265 150 D26-400 660 130 245 5-25 265 150 D30-300 495 97.5 130 5-25 300 150 D30-400 660 130 230 5-25 300 150 D32-300 495 97.5 110 5-25 320 150 D32-400 660 130 210 5-25 320 150 D37-400 660 130 180 5-25 370 150 D37-500 760 130 278 5-25 370 150 D40-400 660 130 180 5-25 400 150 D40-500 760 130 278 5-25 400 150 D50-500 760 130 230 5-25 500 150 D50-600 860 130 330 5-25 500 150 *standard size unless the customer otherwise defines (minimum 20 mm) **c/c distribution for web holes is always 300mm b B b1* b2 d2 h Ø** DR20-215 335 100 148 5-25 200 80 DR20-245 365 100 180 5-25 200 80 DR22-250 370 100 180 5-25 220 80 DR25-260 380 100 180 5-25 250 150 DR26-230 350 100 148 5-25 265 150 DR26-260 380 100 180 5-25 265 150 DR26-290 410 100 210 5-25 265 150 DR26-325 445 100 245 5-25 265 150 DR30-270 390 100 180 5-25 300 150 DR32-250 370 100 148 5-25 320 150 DR32-285 405 100 180 5-25 320 150 DR32-310 430 100 210 5-25 320 150 DR32-365 465 100 245 5-25 320 150 DR37-325 475 130 210 5-25 370 150 DR40-295 445 130 180 5-25 400 150 DR50-350 500 130 210 5-25 500 150 *standard size unless the customer otherwise defines (minimum 20 mm) **c/c distribution for web holes is always 300mm Beam s height and width can also be customized by customer within the maximum and minimum range in these tables. Minimum delivery for custom sizes is 200m. By using the special beams delivery time is longer and the price has to be checed because of the higher costs. www.peikko.com 5

DELTABEAM 3. MANUFACTU- RING 3.1 Manufacturing method Plates Plasma, flame and mechanical cutting Rebars Mechanical cutting Welding MAG by hand or with robot Welding calss C (SFS-EN 25817) Figure 3. Robot welding 3.2 Manufacturing tolerances Length L ± 5 mm Width B ± 5 mm Height h ± 3 mm Lateral flexure f p f p L / 650 (measured from the ledge and web angle) Flexure f n ± L / 650 (in relation to the intended pre-cambering) Size and location of holes ± 5 mm Location of couplings ± 5 mm Location of supp. parts (c-profile, cambers, formwork sheets) ± 5 mm 3.3 Painting example, when the beams are exposed to weather at the sites, it is recommendable to consider a thicker paint coating. The customer must do the final painting on site. 3.4 Manufacturing markings The name of the site, beam type, weight and type approval are marked on the beam. 3.5 Quality control Quality control is being carried out according to the requirements of the National Building Code of Finland. Peikko Finland Oy Deltabeam has a quality control agreement with the VTT Technical Research Centre of Finland. Deltabeam has the type approval VTT-RTH-03040-07 granted by the VTT Technical Research Centre of Finland, British certificate 05/4204 granted by BBA, German type approval Z-26.2-49, Czech approval 204/C5/2006/060-025293, Russian approval РОСС FI.СЛ19.Н00323, Slovak approval TO- 08/0021 and quality standard for welding ISO 3834-2 granted by Inspecta. 4. CAPACITY CURVES The load-bearing capacity Pd [kn/m] is presented for simply supported beams according to the type of the beam. The following defaults have been used when calculating the curves: Structural steel S355J2+N Concrete grade C25/30 (K30-2) Deflection caused by dead load is eliminated by precambering Loads that are included into the capacity curves - dead load 1.25 kn/m² (50 mm topping) - dead weight of the Hc unit (equal depth with the beam) 6 The lower surface of the beam primed to SA2.5 40 μm. Other painting and surface treatment are agreed upon separately with the customer. For

Deltabeams D50, D40 and D37 140 Note! Hollow-core slab and beam interaction requirements are not taken in bearing capacity values Beam load [kn/m] Beam load [kn/m] Beam load [kn/m] 120 100 80 60 40 20 0 6 7 8 9 10 11 12 13 Beam span [m] Deltabeams D32, D26 and D25 140 120 100 80 60 40 20 4 5 6 7 8 9 10 Beam span [m] Deltabeams D22 and D20 140 120 100 80 60 D50-600 D50-500 D40-500 D40-400 D37-400 D37-500 D32-400 D32-300 D26-400 D26-300 D25-400 D25-300 D22-400 D22-300 D20-400 D20-300 D20-200 40 20 2 3 4 5 6 7 8 Beam span [m] www.peikko.com 7

