YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Similar documents
york air-conditioning products Residential & VRF News 2015

FULL DC INVERTER SYSTEMS

Inverter Air Conditioning for Light Commercial Use

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

DUCTED AIR CONDITIONING SOLUTIONS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Chilled Water Precision Air Conditioner For Critical Application

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Cooling kw Heating kw

Appendix - Controllers 179

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

CRAC Precision climate control units for data centres

Unico Inverter. Unique and efficient.

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

FTQ. Daikin Inverter Ducted Heat Pump

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Air Conditioning for Small and Medium-size Buildings

ECO-AIR AIR CONDITIONING

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

NEW 3-PIPE ECOi MF2 SERIES

ECOCIAT. Domestic hot water heat recovery unit

GREE, MAKING BETTER AIR CONDITIONERS

Pioneer in sustainability

HP switch LP switch Discharge thermo Comp. Surface thermo

FTXS. Wall Mount Heat Pump or Cooling Only

Air Conditioners Technical Data

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

2010 Duct-Free Splits Line Card

FBQ. DC Duct Heat Pump or Cooling Only

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

LG Electronics AE Company, Commercial Air Conditioning

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

-~ available. Power consumption during operation is substantially less than that of lower rated

DM en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3

PRODUCT CATALOG. Indoor Units

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

innovative comfort solutions

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Rotary screw compressors kw 5,5 7, , bar MODULO

Residential and Light Commercial Air Conditioning Systems

AIR CONDITIONING and HEAT PUMP PRODUCTS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Introduction To VRF: System Overview, Applications, & Savings Opportunities

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Samsung Room Air Conditioning

FHQ. Ceiling Suspended Heat Pump or Cooling Only

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Split System Heat Pump Product Data

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

2015 / 16. price list. Airconditioning systems

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Air Conditioning For Large Buildings

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Inverter Air Conditioning for Light Commercial Use

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SWIMMING POOL HEAT PUMP

Technical Service Manual. Version One

Glossary of Heating, Ventilation and Air Conditioning Terms

Technical data. Danfoss DHP-A

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Commercial Gas Heat Pump - VRF

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Failure code manual. content

Air conditioners Heating & Cooling

Condensing unit type EPSILON-ECHOS LE Technical information manual

CoolTeg Plus Chilled Water (CW) version: AC-TCW

LG AIR CONDITIONING SYSTEMS

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Transcription:

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Table of Contents Serving your needs since 1874 1 Product Benefits 3 Product Features 4 Product Functions 6 Product Technologies 9 Smart Control 10 Indoor Units 14 Product Portfolio 20 Product Nomenclature 21 Product Specifications 23

Serving Your Needs Since 1874. A century of innovation Established in 1874 in York, Pennsylvania, YORK has helped our customers meet their temperature control needs for over a century. Now a Johnson Controls brand, YORK continues to benefit customers through research that has gone on to claim several significant firsts in design and innovation. Johnson Controls is able to provide our customers with the best temperature control solutions available around the world today. Pioneer in Inverter technology Our customers can be assured that they will enjoy the benefits of the latest technology when they choose a Johnson Controls product, as YORK has always been at the forefront of adopting new technologies for their offerings. From being the first to offer a low pressure VSD unit in 1979 to introducing the inverter technology in the 21st century, YORK has demonstrated its pioneering spirit. Leader in reliability When constructing products, YORK places our customers needs as the top priority of our design process. Significant Milestones 1935 First to develop a successful single-room air conditioner 1954 First to offer year-round air-conditioning 1979 Launched the first Low Pressure VSD Driven Centrifugal Chiller 2004 Launched the first VSD Driven Air Cooled Screw Chiller 2005 Applied VSD in YORK Industrial Refrigeration Screw Chiller 2011 Launched the YES Mini Residential Inverter VRF, Magnetic VSD Centrifugal Chiller, VSD Driven Water Cooled Screw Chiller 2012 Launched the YES Slim Residential/ Commercial Inverter VRF, YES Super Commercial Inverter VRF Our inverter VRF units are produced using state-ofthe-art lean manufacturing techniques, and rigorous quality testing is implemented at every step of the manufacturing process, before they are shipped to customers. YES Mini VRF Series 1

Endorsed by Iconic Buildings. YORK s HVAC systems have been installed in many of the world s most famous landmarks. YORK makes systems for structures of all sizes that bring innovation, comfort and design wherever people live, work and play. 2 YES Mini VRF Series

