Return to Engine Exhaust Noise Control

Similar documents
3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

Exhaust noise control case study for 2800 class locomotive

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

Absorption mufflers in exhaust systems. Rolf Jebasinski. J. Eberspächer GmbH & Co. Abstract

Noise in the Classroom

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

Acoustic Terms, Definitions and General Information

Acoustical Design Guidelines for HVAC Systems in Schools

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

How To Reduce Noise From A Test Screen

General Design Principles for an Automotive Muffler

Sound Attenuation INTRODUCTION

Sound Pressure Measurement

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

The Role of Acoustics in Curtain Wall Design:

Noise Control Solutions For Standby Power Generators

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

HVAC Systems: Overview

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Basic Selection & Proper Application of Overhead Air Distribution Devices

Sound Power Measurement

Build Green Schools. Click on this link for more information.

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Relationship between Sound Pressure and Sound Power Levels

Duct Design. Presented by Dave Janquart

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Exhaust Calculation Booklet

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

Installation Instructions Hustler 6-BTV Trap Vertical

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

HVAC Acoustic Fundamentals

HVAC Calculations and Duct Sizing

DRYER VENTING SPECIFICATIONS DRYER SAFETY

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Lightweight Partition Design for Residential and Commercial Buildings

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Data Centres A complete solution to noise control and acoustic packages

Noise. CIH Review PDC March 2012

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Centrifugal Fans and Pumps are sized to meet the maximum

Inspection and Testing of Water-Based Systems

PROPAGATION OF SOUND WAVES IN DUCTS

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

Resonance in a Closed End Pipe

APPLICATION NOTE AP050830

MULTIZONE APPLICATION OF SOLUTION UNITS

FIRE DAMPER APPLICATION GUIDE

Antenna Deployment Technical Brief

ASX7-4-IOM-7 J

Development and optimization of a hybrid passive/active liner for flow duct applications

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Section 5.0 : Horn Physics. By Martin J. King, 6/29/08 Copyright 2008 by Martin J. King. All Rights Reserved.

Technical Information

TOP 10 NOISE CONTROL TECHNIQUES

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

Application Note Noise Frequently Asked Questions

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

FUNDAMENTALS OF ACOUSTICS

Sound absorption and acoustic surface impedance

PART VIII: ABSORPTIVE SILENCER DESIGN

Understanding Range for RF Devices

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Measuring of optical output and attenuation

CADB and CADT-D / DI / DC Series

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Welcome. Green HVAC Ductwork Done Right! John Reints, PE Eugene Smithart, PE

Building Energy Systems. - HVAC: Heating, Distribution -

ENGINEERING DATA. Fan Sound & Sound Ratings

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Application note for Peerless XLS 10" subwoofer drive units

Interference. Physics 102 Workshop #3. General Instructions

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Affordable Sports Halls

Understanding Power Splitters

A Study of Durability Analysis Methodology for Engine Valve Considering Head Thermal Deformation and Dynamic Behavior

Demand Based Static Pressure Reset Control for Laboratories

application note Directional Microphone Applications Introduction Directional Hearing Aids

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

plenum slot diffusers

Noise associated with the ground water systems serving residential geothermal heat pumps

Schindler 3300 / Schindler 5300 Information on noise and vibration.

Case Studies: Infrared Heating in Industrial Applications

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Broadband Slotted Coaxial Broadcast Antenna Technology

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

The CEETHERM Data Center Laboratory

product application guide

APPLICATION NOTES POWER DIVIDERS. Things to consider

Re: Wildwood, 2-6 High Street, Kingston, KT1 1EY - Proposed Restaurant - External Plant Noise Assessment - Revised

Transcription:

Return to www.enoisecontrol.com Engine Exhaust Noise Control Jerry G. Lilly, P.E. JGL Acoustics, Inc. Issaquah, WA jerrylilly@aol.com

Engine Exhaust Noise Control Reactive Mufflers Absorptive Silencers Reactive/Absorptive Mufflers Tail Pipe Design Tuned Resonators Project Examples The above are the subjects that we will discuss. Some data will also be presented from field tests: One an example of a project failure and the other a big success.

