What do these items have in common?

Similar documents
NFPA31FuelOilPiping 1 Revised

Boiler & Pressure Vessel Inspection discrepancies and failures

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Boiler Preparation, Start-Up and Shutdown

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

I. STEAM GENERATION, BOILER TYPES

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Steam System Best Practices Condensate System Piping

Factory owners must ensure the boiler is:

ASME B31.3 Process Piping. Scope of B31.3 Course

HOT WATER SYSTEMS CONTENTS

Heating Water by Direct Steam Injection

SIOUX HYBRID WATER HEATER

The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Hi-R-Temp Installation Manual

Course available 24/7 for up to six months from the date of purchase or until completion

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

OTF Oil Fired Pool Heater

ENGINE COOLING SYSTEM

Evaluate, Clean, and Tune Guidance

Boiler and Burner Cleaning and Servicing Specifications

Steam System Efficiency. Bill Lumsden Leidos Engineering

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Steam Coil Installation, Operation and Maintenance

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Ethanol Vehicle and Infrastructure Codes and Standards Citations

C. starting positive displacement pumps with the discharge valve closed.

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Commercial Gas Water Heaters

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

300 Series PA Pump and Cooler Assemblies

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Energy Efficient Operations and Maintenance Strategies for Boilers

Routine and Emergency Boiler Operation

?52. Questions. and their. Answers, Relating To Hot Water Safety

5.2. Vaporizers - Types and Usage

steam centre of excellence Steam Boiler System Optimization

Printing and Publishing Energy Savings Guide

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Indirect fired heaters

HS-901(A) BASIC STEAM HEATING SYSTEMS

ASME Packaged Indirect Fired Water Heater

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Float and Thermostatic Traps Series H, C and X

FILLING AND PURGING THE SYSTEM

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

BOILER ROOM GUIDE. Reference Guide

Attachment J-C18.1. HVAC Work Instructions

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

T&P and ASME Safety Relief Valves

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

TABLE OF CONTENTS THE WATERTUBE BOILER REGULATORY CODES ECONOMIZERS BLOWDOWN SEPARATOR...1-8

PACKAGED FIRE TUBE BOILER

ADMINISTRATIVE SERVICES MANUAL

IGEMA BOILER LEVEL & TDS CONTROLS

2010 Residential Water Heater Replacement Check List

Oil and Coolant Circulating Heating System. Model - OCSM

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

Morrison Bros. Co. General Product Specifications

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Notes. Material 1. Appropriate Flammable Liquids

Preventing Overheated Boiler Incidents

Energy Saving Fact Sheet Boilers

BOILER CLASS 5, 5A/5B LICENSE EXAMINATION STUDY GUIDE

Electric Water Heater

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

FLASH TANK ECONOMIZER PRODUCT GUIDE

CHAPTER 5 WATER HEATERS

TABLE OF CONTENTS INSTALLATION & OPERATING INSTRUCTIONS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

North Dakota State Fire and Tornado Fund Providing affordable property insurance coverage for the state and its political subdivisions since 1919.

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Steam System Design and Best Practices Related to Kiln Drying

IMPORTANT SAFETY NOTICE

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

EVALUATING SCHOOL BOILERS: BEST REPLACEMENT OPTIONS

Tankless Water Heater

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Condensing Boiler Efficiency

Service Manual Models: 502, 752, 1002, 1302,

Transcription:

What do these items have in common?

Overview of Thermal Fluid Heaters 83 rd General Meeting of the National Board Presented by Melissa Wadkinson, PE

Purpose Compared to Power Boilers and Heating Boilers, there are a limited number of installations of thermal fluid heaters. Minimal guidance is available on these heaters and systems. Jurisdictions vary in how these heaters and systems are regulated.

Overview Description of a thermal fluid system Comparison of thermal fluid to steam Critical system components System and safety considerations Installation Codes and Standards

What is a thermal fluid system? Thermal fluid (also known as hot oil) systems may be liquid or vapor. Vapor phase systems may either incorporate a heater in which vaporization of the fluid takes place within the vessel, or a flooded heater where the fluid is vaporized externally through a flash drum. Vapor systems with condensing vapor provide a uniform heat source than liquid phase systems. A liquid phase thermal fluid system uses a flooded pressure vessel (heater) in which the heat transfer media (fluid) is heated but no vaporization takes place within the vessel. Closed loop systems which may be open or closed to the atmosphere Similar in concept to hot water boiler systems

Vapor Phase System

Typical Hot Oil Heat Transfer System Designed to Operate at Atmospheric Pressure

Design Features Heaters are commonly direct-fired by combustion of a fuel, or electric resistance elements can be used. Heater design may be similar to a fire-tube boiler, electric resistance heated boiler, or a water tube boiler. Heaters may operate at temperatures up to 750⁰F depending on the process requirements and fluid selection. Large heaters may be field erected; however, heaters less than 30,000,000 BTU/hr are similar to packaged boilers utilized in a variety of process applications and may be found in typical boiler room installations.