Product Benefits YORK Variable Refrigerant Flow (VRF) At Johnson Controls, we always seek to anticipate what customers are looking for and strive to provide the temperature control systems that will meet their myriad of needs. YORK VRF air-conditioners offer customers a range of benefits that is unparalleled in the air-conditioner market. Energy Efficient Customers looking to save money will be delighted to know our air-conditioners can help reduce costs as the highly energy-efficient VRF units will help you decrease the power you use. Wide Ambient Range Customers can take comfort in knowing that our inverter VRF air-conditioners can operate in extreme weather conditions, running safely even when ambient temperature is up to 52 0 C for cooling or -20 0 C for heating. 48 to 52 0 C cooling or -15 to -20 0 C heating will be running at intervals. Smart Control Customers can take more effective control of their air-conditioners with a variety of technology tools available for our units. Our advanced suite of control solutions include: three types of touch screen controllers, smart home connection and building automation systems using the Metasys software. Versatility We understand that no two customers are the same. That s why we ve designed our air-conditioning systems to be versatile enough to meet our customers differing needs. From product selection to installation to commissioning, YORK YES Series offers impressive flexibility. Greater Comfort We know that enjoying comfort at the right temperature is one of our customers foremost desires. We have the technology to deliver that comfort, including a BLDC (Brushless Direct Current) fan motor with adjustable speeds, anti-vibration and soundinsulation technology. YES Mini VRF Series 3

Product Features oling m 5m 70 Part ceiling Narrow install Heating Mini Outdoor Fin General Louvered Fin Environmental Protection Our highly energy efficient Inverter VRF units provide environmental protection by Night Mode using the eco-friendly Cooling R410A refrigerant. Night Mode Heating Outdoor to be set at night mode Lower fan speed during overnight operation JCI YES-Mini Outdoor Fin General Louvered Fin Wide Ambient Range Indoor EXV 52C -20C gn for models 35/40/50/60 Low-pressure Sensor Capacity-Priority Mode Capacity-Priority Mode High-pressure Sensor With wide ambient temperatures ranging from 52 C in cooling mode to -20oC in o Outdoor to be set at capacitypriority mode Load needs priority heating mode, the air-conditioning units can be used in various environments. Time Heating Capacities Inlet/outlet Temperature of the Heat Exchanger Durations Outdoor Temperature 1.8kW~5 0~30Pa General Air Conditioner YES-mini 15~80Pa 6.6kW~11.5kW 15~100Pa 14kW~17.5kW 3-row Heat Exchanger 1. Diagnostic Kit 2. Outdoor Control Board Ind Heating Cooling 3. Computer Software Three-row design for models 35/40/50/60 Communication cables Power cables Heating JCI YES-Mini Cooling Outdoor Fin General Louvered Fin Touch Screen Wired Control JCI YES-Mini Outdoor Fin General Louvered Fin Take control of your system with our smart touch screen wired controllers, which is Inl Tem available in different colours to suit your own personal taste. It also features a built-in of Nig Ex signal receiver. Nig Ou Ceiling Three-row Heat-Exchanger 1. Diagnostic Kit Ca Indoor EXV Low-pressure Sensor High-pressure Sensor Our units are built with a three-row heat-exchanger, improving unit performance even Three-row design for models 35/40/50/60 Three-row design for models 35/40/50/60 Ou pri Loa 2. Outdoor Control Board Time Heating Capacities Three-row design for models 35/40/50/60 Field Wiring Design Inlet/outlet Temperature of the Heat Exchanger The field wiring design on our outdoor units provides convenience in wiring connection 3. Computer Software Durations General Air Conditioner through the availability of a detachable handle on its side. This also prevents noise YES-mini problems and damage to the exteriror. 1. Diagnostic Kit Outdoor Temperature cables 3. Computer Software 1. Diagnostic Kit Communication cables Power cables 4 YES Mini VRF Series Ca under extreme temperatures. 2. Outdoor Control Communication Board Power cables Low op 2. Outdoor Control Board 3-row Heat Exchanger

Rare-earth Permanent Magnet DC Inverter Compressors The rare-earth permanent magnet DC inverter compressors in our units are capable of forming powerful and permanent magnetic fields, which enables the compressor to operate at high efficiency when switched on. The rotors in these compressors are fixed with slip-rings to seal the cylinder, thereby reducing abrasion and extending the lifespan of the compressor. Noise Reduction Technology The noise reduction technology, made possible by DC scroll inverter compressors, BLDC fan motor with adjustable speeds, anti-vibration and sound-insulation technology, ensures that the air-conditioners operate quietly by cutting down the operational noise levels. YES Mini VRF Series 5

