Donn Suspension System Seismic Solutions

Similar documents
Seismic Technical Guide

Celebration Ceiling System

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1

HOW TO ESTIMATE THE COST OF T-BAR

Submittal Sheet. Product: Item# Description Unit Pack

eading Performance Solutions

Moisture Control. System Solutions to Prevent Mold

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Gridstone Gypsum Ceiling Panels

Facilities Development Division. The Building Department for California s Hospitals

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Fire protection for townhouses that share a common wall. Area Separation Wall. Systems

Key Considerations for Selecting Server Cabinets for Seismic Areas

Fire Barrier Duct Wrap 15A

FLEX by 3M Light Module System

CPA Steel Stud Framing Page 1 of 11

NEES/E-Defense Tests: Seismic Performance of Ceiling / Sprinkler Piping Nonstructural Systems in Base Isolated and Fixed Base Building

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

USG Australasia. USG Drywall Grid. Suspension System

Architect/Contractor Information Package

Calvert USA, Inc. Attic Stairs

Submittal Information

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Meeting the Fire Code with Continuous Foam Plastic Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

LP OSB Sheathing & Structural 1 Sheathing

Mortar Glass Block Installation System

Wisconsin Building Products Evaluation

Services Enclosures and Protected Shafts - Maintaining Compartmentation

MRI RF SHIELDING DESIGN

TracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA IN-42000_B

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Dock Hardware & Accessory Products Catalog

PART 1 GENERAL 1.1 SECTION INCLUDES

Bafl-Sorb Sound Absorbing Ceiling Baffles

FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

SELF-STORAGE BUILDINGS

Flexible Office Space Up to 66,240 Ft 2

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

AIR CONDITIONING PRODUCTS COMPANY

How to secure your property after a disaster

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

OAK WORKBENCH WITH 2 DRAWERS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

FlexHead commercial fire sprinkler connections. Submittal Package. The best idea in sprinkler systems since water N.Y.C. MEA # E CA: OPA-0672

WOODWORKS Linear. Assembly and Installation Instructions 1. GENERAL

EMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief

INSTALLATION INSTRUCTIONS

Code Compliant Repair and Protection Guide

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

SECTION PREFORMED METAL STANDING SEAM ROOFING

Mounting instructions for SOT78 (TO-220AB); SOT186A (TO-220F)

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Safety Grating GSSG-13R GRIP STRUT. safety grating

Partitioning & Ceiling Product Information

MIRAGE. Set-Up Instructions.

Double Coated Urethane Foam Tapes

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Connection Solutions

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x x x x600 M206, M208, M238

H-Stud Area Separation Wall System

City of San Diego, CWP Guidelines

Springlok Flashing System

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Rating when used as a weight carrying hitch without spring bars:

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

glass & Glazing Products

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

ICC-ES Evaluation Report

EcoTouch Insulation with PureFiber Technology

Mounting Details - Footpads & Brackets

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

Reinforced Concrete Slab Design Using the Empirical Method

CABLE SUPPORT SYSTEMS

SECTION STANDING SEAM METAL ROOFING

Server Chassis and Triplet Hardware v1.0

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines

9300BC SERIES Light Commercial Door Closer

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Guidelines for Earthquake Bracing of Residential Water Heaters

id led square housing FL44

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC # TESTED: MAY 23, 2008 REVISION

Art Basel Miami Beach Dec Booth Design Regulations

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

CH. 2 LOADS ON BUILDINGS

Seismic Certification Requirements For Hospital Facilities

AA Solar and Sun Power Plus

SECTION 1 GENERAL REQUIREMENTS

Guidelines for Earthquake Bracing Residential Water Heaters

Online Account Management Service The Reliant Online Account Management Service consists of the following features:

Transcription:

Certification of Performance Donn Suspension System Seismic Solutions Categories D, E, and F Category C Since 957 Donn brand suspension systems have set the standard, using the strongest gauge steel to produce the tightest systems available with the greatest lateral and torsional stiffness. Building on this commitment to quality, USG teamed with the University at Buffalo (SUNY), the Department of Civil, Structural and Environmental Engineering Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley to conduct full-scale seismic testing to evaluate and qualify the seismic performance of these systems. This testing proved that Donn suspension systems provide a superior code-compliant solution to meeting International Building Code (IBC) requirements, including installations in Categories D, E and F, and Category C. USG is the only manufacturer to team with two separate earthquake engineering laboratories to qualify the performance of our systems. When seismic requirements are a critical design issue, architects, contractors and building officials can rely on Donn suspension systems to: Meet or exceed all national code requirements with 7/8 wall molding. Fulfill requirements for IBC seismic design categories C, D, E, and F. Provide evidence of compliance (and greatly exceed) ICC Evaluation Service, Inc. (ICC-ES) C56 and C368 requirements. Offer an aesthetically attractive option to traditional 2 angle molding. Provide approved solutions certified with the maximum sq. ft. weights accommodating complete ceilings systems. Offer compliant systems tested and verified by two separate earthquake engineering laboratories. Offer a seismic clip laboratory-tested to greatly exceed all structural requirements including tension, compression and tee fallout. Seismic Specifications Seismic testing typically focuses primarily on the suspension system itself. ny ceiling panel can be installed Qualification in the test assembly regardless of how little it weighs, and components such as light fixtures and air handling equipment are usually excluded. In practical application, however, the suspension system must support and carry the weight of a fully functional ceiling system, including ceiling panels that can weigh as much as 2 lb./sq. ft. Therefore, USG tested suspension systems with weights commensurate with those found in real-world installations, including light fixtures and air handling equipment, using a wide variety of the ceiling panels that USG offers. Full-scale testing performed at the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley certifies that USG IBC-compliant assemblies are able to accommodate loads commensurate with those found in real-world installations. Maximum Ceiling System Weight Tested Teasted Load (PSF) 4.5 4.0 3.5 3.0 2.5 2.0.5.0 0.5 0.0 Category D, E & F Category C Seismic Design Category USG

The USG figures presented are based on full-scale testing and evaluation performed at the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley. Comparative data obtained from public sources includes ICC-ES Reports, product literature and Web sites. Testing complete range of USG ceiling systems was subjected to various levels of earthquake acceleration levels for the purpose of seismic qualification. The experimental studies were performed in the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley using an earthquake simulator. System performance was certified to tolerate forces in seismic Categories D, E and F that exceeded the minimum pass criterion of C56 and C368 by 42%. USG Exceeds C56 Test Criteria +42% +29% Minimum Pass Criterion Seismic Test Standard C56 Category D, E & F Category C Seismic Design Category USG Testing per ICC Evaluation Service, Inc. (ICC-ES) C56 and C368: System Design Seismic Design Maximum Ceiling llowable Suspension Test Result Category System Weight Tested System Load Carrying Capacity System DXL-H D, E, F 2.50 lbs./sq. ft. Heavy Duty Passed System DXL-I-C C 2.27 lbs./sq. ft. Intermediate Duty Passed With these certified IBC-compliant assemblies, USG is the only manufacturer to offer: seismic system that exceeds the minimum pass criterion of C56 and C368 by more than 42%. Seismic-system weights commensurate with typical ceiling systems. seismic clip laboratory-tested to greatly exceed all structural and seismic requirements including tension, compression and tee fallout. Compliant systems tested and verified by two separate earthquake engineering laboratories. 2

Code pproval Testing and evaluation performed at the University at Buffalo (SUNY), the Department of Civil, Structural and Environmental Engineering Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley qualify the performance of these systems according to the C56 Seismic Qualification Specification, and C368 cceptance Criteria for Suspended Ceiling Framing Systems. Several alternative materials, designs and methods of construction were evaluated and tested. Results of this investigation indicate that these tested alternative designs are at least the equivalent of that prescribed in the code for quality, strength, effectiveness, fire resistance, durability and safety. The data and test results presented provide technical evidence on which a code official can base approval. Construction details for these systems are shown on the following pages. 3

Seismic Test Results System DXL-H System DXL-I-C Seismic Category D, E, F C Suspension System Donn double-web, hot-dipped Donn double-web, hot-dipped galvanized steel meeting or exceeding STM C635 galvanized steel meeting or exceeding STM C635 Duty rating: Heavy Duty Intermediate Duty Wall molding: 7/8 7/8 Seismic clip: CM7 CM7 Shake Table Six degrees of freedom Six degrees of freedom Test Protocol Simulated earthquake Simulated earthquake Qualification C56 and C368 C56 and C368 Result Passed Passed Minimum cceleration Requirement Exceeds by 42% Exceeds by 29% Two djacent Floating Sides With Gap Fastener attachment to tee through slot Fastener attachment to tee through slot (optional), no fastener through wall molding (optional), no fastener through wall molding Two djacent Fixed Sides Tight, No Gap Fastener attachment to tee (optional), one fastener through Fastener attachment to tee (optional), one fastener through wall molding (optional) Perimeter Wires Yes No Stabilizer Bars No No wall molding (optional) System Weight 2.50 lbs./sq.ft. 2.27 lbs./sq.ft. Convenience holes located in the tee bulb may be used for any and all hanger wires. Load tests performed on 2-gauge hanger wires through convenience holes found the failure to be in excess of 400 lbs. This far exceeds the required 200 lbs. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. 4

