SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series...

Similar documents
T-100-R Installation Guide

Instruction Manual CPPM-4

B/S/H/ Error codes and service programmes PH

REMOTE CONTROL MANUAL

HEAT HEAT COOL HEAT PUMP COOL

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Automatic air conditioning system

Installation Instructions

Portable Air Conditioner

Touch Tone Controller. Model TR16A. Owner s Manual

STERILIZERS, LABORATORY DRYING OVENS

PR 50 Frymaster Universal Holding Cabinet (UHC)

TMS TANK MANAGEMENT SYSTEM

Mode Switch. Fan Switch Menu button Program button

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Failure code manual. content

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Variable Air Volume - VAV

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Aurora UPC ZS Zone Sensors User Guide

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Install Guide 3M-50. Caution. Caution

Niko Home Control. Installation Manual

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Operating instructions IV / 2007

INSTALLER S & OWNER S MANUAL

SWIMMING POOL HEAT PUMP Owners Manual

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

using the Remote Touch unit and push knob to select. STEP 5 Select category and push knob to select. Scroll to specific customization setting.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Owner s Guide. ca6554

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Communicating Wall Control Installation Manual TSTAT0101SC

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

14. Troubleshooting Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Operation Guide 3M-22

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Product and Application Description

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Install Guide CT101. Caution. Caution

3-2. Using the air conditioning system and defogger Automatic air conditioning system

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

evohome Wireless Radiator Zoning Kit Installation & User Guide

touchbga.com TOUCHBGA BGA Rework Station IR-PRO-SC v6 User Manual

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

EBDSPIR-PRM, EBDSPIR-PRM-IP

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

I STAR COMPUTER CO., LTD

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

HERZ-Thermal Actuators

Air Conditioning System

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

USER S MANUAL HSC-24A

MP-4000 Alarm List (Software version or later)

Water-Source Heat Pump

Nexus FS Point of Use Installation Guide

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Product and functional description

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

5W LED Energy Saver PIR Bulkhead

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Incubator with mechanical convection

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

QUICK PROBLEM SOLVING GUIDE

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ELECTRIC CENTRAL HEATING FLOW BOILER

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

EBDSPIR-DD, EBDSPIR-DD-IP

E85 Heating / Air Conditioning System

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

WHITE-RODGERS COMFORT-SET 90 SERIES

Single Day Alarm Clock with. Bluetooth and USB Play-through

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Transcription:

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series... QUICK START USER GUIDE PRODUCT OVERVIEW LED Indicators Refer to Section 2 Low Voltage Outputs (Remote Control) Refer to Section 1B Knob Ranges and Settings Refer to Section 3A Basic 120V Outputs Refer to Section 1A AUX Outputs (sold separately) Refer to Section 1C Lock Settings Refer to Section 3B CO2 Calibration Refer to Section 4 QUICK START USER GUIDE - TABLE OF CONTENT SECTION CONTENT PAGE 1 Output Descriptions 2 1A Basic 120V Outputs 2 1B Low Voltage Outputs (Remote Control) 2 1C AUX 120V Outputs (sold separately) 2 2 LED Indicators 3 2A to Show Ambient Temperature, Humidity and CO2. 3 2B to Show 30-second CO2 Sensor Warm-Up 3 2C to Show Sensor Failures (Temperature, Humidity or CO2) 3 2D to Show Output States 4 3 Knob Settings 4 3A Knob Ranges 4 3B Lock Settings 4 4 CO2 Sensor Calibration 5 5 Temperature Control with Fan (and Optional Heater) 5 6 Temperature and Humidity Control with Fan (and Optional Heater) 5 7 Humidity Control with a Humidifier or Dehumidifier 6 8 CO2 Enrichment with a Burner or a Tank 6 ADVANCED USER GUIDE IS AVALAIBLE ONLINE Detailed information can be obtained on Detailed Information about Temperature and Humidity Control with a Fan Detailed Information about Humidity Control Detailed Information about CO2 Enrichment Detailed Information about Low and High Temperature limits CO2 Sensor Elevation Setting for Precise Reading in Altitude Detailed Information about Priorities and Sensor Failure Actions Detailed Information about the Factory Settings and Alternate Settings How to Change a Factory Setting to an Alternate Setting? and more... 1 of 6