Product Functions Intelligent Piping Length Adaptation This system consists of a high-pressure sensor, low-pressure sensor and real-time temperature monitor, measuring compressor discharge and suction temperatures, indoor Heating evaporator temperatures, as well as tube temperatures in the heat exchanger. This allows operating pressure and compressor operating frequency to be automatically adjusted under different piping length conditions. uvered Fin Indoor EXV Low-pressure Sensor High-pressure Sensor Two Quiet Operation Modes Part ceiling Part ceiling The availability of Night Mode and Capacity-Priority Mode allows for quiet operation Heating Capacities throughout the day. The Night Mode prompts the fan to be running at lower speed during overnight operations, while the Capacity-Priority Mode takes into consideration Inlet/outlet surrounding air Temperature fluctuations to adjust fan speed. of the Heat Exchanger Durations Outdoor Temperature 2. Outdoor Control Board Indoor EXV Low-pressure Sensor High-pressure Sensor Indoor EXV Low-pressure Sensor High-pressure Sensor Night Mode Outdoor to be set at night mode 3-row Heat Exchanger Capacity-Priority Mode Capacity-Priority Mode Capacity-Priority Mode Capacity-Priority Mode Outdoor to be set at capacitypriority mode Outdoor to be set at capacitypriority mode Load needs priority Load needs priority 3. Computer Software Durations Durations Time Heating Heating Capacities Capacities 6 YES Mini VRF Series Outdoor General Air Conditioner YES-mini Outdoor to be set at night mode Lower fan speed during overnight operation Lower fan speed during overnight operation 1. Diagnostic Kit Inlet/outlet Temperature Inlet/outlet of the Heat Temperature Exchanger of the Heat Exchanger Night Mode Night Mode Night Mode General Air Conditioner General Air YES-mini Conditioner Time 15~80Pa 15~80Pa 15~100Pa 15~100Pa 3-row Heat 0 0 6 6 1 1

JCI YES-Mini Outdoor Fin General Louvered Fin Cooling Heating Three External Static Pressure (ESP) Settings JCI YES-Mini General Louvered Fin A 3-4HP outdooroutdoor unit withfina single fan can reach external static pressures as high as 30 Pa, while a 4.5-6HP outdoor unit with two fans can reach 40 Pa. Installing an air duct to redirect airflow is feasible with the ESP setting. Indoo Three-row design for models 35/40/50/60 Inlet/o Tempe of the Excha Three-row design for models 35/40/50/60 1. Diagnostic Kit Three Approaches for Address Setting The system offers three system setting approaches for ease of testing and installation of 2. Outdoor Control Board units: Auto address setting with diagnostic kit Auto address setting with outdoor unit Auto address setting on computer 3. Computer Software 1. Diagnostic Kit Communication cables Power cables 2. Outdoor Control Board 3. Computer Software Communication cables Maximum Safety Power cables Our units guarantee safety by having in place: m 5m 70 Part ceiling 1. High pressure/low pressure protections Narrow corridor installation 1.8kW~7.1kW 8.0kW 2. Compressor internal overload protection Fin 9.0kW~11.2kW 2.8kW 4.5kW 5.6kW/7.1 3. Time delay for compressor restart, among other protection systems Night Mode Night Mode Outdoor to be set at night mode Lower fan speed during overnight operation Top air outlet Sid Cooling: good He good Coo He B A York air outlet YES Mini VRF Series 7 Capacity-Priority Mode Indoor EXV Low-pressure Sensor High-pressure Sensor Capacity-Priority Mode Outdoor to be set at capacitypriority mode Load needs priority Cooling: good He weak

Automatic Fault Alarm The wired controllers of the indoor and seven-segment LED of outdoor units automatically display information of any system failure, which makes trouble-shooting problems easier. Heating uvered Fin Intelligent Defrost By monitoring outdoor temperatures, inlet/outlet temperatures of the heat exchanger, as well as the duration for intelligent defrost, the system can efficiently conduct defrost cycles. This also eliminates the problem of dust affecting the heat exchange capacity and possibly triggering an auto-defrost, which thus enables uninterrupted heating. Inlet/outlet Temperature of the Heat Exchanger Heating Capacities Time Night Mode Night Mode Outdoor to be set a Lower fan speed du operation Outdoor Temperature Durations General Air Conditioner YES-mini 3-row Heat Exchanger Capacity-Prior Indoor EXV Low-pressure Sensor High-pressure Sensor Capacity-Priority M Outdoor to be set a priority mode Load needs priority 1. Diagnostic Kit Refrigerant Recovery If the indoor or outdoor unit fail in the system, the refrigerant may be recovered to Time reduce its wastage. Inlet/outlet Temperature of the Heat Exchanger Outdoor Control Board with Seven-Segment Durations LED Display Our outdoor units feature three, seven-segment LED displays YES-mini Outdoor on their control boards to show the 3-row Heat Temperature Exchanger system s relevant information to make it more efficient to make diagnosis during servicing. Heating Capacities General Air Conditioner 2. Outdoor Control Board 3. Computer Software 8 YES Mini VRF Series

Product Technologies 180 DC Inverter Driver We adopted the 180 inverter driver control to reduce motor vibration and noise while enhancing the compressor operating frequency range. Special fresh air intake design for drivers (models 45-60) Our variable speed drivers have incorporated a special fresh air intake design to reduce the temperature of the driver. This enables the variable speed driver to operate at higher speeds and at higher ambient temperatures. Without Fresh Air Intake With Fresh Air Intake Sub-Cooling Design A sub-cooling coil is integrated in the outdoor heat exchanger to enable sub-cooling and reduce the capacity loss in the event of using long piping (length of piping varies according to the apartment size, shape and number of indoor units). Electronic expansion valve and check valve throttling On top of having an outdoor electronic expansion valve for heating purposes, our YES Mini system also comes with a check valve parallel to the electronic valve, so that the refrigerant may enter through it at cooling mode, thereby improving the life of the valve. Pressure and temperature sensors The outdoor units come equipped with high and low pressure sensors, as well as discharge, suction, heat exchanger and ambient temperature sensors. When used in combination, they provide a stable and effective system operation. New low resistance fan grille Our specially designed leaf shape fan grille reduces air resistance, adjusts the air discharge direction and avoids short circuit of return and discharge air. This improves the noise data, noise quality and the unit efficiency. YES Mini VRF Series 9