DELTABEAM Deltabeams DR50, DR40, DR37 and DR30 165 Note! Hollow-core slab and beam interaction requirements are not taken in bearing capacity values Load [kn/m] Load [kn/m] Load [kn/m] 145 125 105 85 65 45 25 4 5 6 7 8 9 10 Beam span [m] Deltabeam DR32 165 145 125 105 85 65 45 25 4 5 6 7 8 9 10 Beam span [m] Deltabeams DR26, DR25, DR22 and DR20 145 125 105 85 65 45 DR50-350 DR40-295 DR37-325 DR30-270 DR32-365 DR32-310 DR32-285 DR32-250 DR26-325 DR26-290 DR26-260 DR26-230 DR25-260 DR22-250 DR20-245 DR20-215 25 4 5 6 7 8 Beam span [m] 8

5. APPLICATION Figure 6. Length of Deltabeam supporting ledge. 5.1 Limitations for application The bearing capacities of the Deltabeams have been calculated for static loads. Greater partial safety factors must be used for dynamic loads and fatigue loads on a case by case basis. 5.2 Design principles Figure 4. Minimum distance of web holes from the end of the beam h = 200 x 160 or h = 265 x 195 h x 300 std. hole pattern 20 80 mm, D-type when b 300 and DR-type when h 320 110mm, other beam types { The bearing support distance (to hollow-core slab or other deck) may vary from standard requirement, see figure 6. If the bearing support distance is shorter than shown in figure 6, Peikko Finland Oy must be consulted. Using smaller bearing surface impacts the design, dimensioning and cost of Deltabeam. Figure 7. Deltabeam can also be made as either a single-span or a cantilever. The shear joint between concrete and steel beam is formed by the dowel action of the web holes located in the web of the beam. Static loading tests have proven that the interaction rate is complete. The filling cast functions as cross-section compression components in the final structure. Transverse reinforcement is described in figure 5, the reinforcement is anchored from the end of the slab over the length of the anchoring zone of the beam. With hollow-core slabs, the location of web holes is adjusted to the joints between the slab elements. Figure 5. Minimum transverse reinforcement A max s Ø12 c/c 1200 + reinforcement for torsion reinforcement for accident situation www.peikko.com 9

DELTABEAM 5.2.1 Design phases and delivery processes Phases of designing a standard delivery: Chief structural engineer Peikko Finland Oy Deltabeam 1. Preliminary design Selection of framework alternatives Selection of floor structure Cost comparison Selection of beam type and joint details Technical consulting Floorplans with load data and cross-sectional drawings 2. Quotation phase Basic data: project floorplans and quotation for the project (loads, perforations, fire protection rating, flexural limits, surface treatments) Preliminary dimensioning of beams to the project Checking the interaction rate between the hollowcore slab and the beam Quotation calculation 3. Actual design Design meeting Beam dimension data sheet Specification of joint details Implementation plans Marking of beam identification codes to floor drawings* Installation plan (including supporting plan) Technical consulting Complete basic project in paperwork is copied and sent or e-mailed to Peikko Finland Oy Deltabeam *each beam has unique identification code 4. Beam strength calculation Beam strength calculations and structural drawings to the chief structural engineer/customer Beam data for the hollow-core slab designer Installation instructions of the beams to the customer Peikko Finland Oy Deltabeam will carry out detailed project-specific measuring in the implementation phase. Then, the functional and ultimate strength properties even in case of fire are checked. Also the required pre-cambering of the beam is defined. Composite functioning between the hollow-core slab and Deltabeam are checked according to Concrete Association of Finland official concrete code chart no. 18. Deltabeam is designed to ensure hollow-core slabs require no additional support or props during installation. 10

