Long Carbon Europe Sections and Merchant Bars. Slim Floor. An innovative concept for floors
|
|
|
- Rose Underwood
- 9 years ago
- Views:
Transcription
1 Long Carbon Europe Sections and Merchant Bars Slim Floor An innovative concept for floors
2 Fire resistant Integrated Flexible Architectes Claude Vasconi et Jean Petit - Chambre de Commerce Luxembourg
3 Contents 1. Priority to architectural expression 3 2. The ten advantages of Slim Floor 5 3. Asymmetrical girders - an intelligent solution 9 4. Erection Technical advantages Slim Floor: a sustainable development solution Pre-design tables 23 Technical assistance & Finishing 32 Your Partners 33 1
4
5 1. Priority to ARCHITECTURAL EXPRESSION 3
6 1. Priority to architectural expression IFB beam combined with Cofradal 200: the ideal solution COFRADAL200 Span COFRADAL200 Span Developed and offered by the ArcelorMittal group, the Slim Floor system is a fast, innovative and economical solution which marries prefabricated concrete slabs with built-in steel beams The secret of the design is a special kind of girder with a lower flange which is wider than the upper flange. This arrangement makes it possible to fit the floor slabs directly onto the lower flange plate of the beam, so that the two constituents thus make up the floor. Created to eliminate beam downstands at the level of the floor slabs, this reliable and economic prefabricated component unit gives the architect new scope for imagination and guaranteed economy for working spans of up to 8 metres. The reduced height of the slabs and the advantage of a considerable degree of fire resistance make for maximum freedom in creativity. A good alternative to the concrete slab would be the use of a floor on a Cofradal 200 steel tray IFB beam perfectly incorporated into the concrete floor IFB beam and Cofradal flooring system Car park made of IFB beams (Nantes, France)
7 2. THE TEN ADVANTAGES Of SLIM FLOOR Michel Denancé 5
8 2. The ten advantages of Slim Floor Successfully used for twenty years in Scandinavia, the Slim Floor process optimises the effective volume of the building and offers a number of advantages Floor thickness reduction This design gives a total flooring thickness reduction of between 25 and 40 centimetres according to the structure. Depending on the limitations of the project, this means that the room can be higher, extra floors can be added or the total height of the building can be reduced, which is often required by town planning requirements (e.g. very tall building classification). This degree of flexibility as regards height allows great freedom in the design of the façade and the roofing and savings can be made. 2. Constructing floors of variable thicknesses Should the span of the floor on either side of the supporting steel beam be important, up to 10 centimetres of difference in floor thickness could result. In situations like this, the Slim Floor beam provides a practical and elegant solution for dealing with the interface between the 2 floors Incorporating under-floor technical equipment The integrated beams make it easier to build in under-floor technical equipment (airconditioning, piping, electrical and ICT networks, etc), and simplify the fitting of false ceilings. The under-surfaces of the prefabricated slabs may also be left exposed on the soffit as long as some prefabrication precautions are taken and certain handling techniques are used. 4. Freeing-up working space The structural characteristics of the components, with up to 8 metres of bearing length for the steel beams and up to 10 or 12 metres for the slabs, means that open working spaces can be created, with a reduced number of intermediate columns. The spaces can be organised according to the aesthetic or operational requirements that may evolve over time. 5. Creating vertical movement space l Openings can be designed at the outset in the prefabricated floors depending on the possibilities offered by the slab manufacturers. l Where a slab is poured on site, provision can be made for pouring partitions or cavities to be made at a later date. 6. Built-in fire resistance The incorporation of the upper flange plates and cores of the beams in the thickness of the concrete slabs provides structural protection which meets most regulatory requirements, so that no fire protection is required (see section 5) Reduced floor thickness (Clinique d Eich, Luxembourg) Built-in under-floor technical equipment (Petrusse Building, Luxembourg) Prefabricated components being easily assembled Section through a Cofradal 200 floor Application of area of the IFB system
9 2. The ten advantages of Slim Floor Competitive pricing The amount of steel per square metre of floor is relatively low (generally from 15 to 25 kg/m 2 for beam spans from 5 to 7.5 meters). Prefabricated slabs are easily available on the market at competitive prices. The marriage of these two items results in very competitive prices throughout the whole span range covered by the system. 8. Easy to build The fast and simple assembly of the prefabricated components is almost entirely unaffected by atmospheric conditions. This makes it easier to meet site deadlines and to reduce construction costs to a minimum. 9. Environmentallysensitive construction The metal structure is 100% recyclable and reduces the number of transportation trips to the site and building site nuisance. 10. Lighter structures Bearing distance of the concrete [m] Combination of standard span Span combination for adaptation Normal span limits of prefabricated slabs Distortion and frequency limits Bearing distance of the steel [m] The steel structure is composed of elements which are all lighter than structural elements of concrete. If a floor type Cofradal 200 is used, the actual weight of the floor is decreased to 200kg/m 2. 7
10
11 3. ASYMMETRICAL GIRDERS - AN INTELLIGENT SOLUTION 3.1 Different slim-floor beam models Column-beam connection Beam-slab connection 12 9
12 3.1 Different Slim Floor beam models 3. Asymmetrical girders - an intelligent solution IFBs (Integrated Floor Beams) and SFBs (Slim Floor Beams) are re constituted from hot-rolled profiles and welded steel plates. They feature a lower flange plate (between 28 and 51 centimetres wide) which acts as a support for the floor slab These beams are available with spans of 5 to 8 metres and for effective heights of 14 to 30 centimetres. They can be cambered to offset the permanent load deflection. They may be designed as composite beams by welding shear studs onto the upper flange. This solution takes advantage of the participation of the extra concrete poured onto the slabs and increases the rigidity and robustness of the system. filler concrete floating screed/concrete poured in situ reinforced concrete poured in situ Where a rectangular frame is used, the span of the beams generally coincides with the smallest direction. IFB edge beam anchoring rods cellular slab anchor bars cellular slab The edge beams may be partly or completely integrated into the floor (picture 3.1.2). This will require several anchoring rods being provided and temporary propping during erection to avoid torsion. A more economical solution is the use of conventional beams with under the slab (picture 3.1.3) shear stud downstand beam tie bars Section through an IFB girder Built-in edge beam Downstand edge beam Cambered IFB and sloping beam, Nantes car park (France) IFB type A and B and SFB With steel plates, it is possible to make 2x IFB type A or 2x IFB type B or 1x SFB.