Systems Summary Category D, E, F lternate Seismic pplication Standard Seismic pplication DXL-H Heavy Duty DXL-H System Heavy Duty System 7/8 Molding 2 Molding Suspension System Duty Rating Heavy Heavy Wall Molding 7/8 2 Seismic Cip CM7 None Two djacent Floating Sides With Gap CM7 seismic clip with fastener attachment to tee through No attachment of tee to molding slot (optional), and no fastener through wall molding Two djacent Fixed Sides Tight, No Gap CM7 seismic clip with fastener attachment to tee (optional), Pop-rivet attachment of tee to molding and one fastener through wall molding (optional) Perimeter Hanger Wires Yes Yes Stabilizer Bars None Yes Category C lternate Seismic pplication Standard Seismic pplication DXL-I-C Intermediate Duty System Intermediate Duty System 7/8 Molding 7/8 Molding, Stabilizer Bars Suspension System Duty Rating Intermediate Intermediate Wall Molding 7/8 7/8 Seismic Clip CM7 None (unless utilized in lieu of stabilizer bar) Floating Sides 3/8 Gap CM7 seismic clip with fastener attachment to tee through No attachment of tee to molding slot (optional), and one fastener through wall molding and one fastener through wall molding (optional) Perimeter Hanger Wires None None Stabilizer Bars None Yes ll main Donn suspension systems DX /DXL, Fineline DXF, Fineline /8 DXFF, Centricitee DXT /DXLT, CE, DXW, DXL, and ZXL include the code-compliant intermediate-duty and heavy-duty main tees for Seismic Design Categories C, D, E, and F. For ceiling areas exceeding 2,500 ft. 2 (232 m 2 ), a seismic separation joint may be required. See SC2496 for information on seismic separation joints. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. Convenience holes located in the tee bulb may be used for any and all hanger wires. 5

Categories D, E, F lternate Seismic pplication Heavy Duty DXL-H System 7/8 Molding Systems Summary Suspension System Duty Rating Heavy Wall Molding 7/8 Seismic Clip Two djacent Floating Sides Two djacent Fixed Sides Perimeter Hanger Wires Stabilizer Bars CM7 3/49 gap; CM7 seismic clip with fastener attachment to tee through slot (optional), and no fastener through wall molding. Tight, no gap; CM7 seismic clip with fastener attachment to tee (optional), and one fastener through wall molding (optional) Yes None Construction Details and 2 or 3 and 4 Tight Wall 2-gauge hanger wire CM7 seismic clip CM7 seismic clip or riveted ll main Donn suspension systems DX/DXL, Fineline DXF, Fineline /8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXL, and ZXL include the codecompliant and heavy-duty main tees for Seismic Design Categories D, E, and F. For ceiling areas exceeding 2,500 ft. 2 (232 m 2 ), a seismic separation joint may be required. See SC2496 for information on seismic separation joints. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. Convenience holes located in the tee bulb may be used for any and all hanger wires. 6 5 and 6

CM7 Clip, Tight Wall 2 8" max. 8" max. attach screw through either side (optional) +-0 6 attach screw through either top fastener opening (optional) perimeter hanger wire CM7 seismic clip screw attached (optional) x wall molding perimeter hanger wire tee CM7 wall attachment clip Tee Rivet, Tight Wall 3 8" max. 4 8" max. +-0 6 perimeter hanger wire x wall molding pop rivet perimeter hanger wire tee pop rivet CM7 Clip, 5 8" max. 6 8" max. 3 /4" min. +-0 6 perimeter hanger wire CM7 seismic clip x wall molding perimeter hanger wire tee 7 /8" CM7 wall attachment clip 7

Categories D, E, F Standard Seismic pplication Heavy Duty System 2 Molding Systems Summary Suspension System Duty Rating Heavy Wall Molding 2 Seismic Clip None (unless utilized in lieu of stabilizer bars) Two djacent Floating Sides 3/4 gap; no attachment of tee to molding Two djacent Fixed Sides Tight, no gap; pop-rivet attachment of tee to molding Perimeter Hanger Wires Yes Stabilizer Bars Yes Construction Details C Tight Wall 2-gauge hanger wire grid perimeter riveted stabilizer bar C 2 ll main Donn suspension systems DX/DXL, Fineline DXF, Fineline /8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXL, and ZXL include the codecompliant heavy-duty main tees for Seismic Design Categories D, E, and F. For ceiling areas exceeding 2,500 ft. 2 (232 m 2 ), a seismic separation joint may be required. See SC2496 for information on seismic separation joints. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. Convenience holes located in the tee bulb may be used for any and all hanger wires. 8