Thermal Fluid Heaters

Why use thermal fluid instead of steam? No corrosion or freezing concerns Simple circuit; no blow downs, steam traps, or condensate return systems Minimal maintenance No hand-hole gasket replacement No re-tubing No water treatment requirements High operating temperatures obtained with minimal system pressures (system pressure drop only). If a process requires heating and cooling, it may be done with a single fluid.

Hot oil can be utilized with the following types of equipment: Steam / Hot Water Generators Storage Tanks

Hot oil can be utilized with the following types of equipment: Baths / Kettles Rolls Reactors

Hot oil can be utilized with the following types of equipment: Presses, Molds and Platens Fryers Ovens

Applications using thermal fluid heaters

System Components A typical thermal fluid system is comprised of four main components: Thermal fluid heater Thermal fluid circulating pump Expansion tank User

System and Safety Considerations Thermal fluid selection Pump and proof of flow Fluid excess temperature protection Stack excess temperature limit Expansion tank design and fluid level

Thermal Fluid Selection Any fluid specifically designed for heat transfer use may be considered. Lubricating or hydraulic oils are not acceptable. Fluids must have physical property data at elevated temperatures. Factors to consider include: Maximum recommended bulk temperature System operation should never exceed the maximum bulk temperature of the fluid. Minimum operating temperature. Is cooling required? Minimum start-up temperature. Outdoor or indoor application.

Thermal Fluid Selection Vapor pressure/boiling point Special construction requirements if the operating temperature exceeds the boiling point. Some common thermal fluids include: Dow Dowtherm A, G, RP Monsanto Therminol 55, 59, 66 Paratherm NF, HE Petro Canada Calfo AF, Purity FG

Thermal Fluid Maintenance Fluids should be tested annually. Lubricating oil tests that include dissolved metals are not adequate. Do not top off with different thermal fluid chemistry. Mineral oil/petroleum vs. synthetic/aromatic. Track heater inlet and outlet temperatures and pressures. Always record the date and the amount of fluid addition. Changing the type of fluid used in a system may require a change in the system components (pump, expansion tank etc.). Chemical cleaners may also be required.

Thermal Fluid Pump Must be designed for use with thermal fluids at temperature Standard hot water and boiler feed pumps are not appropriate. Pumps may be air cooled, water cooled, canned or mag drive designs. The pumps are sized to overcome the pressure drop in the system and must be sized based on the specific gravity of the fluid at operating temperature.

Proof of Fluid Flow Proof of fluid flow is critical for vessel longevity and system integrity. Means should be provided to prove minimum fluid flow through the heater at all operating conditions to ensure proper velocities and film temperatures. A low flow condition can cause overheating, degradation of the fluid, or heater coil/tube failure. Proof of flow is typically interlocked into the combustion circuitry Means to prove flow may include vortex shedding meters, flow switches, pressure switches, an orifice or a differential pressure switch.

Fluid Excess Temperature Protection This limit prevents the fluid temperature from exceeding the maximum allowable temperature of the specific fluid. It should be set no higher than the maximum bulk temperature of the fluid. The temperature sensing device should be compatible with the fluid and the system operating temperature and pressure and located at the heater outlet. It is generally interlocked into the combustion safety circuitry and often incorporates a manual reset functionality.

Stack Excess Temperature Limit Many installations include a high stack temperature switch interlock. In the event of a high stack temperature this device shuts off the burner and circulating pump. The manufacturer of the heater determines the acceptable stack temperature for the heater. A high stack temperature indicates improper combustion (or soot build up) or a failed coil. Manual reset is recommended. The stack limit may be part of an inert gas smothering system.

Expansion Tank Design Fluid selection, system volume and operating temperature will impact expansion tank size. Depending on the fluid selection and operating parameters, systems may be open or closed to the atmosphere. Closed systems may be pressurized with an inert gas blanket. An ASME tank may be required.