13 There are three types of asymmetrical girders (see the facing section): y z 2 z1 tp tf h eff = h/2 r b bp t IFB type A IFB TYPE A: A lower flange plate welded onto a half HE or IPE. For example, the upper T may be made from an IPE 500 or 600 cut in two, that is, a beam height of 250 or 300 millimetres. The bp figure must be at least equal to b+200 mm to guarantee minimum support on both sides of the T of 70 mm for the slabs. In fact, the support width must be determined in accordance with the specific requirements of the slab manufacturer. bp IFB TYPE B: y tp h eff r t z 2 h/2 z IFB type B A cut HE and a welded upper flange plate. These are suitable for small spans, since the maximum height of the web, obtained by cutting an HP or HD 400 in two, is about 200 millimetres. tf b SFB: y z2 tf r b tw heff SFB A plate is welded under an HE or an IPE. The SFB manufacturing cost is lower than for an IFB. This solution is appropriate for small-scale standard projects where materials are immediately available. z1 tp bp IFB type A IFB type B x 2x SFB 11
14 3.2 Columnbeam connection 3.3 Beam-slab connection The beams are bolted on steel H columns in the conventional manner, either by endplates, or by cleats, directly supported by columns or walls. Quick erect systems may also be used. By means of cut-outs in the end plates the beams are fitted directly onto threaded rods passing through the columns The slabs are placed on the lower flange of the beams and the assembly is made solid with filler concrete and tie bars. In order to increase the strength of the floor, the slab elements being faced are to connect to each other by reinforcement which cross or overpass the beams in the direction of the slabs. The bars are anchored in the joints or in the open cells of the slab elements. A concrete screed of a minimum of 5 centimetres is recommended to increase the rigidity and strength of the system. This is required to transmit horizontal forces by diaphragm effect and to increase fire-resistance of the floor. Slab elements are available with a length from 6 to 12 metres. An ideal grid leads to similar slab and beam heights. Prefabricated elements type Cofradal 200 may also be used Screed Starter bar Filler Concrete Prefabricated slab Steel plate Column-beam connection Flooring before concrete-work, Nantes car park Section of a slab floor in a type A IFB
15 4. ErecTION Michel Denancé 13
16 4. Erection The flooring is erected floor by floor to facilitate slab handling and the concrete pouring. The columns, often continuous through two or three floors, are stabilised with temporary or permanent bracing during erection. In most cases these are bolted onto the columns. The steel beams are fixed to the columns and the slabs are installed. The edge beams and those under asymmetrical loading are propped to avoid torsional effects. After the pouring and the hardening of the concrete the propping can be removed. Usually the structures are simple, isostatic and braced by Saint-Andrew s crosses or reinforced concrete cores (staircases, etc). To increase the strength of the system the connection of the beams to each other using devices which will resist accidental traction effects is recommended (shocks, etc., see EN ). This connection can be achieved using metal parts or frames (H or T) reduced in height embedded in the thickness of the floor. The advantage of this solution is that it provides an effective connection during assembly and reduces the number of temporary struts Temporary Propping Underside of a finished floor
17 5. TECHNICAL ADVANTAGES 5.1 Fire protection Protection against corrosion Heat and sound insulation Expansion joints in the flooring Beam spacing 17 15
18 5.1 Fire protection 5.2 Protection against corrosion Ensuring the fire resistance of the beams is easy, since only the lower flange is directly exposed to fire. 60-minute resistance can easily be reached, without any protection of the lower flange, with additionnal reinforcement in the beam chambers. More than 60 minutes fire resistance can be ensured by cladding, spayed protection or intumescent paint. The fire resistance of the overall system depends on the fire resistance of the slabs (which can be delivered up to R120) and on their capacity to adapt to the beam deformation. Overall resistance is increased by longitudinal reinforcement supported by shear studs in the beam chambers, by reinforcement between the slabs and by a reinforced screed. The use of Cofradal 200 allows fire resistance up to 120 minutes. Normally the lower flange of the beams is protected by SA 2.5 shot blasting and the application of a conventional paint. Surfaces embedded in the concrete do not need treatment. Generally it is not necessary to treat steel surfaces if they are inside buildings Cofradal 200 Section A-A Tying reinforcement Screed Filler Concrete Shear stud Prefabricated slab Reinforcing bars
19 5.3 Heat and sound insulation 5.4 Expansion joints in the flooring 5.5 Beam spacing Thanks to the volume of air they contain, cellular slabs provide better heat insulation than solid concrete slabs of the same thickness. The effect of the beams is negligible. The beams don t affect noticeably the heat and sound insulation characteristics of the cellular slabs. The light Cofradal 200 flooring system meets current standards without an additional insulating layer. l Expansion joint in beam direction: This is realised by splitting the loadbearing beam in 2 edge beams one symmetrical to the other. The expansion joint is made in the concrete screed by using an elastic sealing tape according to the standard rules for concrete floors. l Expansion joint in slab direction: A regular beam spacing is recommended to provide symmetrical loaded beams which are not subject to torsion. In the case of unequal concrete spans the beam or the whole floor is propped to avoid torsion. Differences in floor height can be adjusted by concreting a support for the thinner floor or by steel shims on the lower flange. An expansion joint may be made between two cellular slabs. Usually two sealing tapes are used to seal the joint COMPRESSION SCREED Variable height, < 15cm THIN SLAB THICK SLAB 5cm From 20 to 25cm SIDE ANGLE-IRON PRE-CONCRETED SUPPORT Filler concrete Cofradal IFB Integrated fire protection Column-beam connection Slab Cofradal Adjustment of the height difference of the floors 17
20
21 6. SLIM FLOOR: A SOLUTION FOR SUSTAINABLE DEVELOPMENT Michel Denancé 19
22 6. Slim floor: a solution for sustainable development The ArcelorMittal Group s environmental policy aims at sustainable development and the establishment of a long-term balance between the environment, social well-being and the economy. The long product mills of ArcelorMittal operate according to the criteria of the environmental management system as defined in the standard EN ISO 14001:1996. Most of ArcelorMittal s long product mills use the electric arch process, the starting material for which is 100% recycled scrap. This new steel production technology has made it possible to make a considerable reduction in emissions and primary energy consumption. By the use of the Slim Floor process it is possible to: l reduce the quantity of construction materials by using high resistance steels, Michel Denancé Michel Denancé l reduce the number of transportation trips because the structures are lighter, and thus reduce building site nuisance, l speed up building work through prefabrication, l meet environmental requirements by 100% recycled and 90% recyclable products.