Smart Control Individual & Group control The indoor units in our YES Series can be controlled using wired and wireless controllers. Moreover, the wired controllers include a group control function and can connect up to four indoor units. Wired Controller Wireless Controller Group Control Group Control Individual Control The touch screen wired controllers come in a range of colours to suit your personal taste, and is equipped with TiO₂ control and wireless controller receivers. Gray Sky blue Green Brown 10 YES Mini VRF Series

On/Off Controller Our touch screen controllers can connect up to 256 indoor units or four VRF systems, and can switch those within the same zone on or off simultaneously. ** YDHW/YDCC can't connect to on/off controller. ON/OFF controller which can support Modbus or BACnet protocol for different application (need to choose the corresponding type of the controller). Central on/off control at the entrance/exit Central Controller Our seven-inch touch screen central controller can be mounted on the wall easily and connects up to 1,024 indoor units/ 512 groups/ 128 zones/ 16 VRF systems. In addition to having the same control functions as the wired controller, it also has a weekly schedule function. ** YDHW/YDCC can t connect to central controller. Central controller can support Modbus or BACnet protocol for different application (need to select the protocol mode). YES Mini VRF Series 11

Door Card Function The control boards in the YES indoor units come with a door card on/off signal function and feature two selection modes, which may be chosen using the door card and signal interface communication. Mode 1: The system automatically returns to the last operation mode when the card is inserted. Door Card Door Card Insert the door card Pull out the door card Mode 2: The system needs to be switched on manually when the card is inserted, so as to reduce electricity wastage. Door Card Door Card Insert the door card Door Card Pull out the door card 12 YES Mini VRF Series

BAS Connection Our YES Series can be connected to the Building Automation System to allow an integrated smart control solution. ** YDHW/YDCC can t connect to BAS connection. Metasys/Other BAS System BACnet/IP NAE Converter (JCI) BACnet communication board BACnet YES Mini VRF Series 13

Indoor Units Compact Ducted Indoor Unit Part ceiling 700mm 450mm Narrow corridor installation Compact design With a height of just 200mm and depth of 450mm, its compact size makes installation ideal for narrow spaces such as corridor of bedrooms or hotel rooms. Flexible air return The detachable air return baffle enables the direction of air return to be adjusted either downwards or backwards. ESP adjustable The adjustable external static pressure of the ceilingpackaged indoor unit supports different installations and generates optimal airflow. 0~30Pa 1.8kW~7.1kW Sleep mode Sleep mode may be selected via a wired controller. Ceiling (Unit: mm) Optional drainage pump The ceiling-packaged indoor unit fits in the narrowest of spaces where the drainage pump is not required. However, a drainage pump is available in case there is enough room in the ceiling and the drainage distance is long. 14 YES Mini VRF Series

Ceiling-concealed (Low Static Ducted) Indoor Unit Compact design Part ceiling 700mm Narrow corridor installation With a height of just 200mm and width of 700mm (018 045), its compact size makes installation ideal for narrow spaces such as corridor of bedrooms or hotel rooms. Flexible air return The air return baffle is detachable. The direction of air return can be adjusted during installation, either downward or backward. 1.8kW~7.1kW 8.0kW 9.0kW~11.2kW ESP adjustable The external static pressure of the ceiling-packaged indoor unit is adjustable, supporting different installations and delivering optimal airflow. Sleep mode Sleep mode can be selected via a wired controller. Ceiling (Unit: mm) Optional drainage pump The ceiling-packaged indoor unit fits in the narrowest of spaces where the drainage pump is not required. However, if there is enough room in the ceiling and the drainage distance is long, a drainage pump is available. YES Mini VRF Series 15

Ceiling-concealed (Medium Static Ducted) Indoor Unit ESP Adjustable The external static pressure of our ceiling-concealed indoor units is adjustable, which supports different installations and provides optimal airflow. 15~80Pa 15~100Pa 0~30Pa 2.0kW~5.3kW 6.6kW~11.5kW 14kW~17.5kW Sleep mode Sleep mode may be selected via a wired controller. - slim and fits in the mp is not required. iling and the drainage l for selection. 310mm 2-Way Cassette Indoor Unit Ceiling (Unit: mm) 520mm Complete product line Seven models ranging from 2.8 kw to 11.2 kw are available for selection. 840~1440mm Compact design A standard, compact design of 520 mm depth and 310 mm height is adopted across all models, making installations easier. Max=500mm Standard drainage pump The unit has a standard drainage pump capable of draining up to 500 mm of water, and is ideal for draining condensation over longer distances. Standard 16 YES Mini VRF Series