Pop Rivet, Tight Wall Tee Unattached, C 2" x 2" wall molding hanger wire C 2 2" x 2" wall molding hanger wire pop rivet 2" stabilizer bar tee 2" 3 /4" stabilizer bar tee 2 Seismic Shadow Molding With a 3/4 reveal located by the wall to disguise its width, 2 shadow molding provides an aesthetically pleasing option to traditional 2 seismic molding. Designed for use with 5/6 exposed Donn DX/DXL suspension systems, this seismic shadow molding meets or exceeds all national code requirements and fulfills requirements for Seismic Design Categories D, E, and F. MS274 Profile 9 /32" /4" 3 /4" Preformed corners are available, eliminating the need to miter this molding. Inside Corner Molding Outside Corner Molding For more information about the MS274 2 seismic shadow molding, see Seismic Mold data sheet (C384) or Ceiling Systems catalog (SC2000). 9

Category C lternate Seismic pplication Intermediate Duty DXL-I-C System 7/8 Molding Systems Summary Suspension System Duty Rating Intermediate Wall Molding 7/8 Seismic Clip Floating Sides 3/89 Gap Perimeter Hanger Wires Stabilizer Bars CM7 CM7 seismic clip with fastener attachment to tee through slot (optional), and one fastener through wall molding (optional). None None Construction Details D 2-gauge hanger wire CM7 seismic clip ll main Donn suspension systems DX/DXL, Fineline DXF, Fineline /8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXL, and ZXL include the codecompliant intermediate-duty main tees for Seismic Design Categories, B and C. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. Convenience holes located in the tee bulb may be used for any and all hanger wires. 0

CM 7 Clip, s D CM7 seismic clip screw attached (optional) x wall molding 3 /8" tee

Category C Standard Seismic pplication Intermediate Duty System 7/8 Molding, Stabilizer Bars Systems Summary Suspension System Duty Rating Intermediate Wall Molding 7/8 Seismic Clip None Floating Sides 3/8 gap; no attachment of tee to molding Perimeter Hanger Wires None Stabilizer Bars Yes Construction Details 2-gauge hanger wire stabilizer bar E ll main Donn suspension systems DX/DXL, Fineline DXF, Fineline /8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXL, and ZXL include the codecompliant intermediate-duty main tees for Seismic Design Categories, B and C. The performance of Donn seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended. Convenience holes located in the tee bulb may be used for any and all hanger wires. 2

Tee Unattached, E x wall molding 3 /8" stabilizer bar tee 3

Product Information See usg.com for the most up-to-date product information. ICC Evaluation Service, Inc., Report Compliance Suspension systems manufactured by USG Interiors, Inc., have been reviewed and are approved by listing in ICC-ES Evaluation Report 222. Evaluation Reports are subject to reexamination, revision and possible cancellation. Please refer to usgdesignstudio.com or 800 USG.4YOU for current reports. L.. Research Report Compliance Donn brand suspension systems manufactured by USG Interiors, Inc., have been reviewed and are approved by listing in the following L.. Research Report number: 25764. C56 Disclaimer The current ICC-ES acceptance criterion (C) used for the testing and evaluation of seismic clips is C56, cceptance Criteria for Seismic Qualification by Shake-Table Testing of Nonstructural Components and Systems. C56 was not specifically designed to provide testing guidelines or pass/fail criteria for acoustical suspension systems in a seismic event. However, in the absence of a specific C for this purpose, ICC-ES allowed C56 to act as the basis for all seismic testing and evaluation for the acoustical ceiling suspended ceilings industry. Trademarks The following are trademarks of USG Interiors Inc., or a related company: CE, Centricitee, Donn, Fineline, DX, DXF, DXFF, DXL, DXL, DXLT, DXT, DXW, USG, ZXL. Note The University of Buffalo and the University of California do not endorse specific products. USG assumes no liability for the accuracy of completeness of the drawings for a particular installation or their fitness for a particular purpose. Please consult with a licensed architect or engineer in the particular locale of the installation to assure compliance with all legal requirements. ll products described here may not be available in all geographic markets. Consult your local sales office or representative for information. Notice We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. ny claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read MSDS and literature before specification and installation. Manufactured by USG Interiors, Inc. 550 West dams Street Chicago, IL 6066 C3235/rev. 4-0 200, USG Interiors, Inc. Printed in U.S..