23 Cité Internationale, Lyon, France Michel Denancé 21
24
25 7. Pre-design tables 7.1 IFB - Pre-design tables SFB - Pre-design tables 28 Architectes Claude Vasconi et Jean Petit - Chambre de Commerce Luxembourg 23
26 IFB Pre-design Tables - type IFB Design parameters Validity criteria L span of the IFB in meters G Dead Load in kn/m 2 P Live Load in kn/m 2 q d design load in kn/m q d = 1.35 * G i * P i l Steel Grade S355 l Simple supported beam l Symmetrically loaded Beam l Support length of the hollow core slabs = 70 mm l Load ratio G/P 60/40 l Beam weight included in Dead Load G i l Deflection under Live Load P L / 300 l Transverse deflection of the bottom flange 1,50 mm l Elastic-plastic design l Ideal elastic-plastic material behaviour l Global partial safety factor γ m0 = 1,00 Application example prescribed grid: 6,5 m x 10,0 m live load P: 5,0 kn/m 2 dead load G: 1,2 kn/m 2 slab thickness: approximately 26cm users choice IFB beam span: 6,5 m slab span: 10,0 m (= beam distance) depth of the HC slab: 26,5 cm (G 0 = 3,8 kn/m 2 ) calculated line load from G: line load from P: design load q d : g = 10,0 * (3,8 + 1,2) = 50 kn/m p = 10,0 * 5,0 = 50 kn/m q d = 1,35 * ,5 * 50 = 142,5 kn/m derived from the design table IFB-Slab < 300 mm: 1/2 HEA x20 (g = 161,6 kg/m) N.B.: Please observe the minimum tonnage required for section delivery! (The sections retained for diagram drawing are printed in bold characters!)
27 Section Plate Type G H h b t w t f r A I y W y y 1 y 2 B x t kg/m mm mm mm mm mm mm cm 2 cm 4 cm 3 cm cm ½ IPE x 10 A 63,0 200,0 400,0 180,0 8,6 13,5 21,0 80, ,9 12,1 ½ IPE O x 12 A 74,6 202,0 404,0 182,0 9,7 15,5 21,0 95, ,8 12,6 ½ IPE x 12 A 75,5 225,0 450,0 190,0 9,4 14,6 21,0 96, ,8 13,9 ½ IPE O x 12 A 84,0 228,0 456,0 192,0 11,0 17,6 21,0 107, ,5 13,5 ½ IPE x 12 A 83,2 250,0 500,0 200,0 10,2 16,0 21,0 106, ,3 14,9 ½ IPE O x 15 A 102,1 253,0 506,0 202,0 12,0 19,0 21,0 130, ,2 15,6 ½ IPE x 15 A 100,9 275,0 550,0 210,0 11,1 17,2 24,0 128, ,9 17,1 ½ IPE O x 15 A 110,7 278,0 556,0 212,0 12,7 20,2 24,0 141, ,7 16,6 ½ IPE x 15 A 110,7 300,0 600,0 220,0 12,0 19,0 24,0 141, ,6 17,9 ½ IPE O x 15 A 128,0 305,0 610,0 224,0 15,0 24,0 24,0 163, ,9 17,1 ½ IPE O x 20 A 144,8 305,0 610,0 224,0 15,0 24,0 24,0 184, ,7 18,8 ½ HE 220 M 430 x 15 A 109,3 120,0 240,0 226,0 15,5 26,0 18,0 139, ,2 7,3 ½ HE 240 M 450 x 20 A 149,0 135,0 270,0 248,0 18,0 32,0 21,0 189, ,1 8,4 ½ HE 260 B 460 x 12 A 89,8 130,0 260,0 260,0 10,0 17,5 24,0 114, ,5 7,7 ½ HE 260 M 470 x 20 A 160,0 145,0 290,0 268,0 18,0 32,5 24,0 203, ,7 8,8 ½ HE 280 M 500 x 20 A 172,8 155,0 310,0 288,0 18,5 33,0 24,0 220, ,3 9,2 ½ HE 280 M 500 x 25 A 192,4 155,0 310,0 288,0 18,5 33,0 24,0 245, ,9 10,1 ½ HE 300 B 500 x 15 A 117,4 150,0 300,0 300,0 11,0 19,0 27,0 149, ,4 9,1 ½ HE 300 M 500 x 25 A 217,1 170,0 340,0 310,0 21,0 39,0 27,0 276, ,3 10,2 ½ HE 320 B 500 x 15 A 122,2 160,0 320,0 300,0 11,5 20,5 27,0 155, ,0 9,5 ½ HE 320 M 500 x 25 A 220,6 179,5 359,0 309,0 21,0 40,0 27,0 281, ,8 10,6 ½ HE 320 M 500 x 30 A 240,2 179,5 359,0 309,0 21,0 40,0 27,0 306, ,5 11,4 ½ HE 340 B 500 x 15 A 126,0 170,0 340,0 300,0 12,0 21,5 27,0 160, ,7 9,8 ½ HE 340 M 500 x 25 A 222,1 188,5 377,0 309,0 21,0 40,0 27,0 282, ,3 11,1 ½ HE 340 M 500 x 30 A 241,7 188,5 377,0 309,0 21,0 40,0 27,0 307, ,9 11,9 ½ HE 360 B 500 x 15 A 129,8 180,0 360,0 300,0 12,5 22,5 27,0 165, ,3 10,2 ½ HE 360 M 500 x 25 A 223,3 197,5 395,0 308,0 21,0 40,0 27,0 284, ,7 11,5 ½ HE 360 M 500 x 30 A 242,9 197,5 395,0 308,0 21,0 40,0 27,0 309, ,3 12,4 ½ HE 400 B 500 x 20 A 156,1 200,0 400,0 300,0 13,5 24,0 27,0 198, ,6 12,4 ½ HE 400 M 500 x 25 A 226,0 216,0 432,0 307,0 21,0 40,0 27,0 287, ,6 12,5 ½ HE 400 M 500 x 30 A 245,6 216,0 432,0 307,0 21,0 40,0 27,0 312, ,2 13,4 ½ HE 450 B 500 x 20 A 164,1 225,0 450,0 300,0 14,0 26,0 27,0 209, ,0 13,5 ½ HE 450 M 500 x 