REIHE INFORMATIK 15/95. A High Quality Lithograph with Integrated Environment for Computer Generated Holograms

Similar documents
Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Encoders for Linear Motors in the Electronics Industry

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Module 13 : Measurements on Fiber Optic Systems

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Optical Metrology. Third Edition. Kjell J. Gasvik Spectra Vision AS, Trondheim, Norway JOHN WILEY & SONS, LTD

Neuro imaging: looking with lasers in the brain

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Microlenses immersed in nematic liquid crystal with electrically. controllable focal length

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Physics 441/2: Transmission Electron Microscope

Introduction to Fourier Transform Infrared Spectrometry

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

tesa scribos Security Solutions Good for Partners, Good as Partner

Microscopy: Principles and Advances

Imaging techniques with refractive beam shaping optics

Introduction to Optics

Color holographic 3D display unit with aperture field division

Lecture 14. Point Spread Function (PSF)

Raman spectroscopy Lecture

Modern Classical Optics

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

WOOD WEAR TESTING USING TRIBOMETER

Single Photon Counting Module COUNT -Series

Realization of a UV fisheye hyperspectral camera

Optical Design for Automatic Identification

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Plastic Film Texture Measurement With 3D Profilometry

Synthetic Sensing: Proximity / Distance Sensors

Scanning Surface Inspection System with Defect-review SEM and Analysis System Solutions

Spot Weld Analysis with Two-Dimensional Ultrasonic Arrays

Introduction to microstructure

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES


Project 2B Building a Solar Cell (2): Solar Cell Performance

Laser expander design of highly efficient Blu-ray disc pickup head

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Acousto-optic modulator

RIEGL VZ-400 NEW. Laser Scanners. Latest News March 2009

Tube Control Measurement, Sorting Modular System for Glass Tube

Experiment 5. Lasers and laser mode structure

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Lab 9: The Acousto-Optic Effect

Sensori ottici e laser nelle applicazioni industriali

Theremino System Theremino Spectrometer Technology

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

How To Measure Contactless Measurement On A Robot

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system

Projects. Objective To gain hands-on design and measurement experience with real-world applications. Contents

Holographic data storage at 2+ Tbit/in 2

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Tutorial Solutions. then the Amplitude transmission of a thin hologram formed from this distribution is

Rodenstock Photo Optics

DIODE PUMPED CRYSTALASER

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

Light Control and Efficacy using Light Guides and Diffusers

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Measuring the Point Spread Function of a Fluorescence Microscope

Measuring Line Edge Roughness: Fluctuations in Uncertainty

A More Efficient Way to De-shelve 137 Ba +

Fig.1. The DAWN spacecraft

The Basics of Scanning Electron Microscopy

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

Digital Holography using a Laser Pointer and Consumer Digital Camera Report date: June 22 nd, 2004

Non-Contact Vibration Measurement of Micro-Structures

A Guide to Acousto-Optic Modulators

Robot Perception Continued

SCIENCE CHINA Physics, Mechanics & Astronomy

Atomic Force Microscope

Optical Methods of Surface Measurement

AxioCam HR The Camera that Challenges your Microscope

Introduction to 3D Imaging

Signal to Noise Instrumental Excel Assignment

Application Report: Running µshape TM on a VF-20 Interferometer

Optical laser beam scanner lens relay system

FTIR Instrumentation

A System for Capturing High Resolution Images

Adaptive Optics Testbed for the Visible High Resolution Imaging

Optical Coherence Tomography OCT. 3D Imaging in Medical Technology and Quality Control

Hanover Center for Optical Technologies - HOT


Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Diffraction and Young s Single Slit Experiment

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Enhancing the SNR of the Fiber Optic Rotation Sensor using the LMS Algorithm

Understanding astigmatism Spring 2003

5.3 Cell Phone Camera

Transcription:

REIHE INFORMTIK 15/95 High Quality Lithograph with Integrated Environment for Computer Generated Holograms S. Noehte, C. Dietrich, G. Fischer, P. Großkopf, R. Lange, R. Männer, E. Zhang Universität Mannheim Seminargebäude 5 D-68131 Mannheim

HIGH QULITY LITHOGRPH WITH INTEGRTED ENVIRONMENT FOR COMPUTER GENERTED HOLOGRMS Steffen NOEHTE, Christoph DIETRICH, Gunther FISCHER, Peter GROßKOPF, Rupert LNGE, Reinhard MÄNNER, Eryi ZHNG Chair of Computer Science V, University of Mannheim, Mannheim, Germany bstract This paper describes a complete development environment for the production of digital holograms, including simulation software and a lithographic system. The software allows to compute phase and amplitude holograms of Kinoform, Fresnel and Fourier type. The lithograph has a resolution of 0.4 µm and provides 1,000 grey values using s2s3 as a holographic film. Introduction The goal of our investigations is the construction of an optical neural network computer. Here the basic and most costly operation in computing time is a matrix multiplication. This operation will be realized optically using computer generated holograms (CGH). Only CGHs provide an optical imaging sufficiently good to realize the synaptic connection between the neurons. In the case of neural networks with a large number of neurons, high-quality holograms are required. For their production three conditions have to be met. First, digitalization algorithms are required which both provide an sufficient reproduction quality and are efficient enough to calculate large CGHs. In respect to the complexity of the task a user-friendly test environment must be available. These are provided by the program package DIGIHOL developed by us. Second, the computed holograms have to be exposed with high resolution (<1µm), a greyscale resolution of more than 100 values, possibility as a phase holograms with good reconstruction quality. We constructed a greyscale lithograph which fulfills these requirements. Third, a proper holographic material is required. t this time we use the semiconductor glass s2s3 as holographic film. Computer Generated Holograms n extensive, user-friendly simulation program DIGIHOL was developed to calculate computer generated holograms and to simulate their optical imaging. Different coding forms are available, such as Kinoform, Fresnel and Fourier holograms. The calculated reconstruction allows to detect in advance nearly all optical aberrations: Scattering light effects, distortion, reduced grey scale, non-linear effects of exposure, distortion, and many others. phase optimization for the reference beam was developed to improve the quality of holograms. The integration of the DIGIHOL program into the pattern recognition program IMGE 1) provides a complete and accurate visualization of all the calculated data. The different types of holograms we make available for calculation are shown in table I. For tests and inspections of calculated results some functions were added, for example to show the difference or correlation between two results, or the reconstructed hologram and the original. CGHs with different reference beam profiles can be calculated as zero phase, random phase, and a lens phase. Type binary greyscale amplitude hologram phase hologram different reference beam Kinoform Fresnel Fourier Table I: Possible types of CGHs which were implemented in DIGIHOL new method was developed to code grey scale holograms in binary form. The results show a good signal to noise ratio and a high diffraction efficiency in comparison to other methods. The binarization is performed gradually and randomized; by using an iterative algorithm the quantization error is distributed.

