5.3.2 The container marking shall contain the following information:

Similar documents
OSHA Tank Venting DEFINITIONS

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

THE PROPANE TECHNICAL POCKET GUIDE

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

This will also provide you with the knowledge to insure long life for your Investment

Technical Information

Pump Formulas Imperial and SI Units

A practical guide to restrictive flow orifices

Jump Start: Storage Tank Protection in Aspen HYSYS and Aspen Plus

SIZING AND CAPACITIES OF GAS PIPING

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

LIQUEFIED PETROLEUM GASES

SIZING AND CAPACITIES OF GAS PIPING

UNDERSTANDING REFRIGERANT TABLES

Installation of Underground LP-Gas Systems

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

Heating Water by Direct Steam Injection

STEPS TO COMPRESSOR SELECTION & SIZING

LP-Gas Serviceman s Manual

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS. Thermodynamic Properties

Air Eliminators and Combination Air Eliminators Strainers

G234X-55 Conventional Gas Boiler

CLEANING, INSPECTION, AND TESTING OF SEWERS

Open Cycle Refrigeration System

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Pentair Pressure Relief Valve Engineering Handbook

HOW TO SIZE A PRESSURE REGULATOR

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

C. starting positive displacement pumps with the discharge valve closed.

PRESSURE EQUIPMENT SAFETY REGULATION

CO MPa (abs) 20 C

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Portable Pipelines for First Responders

NFPA31FuelOilPiping 1 Revised

THE PSYCHROMETRIC CHART AND ITS USE

1. Define the System SDV BDV SDV SDV SDV BDV SDV SDV SDV SDV SDV SDV. Process System TO FLARE TO FLARE BDV TO FLARE

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Standard Pneumatic Test Procedure Requirements for Piping Systems

NFPA : Basic Requirements for Storage Tanks

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Theory, Application, and Sizing of Air Valves

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

Water hammering in fire fighting installation

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

BODY OF KNOWLEDGE API-510 PRESSURE VESSEL INSPECTOR CERTIFICATION EXAMINATION

How To Understand Fluid Mechanics

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition

Design of a Fuel Oil Storage Facility

1805 Series Relief Valves

Calculating Heat Loss by Mark Crombie, Chromalox

NATIONAL RESEARCH COUNCIL CANADA. DIVISION OF BUILn ING RESEARCH DESIGN OF EXPOSED SEWER PIPES FOR INTERMITTENT USE UNDER FREEZING CONDITIONS

University of Tennessee Safety Guidelines

INTERIM UNITS OF MEASURE As suggested by Federal Standard 376B January 27, hectare (ha) Hundred for traffic buttons.

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

In-Line Air Separators

Piping Hydraulic Line Design and Sizing Software KLM Technology Group

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

Rusty Walker, Corporate Trainer Hill PHOENIX

Some Criteria for Choosing a Steam Boiler for a Microbrewery

The following definitions apply with regard to requirements specified in this document:

Liquid level measurement using hydrostatic pressure and buoyancy

Select the Right Relief Valve - Part 1 Saeid Rahimi

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

11.6 Formulas to be used when changing atmosphere in an tank

Installation Guidance: CNG Refueling Stations

Preferred SI (Metric) Units

REGULATING VALVE APPLICATIONS

LPG Vessels Custom Quality in Every Detail

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Pressure Vessels (Air Compressors) and LPG Tanks

PREPIPED LIQUID FUEL MANIFOLDS PLPM

CONTROL VALVE PRESSURE DROP AND SIZING

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Commercial & Industrial Propane Regulators and Meters

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Sizing Pressure Regulators & Control Valves

Contents and Nomenclature

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Requirements for Hydrogen Storage and Use

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Chapter. Flares and Stacks. Flares (FLR) Stacks (STK) G2 ICARUS Corporation, 1998.