25 A 229,8 239,0 478,0 307,0 21,0 40,0 27,0 292, ,8 13,6 ½ HE 450 M 500 x 30 A 249,4 239,0 478,0 307,0 21,0 40,0 27,0 317, ,3 14,6 ½ HE 500 A 500 x 20 A 156,0 245,0 490,0 300,0 12,0 23,0 27,0 198, ,4 15,1 ½ HE 500 B 500 x 20 A 172,2 250,0 500,0 300,0 14,5 28,0 27,0 219, ,5 14,5 ½ HE 500 M 500 x 25 A 233,3 262,0 524,0 306,0 21,0 40,0 27,0 297, ,9 14,8 ½ HE 500 M 500 x 30 A 252,9 262,0 524,0 306,0 21,0 40,0 27,0 322, ,3 15,9 ½ HE 550 A 500 x 20 A 161,6 270,0 540,0 300,0 12,5 24,0 27,0 205, ,7 16,3 ½ HE 550 B 500 x 20 A 178,2 275,0 550,0 300,0 15,0 29,0 27,0 227, ,9 15,6 ½ HE 550 B 500 x 25 A 197,9 275,0 550,0 300,0 15,0 29,0 27,0 252, ,0 17,0 ½ HE 550 M 500 x 25 A 237,2 286,0 572,0 306,0 21,0 40,0 27,0 302, ,1 16,0 ½ HE 550 M 500 x 30 A 256,9 286,0 572,0 306,0 21,0 40,0 27,0 327, ,4 17,2 ½ HE 550 M 500 x 35 A 276,5 286,0 572,0 306,0 21,0 40,0 27,0 352, ,9 18,2 ½ HE 600 A 500 x 20 A 167,4 295,0 590,0 300,0 13,0 25,0 27,0 213, ,1 17,4 ½ HE 600 B 500 x 20 A 184,5 300,0 600,0 300,0 15,5 30,0 27,0 235, ,2 16,8 ½ HE 600 B 500 x 25 A 204,1 300,0 600,0 300,0 15,5 30,0 27,0 260, ,3 18,2 ½ HE 600 M 500 x 30 A 260,5 310,0 620,0 305,0 21,0 40,0 27,0 331, ,5 18,5 ½ HE 600 M 500 x 35 A 280,1 310,0 620,0 305,0 21,0 40,0 27,0 356, ,9 19,6 ½ HE 650 A 500 x 20 A 173,3 320,0 640,0 300,0 13,5 26,0 27,0 220, ,4 18,6 ½ HE 650 B 500 x 25 A 210,5 325,0 650,0 300,0 16,0 31,0 27,0 268, ,6 19,4 ½ HE 650 M 500 x 25 A 244,8 334,0 668,0 305,0 21,0 40,0 27,0 311, ,5 18,4 ½ HE 650 M 500 x 30 A 264,4 334,0 668,0 305,0 21,0 40,0 27,0 336, ,7 19,7 ½ HE 650 M 500 x 35 A 284,1 334,0 668,0 305,0 21,0 40,0 27,0 361, ,0 20,9 ½ HE 280 A 80 x 40 B 63,3 162,0 270,0 280,0 8,0 13,0 24,0 80, ,4 10,1 ½ HE 300 A 100 x 30 B 67,7 161,0 290,0 300,0 8,5 14,0 27,0 86, ,0 10,5 ½ HP 360 x x 20 B 81,2 180,3 346,4 371,0 12,8 12,9 15,2 103, ,2 11,1 ½ HP 360 x x 30 B 94,6 190,3 346,4 371,0 12,8 12,9 15,2 120, ,8 10,5 ½ HP 360 x x 20 B 93,0 180,3 352,0 373,8 15,6 15,7 15,2 118, ,7 11,9 ½ HP 360 x x 30 B 106,4 190,3 352,0 373,8 15,6 15,7 15,2 135, ,3 11,3 ½ HP 360 x x 30 B 116,2 190,3 356,4 376,0 17,8 17,9 15,2 148, ,0 11,8 ½ HP 360 x x 40 B 129,5 200,3 356,4 376,0 17,8 17,9 15,2 165, ,3 11,6 ½ HP 400 x x 20 B 91,1 180,0 348, ,0 14,0 15,0 116, ,2 11,2 ½ HP 400 x x 30 B 106,0 190,0 348,0 390,0 14,0 14,0 15,0 135, ,8 10,6 ½ HP 400 x x 30 B 115,0 190,0 352,0 392,0 16,0 16,0 15,0 146, ,5 11,1 ½ HP 400 x x 40 B 129,9 200,0 352,0 392,0 16,0 16,0 15,0 165, ,8 10,8 ½ HP 400 x x 30 B 123,6 190,0 356,0 394,0 18,0 18,0 15,0 157, ,2 11,6 ½ HP 400 x x 40 B 138,6 200,0 356,0 394,0 18,0 18,0 15,0 176, ,5 11,3 ½ HP 400 x x 30 B 132,7 190,0 360,0 396,0 20,0 20,0 15,0 169, ,9 12,1 ½ HP 400 x x 40 B 147,6 200,0 360,0 396,0 20,0 20,0 15,0 188, ,2 11,8 ½ HP 400 x x 30 B 142,1 190,0 364,0 398,0 22,0 22,0 15,0 181, ,8 12,4 ½ HP 400 x x 40 B 157,0 200,0 364,0 398,0 22,0 22,0 15,0 200, ,0 12,2 25
28 IFB Pre-design Tables - type IFB IFB - Slab thickness < 160 mm 250 z ½ HE 280 M x 25 z ½ HE 280 M x 20 z ½ HE 260 M x 20 z ½ HE 240 M x 20 z ½ HE 220 M x 15 z ½ HE 280 A + 80 x 40 Design Load q d [kn/m] Beam Span L [m] IFB - Slab thickness < 200 mm Design Load q d [kn/m] z ½ HE 360 M x 25 z ½ HE 300 M x 25 z ½ HP 400 x x 40 z ½ HP 400 x x 40 z ½ HP 400 x x 40 z ½ HP 360 x x 30 z ½ HP 360 x x 30 z ½ IPE x Beam Span L [m]
29 IFB - Slab thickness < 260 mm Design Load q d [kn/m] z ½ HE 450 M x 30 z ½ HE 450 M x 25 z ½ HE 400 M x 25 z ½ HE 500 A x 20 z ½ IPE O x 15 z ½ IPE x 12 z ½ IPE x Beam Span L [m] IFB - Slab thickness < 300 mm Design Load q d [kn/m] z ½ HE 550 M x 35 z ½ HE 500 M x 30 z ½ HE 600 B x 25 z ½ HE 550 B x 25 z ½ HE 550 A x 20 z ½ IPE x Beam Span L [m] IFB - Slab thickness < 340 mm 700 Design Load q d [kn/m] z ½ HE 650 M x 35 z ½ HE 600 M x 35 z ½ HE 600 M x 30 z ½ HE 650 B x 25 z ½ IPE O x 20 z ½ IPE O 600 x 430 x Beam Span L [m] 27