1- OUTPUT DESCRIPTION 1A- BASIC 120V OUTPUTS: MAX. 15A, TOTAL OF THE 3 OUTPUTS FAN HUMIDITY EQUIPMENT For Day / Night COOLING ONLY or COOLING AND DEHUMIDIFYING as set by the Slide Switch. 15A MAX. if used alone. For Day / Night HUMIDIFYING or DEHUMIDIFYING as set by the Slide Switch (and type of equipment used). 15A MAX. if used alone. CO2 GENERATOR For Day only CO2 ENRICHMENT, using either a tank or a burner. 5A MAX. for inductive load, if used alone. 1B- LOW VOLTAGE OUTPUTS (REMOTE CONTROL 24V) (These screw terminal interface plays the same role as Grozone LVC1 interface, visit for more details on LVC1) AIR CONDITIONING (A/C) HUMIDITY EQUIPMENT For Day / Night COOLING ONLY or COOLING AND DEHUMIDIFYING as set by Slide Switch. SCC1 DOES NOT SUPPLY POWER TO REMOTE A/C. SCC1 screw terminals are hooked-up to A/C screw terminal using any type of wire. Refer to A/C User Guide for proper connection. For Day / Night HUMIDIFYING or DEHUMIDIFYING as set by Slide Switch and type of equipment used. SCC1 DOES NOT SUPPLYPOWER TO REMOTE HUMIDITY EQUIPMENT (HE). SCC1 screw terminals are hooked-up to HE screw terminal. Refer to HE User Guide for proper connection. 1C- AUX 120V OUTPUTS (SOLD SEPARATELY) (optional Output using remote Output Boxes See Advanced User Guide for more details) AUX HEATER For Day / Night HEATING. User needs to connect an optional Remote Output Box (OB2) with 25-ft telephone cable. 15A MAX for this output only, because it is connected to a different 120V outlet.. AUX FAN For Day / Night COOLING. User needs to connect an optional Remote Output Box (OB2V) with 25-ft telephone cable. OB2V works as a Remote TV1 or TV2 Grozone Variable Speed Fan Controllers. Fan speed will vary according to the amount of heat to exhaust. Limited to 6A or 750W. 2 of 6

2- LED INDICATORS 2A- TO SHOW AMBIENT TEMPERATURE, HUMIDITY AND CO2 Example of LEDs indicating a temperature of 81 to 85 F, a humidity level of 35% to 49% and a CO2 level of 1700 to 2000 ppm. All the LED indicator possibilities are: TEMPERATURE 96 F AND MORE 91 F TO 95 F 86 F TO 90 F 81 F TO 85 F 76 F TO 80 F 71 F TO 75 F 70 F AND LESS HUMIDITY 96% AND MORE 80% TO 95% 65% TO 79% 50% TO 64% 35% TO 49% 20% TO 34% 19% AND LESS CO2 2001 AND MORE 1700 TO 2000 1400 TO 1700 1100 TO 1400 800 TO 1100 500 TO 800 499 AND LESS 2B- TO SHOW SENSOR WARM-UP PERIOD TEMPERATURE HUMIDITY CO2 Not applicable Values are valid from Power ON. Not applicable Values are valid from Power ON. 30-Sec Warm-Up Time at Power Up: CO2 Sensor needs 30-sec warm up before reading valid values. 2C- TO SHOW SENSOR FAILURES (TEMPERATURE, HUMIDITY OR CO2) TEMPERATURE HUMIDITY CO2 Temperature Sensor Fail Humidity Sensor Fail CO2 Sensor Fail Refer to Advanced User Guide for detailed information about the top priority automatic actions undertaken in case of sensor failure. 3 of 6