Engine Exhaust Considerations The exhaust system of a generator has several inherent design problems that must be considered. These characteristics impose severe limitations on what can be done to silence the engine exhaust noise: Very High Noise (100 to 120 dba @ 1 m) High Temperatures (950 to 1050 ο F) High Velocities (5,000 to 15,000 fpm) Combustion By-Products (soot & corrosion) Pipe Thermal Expansion

Performance Characteristics Insertion Loss (db) depends on design, size and frequency Pressure Drop (inches H 2 O or Hg) depends on velocity & design Self-Generated Noise (db ref. 1 picowatt) depends on velocity & design Insertion loss (IL) is defined as the reduction of noise level that occurs when a silencing element is inserted into the system. Because engines generate strong tonal components, the IL of any one muffler will not be the same with different engines, different loads, or different piping configurations. Pressure drop is more predictable, however. Specific data on self noise is generally not available.

Engine exhaust noise varies significantly with loading. Typically the noise level at full load is about 10 db higher than the no-load condition. The next slide shows typical engine exhaust sound levels at different loads. The curves also show that the majority of the engine exhaust noise is at low frequencies.

Unsilenced Exhaust Noise Unlike engine block noise, exhaust noise increases significantly with engine load Graph at right shows noise level vs. load for a 16-cyl. 2000 KW engine (1800 RPM diesels) Sound Pressure @ 1 m (db) 130 125 120 115 110 105 100 63 125 250 500 1000 2000 4000 8000 Octave Band Frequency (Hz) 25% 50% 75% 100%

The overall noise level from most unsilenced engine exhaust systems varies from about 110 dba to 120 dba, when measured 1 meter from the pipe outlet. The noise level does not always align with the power rating of the generator as you can see by this next graph. Exhaust noise can also be affected by engine turbochargers and after-coolers. It is best to obtain exhaust noise data from the engine manufacturer.

Unsilenced Exhaust Noise Unsilenced engine exhaust noise is broad-band with highest levels at low frequencies Data compares 6-cyl. 150 KW and 500 KW engines with a 16-cyl. 2000 KW engine (all 1800 RPM diesels) Sound Pressure @ 1 m (db) 130 125 120 115 110 105 100 63 125 250 500 1000 2000 4000 8000 Octave Band Frequency (Hz) 150 KW (114 dba) 350 KW (110 dba) 500 KW (113 dba) 2000 KW (120 dba)

The exhaust noise spectrum will always contain strong tones associated with the rate of cylinder firings. In 4-cycle engines each cylinder fires once every other revolution of the drive shaft. Cylinders fire once every rev in 2-cycle engines. The lowest tone is always the CFR, which is the firing rate for any one cylinder. The engine firing rate is generally the strongest tone in the exhaust spectrum.

Engine Exhaust Tones Cylinder Firing Rate (CFR) CFR = RPM/60 for 2-cycle engines CFR = RPM/120 for 4-cycle engines Engine Firing Rate (EFR) EFR = N(CFR) where N = # cylinders Harmonics of CFR and EFR

This graph shows a narrow band spectrum of the exhaust noise of a 6 cylinder diesel engine running at 1800 RPM in a 500 kw generator. The data was collected with the microphone placed 1 meter from the exhaust outlet with the engine running at full load. Note the strong tone at 90 Hz, which is the EFR. Note that the second and third harmonics are also prominent in the spectrum.

500 KW Engine Exhaust Tones Sound Pressure Level (db) 130 120 110 100 90 80 30 Hz (2xCFR) 60 Hz (4xCFR) 90 Hz (1xEFR) 180 Hz (2xEFR) 270 Hz (3xEFR) 70 25 32 40 51 64 81 101 128 161 202 255 321 404 508 640 806 1015 1277 1608 2024 2548 1/24th Octave Band Center Frequency (Hz) No Silencer, 6" Pipe (113 dba)

The most common element used to silence generator exhausts are reactive mufflers. Reactive mufflers are available in a wide range of cost and performance. The noise is reduced by forcing the exhaust air to pass through a series of tubes and chambers. Each element in the muffler has sound reduction properties that vary greatly with acoustic frequency, and it is the mixing and matching of these elements that constitutes muffler design.

Reactive Mufflers 2, 3 or 4-chamber designs All metal construction with no sound absorptive materials Maximize ratio of body diameter to pipe diameter & volume

Over the years a series of muffler grades have evolved to describe the approximate insertion loss performance for engine exhaust mufflers. The words do not necessarily imply where the mufflers should be used. Note that better quality (e.g. higher insertion loss) mufflers will be physically larger than lower quality units. Although size is not the only factor, you cannot get good acoustical performance without it.