30 SFB Pre-design Tables - type SFB Design parameters : Validity criteria : L Span of the SFB in meters G Dead Load in kn/m 2 P Live Load in kn/m 2 q d Design load in kn/m q d = 1.35 * G i * P i l Steel Grade S355 l Simple supported beam l Symmetrically loaded Beam l Support length of the Cofradal 200 prefabricated slabs = 50 mm l Load ratio G/P 60/40 l Beam weight included in Dead Load G i l Deflection under Live Load P L / 300 l Transverse deflection of the bottom flange 1,50 mm l Elastic-plastic design l Ideal elastic-plastic material behaviour l Global partial safety factor γ m0 = 1.00 Application example : Prescribed Grid: 7.0 m x 7.0 m Live load P: 2.5 kn/m 2 Dead load G: 1.0 kn/m 2 Slab thickness: approximately 20 cm Users choice SFB beam span: 7.0 m Prefabricated slab span: 7.0 m (= beam distance) Depth of the Cofradal 200 prefabricated slabs: 20.0 cm (G 0 = 2.0 kn/m 2 ) Calculated Line load from G: Line load from P: Design load q d : g = 7.0 * ( ) = 21.0 kn/m p = 7.0 * 2.5 = 17.5 kn/m q d = 1.35 * * 17.5 = 54.6 kn/m Derived from the design table SFB-Slab < 200 mm: HEM x 15 (g = 165,5 kg/m) N.B.: Please observe the minimum tonnage required for section delivery! (The sections retained for diagram drawing are printed in bold characters!)
31 Section Plate G h b t w t f r A I y W y y 1 y 2 B x t kg/m mm mm mm mm mm cm 2 cm 4 cm 3 cm cm HEB x 10 60,4 140,0 140,0 7,0 12,0 12,0 77, ,7 10,3 HEM x 10 90,7 160,0 146,0 13,0 22,0 12,0 115, ,4 10,6 HEM x ,5 160,0 146,0 13,0 22,0 12,0 133, ,0 11,5 HEM x ,2 160,0 146,0 13,0 22,0 12,0 150, ,8 12,2 HEB x 10 70,9 160,0 160,0 8,0 13,0 15,0 90, ,6 11,4 HEM x ,3 180,0 166,0 14,0 23,0 15,0 134, ,4 11,6 HEM x ,8 180,0 166,0 14,0 23,0 15,0 152, ,0 12,5 HEM x ,3 180,0 166,0 14,0 23,0 15,0 171, ,7 13,3 HEM x ,8 180,0 166,0 14,0 23,0 15,0 189, ,5 14,0 HEB x 10 81,1 180,0 180,0 8,5 14,0 15,0 103, ,5 12,5 HEB x 15 96,0 180,0 180,0 8,5 14,0 15,0 122, ,0 13,5 HEM x ,6 200,0 186,0 14,5 24,0 15,0 152, ,3 12,7 HEM x ,9 200,0 186,0 14,5 24,0 15,0 171, ,8 13,7 HEM x ,2 200,0 186,0 14,5 24,0 15,0 191, ,5 14,5 HEM x ,5 200,0 186,0 14,5 24,0 15,0 210, ,3 15,2 HEB x 10 92,7 200,0 200,0 9,0 15,0 18,0 118, ,4 13,6 HEB x ,4 200,0 200,0 9,0 15,0 18,0 138, ,8 14,7 HEM x ,3 220,0 206,0 15,0 25,0 18,0 172, ,3 13,7 HEM x ,3 220,0 206,0 15,0 25,0 18,0 192, ,8 14,7 HEM x ,4 220,0 206,0 15,0 25,0 18,0 213, ,4 15,6 HEM x ,5 220,0 206,0 15,0 25,0 18,0 233, ,1 16,4 HEM x ,6 220,0 206,0 15,0 25,0 18,0 254, ,0 17,0 HEB x ,4 220,0 220,0 9,5 16,0 18,0 133, ,4 14,6 HEB x ,9 220,0 220,0 9,5 16,0 18,0 154, ,7 15,8 HEB x ,4 220,0 220,0 9,5 16,0 18,0 175, ,2 16,8 HEM x ,0 240,0 226,0 15,5 26,0 18,0 192, ,2 14,8 HEM x ,9 240,0 226,0 15,5 26,0 18,0 213, ,7 15,8 HEM x ,8 240,0 226,0 15,5 26,0 18,0 235, ,3 16,7 HEM x ,7 240,0 226,0 15,5 26,0 18,0 256, ,0 17,5 HEM x ,5 240,0 226,0 15,5 26,0 18,0 278, ,7 18,3 HEB x ,8 240,0 240,0 10,0 17,0 21,0 150, ,3 15,7 HEB x ,0 240,0 240,0 10,0 17,0 21,0 172, ,6 16,9 HEB x ,3 240,0 240,0 10,0 17,0 21,0 194, ,1 17,9 HEM x ,0 270,0 248,0 18,0 32,0 21,0 244, ,9 16,1 HEM x ,7 270,0 248,0 18,0 32,0 21,0 267, ,4 17,1 HEM x ,3 270,0 248,0 18,0 32,0 21,0 289, ,0 18,0 HEM x ,0 270,0 248,0 18,0 32,0 21,0 312, ,7 18,8 HEM x ,7 270,0 248,0 18,0 32,0 21,0 334, ,4 19,6 HEM x ,3 270,0 248,0 18,0 32,0 21,0 357, ,3 20,2 HEM x ,0 270,0 248,0 18,0 32,0 21,0 379, ,2 20,8 HEB x ,1 260,0 260,0 10,0 17,5 24,0 164, ,2 16,8 HEB x ,1 260,0 260,0 10,0 17,5 24,0 187, ,4 18,1 HEB x ,2 260,0 260,0 10,0 17,5 24,0 210, ,9 19,1 HEM x ,3 290,0 268,0 18,0 32,5 24,0 266, ,9 17,1 HEM x ,7 290,0 268,0 18,0 32,5 24,0 290, ,3 18,2 HEM x ,2 290,0 268,0 18,0 32,5 24,0 313, ,9 19,1 HEM x ,6 290,0 268,0 18,0 32,5 24,0 337, ,5 20,0 HEM x ,1 290,0 268,0 18,0 32,5 24,0 360, ,2 20,8 HEM x ,5 290,0 268,0 18,0 32,5 24,0 384, ,0 21,5 HEM x ,0 290,0 268,0 18,0 32,5 