1301 Series High-Pressure Regulators

Characteristics of Evaporators

Fluid & Gas Properties

Transcription:

1 of 5 2/4/2013 3:19 PM Committee Input No. 57-NFPA 59-2012 [ Section No. 5.3.2 ] 5.3.2 The container marking shall contain the following information: (1) Name and address of the container supplier or the trade name of the container (2) Water capacity of the container in pounds or U.S. gallons (3) Design pressure in pounds per square inch (psi) (4) The wording This container shall not contain a product having a vapor pressure in excess of psi at 100 F (see Table 5.2.1 ) (5) Outside surface area in square feet (6) Wetted surface area in square feet, based upon a filling density of 80% by volume (7) Year of manufacture (8) Shell thickness and head thickness (9) * OL (overall length), OD (outside diameter), HD (head design) (10) Manufacturer's serial number (11) ASME Boiler and Pressure Vessel Code symbol (12) Minimum design metal temperature F at MAWP psi (13) Type of Construction "W" (14) Degree of radiography "RT- " Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Submittal Date: Thu Oct 04 16:23:23 EDT 2012 Committee Statement and Meeting Notes Committee Statement: Response Message: The proposed changes support the revised method for relief device sizing proposed in Committee Input No 58 and 59 (10.2.3 and Annex D). CI-57-NFPA 59-2012

2 of 5 2/4/2013 3:19 PM Committee Input No. 58-NFPA 59-2012 [ Sections 10.2.3, 10.2.4, 10.2.5, 10.2.6 ] Sections 10.2.3, 10.2.4, 10.2.5, 10.2.6 10.2.3 The minimum rate of discharge of pressure relief valves installed in ASME containers shall be in accordance with Table 10.2.3 or shall be calculated using the following formula: 10.2. Q = 34,500 A 0.82 where: F Q = flow rate (SCFM air heat input resulting in vaporization of contents (Btu/hr ) A = total outside wetted surface area of container (ft 2 ) [ 58: 5.7.2.6] Table 10.2.3 Pressure Relief Valve Flow Capacity as a Function of Container Surface Area Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM)?20 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 190 3960 800 12,8 SI units, 1 SCFM = 0. 0283 m 3 /min. Note: Flow rate in SCFM air. [ 58: Table 5.7. 2. 6] 4 Relief valves for aboveground ASME containers shall relieve at not less than the flow rate specified in 10.2.3 before the pressure exceeds 120 percent of the minimum permitted start-to-leak pressure setting of the device, excluding the 10 percent tolerance in Table 10.2.2.1. [ 58: 5.7.2.7] Determination of the required flow rate shall be based on the latent heat of vaporization of the contents at P, the specific volume at saturation of the content's vapor at P, and the sonic max max velocity of the contents at P max. See Annex D for calculation procedure and determination of equivalent relieving capacity in SCFM of air. 10.2.5 If there is liquid product is placed exceeding 10% by volume in containers while they are not buried, the pressure relief valve sizing shall be that of aboveground containers. 10.2.6 30 The flow capacity of pressure relief valves installed on underground or mounded containers shall be a minimum of

10 percent of the flow specified in Table 10.2.3. [ 58: 5.7.2.8] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Submittal Date: Thu Oct 04 16:38:36 EDT 2012 Committee Statement and Meeting Notes Committee The 1953 edition of the National Fire Protection Association s (NFPA) pamphlet NFPA 58 (which was Statement: then titled Storage and Handling Liquefied Petroleum Gases 1953 ) adopted an air equivalent value for tank relief valve sizing of: CFM air=53.632a^0.82 When, A equals the total surface area of the tank in square feet. That formula was based, in part, upon the report of John H. Fetterly dated November 27, 1928. Prior to that time; NFPA 58, beginning in the 1932 edition, based relief valve size upon the Diameter (D) times the length (U) of the vessel. The 1953 calculation, which is still in effect in the most recent editions of both NFPA 58 Liquefied Petroleum Gas Code, 2011 and NFPA 59 Utility LP-Gas Plant Code, 2012 is based upon a total heat input Q: Q=34,500A^0.82 Btu/hr. The heat flux value of 34,500 Btu/ft2 hr. is also adopted in several NFPA codes and standards with some modification for larger vessels. The calculations that led to the adoption of "CFM air=53.632a^0.82 in the 1953 edition were apparently based is upon a single value for the latent heat of vaporization (?h) regardless of either pressure or composition (i.e., butane or propane) and may have miscalculated the variation in sonic velocity of both air and the propane or butane. It is also possible that reliable thermodynamic property data was unavailable at that time. It should also be noted that the propane or butane vented by a relief valve is a saturated vapor while the air used for testing can be considered to be a perfect gas, which may have not been considered in those calculations. This proposal up-dates the original calculations for relief valve capacity by incorporating the specific physical properties of both propane and butane and by basing the calculations upon the sonic velocity of both the protected medium and air. In addition, this proposal would revise the rate of heat input from total surface area to the more realistic wetted surface area. This would make NFPA 59 consistent with NFPA 30 (see 22.7.3.3 ). The revision of 10.2.5 provides a reasonable and safe alternative to the complete evacuation of buried or mounded tanks when it becomes necessary to expose the tank for inspection or repair. In addition, this proposal would reduce the required relieving capacity of mounded tanks to a more realistic value of 10% of that required for aboveground tanks, because they are not subject to fire exposure, and therefore do not need relief valves to relieve overpressure due to fire exposure. The proposed changes incorporated within this proposal will not affect any existing ASME containers but it will, in some cases, result in a reduced relief valve size for some large and higher pressure containers, while making the sizing procedures technically correct. Other minor changes have been proposed to either clarify the meaning or to match the wording in NFPA 58. Response CI-58-NFPA 59-2012 Message: 3 of 5 2/4/2013 3:19 PM