efficiency (Eta), the Mean-Square-Error (MSE), and the Signal-to-Noise-Ratio (SNR) can be calculated to compare the results of different tests. Lithographic system Fig. 1: Example for a binarized grey scale hologram based on gradual and randomized binarization with distributed quantization. The size of holograms which can be calculated depends to the available RM size and time. Normally we calculate holograms up to 2000 2000 points. s an example a 1000 1000 hologram needs nine minutes on a Macintosh Quadra 700 with 20 MB RM. Its flexibility and user-friendly surface makes DIGIHOL easy to handle. Fig. 2 shows a typical screen shot of the user surface of DIGIHOL, implemented on a Macintosh computer. The value of the chosen output amplification of the reconstructed hologram (FY), the diffraction The construction of the lithographic system is based on a scanning sample, and a fixed air-cooled r laser using the visible laser line (488nm), see fig. 3. The holographic film sample is driven by a commercial DC motor x-y actuator from Physical Instruments. The location of the micropositioners is controlled to a resolution of 100nm. fter intensive research on the focusing system we replaced the microscope lens by a commercial CD player module. n auto focus regulator using the method of "knife edge" enables a Z-stabilisation of less than 0.1µm. Different film parameters are accounted for by a built-in automatic exposure time unit based on a confocal laser microscope with a He-Ne laser to ensure proper exposure intensity. For every holographic sample a predefined installation pattern with different intensities is written by the lithograph and read out by the confocal laser microscope, see fig. 4. The analysis of the film sensivity is done by the computer. On a sample of size 2 2 cm 2 up to 100 holograms can be written. The automatic exposure control is a very important feature for holograms with analogue values for optimizing the diffraction efficiency. The confocal laser microscope can also be used for the inspection of exposured structures, as shown in fig. 5. The complete system is controlled by a Macintosh Quadra 700 computer. The software driver of the lithograph is implemented in the program DIGIHOL. From the user's point of view the lithograph can be used similar to a laser printer.

Reference Point Calibration pat tern for Sensit iveness x Probe Name y Hologr aphic Patt ern Identification No. Spot size: 0.4µm utofocus error: 0.1µm Dynamic of exposure: 1000 Laser intensity at spot: 1.7 MW Data format for printing: TIFF, PICT, RW Speed of writing:² 5000 points/sec Holographic material Hologr aphic Material Substrate Fig. 4: Predefined installation pattern on a holographic sample. The positions of all holograms are stored in a database with all important descriptions for a later identification. We used the semiconductor glass s2s3 as the holographic material. It allows an effective phase change and thus a high diffraction efficiency, combined with a high resolution (10,000 l/mm). The s2s3 film we used for synthetic holograms has a thickness of 2µm. Test pattern holograms show excellent results with high diffraction efficiencies 2). Measurements and results Fig. 5: Example of a 5µm grid recorded by a confocal laser microscope Parameters of the lithographic system: Writing area: 200 200 mm 2 Positioning error: < 0.5µm Fig. 6: s a demonstration of the accuracy of the lithographic system, the emblem of the University of Mannheim was plotted with a pixel distance of 1µm and a grey level range of three orders of magnitude. Magnetic Z-ctuator Knife-Edge Z-Regulator He-Ne-Laser Pinhole & Photodiode Prism Pockels Cell Probe mounted on an X-Y-ctuator ir cooled r -Laser Fig. 3: Schematic set-up of the lithograph

t the right side a magnification were one can see the single points. High Dynamic Range For Holographic Recording In s 2 s 3 ; Proc. Frontiers in Information Optics, Kyoto (1994) The spot size was measured with a confocal laser microscope from Leika Instruments and a atomic force microscope from the Physical Institute of the University of Heidelberg. The greyscale resolution was measured by writing grids with different intensities. The change of refractive index was indirectly measured by the diffraction efficiency. The measurement of the absolute phase shift at nano scale structures is very complicated. We are trying to reduce the error of absolute phase shift from ±10% to less than 1%. Fig. 7: Reconstruction of a hologram of size 256 256 µm 2. n example for the projection of a mini hologram with a size of only 0.25 0.25mm is given in Fig. 7. The diffraction efficiency is only 7% less than the calculated efficiency. second miniaturized version of this lithograph is planned for the future. It will have a higher writing speed and a pizzabox size including all electronics and lasers. cknowledgements Thank you very much for the very helpful FM analyses which were made by the group of Prof. Dr. R. Neumann and J. ckermann of the Physical Institute of the University of Heidelberg. We want to thank Leika Instruments, Heidelberg for the nice lasermicroscopic images. References 1) Wayne Rasband, National Institutes of Health, Research Services Branch (NIMH): IMGE 2) C.H. Dietrich, S. Noehte, R. Männer, K.K. Schwartz: Linear Phase Shift Response With