Temperature Controller (Heat Pumps)

Similar documents
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

OZW30. Central Unit SYNERGYR

Electronic Control Devices The European Product Catalogue 2007

RRV934. Multi-controller. Synco living

Electronic Control Devices The European Product Catalogue 2007

Adjustable room thermostat for heating only or cooling only systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Duct Humidity Transmitter

Flush-mounted room thermostats

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Digital input modules

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Drayton Digistat +2RF/+3RF

HERZ-Thermal Actuators

ABB i-bus KNX Fan Coil Controller FC/S 1.1

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Waveguide Access Point WGA631. Product Guide

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Impulse contacts are not suitable for use as status contacts.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

T0118 T2118 T3118. Instruction Manual

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

FX07 Field Controller

VAV compact controller KNX / PL-Link

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PCS0100en Persy Control Services B.V. Netherlands

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

T5000 T000 LCD Digital Fan Coil Thermostat

Room Temperature Sensors

Temperature & Humidity SMS Alert Controller

Digital display DA 48

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TX OPEN RS232/485 module

Controls for fan coil units and cassettes

Modular I/O System Analog and Digital Interface Modules

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Smile. The All-In-One Heating Controller

Model: DC-A2IO Advanced HVAC Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

STERILIZERS, LABORATORY DRYING OVENS

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

FX07 Field Controller

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Heating, air-conditioning, cooling

GSM HOME SECURITY SYSTEM

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

IntesisBox KNX Mitsubishi Heavy Industries AC

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

T-100-R Installation Guide

HCR3.2/.. Chipcard reader HOTEL SOLUTION

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Product and functional description

PXM20-E. Operator unit DESIGO PX

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

HVAC and Lighting Control Products for Open Building Automation Systems

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

VAV compact controller KNX / PL-Link

T7560A,B,C Digital Wall Module

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

OZS Web server. For LPB/BSB plants

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Multifunction devices

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Air damper actuators

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

Hand-held thermometer Model CTH7000

Mureva Assembly surface mounted wiring devices

Inwall Room Temperature Unit

Thyristor-controlled power supplies and battery chargers

HVAC Processes. Lecture 7

Electric Rotary Actuator - On/Off or programmable control actuator

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

J TB/TW Temperature limiter, temperature monitor

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Product and Application Description

HMI display Installation Guide

ABB i-bus KNX SA/S Switch Actuators Product Manual

Quick Connect. quick - simple - efficient.

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Safety technique. Emergency stop module BO 5988 safemaster

In addition to the equipment heat load the room / enclosure will also provide heat gains through the building structure and environment.

ECOCIAT. Domestic hot water heat recovery unit

Transcription:

3 346 Temperature Controller (Heat Pumps) RWD34 RWD44 For comfort control in HVAC & R systems Standalone electronic controller Programmable controller with preconfigured applications Two universal inputs for Ni 1000, Pt 1000 or active DC0 10V Four 2position (On/Off) outputs Suitable for 1, 2 and 3stage compressor Adjustable compressor delay times Entering or changing of parameters via push buttons or software tool PC connection for downloading canned applications via software tool DIN rail or panel mount Use The RWD34 and RWD44 controllers are intended for Heating, Ventilating, Airconditioning and Refrigeration systems including Heat Pumps. Control equipment Single, dual or triple compressor Heat Pumps Single, dual stage heating and cooling equipment Single, dual stage cooling equipment Single, dual stage heating equipment CE2N3346en 15.01.2003 Siemens Building Technologies HVAC Products