24,0 407, ,9 22,1 HEB x ,8 280,0 280,0 10,5 18,0 24,0 179, ,1 17,9 HEB x ,7 280,0 280,0 10,5 18,0 24,0 203, ,3 19,2 HEB x ,5 280,0 280,0 10,5 18,0 24,0 227, ,7 20,3 HEM x ,8 310,0 288,0 18,5 33,0 24,0 290, ,7 18,3 HEM x ,4 310,0 288,0 18,5 33,0 24,0 315, ,1 19,4 HEM x ,1 310,0 288,0 18,5 33,0 24,0 340, ,6 20,4 HEM x ,7 310,0 288,0 18,5 33,0 24,0 365, ,3 21,2 HEM x ,3 310,0 288,0 18,5 33,0 24,0 390, ,0 22,0 HEM x ,9 310,0 288,0 18,5 33,0 24,0 415, ,7 22,8 HEM x ,6 310,0 288,0 18,5 33,0 24,0 440, ,5 23,5 HEB x ,3 300,0 300,0 11,0 19,0 27,0 199, ,1 18,9 HEB x ,9 300,0 300,0 11,0 19,0 27,0 224, ,2 20,3 HEB x ,5 300,0 300,0 11,0 19,0 27,0 249, ,6 21,4 HEB x ,2 300,0 300,0 11,0 19,0 27,0 274, ,1 22,4 HEM x ,2 340,0 310,0 21,0 39,0 27,0 353, ,5 19,5 HEM x ,8 340,0 310,0 21,0 39,0 27,0 378, ,0 20,5 HEM x ,4 340,0 310,0 21,0 39,0 27,0 403, ,5 21,5 HEM x ,1 340,0 310,0 21,0 39,0 27,0 428, ,2 22,3 HEM x ,7 340,0 310,0 21,0 39,0 27,0 453, ,9 23,1 HEM x ,3 340,0 310,0 21,0 39,0 27,0 478, ,6 23,9 HEM x ,9 340,0 310,0 21,0 39,0 27,0 503, ,4 24,6 HEB x ,9 320,0 300,0 11,5 20,5 27,0 211, ,1 19,9 HEB x ,5 320,0 300,0 11,5 20,5 27,0 236, ,2 21,3 HEB x ,1 320,0 300,0 11,5 20,5 27,0 261, ,5 22,5 HEB x ,7 320,0 300,0 11,5 20,5 27,0 286, ,0 23,5 29
32 SFB Pre-design Tables - type SFB SFB - Slab thickness < 160 mm z HEM x 15 z HEB x 10 z HEB x 10 Design Load q d [kn/m] Beam Span L [m] SFB - Slab thickness < 200 mm Design Load q d [kn/m] z HEM x 25 z HEM x 15 z HEM x 25 z HEM x 15 z HEB x 15 z HEB x Beam Span L [m]
33 SFB - Slab thickness < 260 mm Design Load q d [kn/m] z HEM x 30 z HEM x 15 z HEB x 20 z HEB x 15 z HEM x 15 z HEB x 15 z HEB x 10 z HEB x Beam Span L [m] SFB - Slab thickness < 300 mm Design Load q d [kn/m] z HEM x 40 z HEM x 25 z HEM x 35 z HEM x 25 z HEM x 15 z HEB x 25 z HEB x 15 z HEB x Beam Span L [m] SFB - Slab thickness < 340 mm Design Load q d [kn/m] z HEM x 40 z HEM x 20 z HEM x 40 z HEM x 30 z HEM x 20 z HEB x Beam Span L [m] 31
34 Technical assistance & Finishing Technical assistance We are happy to provide you with free technical advice to optimise the use of our products and solutions in your projects and to answer your questions about the use of sections and merchant bars. This technical advice covers the design of structural elements, construction details, surface protection, fire safety, metallurgy and welding. Our specialists are ready to support your initiatives anywhere in the world. To facilitate the design of your projects, we also offer software and technical documentation that you can consult or download from our website: Finishing As a complement to the technical capacities of our partners, we are equipped with high-performance finishing tools and offer a wide range of services, such as: l drilling l flame cutting l T cut-outs l notching l cambering l curving l straightening l cold sawing to exact length l welding and fitting of studs l shot and sand blasting l surface treatment Building & Construction Support At ArcelorMittal we also have a team of multi-product professionals specialising in the construction market: the Building and Construction Support (BCS) division. A complete range of products and solutions dedicated to construction in all its forms: structures, façades, roofing, etc. is available from the website
35 Your partners ArcelorMittal Commercial Sections 66, rue de Luxembourg L-4221 Esch-sur-Alzette Luxembourg Tel: Fax: We operate in more than 60 countries on all five continents. Please have a look at our website under About us to find our local agency in your country. Although every care has been taken during the production of this brochure, we regret that we cannot accept any liability in respect of any incorrect information it may contain or any damages which may arise through the misinterpretation of its contents.
