ACTUATOR LA30 PRODUCT DATA SHEET

Similar documents
ACTUATOR LA37 PRODUCT DATA SHEET

How To Drive A Compact Serie 1

ACTUATOR LA37 PRODUCT DATA SHEET

Focus on Building Louvres. Sun shading & comfort ventilation.

MODULAR JUNCTION BOX MJB WITH GATEWAY

Electric Rotary Actuator - On/Off or programmable control actuator

SERVOMECH Linear Actuators

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

Quick Guide for. BusLink

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

LED...A Q Series Sealed High-Intensity

Cable Plug acc. to DIN EN , Form A

QR12 (1.22 ) Diameter Optical Encoder

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Combi switchbox with integrated 3/2 way pilot valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Series 7500 Torque Sensor

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Description. Dimensions. Features. precision works better

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Electric Lifting Cylinder TV / KV 5 XE Load up to N

Conductive Level Switch FK 2 Technical Data:

Electro-Pneumatic Bus Door Control Mechanism

Series 6000 Torque measured metal bellow coupling

Kit Watt Audio Amplifier

United Kingdom Sweden Germany Switzerland USA, Canada and Mexico China Japan France Linear Units Y07 GB Asia Pacific Italy EU JUL

HERZ-Thermal Actuators

4/2-Way Pneumatic Solenoid Valve

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

POINTS POSITION INDICATOR PPI4

motion solutions for leisure, mobility and industrial applications

Pneumatic actuators The Original! Technics of the top class.

48 SERIES Relay interface modules 10 A

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

49 Series - Relay interface modules A. Features

7000 Series Buccaneer

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Displacement encoders

Chemical resistance Accidental

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

CAN BUS INTERFACE. Module Information

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

ATL Fuel Level Sender Probes

Electronic Pressure Switch EDS 300

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Know-how makes the difference. Electrical Actuators

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Linear Actuator. Literature.


Industrial VRS Magnetic Speed Sensors

GROENEVELD AUTOMATIC GREASING SYSTEMS

Telefon (+45) Telefax (+45) Installation and operating manual

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

Inwall 4 Input / 4 Output Module

Unit 24: Applications of Pneumatics and Hydraulics

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

D.C. Motors. Products and specifications subject to change without notice.

Points Position Indicator (PPI1) for Points Motors with Common Ground

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Mechanical Cylinders

ABB Drives. User s Manual HTL Encoder Interface FEN-31

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Shunt lock function 3066

Plug and Socket Devices CES 63 A Series 8579

Horns. Buzzers , Compressed air horns Disc-type horns Electric twin-tone horns 6.08

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Piston rod cylinder Tie rod cylinder Series 167. Brochure

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Rotary actuators Rotary wing drives Series RAK. Brochure

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

EFC Frequency converters

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

PUSH BUTTON START INSTALLATION MANUAL

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Assisted lift operated 2/2-way solenoid valves Type EV250B

Mounting and System Description for SSZ-Safety-Mats

intelligent solutions

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Inductive sensor NI10-M18-Y1X-H1141

Signal Tower modulsignal50

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Absolute Rotary Encoder E6CP

SYSTEM 45. C R H Electronics Design

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Digital input modules

LVDT. Inductive Position Transducer. SM Series. Key-Features:

How To Build A Low Voltage Capacitor Lvcp

Plug and Socket Devices SolConeX 16 A Series 8570

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

photoelectric highlights

Transcription:

PRODUCT DATA SHEET ACTUATOR LA3 Features: 12/24V DC permanent magnet motor Max. thrust up to 6 N (LA3LK) Stainless steel piston rod Elegant and compact construction with small installation dimensions Protection class: IPX / IP66 Colour: black Speed max. 65 mm/s (LA3 S-motor with 12 mm pitch) Low noise level Steel construction for all bearing parts Acme thread spindle for optimum efficiency Options: Extra powerful motor (S-motor) L-motor for system actuator IP66 (by ordering LA3 with plastic housing) Double-acting brake - increased self-locking ability (LA3 with 6 or 9 mm pitch LA3 S-motor with 6 or 9 mm pitch and LA3L) which ensures that all these types are fully self-locking Potentiometer for positioning the actuator -1 K ohm, -5 K ohm or -1 K ohm Reed switch (only LA3 L-motor versions): 8 pulses pr. spindle revolution Mechanical spline function. Safety feature by using the mechnical spline, the actuator can only push Safety nut (only in push) Terminal cover (only LA3 L-motor versions) Ball screw (K) (only LA3 L-motor versions) s) Ball screw and safety nut (KAS) (only LA3 L-motor versions) Ball screw, safety nut and splines (KSM) (only LA3 L-motor versions) Usage: Duty cycle: Max. 1% or 6 min/hour at continuous use Ambient temperature 5 to 4 C Storage temperature -4 to 7 C Compatible with control boxes CB8, CB12, Should LA3 be used with a non LINAK control unit, please ask the nearest LINAK representative for further details LA3 is a powerful actuator yet small enough to fit to most applications. The actuator can be supplied with options such as built-in potentiometer for servo operation or an extra powerful motor for increased speed and strength (S-motor). In addition to industrial and agricultural applications, the actuator is also ideal for positioning satellite dishes.