Functions summary Controller Standalone controller with four 2positon (On/Off) outputs Universal input X1 for the main temperature sensor. Universal input X2 for the following auxiliary functions. On/Off (Standby) Remote setpoint Alarm Filter alarm Setpoint compensation Sensor averaging Winter/Summer setpoint changeover Sensor select Digital input D1 for the following functions. Day/night changeover setpoint On/Off (Standby) Alarm Filter alarm Type summary Input Outputs Supply Voltage Type Analog Digital Digital 2 1 4 AC 230V RWD34 2 1 4 AC 24V RWD44 Accessories Name Protective single enclosure for wall mounting Protective multiple enclosure for wall mounting Time Clock Transformer (30VA) Type ARG62.21 ARG62.22 SEH62.1 SE62.1 & SE62.2 Equipment combinations The following units can be connected to controllers. Units Data sheet no. Sensors with Ni 1000 temperature sensing element 17... to 18 Sensors with Pt 1000 temperature sensing element 1846 Sensors with DC0 10V measuring signal 17 to 19 Room temperature sensor with setpoint adjuster QAA25 1721/1748 or QAA25/AP Remote setpoint adjuster, FZA21.11 & FZA61.11 19 Air damper actuators with 2position input 46 Valve actuators with 2position input 45 Other equipment with 2position input Examples: compressors, electric heaters, fans Other combinations with third party units are possible, provided input and output specifications match the controller. 2/13

Functions ain function Applications The RWD34 and RWD44 controllers perform both primary and auxiliary functions. The input X1 detects the actual temperature and compares it with the setpoints. Depending on the deviation, the controller acts with its outputs to achieve the desired setpoints. The controller has standard preconfigured applications. The respective application and setting parameters are entered via push buttons on the controller or a software tool. Refer to page 13 or the Installation & Commissioning guide for application numbers. The RWD34 and RWD44 controllers can be programmed as follows: 2stage heating and cooling Applications #10 #19 SD_H2 Q1 SD_H1 Q2 SD_C1 Q3 SD_C2 Q4 ON SP_H2 SP_H1 SP_C1 SP_C2 OFF Q 3346d01 SP_H Setpoint heating stage Q2 Heating stage 1 SP_C Setpoint cooling stage Q1 Heating stage 2 SD_ Switching differential Q3 Cooling stage 1 Q Load Q4 Cooling stage 2 3stage compressor with reversing valve in cooling demand Applications #20 #29 SD_H3 SD_H2 SD_H1 SD_C1 SD_C2 SD_C3 Q4 SP_H3 Q3 SP_H2 Q2 SP_H1 Q2 Q3 Q4 SP_C1 SP_C2 SP_C3 RV Q1 ON OFF Q 3346d02 3stage compressor with reversing valve in heating demand Applications #30 #39 SD_H3 Q4 SD_H2 SD_H1 SD_C1 SD_C2 SD_C3 Q3 Q2 Q2 Q3 Q4 ON SP_H3 SP_H2 SP_H1 SP_C1 SP_C2 SP_C3 OFF RV Q1 Q 3346d03 SP_H Setpoint heating stage Q1 Reversing valve SP_C Setpoint cooling stage Q2 Compressor 1 SD_ Switching differential Q3 Compressor 2 Q Load Q4 Compressor 3 Reversing valve (RV) Reversing valve can be energised in cooling or heating demand. It depends on the heat pump internal equipment circuitry. The reversing valve can be set to switch ON or OFF during no demand as shown on the above diagrams. 3/13

Universal input X1 Universal input X2 Digital input D1 Delay times The universal input X1 is used as the primary input for Ni 1000 sensor, Pt 1000 sensor or a DC0 10V active input. The universal input X2 is used as the secondary input for Ni 1000 sensor, Pt 1000 sensor, digital input, active/passive remote setpoint transmitter or a DC0 10V active input. The digital input D1 is used to enable the digital functions. Changeover occurs via potentialfree contact between terminals D1GND. The controller has adjustable output delay times to protect equipment from switching on/off too frequently. Delay inimum On time inimum Off time Interstage delay (stage 1 stage 2 stage 3) Changeover delay (heating demand cooling demand) Winter Summer setpoint changeover Range 0 4096sec 0 4096sec 0 4096sec 0 4096sec 0 23Hours 59min Applications Example: ain loop Air conditioning plant with temperature control. 2stage heating and 2stage cooling. X1 Room temperature Q1 Heating stage 2 Q2 Heating stage 1 Q3 Cooling stage 1 Q4 Cooling stage 2 3346s01 Q1 Q2 Q3 Q4 X2 X1 Auxiliary and digital functions Standby A switch contact (via time clock, thermostat) between X2 or digital input D1GND is used to enable the standby mode. During standby mode, all Q outputs are OFF. If X2 is used as a standby function then D1 can be set as a day/night, filter alarm or an alarm. 3346s02 Q1 Q2 Q3 Q4 D1 X2 X1 4/13