36 ArcelorMittal Commercial Sections 66, rue de Luxembourg L-4221 Esch-sur-Alzette LUXEMBOURG Tel Fax Version
Contents. 01 Introduction 1. 02 Key Design Factors. 03 Floor Systems. 04 Special Floor Systems 27. 05 Beam Connections.
Best Practice in Steel Construction - Commercial Buildings Contents The Steel Construction Institute (SCI) develops and promotes the effective use of steel in construction. It is an independent, membership
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges
7.7 Truss bridges Fig. 7.21 some of the trusses that are used in steel bridges Truss Girders, lattice girders or open web girders are efficient and economical structural systems, since the members experience
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors
Best Practice in Steel Construction - Industrial Residential Buildings Contents The Steel Construction Institute (SCI) develops and promotes the effective use of steel in construction. It is an independent,
DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version
ANLAGENTECHNIK HS-Steel-Classic Curing chambers for the concrete block industry in a proven steel version + special galvanising + simple assembly due to snap-in connections and building kit system We build
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION
CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything
STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 2: Concept Design
STEEL BUILDINGS IN EUROPE Multi-Storey Steel Buildings Part 2: Concept Design. Multi-Storey Steel Buildings Part 2: Concept Design 2 - ii FOREWORD This publication is a second part of a design guide,
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
Eurocode 4: Design of composite steel and concrete structures
Eurocode 4: Design of composite steel and concrete structures Dr Stephen Hicks, Manager Structural Systems, Heavy Engineering Research Association, New Zealand Introduction BS EN 1994 (Eurocode 4) is the
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE
Multi-storey Precast Concrete Framed Structures Kim S. Elliott BTech, PhD, CEng, MICE Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE WI LEY Blackwell Contents Preface Notation Precast Concepts, History
Composite Construction with KÖCO- Stud Welding Technology IMPRESSIVE TECHNOLOGY 6/2005 1.1
Composite Construction with KÖCO- Stud Welding Technology IMPRESSIVE TECHNOLOGY 6/2005 1.1 Composite Construction with KÖCO Stud Welding Technology What is composite construction? An outstanding feature
8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS
8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS MARICA DELLA BELLA and DIEGO CIAN Precompressi Centro Nord S.p.A., Italy SUMMARY: Secondary roofing elements, complementary to the
The minimum reinforcement for the stem wall is the placement of:
PolySteel creates an ideal insulated stem wall for concrete slabs that can make this part of your project easier and faster, in addition to making your finished project more energy-efficient. Figures 3.20
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Conceptual design and design examples for multi-storey buildings
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Conceptual design and design examples for multi-storey buildings Dr.-Ing. Christian Müller Dipl.-Ing. Matthias Oppe RWTH Aachen Overview
Weight Measurement Technology
Kistler-Morse (KM) introduced bolt-on weight measuring systems three decades ago. These devices featured Walter Kistler s invention, the Microcell. Over the years, many improvements were made to the Microcell
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
Fire safety in timber buildings
Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Foreword. This manual provides technical information for designers and contractors to design and plan the construction operation.
Foreword Foreword This manual provides technical information for designers and contractors to design and plan the construction operation. The body of the manual is split into eight distinct sections: 1.
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia
DESIGN OF SLABS Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia Introduction Types of Slab Slabs are plate elements
Overhang Bracket Loading. Deck Issues: Design Perspective
Deck Issues: Design Perspective Overhang Bracket Loading Deck overhangs and screed rails are generally supported on cantilever brackets during the deck pour These brackets produce an overturning couple
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports. Report number C 1395-1E-RA-003 d.d. May 14, 2014 Fire-resistant barriers: background on requirements
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
Optimising plate girder design
Optimising plate girder design NSCC29 R. Abspoel 1 1 Division of structural engineering, Delft University of Technology, Delft, The Netherlands ABSTRACT: In the design of steel plate girders a high degree
Technical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
Structural fire design Eurocode 5-1.2 Timber structures
Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 1 Structural fire design Eurocode 5-1.2 Timber structures Jochen Fornather Austrian Standards Institute [email protected]
FORM DESIGN. easy to work with, and generally available.