5.2.2 Selecting the Deltabeam profile The preliminary selection of beam type is made on the basis of tables 1 and 2 (page 5) and the bearing capacity curves / pre-selection software. The pre-selecting software can be downloaded from Peikko s website www.peikko.com. The height of the Deltabeam can be 185-500 mm. Maximum length is 12,9-13,4 m depending on used plate material. It is more economical to use Deltabeam for the short chord and slabs in the direction of long chords. Intermediate beams (D) A site-specific special type can be used if necessary. The width and/or height of the special type departs from the normal dimensions. If Intermediate beams are used as edge beams with formwork sheet, then the fire protection of the free side is covered with concrete. 5.2.3 Connection details of Deltabeam The structural engineer designs the connection details of the beam. The connection must be designed in a way that the support reactions of the beam are transferred to the supportive structure (e.g. column, wall or another beam). This supportive structure must be designed to bear the forces from the beam. In column beam joints, it is recommended to use the PCs corbel designed especially for the steel beam. Edge beams (DR) The Delta edge beam is designed to serve as a slab edge beam when a narrower Deltabeam is needed and the vertical side is protected from fire by other structures. The edge beam can also be used on aperture edges, which usually require separate fire protection for the vertical web. The need for fire protection must be determined on a case-by-case basis. Width is determined on a case-by-case basis. Beam ledge height may be varied to accommodate differing slab profiles (see figure 8). Figure 8. Deltabeam with elevated ledge (left) and with formwork sheet (right). Stress and torsion during installation must be taken into account when designing the joint detail and supportive structure. Indicative connection details are described in the Deltabeam design folder and on Peikko s home page at www.peikko.com. The bottom plate can be cut at the end of the beam according to the joint detail of the project and the data sheet of the beam to be, e.g. skewed or arched. This way, the appearance of the connections will be finished. Peikko Finland Oy Deltabeam sizes the beam according to the joint details. Peikko Finland Oy Deltabeam also designs the internal beam connections (cantilever and side joints). Figure 9. Deltabeam with round column www.peikko.com 11

DELTABEAM The installation support is located at the end of the beam on the load side, near the web and bottom plate joint. Supports can only be removed when the slab cast and beam infill is cast have fully hardened. 12 5.2.4 Expansion and working joints of the slabs A transverse expansion joint is built into the console coupling by encasing the inside of the beam end joint to it so that there is room for movement after casting. A longitudinal expansion joint is placed at the beam ledge. Working joints are placed on a case-by-case basis so that they can be taken into account when performing strength calculations. 5.2.5 Voids and joints It is preferable to have all perforations and voids made at the factory. Machining of the beam is performed by flame cutting or drilling. The structural engineer marks the information on voids and joints to the data sheets. Peikko Finland Oy Deltabeam must always be contacted if any changes are to be made. All on-site connections in the beam are to be installed in compliance with the instructions given by the structural engineer. If additional connections are required, Peikko Finland Oy Deltabeam must be contacted. 5.2.6 Supporting beams during installation The structural engineer makes the installation and supporting plans for beams. Due to its box-like structure, the Deltabeam is capable of transferring the stresses of an eccentric load back to the column. If the installation plans don t tell otherwise, Deltabeam has to be always supported. If a Deltabeam is bearing on the end of a wall, the beam must always be propped until the concrete has been matured. When the Deltabeam is used to transfer floor loads to a wall-type beam, the beam must be kept free from loading until the installation/casting of the intersecting floor is complete. Installation supports cannot be removed until the upper wall is capable of bearing the full floor load. 5.2.7 Fire protection and environmental classes Rebars installed inside the beams at the works and webs act as load-bearing structure in the event of a fire. In the design phase, the beam is dimensioned in compliance with the fire class rating of the building, and rebars are used when needed. The fire rating of Deltabeam is based on combustion tests and the dimensioning guidelines obtained from them. Deltabeam can have a fire class rating as high as R120 / R180. Edge beams (DR) The vertical side of the edge beam must be protected from fire by other structures or materials/finishes. 5.2.8 Surface finishings The Deltabeam is rust-proofed or hot-dip galvanised. State-of-the-art surface coating techniques also ensure surface durability during transport and installation. When the underside of the beam is finished in the same way as the slab, the Deltabeam can also be left exposed, if desired.

5.2.9 Basic design information The basic information needed for the fastest manufacturing and strength calculation of Deltabeams: Floorplans with beam codes and load data, and all information affecting loading, e.g. continuity of slabs. Note: The beams are installed in such a way that the identification codes read in the correct way (as marked in the element chart). Connection details of the beams. A4 data sheets. Note: the data sheets must be made in such a way that the codes read in the correct way. See the instructions on page 10. List of beams. If the basic information is provided as described above, and connection details are standard, delivery time is 6 working weeks from receiving of the basic information. In other cases delivery time varies from 6 to 12 weeks depending on the accuracy of basic information provided and difficulty of details. Instructions for filling in the data sheet and an example sheet on pages 17 18. The data sheet pictures, beam list form and stadard details can also be downloaded from Peikko s website at www.peikko.com. 6. INSTALLATION 6.1 Deliveries Deltabeams are delivered to the site according to agreed project schedule. Beams of different lengths cannot be loaded at the factory in order of installation. The beams are marked with identification codes in accordance with the drawings. 6.2 Storage on site Deltabeam parts that remain exposed are painted with corrosion protective primer. In long-term storage, the beams must be covered. Struts are used under the beams to protect the painted surfaces. When storing beams in piles, the load-bearing capacity of the foundation must be checked. 6.3 Lifting and moving When erecting, it has to be observed that the beams are installed in the same direction as marked on element chart. Beams can be lifted and moved using ordinary lifting equipment, cranes or forklifts. The beam s web holes serve as attachment points for lifting lugs. The weight of the beam is marked on the beam label. www.peikko.com 13