4 of 5 2/4/2013 3:19 PM Committee Input No. 59-NFPA 59-2012 [ Chapter D ] Annex D Relief Device Sizing This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. D.1 Nonrefrigerated Containers. Table D.1 should be used to size pressure relief valves. Surface area equals the total outside surface area of the container in square feet. Where the surface area is not stamped on the nameplate or where the marking is not legible, the area can be calculated by using one of the following formulas: (1) Cylindrical container with hemispherical heads: Area = Overall length outside diameter 3.1416 (2) Cylindrical container with other than hemispherical heads: Area = (Overall length + 0.3 outside diameter) outside diameter 3.1416 (3) Spherical container: Area = Outside diameter squared 3.1416 Flow rate of air (ft 3 /min) = required flow capacity in cubic feet per minute of air at standard conditions, 60 F (15.6 C), and atmospheric pressure [14.7 psia (101 kpa)]. The rate of discharge can be interpolated for intermediate values of surface area. For containers with a total outside surface area that is greater than 2000 ft 2 (186 m 2 ), the required flow rate can be calculated using the following formula: where A = total outside surface area of the container (ft 2 ) (0.4719 L/s) Table D.1 Minimum Required Rate of Discharge in Cubic Feet per Minute of Air at 120 Percent of the Maximum Permitted Start-to-Discharge Pressure for Safety Relief Devices to Be Used on Nonrefrigerated Containers Other than Those Constructed in Accordance with U.S. Department of Transportation Specifications Surface Area (ft 2 ) Flow Rate (ft 3 /min air) Surface Area (ft 2 ) Flow Rate (ft 3 /min air) Surface Area (ft 2 ) Flow Rate (ft 3 /min air) 20 or less 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 Note: ft 2 = 0.09 m 2 ; ft 3 /min = 0.4719 L/s. Supplemental Information File Name Description AnnexD_Revised.docx Revised Annex D Submitter Information Verification

Annex D Relief Device Sizing This annex is not a part of the requirements of this NFPAdocument but is included for informational purposes only. D.1 Spring-Loaded Pressure Relief Valves for ASME Containers. The requirement for the sizing of relief valves on ASME tanks used for the storage of liquefied gases is that the valve be adequate to prevent the pressure rising above (P max ) which is 120% of the Maximum Allowable Working Pressure (MAWP). Relief valves are tested with air at P max and 60 F rather than with the medium that they are designed for. Relief valves shall be marked with their rated air capacity. It then becomes necessary to determine the equivalent sizing for the particular tank and its exposure.. The inlet versus outlet pressure of a relief valve in LP-Gas service far exceeds the 2:1 critical pressure ratio. Therefore the flow through the valve will be limited to sonic velocity. The sonic velocity of a perfect gas (such as air) is: Where: g = the acceleration due to gravity = 32.2 ft/sec 2 k = the ratio of specific heats = c p /c v R = the universal gas constant = 1545 ft-lb/ R lb-mole T = absolute temperature, R M = molecular weight of gas The Molecular weight of air is 28.9586 and the ratio of specific heats is 1.4. Therefore the sonic velocity (V air) for air at 60 F (520 R) is 1,118.33 ft/sec The p-v-t relationship for a perfect gas is: Where: p = absolute pressure, lb/ft 2 (psf) v = specific volume, ft 3 /lb In the case of a non-perfect gas, such as a saturated vapor, substitute using the value for specific volume (v) for the saturated vapor at P max from the published physical properties (equation of state) of the fluid when calculating sonic velocity, resulting in The weight or mass flow (W) of vapor generated that requires venting by the relief valve is or The volumetric flow (φ gas), at flowing pressure and temperature is