Forms play a major role in concrete construction. They give the plastic concrete its shape and hold it until it hardens. Forms protect the concrete, assist in curing it, and support any reinforcing rods
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
APPENDIX H DESIGN CRITERIA FOR NCHRP 12-79 PROJECT NEW BRIDGE DESIGNS
APPENDIX H DESIGN CRITERIA FOR NCHRP 12-79 PROJECT NEW BRIDGE DESIGNS This appendix summarizes the criteria applied for the design of new hypothetical bridges considered in NCHRP 12-79 s Task 7 parametric
Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span
formwork formwork Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span has grown to become one of the major players in the scaffolding and
Light Steel Modular Construction
Technical Information Sheet ED014 Light Steel Modular Construction R M Lawson BSc PhD CEng MICE MIStructE MASCE ACGI This Information Sheet reviews the various forms of building modules constructed using
Technical Assignment 2 TABLE OF CONTENTS
2 TABLE OF CONTENTS Executive Summary...3 Introduction..5 Gravity Loads......6 Design Codes......7 Materials..8 Existing Structural System.. 10 Existing Floor System 15 Alternate Floor Framing Systems...17
ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
Steel Solutions for Green Building
Steel Solutions for Green Building Createsima transforming tomorrow Steel Solutions for Green Building As society makes determined moves towards sustainability, construction has a very important role to
C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction
C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,
Steel joists and joist girders are
THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
Chapter. Restoration of Damaged Structures
5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:
Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems
Design and Construction of Cantilevered Reinforced Concrete Structures
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
HOPLEYS OPENWEBSTEELJOISTS
Design Aid Manual Now also includes Letter of Certification & Bearer Span Table HOPLEYS OPENWEBSTEELJOISTS 2...has over 60 years experience and a respected reputation in Sheet Metal fabrication and associated
Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
Prestressed Concrete I-Beam and TxGirder Haunch Design Guide
Prestressed Concrete I-Beam and TxGirder Haunch Design Guide Components of the Haunch Camber: Camber is the upward deflection in the beam after release of the prestressing strands due to the eccentricity
Optimum proportions for the design of suspension bridge
Journal of Civil Engineering (IEB), 34 (1) (26) 1-14 Optimum proportions for the design of suspension bridge Tanvir Manzur and Alamgir Habib Department of Civil Engineering Bangladesh University of Engineering
Aluminium systems profile selection
Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP
COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP 30 x45 bay provides maximum tenant flexibility and increases leasing marketability By David E. Eckmann AIA, S.E. P.E. SURGING DEMANDS FOR RENTABLE OFFICE
Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width
Modern Applied Science; Vol. 9, No. 6; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education Numerical Analysis of the Moving Formwork Bracket Stress during Construction
Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections
Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built
Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa
Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard
Joist. Reinforcement. Draft 12/7/02
Joist Reinforcement Draft 12/7/02 1 JOIST REINFORCING The purpose of this CSD Design Aid is to provide procedures and suggested details for the reinforcement of open web steel joists. There are three basic
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
Page 1 of 18 28.4.2008 Sven Alexander Last revised 1.3.2010. SB-Produksjon STATICAL CALCULATIONS FOR BCC 250
Page 1 of 18 CONTENT PART 1 BASIC ASSUMPTIONS PAGE 1.1 General 1. Standards 1.3 Loads 1. Qualities PART ANCHORAGE OF THE UNITS.1 Beam unit equilibrium 3. Beam unit anchorage in front..1 Check of capacity..
Heat Treatment Process
Heat Treatment Process Holytown, Scotland UK Resistors - Insulation - Protection Chongqing, China C/C fixturing, rods & beams Insulation St-Marys, USA Gennevilliers, France Main production sites Industrial
Buildings Construction Procurement Strategy
Buildings Construction Procurement Strategy Graham Strickleton Site, Buildings and Power supplies Procurement Manager JOURNEE DEDIEE AUX INDUSTRIELS ET AUX MEMBRES DU RESEAU A.P.I Disclaimer: these slides
SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:
SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
Forensic engineering of a bored pile wall
NGM 2016 Reykjavik Proceedings of the 17 th Nordic Geotechnical Meeting Challenges in Nordic Geotechnic 25 th 28 th of May Forensic engineering of a bored pile wall Willem Robert de Bruin Geovita AS, Norway,
[TECHNICAL REPORT I:]
[Helios Plaza] Houston, Texas Structural Option Adviser: Dr. Linda Hanagan [TECHNICAL REPORT I:] Structural Concepts & Existing Conditions Table of Contents Executive Summary... 2 Introduction... 3 Structural
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
Scope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Project Report. Structural Investigations Hotel del Sol Yuma, Arizona
Project Report Structural Investigations Yuma, Arizona Prepared by: 2619 Spruce Street Boulder, CO 80302 303-444-3620 Prepared for: Principle Engineering Group, Inc. 833 East Plaza Circle, Suite 100 Yuma,
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
Expected Performance Rating System
Expected Performance Rating System In researching seismic rating systems to determine how to best classify the facilities within the Portland Public School system, we searched out what was used by other
FireWall. High performance fireresistant. FireWall. www.british-gypsum.com
FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations
The Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC 2015 - October 27, 2015 Session 26
2014 HDR Architecture, 2014 2014 HDR, HDR, Inc., all all rights reserved. Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC 2015 - October 27, 2015 Session 26 Brandon Chavel, PhD, P.E.,
OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.
OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different
How To Build A Gambrel Roof And A Gable End Roof
Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect
COMPOSITE SLABS AND BEAMS USING STEEL DECKING: BEST PRACTICE FOR DESIGN AND CONSTRUCTION
cyan plate magenta plate yellow plate black plate MCRMA Technical Paper No. 13 SCI Publication P300 CI/SfB REVISED EDITION Composite Slabs and Beams Using Steel Decking: Best Practice for Design and Construction
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Technical handbook Panel Anchoring System
1 Basic principles of sandwich panels 3 Design conditions 4 Basic placement of anchors and pins 9 Large elements (muliple rows) 10 Small elements (two rows) 10 Turned elements 10 Slender elements 10 Cantilevering