DELTABEAM 6.4 Installation Beams are installed according to appropriate installation plan. The beams are installed in a way that the identification codes read in the same direction as marked in element chart. Figure 10. Element chart The width of the supporting surface is in compliance with the instructions of the supplier of the hollow-core slabs. D113 D114 D115 +111.50 Figure 11. Position of the end of a hollow-core slab in relation to Deltabeam D127 D128 D129 14 6.4.1 Beam fixing Connection details are specified in the structural plan in a project-specific way. The supplies needed for internal beam connections (cantilever and side connections) are included in the delivery. All beams must be fixed before slabs can be installed. This way movements of the beams can be prevented. Beam s weight is not effective enough to stabilize the frame during installation of the slabs. 6.4.2 Supporting the beams The beams are supported before installing the slabs in compliance with the installation and supporting plan made by the engineer. See chapter 5.2.6. 6.4.3 Installing the slabs All beam support and fasteners indicated in the plans must be securely installed, tightened or welded before the installation of the slabs. After the slabs are installed, the necessary formwork, edge forming and slab reinforcement will be carried out. Every join between the slabs must be reinforced with minimum of Ø12 rebar. 20 Hollow-core slabs The elements are installed directly onto the beam ledge. Thin-shell, composite and in-situ cast slabs The composite steel sheet and thin-shell slab are installed directly onto the beam ledge. The composite sheet is supported at the same elevation as the beam. No room for settlement should be allowed. Thin-shell slabs are supported at the same nominal camber as the floor. Deltabeam s precambering ensures the straightness of the beam

after casting. In-situ cast slabs are formed at the nominal level. The base of the beam is at the same level as the underside of the slab. The formwork is installed under the beam ledge 6.4.4 Concreting Deltabeams are concreted in conjunction with slab casting or the joint casting of hollow-core slabs. Deltabeam s filling casts are usually dimensioned at the same strength rating as the joint casts. The usual concrete grade is C25/30 (K30-2). Recommended minimun stone size of aggregate of Deltabeam infill concrete is 8 mm, absolute maximum is 18 mm.the properties of mixed concrete are determined according to the project and methods used in compliance with the concreting plan. The Deltabeam must be cast completely in order for it to possess the properties of a composite beam. Casting must be performed in one pour. Steps in concreting: 1. Ensure that the formwork and reinforcement are in place and clean. 3. If there are any formwork sheets on the edge beams, extreme caution must be taken during casting to avoid damaging or buckling the sheets when using a vibrating poker. 2. Filling is performed by inserting a pipe into the beam through casting ports. Begin filling the beam from the centre of the beam. The fill level of the beam can be checked through the air holes. Fill consistency can be checked using a vibrating poker. www.peikko.com 15