Dimensions: 2 turned 9 o 1 Standard 1 Standard 2 turned 9 o Drawing no.: LA31C LA3 with housing mounted with LSD (protection class IPx4) Drawing no.: LA3LSD1B Installation dimension: LA3 L-motor LA3 LA3 S-motor with 3 or 6 mm pitch LA3 with spline LA3 S-motor with 9 mm pitch LA3 with brake LA3 S-motor with 3 or 6 mm pitch with brake LA3 with ball screw and L-motor / LA3 ball screw and safety nut LA3 L-motor with brake LA3 S-motor 9 or 12 mm pitch with brake LA3 L-motor with ball screw, safety nut and spline S 156 mm S 167 mm S 189 mm S 194 mm S 199 mm S 251 mm

LA3 Ordering example: 3 1 1-2 5 Cables: Protection class: General tolerance /- 7 mm N = No cable when IPX (except reed) = Straight with jack plug 23 mm 1 = Straight with jack plug 15 mm 2 = Coiled with jack plug 4 mm 3 = Coiled with jack plug 2 mm 4 = Straight without plug 5 mm (Potentiometer) 5 = Straight without plug 12 mm (with IP66 housing) X = Other cable/length = IPX 2 = IP66 with plastic house Motor: = 24 V DC 1 = 24 V S-motor 2 = 12 V S-motor 4 = 24 V L-motor for LINAK control boxes 5 = 12 V motor 7 = 36 V motor Stroke length: Install. dim.: Options: Colour: Options: Options: XXX = mm = Standard X = Other installation dimension - = Black = None P = Potentiometer 1 Kohm L = Potentiometer 5 Kohm T = Potentiometer 1 Kohm R = Reedswitch Max. with 3 & 6 mm pitch 4 mm Max. with 9 & 12 mm pitch 5 mm = None 1 = Safety nut 4 = Brake 2 = Steel spline 5 = Brake with safety nut 3 = Steel spline with safety nut = None 1 = LSD 2 = LS Min. 5 mm Back fixture: Spindle type: Actuator type: 1 = Standard (1) 2 = Turned 9 o (2) 1 = 3 mm 2 = 6 mm 3 = 9 mm 4 = 4 mm 5 = 2.5 mm 6 = 2 mm 7 = 12 mm K = Ball spindel LA3 (1-tread) (2-tread) (3-tread) (2-tread) (1-tread) (1-tread) (4-tread) Old type no. LA3.1 LA3.2 LA3.3 LA3.4 LA3.25 LA3.2 LA3.4 LA3K Please note when standard stroke lengths are ordered together with LS / LSD the actuator stroke length will typically be 6 mm shorter and the installation dimension 3 mm longer.

Speed and current graphs: LA3 24V motor current v s load 8 7 12mm 6 5 4 3 2 1 5 1 15 2 25 3 35 Speed mm/s LA3 24V motor speed v s load 6 5 12mm 4 3 2 1 5 1 15 2 25 3 35 LA3 24V S-motor current v s load 12 12mm 1 8 6 4 2 5 1 15 2 25 3 35 4 Speed mm/s LA3 24V S-motor speed v s load 7 6 12mm 5 4 3 2 1 5 1 15 2 25 3 35 4 6 5 4 3 2 1 LA3 24V L-motor current v s load 12mm 4mm Ball screw 1 2 3 4 5 6 7 Speed (mm/s) 3 LA3 24V L-motor speed v s load 25 12mm 2 15 1 4mm Ball screw 5 1 2 3 4 5 6 7 LA3 12V motor current v s load 16 12mm 14 12 1 8 6 4 2 5 1 15 2 25 3 35 4 Thrust (Nm) Speed mm/s LA3 12V motor speed v s load 6 5 4 12mm 3 2 1 5 1 15 2 25 3 35 LA3 12V S-motor current v s load LA3 12 24V S-motor speed v s load 25 2 12mm 15 1 5 5 1 15 2 25 3 35 4 Thrust (Nm) Speed mm/s 7 6 5 12mm 4 3 2 1 5 1 15 2 25 3 35 4