Exhaust Muffler Grades Industrial/Commercial: IL = 15 to 25 dba Body/Pipe = 2 to 2.5 Length/Pipe = 5 to 6.5 Residential Grade: IL = 20 to 30 dba Body/Pipe = 2 to 2.5 Length/Pipe = 6 to 10 Critical Grade: IL = 25 to 35 dba Body/Pipe = 3 Length/Pipe = 8 to 10

The super-critical grade muffler generally represents the top of the line for reactive mufflers. Some manufacturers include an absorptive section to reduce high frequency sound transmission, but that is not the case for the silencer design shown in the next slide. This drawing shows a 3 chamber critical grade muffler. It achieves its super-critical status primarily from its length, as much as 16x pipe diameter.

Exhaust Muffler Grades Super Critical Grade: IL = 35 to 45 dba Body/Pipe = 3 Length/Pipe = 10 to 16

Absorptive silencers use fiberglass or other acoustic fill material to absorb noise without any reactive elements (tubes &chambers). Absorptive silencers provide very little noise reduction at low frequencies, so they should never be used as the only silencer in an engine exhaust system. The straight-through design shown here is very useful for absorbing high frequency self-generated noise created by reactive mufflers.

Absorptive (secondary) Silencers Straight through design with fiberglass shielded from the exhaust stream by perforated sheet metal Provides mostly high frequency IL with low pressure drop

Some manufacturers offer combination reactive/absorptive silencers in a single package unit. Although this sounds like a good idea, you generally will get better overall acoustical performance by using a reactive muffler followed by a separate absorptive silencer. Of course, a combination silencer may be appropriate for installations where there is not enough length in the exhaust system to fit two separate units.

Reactive/Absorptive Silencers These devices contain fiberglass shielded from the exhaust stream by perforated sheet metal Provides broad-band noise control

This graph shows the approximate insertion loss as a function of frequency for the various grades of mufflers. Note that all values are approximate since no muffler has repeatable IL performance from engine to engine. Also note how the IL performance of the absorptive silencer is best in the frequency region where reactive mufflers start to deteriorate.

Muffler Insertion Loss 50 Reactive mufflers work best at 125 Hz and 250 Hz (IL is reduced at high frequencies by self-noise) Absorptive mufflers work best at 1000 Hz and 2000 Hz Insertioin Loss (db) 45 40 35 30 25 20 15 10 5 0 Super Critical Critical Residential Industrial Absorptive 63 125 250 500 1000 2000 4000 8000 Octave Band Frequency (Hz)

The first step in generator exhaust noise control design is to determine if a single muffler (by itself) can meet the project requirements. Step 1 in this process is to obtain the unsilenced noise level from the engine manufacturer. This is typically given as sound pressure level at 1 meter (or similar distance). Step 2 is to determine the noise criteria at the receiver. Provide a 5 dba margin to allow for other sound transmission paths.

How to Select a Muffler Step 1: Unsilenced Noise Level (e.g. UNL = 116 dba @ 1 m) Step 2: Calculate Exhaust Noise Criteria ENC = RNC - 5 (dba) (e.g. to meet a total noise level of 60 dba, design muffler for 55 dba)

Step 3 is to calculate the unsilenced exhaust noise at the receiver location. The following equation provides a correction for distance assuming free-field spreading. Reflections from large objects (e.g. buildings) can cause the actual noise level to be higher than that predicted by this equation. Conversely, shielding provided by barriers (partial or total) can cause the received noise level to be lower.

How to Select a Muffler Step 3: Correct UNL to Receiver Distance L p (x r ) = L p (x 0 ) - 20 log (x r /x 0 ) for example: L p (25 m) = L p (1 m) - 20 log (25/1) L p (25 m) = 116-28 = 88 dba

In Step 4 the required insertion loss of the muffler is determined by subtracting the receiver noise criteria from the unsilenced receiver noise level. Note that a 5 db safety factor is recommended to account for the fact that actual muffler performance often falls short of the manufacturer s claims. Once a muffler grade is determined, the last step is to size the inlet/outlet pipe for pressure drop.

How to Select a Muffler Step 4: Required IL = UNL - ENC + 5 IL = 88 dba - 55 dba + 5 = 38 dba (super critical grade required) Step 5: Select inlet/pipe size for pressure drop no more than 50% of maximum

Octave band IL data must be used to compute the expected noise level if barriers are involved in the sound transmission path. If barriers are not involved, it is much simpler to use the approximate dba attenuation figures available from a reputable manufacturer. Keep in mind that octave band values are approximate because they vary from engine to engine and also with load.