Round-way Cassette Indoor Unit 360 degree circulation Room temperature, airflow and noise control are regulated and maintained throughout the room. Blind angles of air distribution Minified blind angles 360 good air distribution Oblique view Oblique view Elevation view Elevation view Different height setting Wired controllers can be set to normal ceiling mode or high ceiling mode, providing comfort. Oblique view Elevation view Fresh air intake Fresh air can be introduced directly. Fresh air Intake Fresh air Intake ribution Brushless Direct Current (BLDC) fan motor With a spiral multi-blade fan and a large-diameter design, the fan noise can be effectively reduced and air volume can be more precisely controlled. Fresh air Intake High efficiency drainage pump The maximum distance between the cassette unit and drainage pump is as high as 750 mm. YES Mini VRF Series 17

High Wall Indoor Unit Complete product line Five compact and attractive models from 2.2 kw to 7.1 kw are available for selection, which are suitable for residential to light commercial applications. Whole Package Design The Electronic Expansion Valve (EEV) fitted inside the unit chamber eliminates the need for external installations. Low noise High efficiency/ low noise motors and fan impellers are adopted to enable quiet operations down to 28dB(A). There is also a standard filter fitted for healthier use. Floor/ Ceiling Indoor Unit 680mm Complete product line Eight models from 2.8 kw to 11.2 kw are available. Floor and ceiling installations are convertible for job sites. 240mm 1245~1670mm Compact design A standard, compact design of 240 mm depth and 680 mm height is adopted across all models, making installations easier. Max=500mm Optional drainage pump The indoor ceiling unit has an optional drainage pump capable of draining up to 500 mm of water, and is ideal for draining condensation over longer distances. Option 18 YES Mini VRF Series

Floor-concealed Indoor unit Complete product line Top air outlet Side air outlet York air outlet Four models from 2.8 kw to 7.1 kw are available. A B Better air distribution Our air outlets are tilted at a 45-degree angle which helps optimize air distribution for cooling and heating. Compact design A standard, compact design of 230 mm depth and 600 mm height is adopted across all models, and is suitable 600mm for floor-concealed installations in cabinets. 230mm 730~1334mm YES Mini VRF Series 19

Product Portfolio Indoor Cooling Capacities kw Types 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 Compact Ducted Y Y Y Y Y Y Y Y Y Y Low Static Duct (YDCP) Y Y Y Y Y Y Y Y Y Y Medium Static Ducted (YDCC)* Y Y Y Y Y High Wall (YDHW) Y Y Y Y Floor/Ceiling (YDEC) Y Y Y Y Floor-Concealed (YDVC) Y Y Y 2-Way Cassette (YDDK) Y Y Y Y Round Way Cassette (YDCK) Y Y Y Y Y Y Cooling Capacities kw Types 6.3 7.1 8 9 10 11.2 12.5 14 17.5 Compact Ducted Y Y Low Static Duct (YDCP) Y Y Y Y Y Y Medium Static Ducted (YDCC)* Y Y Y Y Y Y High Wall (YDHW) Y Floor/Ceiling (YDEC) Y Y Y Y Floor-Concealed (YDVC) Y 2-Way Cassette (YDDK) Y Y Y Round Way Cassette (YDCK) Y Y Y Y Y Y Y Y *approximate data Capacity 3HP 3.5HP 4HP 4HP 5HP 6HP Cooling Capacities 8 kw 10 kw 11.2 kw 12 kw 14 kw 16 kw Heating Capacities 9.5 kw 11.2 kw 12.5 kw 12.5 kw 16 kw 18 kw Models YVOH30 YVOH35 YVOH40 YVOH45 YVOH50 YVOH60 20 YES Mini VRF Series

Product Nomenclature Outdoor Certification, Default: No Special Certificate Conditions, Default: Local T1, 1: Export T1 Design Series Number Design Code Structure, H: Horizontal Discharge Power Supply, A: 220V/1PH-50Hz, K: 220-240V/1PH-50Hz Cooling Capacity Code Mode of Operation, H: Heat Pump Outdoor Unit V: Variable Refrigerant Flow (VRF) Air Conditioner Y: YORK E Series Indoor 0 E 3 Condition, 1: Export T1; 3: Export T3 Design Series Number: E Series(R410A) Design Code Power Supply, A: 220V/1PH-50Hz Expansion Device, N: Internal EXV No Drainage Pump, P: Interal EXV With Drainage Pump Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater Mode of Operation, C: Cooling Only, H: Heat Pump Cooling Capacity Code in 100W Indoor Unit Type, CD: Compact Ducted, CP: Ceiling Packaged Ducted (Low Static), CK: Round-way Ceiling Cassette, DK: 2-way Ceiling Cassette, EC: Floor/Ceiling, VC: Floor Conceal, HW: High Wall D:Variable Refrigerant Flow(VRF) Air Conditioner Y:YORK YES Mini VRF Series 21