Remote setpoint A remote setpoint transmitter or an integrated sensor with setpoint (QAA25, QAA25/AP), connected to X2 enables remote adjustment. 3346s03 Q1 Q2 Q3 Q4 X2 X1 Heating stage 1 is the remote setpoint and the reference setpoint. A shift setpoint ( ) is set between the stages. The example shown is the remote setpoint parameters for a 2stage compressor. H2 C1 C2 3346d08 Remote Setpoint Alarm A switch contact between X2 or D1 GND is used to enable the alarm function. When the contact is closed, all Q outputs are off and the alarm icon flashes on the LCD. The alarm function overrides all the other auxiliary and digital functions. If X2 is used as an alarm function then D1 can be set as a day/night, standby or a filter alarm. 3346s04 Q1 Q2 Q3 Q4 D1 X2 X1 Filter alarm A switch contact (via air pressure switch) between X2 or D1 GND is used to implement a filter alarm indication. All Q outputs are not affected by filter alarm function. If X2 is used as a filter alarm function then D1 can be set as a day/night, standby or an alarm. p 3346s05 Q1 Q2 Q3 Q4 D1 X2 X1 Setpoint compensation The main setpoints are shifted over a range corresponding to a range measured by input X2. The most common application is to shift the main setpoints according to outside air temperature. 3346s06 Q1 Q2 Q3 Q4 X2 X1 Sensor averaging Two signals are connected to X1 and X2. The average between both is the controlling signal used by controller. 3346s07 Q1 Q2 Q3 Q4 X2 X1 5/13

Winter/Summer setpoint changeover F This application is used mainly on water heat pumps supplying twopipe FCU or radiator systems. T Digital changeover (X2 = Digital input) When X2 is closed, summer setpoints are selected and only cooling is active. When X2 is open, winter setpoints are selected Q1 Q2 Q3 Q4 X1 X2 D1 and only heating is active. Analog changeover (X2 = Outside air temperature 3347s08 sensor) When the X2 > summer changeover setpoint, summer setpoints are selected and only cooling is active. When the X2 < winter changeover setpoint, winter setpoints are selected and only heating is active. The above application, D1 is set as an Alarm. If the flow switch detects no flow, the outputs will be OFF. Sensor select Two sensors connected to X1 and X2. A switch on the wall is used to select the controlling sensor. When the switch breaks, the controller selects X1 as the controlling signal. 3346s09 Q1 Q2 Q3 Q4 X2 X1 ain loop active Default value for X1 is active DC0 10V and X2 is the standby mode input. 3346s10 Q1 Q2 Q3 Q4 X2 X1 Day/night setpoint A switch contact between D1 can be used to implement setpoint changeover for day/night operation. When contact is open, the setpoints for day operation are selected. When contact is closed, the setpoints for night operation are selected. During night operation, the remote setpoint and setpoint compensation functions are not applicable. 3346s11 Q1 Q2 Q3 Q4 D1 X2 X1 RWD34 & RWD4 6/13