Using Octave Band IL Data Octave band IL data must be used to assess effects of barriers Accuracy is probably no better than the dba method (without barriers) Manufacturer s octave band data are listed as typical because they are inconsistent from engine to engine

This graph presents the results of an insertion loss field test, where the contractor wanted to substitute a less expensive muffler from an offbrand manufacturer. Even though the manufacturer guaranteed that his muffler would meet the IL of the specified unit, it failed at nearly every octave band. The overall noise reduction was only 18 dba with the initial test shown here.

Insertion Loss Field Test Off brand muffler was substituted, but was guaranteed Muffler failed the field test repeatedly After 2 years of testing & re-testing the specified muffler was finally installed Insertion Loss (db) 40 35 30 25 20 15 10 5 0 63 125 DIL = 18 dba 250 500 1000 2000 4000 8000 Octave Band Frequency (Hz) No Load Full Load Spec

One aspect of the engine exhaust system acoustical design that is often overlooked is the tail pipe. The section of pipe downstream of the final silencer will have acoustic resonances that can amplify engine tones if they match. Resonances can be avoided simply by keeping the length of the tail pipe less than 1/2 wavelength at the tone frequency. Even better, size the tail pipe to exactly l/4 to cancel the tone. `

Tail Pipe Design Exhaust tail pipe will have resonances that can amplify engine tones Avoid amplification of tones by using short tail pipe or size L to 1/4 wavelength (λ/4) Tail Pipe L Muffler

The next equation will give you the various resonance frequencies of any exhaust tail pipe. The number n is any positive integer, but usually it is only the low frequencies that are a concern. Note that resonance occurs when L = nl/2, so this tail pipe length should be avoided at all times.

Tail Pipe Resonances where: f n = nc/(2l) Tail Pipe f n is resonance frequency of pipe n = 1, 2, 3, c is speed of sound L is length of pipe (ft) resonance occurs if L = nλ/2 L Muffler

This example goes through the various steps required to design a tail pipe for a 4-cycle engine. The frequencies to avoid are 15 Hz, 30 Hz, 45 Hz, 60 Hz, 75 Hz, 90 Hz, 105 Hz, etc. The most important frequency is the 90 Hz EFR. The wavelength at 90 Hz is 20 feet, so we want to avoid a tail pipe length of 10 feet, 20 feet, 30 feet, etc. The best length is exactly 5 feet because this will cancel the 90 Hz tone at the outlet.

Tail Pipe Design Example 6 cylinders @ 1800 RPM (950 o F) CFR = (1800/120) = 15 Hz EFR = 6(CFR) = 90 Hz c = 49.03(460+950) 0.5 = 1841 ft/sec λ CFR = 1841/15 = 122 ft λ EFR = 1841/90 = 20 ft Tail Pipe Length = 20/4 = 5 ft (or 15 ft)

Tuned resonators can be used to attenuate specific frequencies in the exhaust spectrum. There are a lot of different resonator designs, but the simplest and easiest to understand is the side branch resonator, sometimes called the 1/4 wave resonator. A side branch resonator is nothing more than a dead-end section of pipe connected to the main exhaust pipe.

Tuned Resonators Resonators can be used to remove tones from the exhaust spectrum Sketch shows a side branch resonator tuned to 1/4 wavelength (λ) L Muffler λ/4

The diameter of the side branch should be equal to the diameter of the main pipe. As the acoustic wave from the source reaches the branch, the energy splits equally. The wave travelling down the side branch reflects off the closed end and is reflected back toward the branch. When it arrives back at the branch it is exactly 180 degrees out of phase from the source wave because the branch has a length of l/4.

Side Branch Resonator λ/4 Wavelength, λ = c/f Speed of Sound, c Frequency, f (Hz) Side branch is dead end pipe (no flow) Length of pipe is tuned to λ/4 or 3λ/4 Speed of sound increases with temp. c = 49.03(T R ) 0.5 (ft/sec) T R = 460 + T a ( ο F)

Side branch resonators are effective only at low frequencies and only in three narrow frequency regions. Side branch resonators are inconsequential at other frequencies. Problems inherent with the side branch resonator include de-tuning caused by changes in the speed of sound as the engine warms up. In engine exhaust systems, soot buildup and water collection in the side branch can also degrade the attenuation.