DELTABEAM 16 7. THINGS TO DO WHEN TOLERANCES ARE EXCEEDED Chief structural engineer or element designer must be contacted, and correction has to be always done according to correction plan done by chief structural engineer or element designer. 7.1 When the corbel is on too low level Chief structural engineer or element designer does the plan for correction with the consultation from Peikko Finland Oy. Without a proper correction plan the beam s end plate can not be altered or changed. Corbel s height can be increased with steel plate or beam s end plate can be changed. If the beam can be fixed according to original plans (bolts, welding), small (max 10mm) height differences can be leveled by welding plates on the top of the console tube. If corbel s height is increased with steel plate, the corbel s supporting surface must remain identical to original. Additional steel plates must be fixed by welding. If the difference in height level is greater than 10mm, the beam s end plate must be changed. 7.2 When the corbel is on too high level Chief structural engineer or element designer does the plan for correction with the consultation from Peikko Finland Oy. Without a proper correction plan the beam s end plate can not be altered or changed. There are few alternatives to fix this kind of problem. The link in the beam s end plate can be cut higher, or the end plate can be changed. 1. If the new end plate needs to be thicker than the original, Deltabeam may have to be shortened. 2. It is also possible to design end plate, that is as thick as the original, but greater in height. This way shortening of the Deltabeam can be avoided. 7.3 When the beam doesn t reach support point Deltabeam requires supporting surface defined in construction design. Chief structural engineer or element designer does the plan for correction with the consultation from Peikko Finland Oy. Without a proper correction plan the beam can not be extented. If the required extension is 150mm or less, the extension can be made directly to the end plate, or new, stronger end plate can be made. If extending of the beam is not possible, a new Deltabeam with accurate length has to be made. 7.4 When anchoring bolts don t meet bolt holes of the beam The bolt holes in top and bottom plate of the beam can be expanded in the direction of length, with the maximum factor of 1.5 (for example: 50mm to 75mm). The bolt holes cannot be expanded in the direction of width without permission from Peikko Finland Oy. Doing this may require the beam to be strenghtened. To expand bolt holes located in the beam s web, a permission has to be asked from Peikko Finland Oy. Any holes in weds or flanges of Deltabeam should not be enlarged by cutting them freen hand, one should always use a template or, which is more preferable, drill or use something similar mechanical method. 7.5 When transverse reinforcement doesn t meet web holes The web holes (Ø150 or Ø80) of the Deltabeam connot be expanded. Transverse reinforcement cannot be omitted, and they must be anchored inside Deltabeam. Chief structural engineer or element designer does the plan for correction with the consulta-

tion from Peikko Finland Oy. Without a proper correction plan new holes cannot be made to Deltabeam s web. 7.6 When tolerances of Gerber-joint are exceeded The tolerance in beam s length for Gerber and side joint is +5 / -10mm. The connection is designed so that 5mm shim plate is set to every joint after the Deltabeam is installed, but before tightening of the bolts. Check if the shim plate is used in other joints of the beam line. 1. By adding or removing the number of shim plates from other joints within the allowed tolerances, it may be possible to solve the problem. 2. The shim plates can be used for maximum thickness of 15mm. If the problem can not be resolved with the use of shim plates, the joint has to be re-designed, and the end plate of the corresponding Deltabeam must be changed. 7.7 When the Deltabeam is too long The correction plan is always done by Peikko Finland Oy. Typical procedure is the following: the end plate of Deltabeam is removed, beam is shortened and the end plate is welded to the beam according the instructions from Peikko Finland Oy. 7.8 When the length or position tolerances of hollow-core slabs fall below or are exceeded The correction plan is always done by Peikko Finland Oy. The situation concerns the strength of the Deltabeam during installation, because the stress differs from planned. Also the strength of the beam connections must be checked, because of possibly greater torsion. INSTRUCTIONS FOR FILLING IN THE DATA SHEETS The data sheet must be made so that the beam code in the floorplan reads in the correct way. Beam ID (characters allowed: alphabets, numbers, dashes and underscores) without beam type DR edge beam is read on slanting edge s side - take this into account when marking the beam IDs to the data sheet Beam code Beam length Fire class rating Location of web holes adjusted to the joints between the hollow-core slabs, measurement from the left end of the beam Numbered joint details of the beam Degrees of angle of the possible skew of the ends of the beam Location of possible intermediate supports Furnishing of the beam when necessary: Formwork sheets; height, length and location Elevation of the ledge; height, total length and location of the profile Elimination of ledges; width, length and location of the eliminated ledge Edge joints; measurement from the left end to the centre line of the joint Other perforations; size and location Ordinate dimensioning starting from the left hand side of the beam (all distances measured from the left hand side end of the beam) www.peikko.com 17

DELTABEAM HOLES JOINT DETAIL 16 NOTE!! Peikko Finland Oy reads uniformly distributed loads and spans of slabs from plane drawings Concentrated load Pkg=101 kn, Pqk=45,5 kn Elimination of ledge Formwork sheet Elevation of ledge 2800 1000 FILLED IN BY DELTABEAM: FILLED IN BY STRUCTURAL ENGINEER: FIRE CLASS RATING CONCENTRATED LOADS YES NO R60 X SITE MODEL SITE TYPE D26-400 D101 PREFERENCE DRAWING ADDITIONAL LINE LOAD CODE PCS 01.01.2007 1 DATE DESIGNER ADDITIONAL LINE LOAD PROJECT NO. EDGE JOINT DETAIL 13 245 400 660 5 195 3600 JOINT DETAIL 12 4560 700 7 110 400 Ø50 750 UPPER FLANGE d1= LOWER FLANGE d2= PRECAMBERING f= 60 265 50 400 660 18 265

Peikko Group www.peikko.com