Technical specifications: New type Spindle pitch Thrust max. Push Thrust max. Pull *Self-lock max. With/ without Typical speed / full load Stroke length Typical amp. at full load (mm) (N) (N) brake (N) (mm/s) (mm) 12V 24V 37xx-4xxxx/5xx 12 1 1 1/ 48/24 5 1 15 2P 25 3 35 4P 14 7 33xx-4xxxx/5xx 9 15 15 15/4 42/2 5 1 15P 2 25 3P 35 4 14 7 32xx-4xxxx/5xx 6 2 2 2/5 18.5/14 5 1P 15 2P 25 3 35 4P 14 7 31xx-xxxxx/5xx 3 3 3 3/3 16/9 5P 1P 15 2P 25 3 35 4 14 6.4 37xx-4xxxx1/2xx 12 1 1 1/ 65/35 5 1 15 2P 25 3 35 4P 2 1 33xx-4xxxx1/2xx 9 18 18 18/ 52/25 5 1 15P 2 25 3P 35 4 2 1 32xx-4xxxx2xx 6 2 2 2/5 34/2.3 5 1P 15 2P 25 3 35 4P 18-32xx-4xxxx1xx 6 24 24 24/5 34/2.3 5 1P 15 2P 25 3 35 4P 9 31xx-xxxxx1/2xx 3 35 3 35/35 17/9.5 5P 1P 15 2P 25 3 35 4 18 9 37xx-4xxxx4xx 12 1 1 1/ 26/2 5 1 15 2P 25 3 35 4P - 2.5 33xx-4xxxx4xx 9 2 2 2/ 2/13 5 1 15P 2 25 3P 35 4-4.4 32xx-4xxxx4xx 6 3 3 3/2 13.8/7 5 1P 15 2P 25 3 35 4P - 4 31xx-xxxxx4xx 3 4 3 4/4 7/4.5 5P 1P 15 2P 25 3 35 4-5.5 3Kxx-xxxx4xx 4 6 3 6/n/a 8.7/5.5 - - 15 2 25 3 35 4-4.7 3Kxx-1xxxx4xx 4 6 3 6/n/a 8.7/5.5 - - 15 2 25 3 35 4-4.7 3Kxxo-3xxxx4xx 4 6 3 6/n/a 8.7/5.5-1 15 2 25 3 35 4-4.7 The above measurements are made with the actuators connected to a stable power supply, LA3 L-motor versions with a CB12. S = Strong motor; L = Slow motor; K = Ball screw; KAS = Ball screw, safety nut; KSM = Ball screw, safety nut, spline. All stroke lengths marked with P give full resolution with the standard potentiometer (1; 5 or 1Kohm). A potentiometer may be used with other stroke lengths but will not give full resolution. LA3 Actuator with potentiometer LA3 Actuator with optical encoder Black Blue Brown Red / Yellow Green / White Red / Yellow Green / White Out going In going LA3 Actuator with reed (only possible with 24V L-motor) 3.9 k Pulse Brown Black Out going In going Blue Black Brown Green Yellow Black Red Pulses Earth 5V DC Optical encoder Blue Please note that the voltage level og feedback signal depends on the actuator load.

Thrust v s Duty cycles for LA3 3 mm pitch Duty Cycle v's Load - LA3 L-motor, 3 mm pitch (24 V) Thrust v s Average cycles for LA3 3 mm pitch Average Cycles v's Load - LA3 L-motor, 3 mm pitch (24 V) 5 4 3 2 1 % 2% 4% 6% 8% 1% 45 4 35 3 25 2 15 1 5 1 3 5 7 9 11 Average Cycles (X 1.) Duty Cycle v's Load - LA3 S-motor, 3 mm pitch (24 V) Average Cycles v's Load - LA3 S-motor, 3 mm pitch (24 V) 4 35 3 25 2 15 1 5 % 3% 6% 9% 4 35 3 25 2 15 1 5 2 4 6 8 1 12 14 Average Cycles (X 1.) Duty Cycle v's Load - LA3-3 mm pitch (24 V) Average Cycles v's Load - LA3-3 mm pitch (24 V) 35 3 25 2 15 1 5 % 3% 6% 9% 35 3 25 2 15 1 5 1 3 5 7 9 11 13 15 17 19 Average Cycles (X 1.) Thrust v s Duty cycles for LA3 6 mm pitch Duty Cycle versus Load - LA3.2L - 6 mm pitch (24 V) Thrust v s Average cycles for LA3 6 mm pitch Average Cycles versus Load - LA3.2L - 6 mm pitch (24 V) 35 3 25 2 15 1 5 % 2% 4% 6% 8% 1% 45 4 35 3 25 2 15 1 5 2 4 6 8 1 12 14 16 18 2 Average Cycles (X 1.) Duty Cycle versus Load - LA3.2S - 6 mm pitch (24 V) Average Cycles versus Load - LA3.2S - 6 mm pitch (24 V) 3 25 2 15 1 5 % 2% 4% 6% 8% 1% 4 35 3 25 2 15 1 5 3 5 7 9 11 13 15 17 19 21 23 Average Cycles (X 1.) Duty Cycle versus Load - LA3.2-6 mm pitch (24 V) Average Cycles versus Load - LA3.2-6 mm pitch (24 V) 25 2 15 1 5 % 2% 4% 6% 8% 1% 35 3 25 2 15 1 5 2 7 12 17 22 27 32 Average Cycles (X 1.) Note: The dashed lines are estimated values only.