C Series Indoor Units H F L E 2 C 3 Condition, 3: Export T3 Design Series Number: C Series(R410A) Design Code Power Supply, A: 220V/1PH-50Hz Expansion Device, E: Internal Piping, L:Left, R: Rightl Return Plenum, F: With Back Return Plenum and Filter Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater Mode of Operation, C: Cooling Only, H: Heat Pump Cooling Capacity Code in 100W Indoor Unit Type, CC: Medium Static Ducted D: Variable Refrigerant Flow(VRF) Air Conditioner Y:YORK 22 YES Mini VRF Series

Product Specifications YES Mini Outdoor Outdoor Unit Model YVOH30KH YVOH35KH YVOH40KH YVOH45AH YVOH50AH YVOH60AH HP 3.0 3.5 4.0 4.5 5.0 6.0 Power Supply (V/Ph/Hz) 220/1/50 Capacity (kw) Power (kw) Efficiency (W/W) Cooling 8.0 10.0 11.2 12.0 14.0 16.0 Heating 9.5 11.2 12.5 12.5 16.0 18.0 Cooling 2.13 3.00 3.41 3.00 3.88 4.72 Heating 2.31 3.12 3.47 3.12 3.78 4.50 Cooling EER 3.76 3.33 3.28 4.00 3.61 3.39 Heating COP 4.11 3.59 3.60 4.01 4.23 4.00 IPLV (C) 5.25 5.20 5.35 5.35 5.60 5.30 Air Flow (m3/h) Standard 4100 4100 4700 6500 6500 6500 Dimensions (mm) H W D 882 x 995 x 360 1320 x 995 x 360 Weight (kg) Net Weight 90 93 95 110 115 125 Refrigerant Type R410A R410A R410A R410A R410A R410A Charge (kg) 2.7 3.0 3.5 3.7 4.5 5.1 Noise (db(a)) Cooling/Heating 48/50 49/51 51/51 51/53 52/55 52/55 Piping (ømm) Liquid 9.52 Gas 15.88 Max. 16.6 20.0 20.0 20.0 30.0 30.0 Current (A) Circuit Breaker 25 25 25 25 40 40 Nominal Cooling 9.8 13.8 15.7 14.5 17.8 21.7 Nominal Heating 10.6 14.3 15.9 15.1 17.4 20.7 Max. Piping Length 70 70 70 120 120 120 Max. Equivalent Piping Length 100 100 100 150 150 150 Piping Length/Height (m) Max. Height Difference between IU/OU (OU above IU) Max. Height Difference between IU/OU (IU above OU) 30 15 15 15 20 20 20 Max. Height Difference (IUs) 15 Ambient Range Cooling ( CDB) Heating ( CWB) -5 52 (Interval Running at 48 to 52 C) -20 24 (Interval Running at -20 to -15 C) Max. Indoor Unit No. 5 7 8 8 10 11 YES Mini VRF Series 23

Compact Ducted Indoor Unit Indoor Unit Model YDCD 018 H0NA YDCD 022 H0NA YDCD 025 H0NA YDCD 028 H0NA YDCD 032 H0NA YDCD 036 H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 1.8 2.2 2.5 2.8 3.2 3.6 Heating 2.2 2.5 2.8 3.2 3.6 4.0 Power Input (W) 37 37 46 46 48 50 Current (A) Nominal 0.16 0.16 0.2 0.2 0.21 0.22 Air Flow (m3/h) - 350 350 450 450 480 480 ESP (Pa) Dimensions (mm) Standard (min-max) H W D 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 200X700 X450 200X700 X450 200X700 X450 200X700 X450 200X700 X450 200X700 X450 Weight (kg) Net Weight 23 23 23 23 23 25 Noise (db(a)) H/M/L 29/25/23 29/25/23 31/27/25 31/27/25 32/29/27 32/29/27 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.70 6.35/12.70 Drainage DN25 DN25 DN25 DN25 DN25 DN25 Indoor Unit Model YDCD 040 H0NA YDCD 045 H0NA YDCD 050 H0NA YDCD 056 H0NA YDCD 063 H0NA YDCD 071 H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 4.0 4.5 5.0 5.6 6.3 7.1 Heating 4.5 5.0 5.6 6.3 7.1 8.0 Power Input (W) 70 70 76 106 106 110 Current (A) Nominal 0.3 0.3 0.33 0.46 0.48 0.48 Air Flow (m3/h) - 560 560 750 900 900 990 ESP (Pa) Standard (min-max) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) Dimensions (mm) H W D 200X700 X450 200X900 X450 200X900 X450 200X900 X450 200 1100 450 200 1100 450 Weight (kg) Net Weight 25 30 34 34 34 34 Noise (db(a)) H/M/L 38/35/32 35/32/29 35/32/29 39/36/32 37/34/31 37/35/32 Piping (ømm) Liquid/Gas 6.35/12.70 6.35/12.70 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88 Drainage DN25 DN25 DN25 DN25 DN25 DN25 24 YES Mini VRF Series