ft 3 /sec. where; (v) equals the specific volume of the gas at flowing pressure and temperature. The effective orifice (α) necessary to accommodate the volumetric flow (φ) is: ft 2 The volumetric flow of air (φ air ) through that same effective orifice will be: ft 3 / sec The mass flow ( of air will be: lb/sec When v air is the specific volume of air at Pmax and at 60 F. The test value will be: where: vstd is the specific volume of a standard cubic foot (scf) of air at 14.696 psia and at 60 F which is 13.11ft 3 /lb. The following calculations are based upon: Air Molecular weight = 28.9586 k = 1.4 Propane Molecular weight = 44.026 k = 1.13 n-butane Molecular weight = 58.122 k = 1.09 Combining, yields: PROPANE MAWP P max T R v v Δh V g v air CFM air A o.82

100 135 534.6 0.8054 145.51 755.1 1.4275 43.29 150 195 561.8 0.5454 133.16 746.8 0.9883 46.78 200 255 583.1 0.4082 121.76 738.8 0.7557 50.62 250 315 601.1 0.3188 110.48 725.6 0.6118 54.80 312 389 620.5 0.242 95.69 702.6 0.4954 61.25 nbutane MAWP P max T R v v Δh V g v air CFM air A o.82 100 135 628.6 0.6976 127.23 689.9 1.4275 46.93 150 195 659.8 0.4732 115.25 682.9 0.9883 51.29 200 255 684.9 0.3455 103.74 667.3 0.7557 55.68 250 315 705.7 0.267 92.06 652 0.6118 61.29 312 389 727.4 0.2 76.55 627.1 0.4954 70.90

5 of 5 2/4/2013 3:19 PM Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Submittal Date: Thu Oct 04 16:51:27 EDT 2012 Committee Statement and Meeting Notes Committee The 1953 edition of the National Fire Protection Association s (NFPA) pamphlet NFPA 58 (which was Statement: then titled Storage and Handling Liquefied Petroleum Gases 1953 ) adopted an air equivalent value for tank relief valve sizing of: CFM air=53.632a^0.82 When, A equals the total surface area of the tank in square feet. That formula was based, in part, upon the report of John H. Fetterly dated November 27, 1928. The 1953 calculation, which is still in effect in the most recent editions of both NFPA 58 Liquefied Petroleum Gas Code, 2011 and NFPA 59 Utility LP-Gas Plant Code, 2012 is based upon a total heat input Q: Q=34,500A^0.82 Btu/hr. The heat flux value of 34,500 Btu/ft2 hr. is also adopted in several NFPA codes and standards with some modification for larger vessels. The calculations that led to the adoption of "CFM air=53.632a^0.82 in the 1953 edition were apparently based is upon a single value for the latent heat of vaporization (?h) regardless of either pressure or composition (i.e., butane or propane) and may have miscalculated the variation in sonic velocity of both air and the propane or butane. It is also possible that reliable thermodynamic property data was unavailable at that time. It should also be noted that the propane or butane vented by a relief valve is a saturated vapor while the air used for testing can be considered to be a perfect gas, which may have not been considered in those calculations. This proposal up-dates the original calculations for relief valve capacity by incorporating the specific physical properties of both propane and butane and by basing the calculations upon the sonic velocity of both the protected medium and air. In addition, this proposal would revise the rate of heat input from total surface area to the more realistic wetted surface area. This would make NFPA 59 consistent with NFPA 30 (see 22.7.3.3 ). Response CI-59-NFPA 59-2012 Message: Committee Notes: Date Submitted By Oct 4, Denise Beach See attachment AnnexD_Revised for replacement text. 2012