3346z01 echanical Design Housing Protective housing ARG62.21/ARG62.22 ounting options Terminals Operating and display elements The RWD34 and RWD44 controllers are as per DIN 43 880 Gr. 1 requirements. A protective housing is used to protect the controller when mounted outside a control panel, such as on ducts, walls and in plant rooms. Furthermore, the protective housing prevents inadvertent contact with voltage supplying parts such as the connecting terminals. The RWD34 and RWD44 clip into the protective housing. The cable entries are located at the top and the bottom of the protective housing. The front has an opening for the LCD display and the programming buttons. The RWD34 and RWD44 universal controllers can be mounted as follows: In a standard electrical control cabinet as per DIN 43 880 Wall mounted in a protective housing Front mounting with standard available installation elements Plugin screw terminals The RWD34 and RWD44 are operated by the buttons on the controller front. Additional tools are not necessary. A 9pin port is provided for optional programming via the software tool. LCD Operating buttons SELECT The LCD shows the following information for normal operation: Current operating values (maximum 4 digits) Current setpoints (day/night) Application number Output status Auxiliary input value Selected auxiliary function The controller has three operating buttons for the following functions: The SELECT button is used to enter or save the value adjustment. The operating buttons are used for viewing and adjusting parameters. Parameter setting To configure the controller, follow the instructions supplied with the controller. Software Tool A software tool for controller application selection and parameter adjustment is available. It is a userfriendly Windows 95 (or above) based software tool which provides you a printout of the controller settings 7/13

Engineering notes Intended use Use this controller only for applications as described in the description on the title page (bold print) and the section "Use". Additionally, observe all conditions and restrictions imposed in this section and in "Technical data". The sections marked with a warning symbol contain technical safety requirements and restrictions. Observe all of these warnings as they directly relate to the protection of personnel and equipment. Installation notes The RWD34 and RWD44 controllers can be mounted as follows: Observe all local installation and mounting regulations. A B C D On a DIN rail (EN 50 02235 x 7.5) at least 120 mm long Wall mounted with 2 screws Front mounted using standard elements. e.g. 1x DIN rail 150 mm long 2x hexagonal placeholders 50 mm, washers and screws In the ARG62.21/ARG62.22 protective housing 3341z02 A B C D Electrical installation Standard cables can be used for the controller. However, when mounting in an environment greatly exposed to EC, use only shielded cables. The RWD34 is designed for AC 230V operating voltage The RWD44 is designed for AC 24 V operating voltage. The low voltage must comply with the requirements for safety extralow voltage (SELV) as per EN 60730. Use safety insulating transformers with double insulation as per EN 60742; they must be designed for 100 % ontime. When using several transformers in one system, the connection terminals G0 must be galvanically connected. Supplying voltages above AC 24 V to low voltage connections may damage or destroy the controller or any other connected devices. Additionally, connections to voltages exceeding AC 42 V endanger personnel safety. 8/13

Commissioning notes A booklet is supplied with the RWD34 and RWD44 controllers for commissioning. Observe the following: The controller must be configured for plantspecific operation using standard application number. Plant specific fine tuning can be performed if required (refer to the commissioning booklet). Power supply to the controller and the connected devices must be guaranteed Values and settings entered are retained after lost of power. Technical data General data Power supply Power consumption LCD Display resolution for (these values do not relate to the controller accuracy) Environmental conditions Environmental conditions IP code Operating voltage RWD34 Operating voltage RWD44 Safety extralow voltage (SELV) as per Frequency RWD34 RWD44 Actual and nominal values Ni 1000 Ω Pt 1000 Ω Active sensor Transport Climatic conditions Temperature Humidity echanical conditions Operation Climatic conditions Temperature Humidity Housing Front and with ARG62.21 Front and with ARG62.22 AC 230 V 10% 15% AC 24 V ±20 % EN 60730 50 Hz/60 Hz 6 VA 4 VA 4 digits 0.5 C 0.5 C Depends on the setting range IEC72132 Class 2K3 25...70 C <95 % r.h. Class 22 IEC72133 Class 3K5 0...50 C <95 % r.h. IP 20 as per EN 60529 IP 30 as per EN 60529 IP 30 as per EN 60529 Product standards Automatic electrical controls for household and similar use EN 60730 Conformity Other international approval Terminals Weight without packaging In accordance with European Union directives Electromagnetic compatibility EC Low voltage directive Emissions Immunity Safety C tick compliance Screw terminals for cables with RWD34 RWD44 89/336 EEC 73/23 EEC EN 500811 EN 500821 EN 60730 N474 min. 0.5 mm dia. max. 2 x 1.5 mm 2 or 2.5 mm 2 0.360 kg 0.300 kg 9/13

