EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Similar documents
Safety instructions VEGADIS DIS81.CEIA/V****

Explosion proof enclosures

SEISMIC VELOCITY TRANSDUCER T1-40

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Instructions for Safe Use

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive slot sensor

Technical Data. Dimensions

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

2.12. page Products for Explosion hazardous Environment

Flow switches Series AD/VH

Terminal Box. Specifications TNCN

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Hazardous location. Definitions

Technical data sheet TDS0070

FGM 160 ATEX EC type examination certificate

David O Brien, CMP Products (David.OBrien@cmp-products.com)

INTERNATIONAL STANDARD

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

CONSULTING Training Courses

2CMC300001D0003 November Enclosed switches ATEX

Floodlight Range Installation Guide

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Wolflite Safety Handlamp H-251E

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Operataing Manual. Single stage radial Fan. Model MKV/TKV

Instruction Manual Differential Pressure Transmitter

3DLevelScanner II TECHNICAL DATA SHEET

Original instructions Tina 3A/Aps Adaptor unit

Micro Motion 3098 Gas Specific Gravity Meter

Tina 2A/B Adaptor unit

Technical Data Sheet. 3DLevelScanner

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Explosion-Proof Electric Unit Heaters

Variable speed drives for synchronous and asynchronous motors

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Operating Instructions

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Operating Instructions

Installation & User Instructions

PREPIPED LIQUID FUEL MANIFOLDS PLPM

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Product Brochure. Certified Mining Motors

Terminal Boxes Series 8146

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

CLASSIFICATION SERIES: Mine Safety Inspector MAJOR AGENCIES: Natural Resources

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Installation Instructions It is recommended to check the following points when receiving this product:

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Threaded Resistance Thermometers Model TR10-D, Miniature Design

1805 Series Relief Valves

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

SHOT BLAST CABINET MODEL NO: CSB20B

Electrical Classification

FUNCTIONAL SAFETY CERTIFICATE

Series 510 Submersible Level Transmitters

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

G670 Intermittent Pilot Ignition Controls

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved


Connection Cable for LED Driver Board

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

4 Posiflow Proportional Solenoid Valves

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Equipment vs. Component

Ambient Temperature Sensor TEMPSENSOR-AMBIENT

=============================== WARNING

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Single- and Two- Stage Regulators

Single sub-base valve

4/2-Way Pneumatic Solenoid Valve

Operating Instructions

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Transcription:

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ13.1295X Manufacturer: Product: Model Specification: Anti-explosion Mark: Topworx Inc. (Address: 3300 Fern Valley Road, Louisville, Kentucky 40213, USA) Valve position switch DXP, DXS series Please refer to the attachment of the Explosion Protection Certificate of Conformity for details Product standard / Drawing No. S-AV1-0003 Rev.15 After examining the drawings and technical documents as well as sample testing, it has been confirmed that the abovementioned products are in compliance with GB 3836.1-2010, GB 3836.2-2010 and GB 12476.1-2000 standards and this certificate is hereby issued. This certificate is valid from September 30, 2013 to September 29, 2018 Remarks: 1. Please refer to the attachment of this certificate for safety precautions. 2. Please refer to the attachment of this certificate for specific model specifications. 3. This certificate is applicable to products with same model number manufactured by Emerson Machinery Equipment (Shenzhen) Co., Ltd. (Address: Bao Heng Technology Industry Park, North Hong Lang 2nd Road, District 68, Bao an District, Shenzhen) and Emerson Process Management Magyarorszag Kft. (Address: H-8001 Szekesfehervar Berenyi U 72-100, Hungary) 4. [Amendment I]: additional manufacturing site, issued on July 9, 2014. Director [Signature - illegible] Date of Issue September 30, 2013 [Seal ] This certificate is valid only for products matching the approved documentation and sample. 103 Cao Bao Road http://www.nepsi.org.cn Tel: +86 21 64368180 Shanghai 200233, China Email: info@nepsi.org.cn Fax: +86 21 64844580 Edition 05

This is to certify that the product Switchboxes manufactured by Topworx Inc. which model is EXPLOSION PROTECTION C E RTIFI C AT E OF CO N FO RMITY Cert No. GYJ13.1295X (Address: 3300 Fern Valley Road, Louisville, Kentucky 40213, USA) DXP and DXS series Ex marking See attachment to this certification product standard / drawing number S-AV1-0003 Rev.15 has been inspected and certified by NEPSI, and that it conforms to GB 3836.1-2010, GB 3836.2-2010, GB 124761.1-2000. This approval shall remain in force until September 29, 2018 Remarks 1. Conditions for safe use are specified in the attachment to this certificate. 2. Safe parameters specified in the attachment to this certificate. 3. This certificate is also applicable for the product with the same type manufactured by Emerson Machinery Equipment (Shenzhen) Co., Ltd. (Address: Bao Heng Technology Industry Park, North Hong Lang 2nd Road, District 68, Bao an District, Shenzhen, P.R. China) and Emerson Process Management Magyarorszag Kft. (Address: H-8001 Szekesfehervar Berenyi U 72-100, Hungary) 4. [variation I]: Add manufacturing site, issued on July 9, 2014. Director [Signature - illegible] Issued Date September 30, 2013 [Seal ] This certificate is valid only for products compatible with the documents and samples approved by NEPSI. 103 Cao Bao Road http://www.nepsi.org.cn Tel: +86 21 64368180 Shanghai 200233, China Email: info@nepsi.org.cn Fax: +86 21 64844580 Edition 05