Thrust v s Duty cycles for LA3 9 mm pitch Duty Cycle versus Load - LA3.3L - 9 mm pitch (24 V) Thrust v s Average cycles for LA3 9 mm pitch Average Cycles versus Load - LA3.3L - 9 mm pitch (24 V) 25 2 25 2 15 1 15 1 5 5 % 2% 4% 6% 8% 1% 3 8 13 18 23 28 33 Average Cycles (X 1.) Duty Cycle versus Load - LA3.3S - 9 mm pitch (24 V) Average Cycles versus Load - LA3.3S - 9 mm pitch (24 V) 2 18 16 14 12 1 8 6 4 2 % 2% 4% 6% 8% 1% 2 18 16 14 12 1 8 6 4 2 6 11 16 21 26 31 36 41 46 Average Cycles (X 1.) Duty Cycle versus Load - LA3.3-9 mm pitch (24 V) Average Cycles versus Load - LA3.3-9 mm pitch (24 V) 16 14 12 1 8 6 4 2 % 2% 4% 6% 8% 1% 16 14 12 1 8 6 4 2 3 8 13 18 23 28 33 38 43 48 53 Average Cycles (X 1.) Thrust v s Duty cycles for LA3 12 mm pitch Thrust v s Average cycles for LA3 12 mm pitch Duty Cycle versus Load - LA3.4L - 12 mm pitch (24 V) Average Cycles versus Load - LA3.4L - 12 mm pitch (24 V) 12 1 12 1 8 6 4 8 6 4 2 2 % 2% 4% 6% 8% 1% 45 145 245 345 445 545 Average Cycles (X 1.) Duty Cycle versus Load - LA3.4S - 12 mm pitch (24 V) Average Cycles versus Load - LA3.4S - 12 mm pitch (24 V) 12 12 1 1 8 6 4 8 6 4 2 2 % 2% 4% 6% 8% 1% 75 175 275 375 475 575 675 775 Average Cycles (X 1.) Duty Cycle versus Load - LA3.4-12 mm pitch (24 V) Average Cycles versus Load - LA3.4-12 mm pitch (24 V) 14 14 12 12 1 1 8 6 8 6 4 4 2 2 % 2% 4% 6% 8% 1% 4 14 24 34 44 54 64 74 Average Cycles (X 1.) Note: The dashed lines are estimated values only.

Precautions: LINAK control boxes are designed so that they will short-circuit the motor terminals (poles) of the actuator(s), when the actuator(s) are not running. This solution gives the actuator(s) a higher self-locking ability. If the actuator(s) are not connected to a LINAK control box the terminals of the motor must be short-circuited to achieve the self-lock ability of the actuator. Improved self locking ability The H-bridge ensures that the motor is shorted when the relays are incactive. This is necessary to improve the selflocking of the actuator. When using LA3 with stereo jack plug be aware of the reversed direction of travel as standard. The current supply to LINAK actuators must be cut off in case of overload when the actuators reach end position. Various other information: Noise levels: LA3: db(a) 5; LA3S: db (A) 55; LA3L: db(a) 48. Measuring method DS/EN ISO 3746, actuator not loaded. Accessories for LA3: Limit Switch There are two types of LINAK limit switches, for LA3, LS and LSD. The LSD type controls the stroke length of the actuator between two fixed end positions by cutting off the current to the motor. The LS type gives signal in two fixed end positions, but requires a control unit to stop the actuator when the micro switches are activated. Bellows Give a better protection and therefore give a higher liftetime of the actuator Protects inner tube against dust and dirt Can be used for actuators: LA3 Does not change the IP rating Available in black colour Ask for special folder Please contact your nearest LINAK dealer for further details or read more on www.linak.com. Copyright LINAK 211.1 MA M9-2-5-N. Chapter 5.7 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK.