Solar Inverters HIVERTER - NP201i Series

Similar documents
Hitachi DATA Center UPS

ABB central inverters PVS to 1000 kw

At a Glance. Constructed Over 3.0 million sq. ft. in Retail, Entertainment, Commercial, Parking & Residential Assets. Planned (next 3 years)

Re-defining the utility-scale inverter

BSES Rajdhani Power Limited Delhi CAT 1 0. BSES Yamuna Power Limited Delhi CAT 1 0. Bharat Sanchar Nigam Limited Ahmedabad CAT 1 0

Green Energy Solutions

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Government of India Ministry of New and Renewable Energy MNRE

A. 5MWp SPV Plant at Khimsar, Rajasthan. B. 5MWp SPV Plant Installed Technologies. D. 5MWp SPV Plant Challenges. E. 5MWp SPV Plant - Performance

ELECTRIC FORKLIFT TRUCK

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

STATUS REPORT MUNICIPAL SOLID WASTE MANAGEMENT

PCS100 ESS. 2UCD190000E002 Rev C. Grid Connect Interface for Energy Storage Systems 100kVA to 10MVA Technical Catalogue

Phase Modular Finally the benefits of Modular ups are for all

INVERTER SYSTEM PRODUCT BROCHURE

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

PRODUCTS AND SERVICES

SolarMax P series The power package for residential solar plants

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

4.0 UPS dedicated to ICT for unmatched energy savings

FAQ on ECS - Credit Clearing

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

BB800 Off-Grid Solar System

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

User s Manual Before using the inverter, you need to read and save the safety instructions.

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

JoSAA 2016 : Course wise vacancy status after round 2 seat acceptance

Liebert NXC from 10 to 200 kva

Telecom Regulatory Authority of India. Engagement of Consultant for conducting a market survey of consumers of Cable and Television services

Galaxy VM. Three-phase power protection. schneider-electric.com

NC-12 Modbus Application

Solutions for Photovoltaic Systems. Large buildings and power plants

vacon 8000 solar inverter a driving force in solar energy

Frequency Converter Fv

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

ESTIMATES OF MORTALITY INDICATORS

Web Edition: PROVISIONAL POPULATION TOTALS. Chapter 5. Census of India 2001 Series 1, India, Paper 1 of Chapter 5

MAJORSINE Power Inverter

Permissible ambient temperature Operation Storage, transport

TIG INVERTER INSTRUCTION MANUAL

Satcon Solstice 100 kw System Solution

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

WVC300 Micro-inverter solar grid system (Power line communications)

NOTICE. Government of India, (Department of Animal Husbandry, Dairying and Fisheries), Ministry of Agriculture Krishi Bhawan, New Delhi

Power Electronics Testings

Trip circuit supervision relay. Type RXTCS

MOST IMPORTANT TERMS AND CONDITIONS

Fronius IG Plus. The next generation grid-connected PV inverter

Establishment of Multi-Disciplinary Research Units (MRUs) in Government Medical colleges /Research Institutions

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Number 1 in efficiency

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

ABB PSPS Erich Steinmann; Generator control-2013

How To Make A Fronius Cl Power Inverter

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

EssPro Energy Storage Grid Substation The power to control energy

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

BASE YEAR UPDATION OF CONSUMER PRICE INDEX NUMBERS FOR INDUSTRIAL WORKERS (CPI-IW)OF SERIES 2001=100 TO 2015=100

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Women s Energy Justice Network: CDM Financing and Microlending for Appropriate Technology REEEP Output # N3123

SVKM s Narsee Monjee Institute of Management Studies (NMIMS)

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

The business transformation enabler. Precision Infomatic (M) Pvt. Ltd.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

RESERVE BANK OF INDIA (RBI) DEPARTMENT OF CURRENCY MANAGEMENT CITIZENS' CHARTER

SUNNY TRIPOWER 5000TL 12000TL

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

STRATO LED Drivers 70W, Single output

Technical Information Short-Circuit Currents Information on short-circuit currents of SMA PV inverters

Government of West Bengal Finance Department Pension Branch Writers Buildings, Block-IV 2 nd Floor, Kolkata

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

JoSAA 2016 : Course wise vacancy status after round 3 seat acceptance

32VFD Variable Frequency Drives for Centrifugal Chillers

ADVERTISEMENT. Sarfaesi Valuers who are already empanelled with the Bank need to apply afresh for continuing their empanelment.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Photovoltaic Solar Energy Unit EESFB

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Innovation Powers Efficiency

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA


/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE


Overall Ranking of Top B-Schools of India

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Financial Analysis of Solar Photovoltaic Power plant in India

Transcription:

Solar Inverters HIVERTER - NP201i Series

Solar Inverters HIVERTER - NP201i Series The Hitachi Solar Inverter is a Solar Inverter with reactive power control and high efficiency, which is the heart of the solar power generating system. It converts DC power generated by the photovoltaic (Solar) array to AC power that is fed to the utility power grid system. The Hitachi Solar Inverter is fully compatible with thin film and / or crystalline PV modules. With proper maintenance and parts replacement on schedule, it has an operating life up to 25 years. As a part of Hitachi Group Company, Hitachi Hi-Rel Power Electronics Pvt. Ltd is manufacturing Solar Inverters in India based on the contemporary technology of Hitachi Ltd, Japan. It brings reliable products supported by very high quality standards, manufacturing processes and work culture with assured long term technical and spares support. HIVERTER NP 201i, Hitachi Solar Inverter Series is among the best available GT Solar Inverters that is suitable for Multi-Megawatt Solar Power Plants. The transformer-less design and 3-level PWM technology improves the efficiency of the system to 98.7%. The Inverter has a compact design and lower weight for ease of installation, repair and maintenance. Large touch screen display collects the real-time data and provides fault detection diagnostics to ensure faster retrieval of information for corrective action. Hitachi's Presence in Indian Solar Domain Over 500 MW Hitachi Inverters feeding power to Indian grid in various states State-of-the-art manufacturing facility in India at Sanand and Gandhinagar in Gujarat Comprehensive testing facility with 100% load test Life cycle service support through Hitachi's pan India service centres Prompt availability of spares and components locally in India KW Solar Inverters MW Solar Inverters Highly Optimized Energy Conversion 02

Highlights Three level high frequency PWM Inverter technology resulting in reduction of losses, low harmonic output current (< 3%) & improved efficiency High efficiency up to 98.7% including filter losses IEC compliant / third party approval for entire range of Inverters Reactive power control Low Voltage Ride Through (LVRT) functionality Propriety MPPT algorithm / extra wide MPPT range (460 V - 900 V) Optimized cooling fan for higher energy savings as well as longer fan life Integrated DC and AC distribution & protection Independent RS 485 and TCP/IP communication interfaces Compact product design for lower footprint and ease of installation Designed lifetime up to 25 years - with preventive maintenance and periodic parts replacement Compliance Safety Testing Enclosure Protection Performance EMC Environmental Testing IEC 62109-1 IEC 62109-2 IEC 62116 UL 1741 IEC 60529 IEC 61683 IEC 61000-6-2 IEC 61000-6-4 60068-2-1 60068-2-2 60068-2-14 60068-2-30 PV Inverter general PV Inverter safety requirements Islanding system Safety IP protection Efficiency calculations Emission requirements Immunity requirements Cold test Dry heat test Change of temperature Damp heat cyclic test 99.5% 99.0% PV panel DC460 ~900V 72 INVERTER 42 6C 88F 52M AC 415V, 3-Phase Grid AC 300V 3Ø 3W Efficiency 98.5% 98.0% 97.5% 97.0% Control Circuit 96.5% Control Power Supply Circuit 8A 8G AC 240V, 1-Phase or DC110V 96.0% 95.5% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output Power Single Line Diagram of PV-Solar Inverters Output Power Vs. Efficiency Curve 03 www.hitachi-hirel.com

Solar Inverters HIVERTER - NP201i Series Control Functions Start / Stop Function (Emergency Switch) a. Inverter START / STOP switch or contact input signal (Start and stop of the Inverters is carried out by START / STOP switches). b. Control position can be selected by DIRECT / REMOTE switch. Direct Control Direct control of the Inverters is possible by using START / STOP switches. Remote Control Remote control of the Inverters can be done by contact input signals (START / STOP Switches) or communication. Fault Ride Through (FRT) Low Voltage Ride Through (LVRT) Against sudden changes of amplitude or phase of AC Voltage, Inverters high-speed detection and control capability can prevent AC over current. With the feature, the Inverters can keep operating even under momentary voltage dip of 60% for up to 0.5 seconds. Maximum Power Point Tracking (MPPT) Control Inverter has a function to maximize power generation at a given amount of solar radiation by adjusting DC voltage. Monitoring (Indicators) Inverter status measurement data, fault data, historical records and other information is displayed on the LCD screen. Status: Inverters Status l Switchgear Status l Grid Status Measurement AC Output : Voltage l Current l Power l Power Factor l Frequency DC Input : Voltage l Current l Power Fault Data : Inverters Failure l Grid Faults Historical Records Operation Record l Grid Trouble Record l Fault Record PV Input Controlled Stand-by Function a. When the DC input power or voltage reduces due to decrease in solar irradiation or any other causes, the Inverters goes into standby mode with its inverters switching functions turned off automatically. In this case, the DC switchgear will be closed. b. Upon recovery of the DC input the Inverters switching operation will be restored automatically. Output Power Limiting Function When the Hitachi inverters output exceeds its maximum value, the input power drawn will be adjusted to prevent the Inverters from being overloaded. Reactive Power Control 3 primary types of control methods Auto-tuning of power factor based on grid conditions Fixed power factor (can be set to unity) Fixed amount of reactive power Can be based on a pre-set value or based on adjustable settings Ease of Installation and Commissioning Low weight and compact footprint saves time and resources at site DC Input Panel Protection is provided for individual DC input with optional current monitoring feature. AC Output Panel AC Output panel with ACB and extended terminals for connecting the cable up to 500 SQMM AL. Inverter PV Power Station 1 MW, 2 MW & 2.5 MW Hitachi PV Power Station is an advanced containerised solution for large-scale and commercial PV (Photovoltaic) power plants, which contains Solar Inverters and optional equipments for auxiliaries, serves to protect electric equipments from environmental influence. Standard & robust design Easy connectivity to MV station IP53 protection class mechanism design Easy to transport Easy to install Highly Optimized Energy Conversion 04

Technical Specifications Solar Inverter Rating AC-DC Conversion System Control System Grid Data Power Rating AC Grid Connection Maximum AC Current Output Waveform THDi Nominal Output Voltage Output Frequency Range Transformer Peak Efficiency EURO Efficiency Power Factor (Adjustable) PV Side Maximum DC Power MPPT Voltage Range Maximum DC Input Voltage (OC) Minimum DC Input Voltage Maximum Input Current DC External Auxiliary Power Supply Control Power in Operation Control Power in Stand-by Mode Cooling Fan Power Protections Islanding Protection Temperature Protection Ground Fault Monitoring Grid Monitoring AC & DC Short Circuit and Over Current AC & DC Over Voltage and Temperature Cooling (Controlled) Fault Ride Through (FRT) Reducing Grid Voltage Fluctuation Control Automatic Wake-up and Shut-down Circuit Breaker on AC Side Switch on DC Side Communication Visual Display Wired Local Monitoring Unit-wise Integrated Data Logging Access Interface / Field Bus Connectivity Analogue Input / Output Digital Input / Relay Output Mechanical Dimensions (H x W x D) mm (Approximate) Weight (Kgs) (Approximate) Environmental Limits Enclosure Protection Temperature Range Relative Humidity Maximum Noise Level Altitude Cooling Air Flow 500 kw 630 kw 670 kw 3 level high frequency PWM Solar Inverter 500 kw MPPT and AC current control < 3% at rated current 50 Hz or 60 Hz ± 5% Transformer-less design 98.7% 98.4% 0.80 Lead to 0.80 Lag within max. kva limit DC 460 to 900 V DC 525 to 900 V DC 550 to 900 V DC 600 to 900 V 1000 V (Heavy failure protection level) 460 V 525 V 550 V 600 V 1200 A AC 230V, 1Φ, 300W, Max. 6.9A < 100 W AC 415V 3Φ, 400W Forced cooling Available operation will be continued in case of momentary voltage dip of residual positive phase. Voltage fluctuation due to power change at inter-connecting point will be reduced to within 2% LCD display with touch screen 1 x RS 485 or TCP/IP RS 485 or TCP-IP (Ethernet) 3 (Optional) 4 1900 x 1400 x 1000 1200 IP 20 (IP 21 Optional) (-) 20 C to (+) 60 C 15% to 95% (Non condensing) 75 dba at a distance of 1 Mtr (IEC 61672-1 Characteristic) 0 to 1000 Mtrs. (Option: 2000 Mtrs.) 3 3760 M /Hr. 715 kw 630 kw 670 kw 715 kw Three phase 1049 A 1107 A 1107 A 1107 A 300 V ±10 % 350 V ±10 % 370 V ±10 % 400 V ±10 % 600 kw 756 kw 806 kw 858 kw 05 www.hitachi-hirel.com