(GYJ13.1295X) (Attachment I) GYJ13.1295X Explosion Protection Certificate of Conformity Attachment I After inspection by the Explosion Protection and Safety Instrumentation (NEPSI), the DXP, DXS series of valve position switches produced by Topworx Inc., Emerson Process Management Magyarorszag Kft., and Emerson Machinery Equipment (Shenzhen) Co., Ltd. have been found to be in compliance with the following standards: GB3836.1-2010 Explosive Atmosphere Part 1: Equipment - General Requirements GB3836.2-2010 Explosive Atmosphere Part 2: Equipment Protected by Explosion Protection Type d GB12476.1-2000 Electrical Equipment Used in Combustible Dust Atmosphere Part 1: Electrical Equipment Protected by Enclosure and Surface Limitation - Section 1: Technical Requirements on Electrical Equipment The DXS series and DXP series valve position switches use flat connection surface that have explosion protection label Ex d II B+H 2 T3~T6 Gb, DIP A21 T A, T3~T6 Db. The DXP series valve position switches use spiral connection surface that have explosion protection label Ex d II C T3~T6 Gb, DIP A21 T A, T3~T6 Db. The enclosure protection level satisfies the IP66 and IP67 requirements. The Explosion Protection Certificate of Conformity s certificate number is GYJ13.1295X. This certificate recognizes products with the specific model number: DXa-b c d e f g h Where: a indicates enclosure material; can be P or S; b indicates main line and sensor; can be L, M, K, T or O; c indicates equipped with HART protocol or not; can be H, X or 1~6 d indicate the type of explosion protection; can be 1 which represents II B+H 2 or C which represents II C; e f g h are parameters not related to explosion protection. I. Specific Conditions for Safety Precaution If the certificate number ends with a X, it indicates that the product has special conditions for safety precaution: 1. This product is not suitable for use in the presence of carbon disulfide explosive gas atmosphere; 2. After this product has been correctly installed, the manifold pressure should not exceed 1MPa; 3. Enclosure protection level should be IP66 or IP67, it may only be used in ambient temperature under 110 C; 4. The fastener performance level should meet A2-70, the thread precision should be M8X1.25-6H; 5. Maintenance of the connection surfaces of product explosion protection should be done by the manufacturer. II. Safety Precaution 1. The rated input voltage for this product is 240V, the rated input current is 15A, and switches, onsite bus modules, guide post and terminal post array with power dissipation of less than 10W may be installed inside; Page 1 of 3

(GYJ13.1295X) (Attachment I) 2. Relationship between product s temperature groups and the ambient temperature: Gas Group Ambient Range Ambient Range Dust Group T3-60ºC ~ +175ºC / / T4-60ºC ~ +110ºC T4-50ºC ~ +110ºC T5-60ºC ~ +75ºC T5-50ºC ~ +75ºC T6-60ºC ~ +60ºC T6-50ºC ~ +60ºC 3. When the ambient temperature is -60ºC, the manufacturer should conduct routine static pressure test before the product leaves the factory, the static pressure for the II C group is 2.8MPa, and 1.91MPa for II B group, and the product s outer enclosure should not have permanent damage or deformation. 4. The product s outer enclosure is equipped with grounding terminal. When it is used by the user after installation, it can be grounded. 5. The installation site must comply with the principle of open the cap after power is turned off. 6. Harmful gases with corrosive effect on aluminum alloy should not be present at the installation site. 7. When installing product onsite, cables that have passed the inspection of State designated testing laboratories with explosion protection grade of Exd II C, thread specification of 1/2NPT, 3/4NPT, M16x1.5 or M20x1.5 must be used for the cable entry point that leads into the device or blanking element, and redundant cable inlets must be effectively sealed by blanking elements. 8. The user should not replace the parts by themselves, and should work with the product manufacturer to jointly resolve malfunctions that occurred during operations to prevent damage. 9. Maintenance may proceed only when the installation site has been confirmed not to have any harmful gases. 10. When this product is used onsite, its surface should be cleaned regularly and the thickness of dust accumulation should not exceed 5mm. 11. The installation, use and maintenance of this product shall comply with the relevant provisions in the product manuals, GB3836.13-1997 Electrical Equipment Used in Explosive Gas Atmosphere Part 13: Inspection and Maintenance of Electrical Equipment Used in Explosive Gas Atmosphere, GB3836.15-2000 Electrical Equipment Used in Explosive Gas Atmosphere Part 15: Electrical Installation in Dangerous Places (Except Coal Mines), GB3836.16-2006 Electrical Equipment Used in Explosive Gas Atmosphere Part 16: Inspection and Maintenance of Electrical Equipment (Except Coal Mines), GB50257-1996 Electrical Equipment Installation and Acceptance Standards for Electrical Equipment Installation in Dangerous Explosive and Fire Hazard Atmosphere, GB15577-2007 Safety Regulation on Dust Explosion Protection, and GB12476.2-2006 Electrical Equipment Used in Combustible Dust Atmosphere Part 1: Electrical Equipment Protected by Enclosures and Surface Limitation Section 2: The Selection, Installation and Maintenance of Electrical Equipment. III. Responsibilities of the Manufacturer: 1. The manufacturer must incorporate the special requirements and safety precautions mentioned above into the product manual; 2. The manufacturer must produce the product strictly in compliance with the documentation approved by NEPSI; Page 2 of 3

(GYJ13.1295X) (Attachment I) 3. The product nameplate must at least include the following: a) NEPSI Approval Label (please refer to the Explosion Protection Certificate of Conformity) b) Product s Explosion Protection Label c) Explosion Protection Certificate of Conformity s Certificate Number d) Ambient September 30, 2013 [Seal ] Page 3 of 3