Side Branch Resonator Only effective at low frequencies (when λ > 10 times pipe diameter Only effective in 3 narrow frequency regions (L = λ/4, 3λ/4, and 5λ/4) Can achieve 20 to 30 db insertion loss if tuned properly May become ineffective if end of pipe does not remain reflective

Another resonator design that is particularly suited for engine exhaust systems is the Herschel-Quincke tube, which I like to call the trombone resonator. Acoustically, it works very much like the side branch resonator - except that it doesn t require a reflection. The only difference is that you have to consider the effects of flow velocity on the speed of sound for proper tuning.

Trombone Resonator (Herschel-Quincke Tube)

This drawing shows a floor plan of the generator room in a field application using a trombone resonator in a 2 MW generator installation on the ground floor of an office building. In order to obtain the necessary vertical space, the ground floor slab was depressed 4 feet in the vicinity of the generator. A custom fabricated acoustic transition followed by 7 ft. long duct silencers controlled the radiator and engine noise.

Resonator Field Application

The trombone resonator was designed to eliminate the 240 Hz engine firing rate of the 16- cylinder diesel. The other two resonator frequencies were 80 Hz and 400 Hz.

Trombone Resonator Design Tuned for EFR = 240 Hz (3λ/4) Also effective at λ/4 = 80 Hz and 5λ/4 = 400 Hz Gas Flow Rate = 16,745 CFM Gas Temperature = 946 o F Speed of Sound = 1,838 ft/sec Additional Loop Length = 138 inches

After completion of the acoustical design, the owner decided to incorporate a 1MW load bank between the radiator discharge and the acoustical transition. This worked very well from an acoustical standpoint because no additional noise control was required for the load bank.

Engine, Radiator & Load Bank

This next slide is a view of the trombone resonator (note the super-critical primary muffler on the left). The exhaust pipe and muffler are insulated and externally wrapped for thermal purposes. Acoustical panels with perforated metal facing are also visible on the slab above.

Trombone Resonator

Dual Air Intake & Muffler View of the dual air intake filters with the primary muffler behind. This particular engine has dual 8 exhaust outlets.

Secondary Silencer & Elbow View of the secondary silencer as it passes through the generator room wall. The exhaust then makes an elbow up followed by two additional elbows before exiting the discharge plenum.

These are views of building exterior showing the ground level radiator outlet with the exhaust outlet above.

This next graph shows the measured exhaust noise levels 1 meter from the exhaust outlet with the generator running at 50% load. Using the unsilenced engine exhaust noise data from the manufacturer, We show the calculated total insertion loss of the exhaust system. Also shown is the manufacturer s estimated octave band IL data for the primary and secondary silencers.

Field Test Results (50% Load) Exhaust system achieved 48 dba insertion loss (based on factory unsilenced data) Performance was limited by self-noise at mid-frequencies 67 dba at 1 meter Insertion Loss (db) 70 60 50 40 30 20 10 0 63 250 1000 4000 Octave Band Frequency (Hz) Measured Secondary DIL = 48 dba Primary Pri + Sec

The next slide shows a narrow band spectrum of the octave band data presented in the previous slide and shows the effect of the trombone resonator. Note the dip in the curve in the vicinity of 80 Hz and 240 Hz. The fact that there is no EFR tone (240 Hz) at all is very impressive.

Measured Spectrum at 1 meter Sound Pressurel Level (db) 90 80 70 60 50 40 30 15 Hz (CFR) 30 Hz (2xCFR) 45 Hz (3xCFR) 60 Hz (4xCFR ) 90 Hz (6xCFR) 120 Hz (8xCFR) 180 Hz (12xCFR) 240 Hz (EFR) 10 13 16 20 25 32 40 51 64 81 101 128 161 202 255 321 404 508 640 806 1015 270 Hz (18xCFR) 390 Hz (26xCFR) 1/24th Octave Band Center Frequency (Hz)

Summary In most cases a reactive muffler is adequate to control exhaust In very sensitive installations add a secondary absorptive silencer (sized to 3000 ft/min) with a short tail pipe

Summary CAUTION: Do not use two reactive mufflers in series (too much self-noise) In extreme cases use super-critical primary muffler with secondary absorptive silencer plus a tuned resonator to eliminate tones Return to www.enoisecontrol.com