Solar Inverters HIVERTER - NP201i Series Technical Specifications Solar Inverter Rating AC-DC Conversion System Control System Grid Data Power Rating AC Grid Connection Maximum AC Current Output Waveform THDi Nominal Output Voltage Output Voltage Range Output Frequency Range Transformer Peak Efficiency EURO Efficiency Power Factor (Adjustable) PV Side Maximum DC Power MPPT Voltage Range Maximum DC Input Voltage (OC) Minimum DC Input Voltage Maximum Input Current DC External Auxiliary Power Supply Control Power in Operation Control Power in Stand-by Mode Cooling Fan Power Protections Islanding Protection DC Reverse Polarity Protection Temperature Protection Ground Fault Monitoring Grid Monitoring AC & DC Short Circuit and Over Current AC & DC Over Voltage and Temperature Cooling (Controlled) Fault Ride Through (FRT) (Also known as Low Voltage Ride Through (LVRT)) Reactive Power Control Automatic Wake-up and Shut-down Circuit Breaker on AC Side Switch on DC Side Communication Visual Display Wired Local Monitoring Unit-wise Integrated Data Logging Access Interface / Field Bus Connectivity Analogue Input / Output Digital Input / Relay Output Mechanical Dimensions (H x W x D) mm (Approximate) Weight (Kgs) (Approximate) Environmental Limits Enclosure Protection Temperature Range Relative Humidity Maximum Noise Level Altitude Cooling Air Flow 1 MW (1000 kw) 1000 kw 2214 A 300 V AC 300 V ± 10% 1200 kw DC 460 to 900 V 460 V 2400 A 3 level high frequency PWM Inverter MPPT and AC current control Three phase <3% at rated current 50 Hz or 60 Hz ± 5% Transformer-less design 98.6% at min DC Input Voltage 98.4% at min DC Input Voltage 0.80 Lead to 0.80 Lag within max. kva limit 1000 V (Heavy failure protection level) AC 230V, 1Φ, 300W <100W AC 415V 3Φ, 800W Forced cooling LCD display with touch screen RS485 Modbus / Modbus TCP-IP / TC P-IP over Ethernet RS 485 or TCP-IP (Ethernet) 3 (Optional) 4 2078 x 3800 x 1000 (Inclusive of AC & DC panel) 3000 IP 20 (IP 21 Optional) (-) 5 C to (+) 60 C (no de-rating up to 50 C; 1.5% de-rating per degree rise in temperature from 50 C to 60 C) 15% to 95% (Non condensing) 75 dba at a distance of 1 Mtr (JIS C 1509 Class 2 - A characteristic) 0 to 1000 Mtrs. (Option: 2000 Mtrs.) 3 7520 M / Hr. 1.25 MW (1250 kw) 1250 kw 2214 A 350 V AC 350 V ± 10% 1500 kw DC 525 to 900 V 525 V 2400 A Highly Optimized Energy Conversion 06