Analog inputs X1, X2 Ni 1000 Ω at 0 C Pt 1000 Ω at 0 C Analog voltages (for measured variables in C, % or without unit) Remote setpoints X2 Digital input D1 Controller easuring Range ax. cable length for dia. 0.6 mm Controller easuring Range ax. cable length for dia. 0.6 mm Range ax. cable length for dia. 0.6 mm Range ax. cable length for dia. 0.6 mm Polling voltage for control commands (D ) Current consumption 50 150 C max. 300 m 20 180 C max. 300 m DC 0 10 V corresponding to adjustable range from 100 to 2400 ( C, % or no unit) max. 300 m 0...1000 Ω corresponding to adjustable range from 100 to 2400 ( C, % or no unit) max. 300 m DC 15 V <10 ma Digital outputs Q.. Relay contacts (potentialfree) Voltage aximum rating inimum rating AC 24...230 V AC 230 V, 4 A resistive, 3 A ind. (per relay terminal) DC 30 V, 4 A AC 19.2 V, 20 ma DC 5 V, 100 ma Diagrams Internal diagrams L D1 GND X1 X2 TOOL RWD34 Q1 Q2 Q3 Q4 N 14 11 22 24 21 32 34 31 44 41 G D1 GND X1 X2 TOOL RWD44 Q1 Q2 Q3 Q4 G0 14 11 22 24 21 32 34 31 44 41 D1 G, G0 L, N Q X1 X2 Tool Digital Input AC24V supply ( SELV AC 24 V Power supply) AC230 V supply Ground (G0) for signal inputs and universal inputs Relay outputs, various voltages permissible Signal input (main input: Ni 1000, Pt 1000 and DC0 10 V) Signal input (aux. Input: Ni 1000, Pt 1000, DC0 10 V and remote setting unit) Communication port with PC (9pin plug) 10/13

Connection diagrams 2stage heating and cooling Applications #10 #19 AC 230V AC 24V G B AC 24V (L) 3346g03 S1 X1 X2 L G D1 GND X1 X2 11 21 31 41 Q N G0 TOOL 14 22 24 32 34 44 PC H2 H1 C1 C2 N G0, G0 (N) 3stage compressor Applications #20 #39 AC 230V AC 24V AC 24V (L) 3346g02 G B S1 X1 X2 L G D1 GND X1 X2 11 21 31 41 Q N G0 TOOL 14 22 24 32 34 44 PC RV CR1 CR2 CR3 N G0, G0 (N) CR1 CR2 CR3 RV H1 H2 C1 C2 X1 X2 S1 PC Note: Compressor 1 Compressor 2 Compressor 3 Reversing valve Heat 1 Heat 2 Cool 1 Cool 2 ain temperature sensor Auxiliary sensor or switch Switch or time clock Personal computer For a single compressor, CR2 &CR3 are not connected For a dual compressor, CR3 is not connected 11/13

3346m01 106 200 200 89 Please note that the TOOL signal ground is galvanically connected to G0 inside the controller. If the signal line of the computer is grounded to Earth, the G0 line after TOOL connection will be earthed as well. This will change the SELV to a PELV. Dimensions 130 111 56.5 47.9 31 148 61.2 ARG62.21 344 61.2 ARG62.22 12/13

Appendix Application numbers ain Loop H = Heating C = Cooling Cr = Compressor RV = Reversing valve RV RV Auxiliary Loop #1x (2H & 2C) #2x (3stage Cr RV cool ) # 3x (3stage Cr RV heat ) #x0 (Standby) #10 #20 #30 #x1 (Remote setpoint) #11 #21 #31 #x2 (Alarm) #12 #22 #32 #x3 (Filter alarm) #13 #23 #33 #x4 (Comp. shift) #14 #24 #34 #x5 (Avg. X1, X2) #15 #25 #35 #x6 (Win/Sum digital) #16 #26 #36 #x7 (Win/Sum analog) #17 #27 #37 #x8 (Sensor select) #18 #28 #38 #x9 (Active input) #19 #29 #39 13/13