Ceiling Packaged (Duct) Indoor Indoor Unit Model YDCP 018H0NA YDCP 022H0NA YDCP 025H0NA YDCP 028H0NA YDCP 032H0NA YDCP 036H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 1.8 2.2 2.5 2.8 3.2 3.6 Heating 2.2 2.5 2.8 3.2 3.6 4.0 Power Input (W) - 37 37 46 46 48 50 Current (A) Nominal 0.16 0.16 0.20 0.20 0.21 0.22 Air Flow (m3/h) - 350 350 450 450 480 480 ESP (Pa) Standard (min max) 0 (0 30) Dimensions (mm) H W D 200 700 620 Weight (kg) Net Weight 23 25 Noise (db(a)) H/M/L 27/25/23 27/25/23 28/26/24 28/26/24 30/27/25 30/27/25 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDCP 040H0NA YDCP 045H0NA YDCP 050H0NA YDCP 056H0NA YDCP 063H0NA YDCP 071H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 4.0 4.5 5.0 5.6 6.3 7.1 Heating 4.5 5.0 5.6 6.3 7.1 8.0 Power Input (W) - 70 70 76 106 106 110 Current (A) Nominal 0.30 0.30 0.33 0.46 0.48 0.48 Air Flow (m3/h) - 560 560 750 900 900 990 ESP (Pa) Standard (min max) 0 (0 30) Dimensions (mm) H W D 200 700 620 200 900 620 200 1100 620 Weight (kg) Net Weight 25 25 30 34 Noise (db(a)) H/M/L 35/32/29 35/32/29 33/31/28 37/34/30 35/33/29 36/33/30 Piping (ømm) Liquid/Gas 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCP080H0NA YDCP090H0NA YDCP100H0NA YDCP112H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 8.0 9.0 10.0 11.2 Heating 9.0 10.0 11.2 12.5 Power Input (W) - 138 206 260 260 Current (A) Nominal 0.60 0.90 1.25 1.25 Air Flow (m3/h) - 1200 1500 1700 1700 ESP (Pa) Standard (min max) 15 (0 40) Dimensions (mm) H W D 200 1100 620 220 1450 620 Weight (kg) Net Weight 34 48 Noise (db(a)) H/M/L 39/36/31 39/36/31 41/37/33 41/37/33 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 25

Ceiling Concealed (Medium Static Duct) Indoor Indoor Unit Model YDCC 020H0FLEA YDCC 025H0FLEA YDCC 034H0FLEA YDCC 045H0FLEA YDCC 053H0FLEA YDCC 066H0FLEA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.0 2.5 3.4 4.5 5.3 6.60 Heating 2.20 3.00 3.90 4.95 5.80 6.80 Power Input (W) - 40 55 75 100 110 185 Current (A) Nominal 0.35 0.35 0.40 0.46 0.52 0.96 Air Flow (m3/h) - 380 450 600 800 930 1200 ESP (Pa) Standard (min max) 15 (0 30) 15 (15 80) Dimensions (mm) H W D 226 855 602 226 1055 602 226 1175 602 245 1475 576 Weight (kg) Net Weight 20 20 23 25 25 32 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCC 078H0FLEA YDCC 095H0FLEA YDCC 115H0FLEA YDCC 140H0FLEA YDCC 175H0FLEA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.80 9.50 11.5 14.0 17.5 Heating 8.20 11.0 13.0 16.5 19.0 Power Input (W) - 215 270 300 420 510 Current (A) Nominal 1.08 1.29 1.30 1.90 2.11 Air Flow (m3/h) - 1360 1600 1900 2200 2700 ESP (Pa) Standard (min max) 15 (15 80) 15 (15 100) Dimensions (mm) H W D 245 1475 576 245 1805 576 430 1563 655 Weight (kg) Net Weight 33 41 41 58 65 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 26 YES Mini VRF Series

2-way Cassette Indoor Indoor Unit Model YDDK028H0PA YDDK036H0PA YDDK045H0PA YDDK056H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.5 5.6 Heating 3.2 4.0 5.0 6.3 Power Input (W) - 60 62 68 85 Current (A) Nominal 0.27 0.28 0.31 0.39 Air Flow (m3/h) - 500 600 770 900 Dimensions (mm) Weight (kg) Unit (H W D) 310 840 520 310 960 520 Panel (H W D) 30 1083 630 30 1203 630 Unit 41 41 47 47 Panel 6 6 7 7 Noise (db(a)) H/M/L 34/28/22 35/32/27 38/33/28 40/36/34 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDDK 071H0PA YDDK 090H0PA YDDK 112H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 9.0 11.2 Heating 8.0 10.0 12.5 Power Input (W) - 94 129 175 Current (A) Nominal 0.43 0.59 0.80 Air Flow (m3/h) - 1160 1500 1700 Dimensions (mm) Weight (kg) Unit (H W D) 310 1200 520 310 1440 520 Panel (H W D) 30 1443 630 30 1683 630 Unit 53 65 65 Panel 8 9 9 Noise (db(a)) H/M/L 42/38/35 42/38/35 46/43/38 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 27