About Us Founded & established in 1983 as Hi-Rel Electronics Pvt. Ltd., we are now a Hitachi group company-hitachi Hi-Rel Power Electronics Pvt. Ltd., recognized as a pioneer in power electronics. With 3 decades of experience, we have garnered a significant level of trust in our market segment and continue to offer world class power electronics products, value added services & customized solutions. Our product portfolio includes UPS (uninterruptible power supply) for industrial, commercial & enterprise applications, medium voltage & low voltage variable frequency drives, steel automation & engineered drives for customized applications, industrial automation & control products like PLC, SCADA & DCS, SOLAR INVERTERS, railway products and other customized products like UMPS, I-dip (dip ride through solutions). Pioneer in power electronics Leading manufacturer of UPS, drives & automation products and solar inverters State-of-the-art manufacturing facility at Gandhinagar & Sanand in Gujarat, India In-house R&D facility recognized by DSIR, Government of India ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007 certified company with export house status Approved by leading consultants and EPC vendors Pan India & global presence Serving entire gamut of industries Rich experience in "mission critical" applications Dedicated & decentralized 24x7 after-sales-service Offers products with greater energy efficiency & lower carbon footprint With expertise, experience and an efficient product line, we will always be your power electronics partner. When you choose to do business with us, you are partnering with a company who cares. Gandhinagar, India Works 2 Total area - 10,000 m Products manufacturing - Industrial, Commercial & Enterprise UPS, Solar Inverters & Railway products Facilities - Designing, engineering, manufacturing and testing Sanand, India Works Most modern power electronics manufacturing facility in India Modelled on Hitachi's Omika Works, Japan 2 Total area - 26,000 m Products manufacturing - Medium & Low Voltage Drives, Solar Inverters, Industrial Automation & Control products, Customized Products i.e. UMPS, idip Facilities - Designing, engineering, manufacturing and testing Use of Hitachi's Omika works based software tools for engineering and manufacturing Dust free environment and anti-static flooring In-house Product Testing Facility 100% load test facility Test setup accredited by Intertek Facility for testing 150 MW per month 07 www.hitachi-hirel.com

Global & Pan India Presence USA Middle East Japan India South East Asia Africa Australia Jammu & Kashmir Jammu Amritsar Ludhiana Chandigarh Mandi Himachal Pradesh Punjab Jaipur Jodhpur Barmer Kanpur Gwalior Ajmer Udaipur Gandhinagar Ahmedabad Mehsana Sanand Mundra Jamnagar Rajkot Baroda Ankleshwar Surat Vapi Uttara khand Haryana Hisar Noida Lucknow Indore Bhopal Uttar Pradesh Rajasthan Maharashtra Nagpur Belgaum Siliguri Guwahati Gorakhpur Allahabad Muzzafarpur Gopalganj Arunachal Pradesh Ranchi Jorhat Sibsagar Meghalaya Bihar Sasan Korba Jharkhand Bokaro West Bengal Kolkata Jamshedpur Jajpur Angul Chattisgarh Bilaspur Cuttak Orisaa Bhubaneswar Raipur Bhilai Madhya Pradesh Gujarat Nashik Mumbai Pune Dehradun Moradabad Patna Agartala Hyderabad Vizag Rajahmundry Andhra Pradesh Bellary Kadapa Chennai Mangalore Coimbatore Karaikal Palakkad Tamil Nadu Kerala Tiruneveli Thiruvananthapuram Hitachi Hi-Rel Power Electronics Pvt. Ltd. Gandhinagar Works B - 14/1 & 171, GIDC Electronics Zone, Sector - 25, Gandhinagar - 382 044, Gujarat, India. Phone: +91-79-2328 7180/81, +91-79-6170 0500, Fax: +91-79-2328 7182 Sanand Works SM 3 & 4, Sanand - II GIDC, Industrial Estate, Bol Village, Sanand - 382 110 Gujarat, India. Phone: +91-2717-678777, Fax: +91-2717-678700 Email: contact@hitachi-hirel.com, Web: www.hitachi-hirel.com In the spirit of continuous improvement, specifications are subject to change without notice. Manufacturing Plant Corporate Office Branch Office Service Center Solar Inverter / 01 / 16 / Ver.1 / Corp. Mktg / India l Spotlight - 079 3002 2324 Karnataka Udipi Bangaluru