When should a pressurized expansion tank be used? The tank is not the highest point in the piping system. The tank contents can be at a temperature such that exposure of the fluid to the air would cause degradation of the fluid. The fluid is operated above its atmospheric boiling point. The fluid manufacturer recommends the use of an inert blanket.

Expansion Tank Fluid Level A minimum liquid level must be maintained in the expansion tank to prevent pump cavitation. A liquid level switch or similar device is typically provided and interlocked with the pump and burner to shut them down in the event of a low fluid level condition. The switch should be satisfied before the pump can start.

Installation Combustion air and ventilation requirements are similar to those of power or heating boilers and determined by the manufacturer. A containment curb or seal welded drip lip on the heater skid should be considered. Piping, valves and system components are rated for the temperature and pressure of the system Brass, bronze, aluminum and cast iron components are not recommended. Any sign of leaking piping is a safety concern, as the fluid or its vapors can be hazardous or flammable. Piping should be welded or flanged where possible and pneumatically tested for leaks.

Installation Pressure relief devices The pressure relief valves should be a totally enclosed type with no lifting lever. The discharge piping of the pressure relief valve should be connected to a closed vented storage tank. Insulation The insulation should be selected for the intended purpose. Where there is a potential for fluid leaks, the insulation should be non-absorbent.

Codes and Standards Jurisdictions have varying requirements for thermal fluid systems. Until recently, limited guidance has been available. What resources are available? National Board Inspection Code ASME Boiler Pressure Vessel Code Controls and Safety Devices for Automatically Fired Boilers National Fire Protection Association, NFPA-87

National Board Inspection Code (NBIC) The NBIC Part 2 Inspection provides some information on thermal fluid systems. Part 1 of NBIC Installation covers the requirements for power boilers, heating boilers, and pressure vessels. There is an open item to provide guidance for the installation of thermal fluid heaters as a new supplement to Part 1. Requirements such as clearances, ladders, electrical, ventilation and combustion air are consistent with steam boilers, hot water boilers and other pressure vessels. Additional requirements regarding expansion tanks, pumps, piping and controls are included.

ASME Boiler and Pressure Vessel Code Some Jurisdictions may require ASME Section I or ASME Section VIII Div. 1 construction. The specific requirements outlined in the construction codes must be met.

ASME Section I Requirements Organic Fluid (thermal fluid) Vaporizers Rules in Part PVG are applicable and are used in conjunction with the general requirements of Part PG. Part PVG addresses the pressure relief valves, gage glasses and drain valves. Liquid phase thermal fluid heaters Applicable requirements for liquid phase heaters are not clearly identified. There is an open item in progress to define the Section I rules for these heaters.

ASME Section VIII Div. 1 Requirements Subject to Paragraph UW-2(d) for pressure vessels subject to direct firing. Category A welds must be in accordance with Type No. (1) of Table UW-12. Welded joints in Category B (for thicknesses exceeding 5/8 ) must be Type No. (1) or No. (2) of Table UW-12. Post weld heat treatment may be required depending on the material used and weld size. Stamping of the pressure vessel shall include DF for direct firings and the Manufacturer s Data Report will indicate the special service requirements. Safety relief valves may be based on the flow through the heater, operating temperature, fluid and set pressure.

Controls and Safety Devices for Automatically Fired Boilers (CSD-1) CSD-1 applies to Power Boilers and Heating Boilers with inputs less than 12,500,000 BTU/hr. It includes requirements for combustion controls as well as steam and waterside control (including pressure, temperature and water level). With the current Standard, questions exist regarding the applicability of CSD-1 to thermal fluid systems. Combustion controls covered in CSD-1 are applicable to thermal fluid heaters. However, Part CW, Steam and Waterside Control, does not cover the requirements for thermal fluid systems. A task group was formed in CSD-1 to review and define the specific requirements for thermal fluid systems.

National Fire Protection Association, NFPA-87 While NFPA 85 (boilers) and NFPA 86 (ovens) provide excellent information regarding combustion controls, neither Standard was directly applicable to thermal fluid heaters. Recommended Practice for Fluid Heaters, NFPA 87, was developed. Topics covered include: Location and Construction Heating Systems Commissioning, Operations, Maintenance, Inspection and Testing Heating System Safety Equipment and Application (combustion & temperature control) Chapters specific to thermal fluid heaters (pumps, expansion tanks etc.) Fire Protection

In Summary, Thermal Fluid Systems Obtain high temperatures with low system pressures Are commonly used in a variety of applications Design/safety considerations include: Fluid, flow and temperature Codes and Standards are under development to provide additional guidance