2D- TO SHOW OUTPUT STATES OUTPUTS Output Indicator OFF Output Indicator ON Output Indicator FLASHING Output relay IS NOT activated, Output relay IS activated, receptacle DOES supply 120V Output relay activation is pending, because at least one of these conditions is met: 1. high priority CO2 Output is ON (factory setting) 2. 10-min. ON-DELAY is counting down after CO2 output has turned OFF.; 3. Low Temp Limit has been reached only if Cool&Dehum is set Output relay IS NOT activated, Output relay IS activated, receptacle DOES supply 120V Will never flash, not implemented Output relay IS NOT activated, Output Box OB2 is NOT connected OR Output Box OB2 IS NOT activated, Output Box OB2V is NOT connected OR OB2V is forced to OFF during a Temperature Sensor Failure. Output relay IS activated, receptacle DOES supply 120V OB2 relay IS activated, Output Box receptacle DOES supply 120V Note: Indicator will remain ON if OB2 is disconnected while activated.indicator will not turn ON anymore once it turns OFF. Normal Operation OB2V is DIMMING Fan Speed (can be fully OFF, fully ON or DIMMED as per settings) Output relay activation is pending, because at least one of these conditions is met: 1. High Temp Limit has been reached; 2. Empty Tank: High Temp Limit reached twice in a row OR 30-minute timeout elapsed WHILE CO2 level is still low. 3. High priority FAN Output is ON (alternate setting). Will never flash, not implemented Will never flash, not implemented 3- KNOB SETTINGS 3A- KNOB RANGES DAY AND NIGHT TEMPERATURE SETTINGS: 55 F to 95 F / 13 C to 35 C DAY AND NIGHT HUMIDITY SETTINGS: 10% to 90 F DAY CO2 SETTING: OFF, 400 TO 2000 (Note: all value below 400 ppm will be set to 400 ppm) For CALIBRATION, refer to Section 4. 3B- LOCK SETTINGS PLACE SLIDE SWITCH TO UNLOCK (TOP POSITION) TO SET YOUR KNOB VALUES PLACE SLIDE SWITCH TO LOCK (BOTTOM POSITION) TO SAVE YOUR KNOB VALUES. IMPORTANT NOTICE: ONCE LOCKED, VALUES WILL BE PRESERVED EVEN THOUGH KNOBS ARE ROTATED INADVERTENTLY. IMPORTANT NOTICE: DO NOT FORGET TO UNLOCK BEFORE CHANGING YOUR SETPOINTS. 4 of 6

4- CO2 SENSOR CALIBRATION CO2 Sensor Calibration is performed in 4 easy steps. 1- Place the LOCK/UNLOCK Slide Switch to the UNLOCK Position (Top position). 2- Set the CO2 Day Setpoint to the CAL position (fully counter clockwise). 3- In order to get a VALID CALIBRATION, the unit must be placed temporarily outdoors or in fresh air, where natural CO2 level is close to 400 ppm. 4- Push and hold button for 10 seconds: the 3 CO2 Ambient LED Indicators will blink every second 10 times, then the Indicators will remain LIT until you let the pushbutton go. If the CALIBRATION is good, the indicators will blink 4 times If the CALIBRATION is bad, the indicators will blink only once. The unit returns to Normal Operation. 5- TEMPERATURE CONTROL WITH FAN (and Optional Heater) To use this mode, you connect your cooling Fan into the FAN 120V Output, set the Slide Switch to Cooling position. 6- TEMPERATURE AND HUMIDITY CONTROL WITH FAN (and Optional Heater) To use this mode, you connect your cooling Fan into the FAN 120V Output, set the Slide Switch to Cooling & Dehumidifying position. 5 of 6

7- HUMIDITY CONTROL WITH A HUMIDIFIER OR DEHUMIDIFIER To use this mode, you connect your Humidity Equipment (Humidifier or Dehumidifier) into the HUMIDITY 120V Output, set the Slide Switch to either Humidifying or Dehumidifying according to your equipment type. HUMIDIFYING - SLIDE SWITCH TO TOP POSITION DEHUMIDIFYING - SLIDE SWITCH TO BOTTOM POSITION 8- CO2 ENRICHMENT WITH A BURNER OR A TANK To use this mode, you connect your CO2 Generator into the CO2 120V Output. CO2 Enrichment will work during the DAY ONLY. 6 of 6