Round-way Cassette Indoor Unit Model YDCK 028H0PA YDCK 036H0PA YDCK 040H0PA YDCK 045H0PA YDCK 050H0PA YDCK 056H0PA YDCK 063H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.0 4.5 5.0 5.6 6.3 Heating 3.2 4.0 4.5 5.0 5.6 6.3 7.1 Power Input (W) - 17 19 19 19 26 27 42 Current (A) Nominal 0.13 0.15 0.15 0.15 0.22 0.28 0.37 Air Flow (m3/h) - 780 810 810 810 900 960 1100 Dimensions (mm) Weight (kg) Unit (H W D) 246 840 840 Panel (H W D) 50 950 950 Unit 23 26 Panel 5.5 Noise (db(a)) H/M/L 28/27/25 29/28/26 31/29/27 32/31/28 32/31/28 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCK 071H0PA YDCK 080H0PA YDCK 090H0PA YDCK 100H0PA YDCK 112H0PA YDCK 125H0PA YDCK 140H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 8.0 9.0 10.0 11.2 12.5 14.0 Heating 8.0 9.0 10.0 11.2 12.5 14.0 16.0 Power Input (W) - 42 63 63 129 129 142 171 Current (A) Nominal 0.37 0.54 0.54 1.07 1.07 1.17 1.39 Air Flow (m3/h) - 1100 1500 1500 1900 1900 2010 2010 Dimensions (mm) Weight (kg) Unit (H W D) 246 840 840 288 840 840 Panel (H W D) 50 950 950 Unit 26 29 29 29 29 29 32 Panel 5.5 Noise (db(a)) H/M/L 35/31/28 38/35/32 45/39/36 47/43/38 48/45/42 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 28 YES Mini VRF Series

High Wall Indoor Indoor Unit Model YDHW 022H0NA YDHW 028H0NA YDHW 036H0NA YDHW 056H0NA YDHW 071H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.2 2.8 3.6 5.6 7.1 Heating 2.80 3.20 4.00 6.30 7.15 Power Input (W) - 35 35 40 50 70 Current (A) Nominal 0.18 0.18 0.23 0.25 0.35 Air Flow (m3/h) - 450 450 570 730 1050 Dimensions (mm) H W D 295 890 215 295 890 215 295 890 215 302 1070 220 302 1070 220 Weight (kg) Net Weight 14 14 14 16 16 Noise (db(a)) H/M/L 34/30/26 34/30/26 38/35/31 44/41/39 44/41/39 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN20 YES Mini VRF Series 29

Floor/Ceiling Indoor Indoor Unit Model YDEC028H0NA YDEC036H0NA YDEC045H0NA YDEC056H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.5 5.6 Heating 3.2 4.0 5.0 6.3 Power Input (W) - 110 110 130 130 Current (A) Nominal 0.55 0.55 0.65 0.65 Air Flow (m3/h) - 600 600 950 950 Dimensions (mm) H W D 680 x 1245 x 240 Weight (kg) Net Weight 36 Noise (db(a)) H/M/L 37/33/30 37/33/30 46/44/41 46/44/42 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDEC071H0NA YDEC080H0NA YDEC090H0NA YDEC112H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 8.0 9.0 11.2 Heating 8.0 9.0 10.0 12.5 Power Input (W) - 180 210 210 210 Current (A) Nominal 0.83 0.97 0.97 1.20 Air Flow (m3/h) - 1250 1550 1550 1950 Dimensions (mm) H W D 680 x 1245 x 240 680 x1670 x 240 Weight (kg) Net Weight 36 38 51 Noise (db(a)) H/M/L 47/45/42 52/48/46 52/48/46 52/48/46 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 30 YES Mini VRF Series

Floor-concealed Indoor Indoor Unit Model YDVC 028H0NA YDVC 045H0NA YDVC 056H0NA YDVC 071H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 4.5 5.6 7.1 Heating 3.2 5.0 6.3 8.0 Power Input (W) - 41 50 60 71 Current (A) Nominal 0.18 0.23 0.27 0.32 Air Flow (m3/h) - 420 680 900 1000 Dimensions (mm) H W D 600 x 730 x 230 600 x 980 x 230 600 x 1334 x 230 600 x 1334 x 230 Weight (kg) Net Weight 20 24 30 31 Noise (db(a)) Standard 35/32/30 35/32/30 36/33/31 37/34/32 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Note: 1. Cooling conditions: indoor 27 CDB/ 19 CWB, outdoor 35 CDB, equivalent length 10m, IU/OU height difference 0m. 2. Heating conditions: indoor 20 CDB, outdoor 7 CDB/6 CWB, equivalent length 10m, IU/OU height difference 0m. 3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per different installation and working conditions. YES Mini VRF Series 31

Notes 32 YES Mini VRF Series

Notes YES Mini VRF Series 33

2013 Johnson Controls, Inc. w w w. j o h n s o n c o n t r o l s. c o m PUBL-6969