IQ Power & IQ Power HL

Similar documents
Everything you need for protection scheme testing

SNMP Web Management. User s Manual For SNMP Web Card/Box

SIMATIC S It s the interplay that makes the difference. SIMATIC Controller. Answers for industry.

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Release Notes. Contents. Release Purpose. Platform Compatibility. Licensing on the SRA Appliances and Virtual Appliance

Updating to Test Universe 3.0. What s new?

ABB PSPS Erich Steinmann; Generator control-2013

Permissible ambient temperature Operation Storage, transport

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Rev GSM base station. Installation instructions

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Product Information Sheet UH36 Hi Pot Tester

Nardalert S3 Non-Ionizing Radiation Monitor

5,000 lb Capacity. Wireless Communication Scale

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version

Dash 18X / Dash 18 Data Acquisition Recorder

NIM High Voltage Power Supplies

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

Mastertech Diagnostic Software Frequently Asked Questions

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

CAP 501. User s Guide

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Integration Guide. SafeNet Authentication Client. Using SAC CBA for Check Point Security Gateway

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Bedside Monitor BSM-9101K

User Manual. EtherUSB

PowerCommand iwatch 100

Easy Setup Guide for the Sony Network Camera

Automation and control

PowerCommand 500/550 Remote Monitoring System

Intelligent Mould Flow Monitoring

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Early Evaluation Center

Release Notes. Contents. Release Purpose. Platform Compatibility. Windows XP and Internet Explorer 8 Update

Square D Model 6 Motor Control Centers

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Auto-Tune for Software Manager Version 1.1.0

Cat Detect. for Surface Mining Applications

Wireless LAN g USB Adapter

Release Notes. Contents. Release Purpose. Platform Compatibility. Windows XP and Internet Explorer 8 Update

How To Build A Home Automation System On A Tv Remote Control

Iso-Gard Series 6 Line Isolation Monitors

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

White Paper April 2006

Dash 8Xe / Dash 8X Data Acquisition Recorder

The SOLUTION for Gathering Rotary Torque Sensor with Encoder Data

Digital multimeters DMG

WIRELESS INSTRUMENTATION TECHNOLOGY

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

DS-7208HVI-ST Series DVR. Technical Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

EtherDevice Switch EDS-726 Series

PLC training panel (Twido version)

Greenline Industrial Monitors IMD-C Series. User Manual

Authorware Install Directions for IE in Windows Vista, Windows 7, and Windows 8

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Supervision software for Intrusion detection, Fire detection and CCTV systems

PITE 3921 Battery Monitoring System User Manual P V1.0

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Wireless DMX Connector

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

3500/93 System Display

Windows Vista / Windows 7 Installation Guide

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SMART Board 8055i and 8055i-SMP

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

The integrated HMI-PLC

Streamline NX. Capture, Distribution & Output Management Solution

An overview of Computerised Numeric Control (C.N.C.) and Programmable Logic Control (P.L.C.) in machine automation

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Temperature & Humidity SMS Alert Controller

Workshop 7 PC Software - Tracker

UNIT White Paper (November 2009)

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Xerox Multifunction Devices. Verify Device Settings via the Configuration Report

User manual Rev 1.3 Contents

What is our purpose?

Centro-Matic Automatic Lubrication Systems System Controls

1 Application Description Objective Goals... 3

Semaphore T BOX Applications in Data Center Facilities

Network Management Card. User Manual

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

How To Use An Ip Phone With A Cell Phone With An Ip-Phone With A Sim Sim Card (Iphone) For A Long Distance Call (Phone) Or A Cellphone (Phone Phone) For An Unlimited Time (Phone, Cell Phone

Wireless Data Logger Monitoring Systems

Features. Emerson Solutions for Abnormal Situations

Aastra 67xi Series. Aastra 6730i. Aastra 6731i. Aastra 6735i

Aastra SIP Telephones

PowerPanel Business Edition USER MANUAL

Network Video Recorder Quick Operation Guide

Configurable Events for APC Network Management Card

Transcription:

W W W. S I M C O - I O N. C O M Industrial Static Control IQ Power & IQ Power HL STATIC NEUTRALIZING SYSTEM

IQ Power The Most Advanced Static Neutralizing System The IQ Power Static Neutralizing System and IQ Power HL for Hazardous Locations, is an unparalleled lineup engineered with the technology that brings complete monitoring intelligence with a user friendly interface. Designed for use in rugged industrial applications and leveraging many patented features, the IQ Power provides exceptional ionization performance. Security enabled, configurable parameters allow the user to understand and control their static neutralization challenges through a user-friendly interface and microprocessor controlled touchscreen. This fully integrated system makes installation a snap. No complicated software to install or maintain. There s no need to figure out firewalls and installation issues, or which browser to use. The IQ Power System incorporates several relay output choices to suit desired alarm methods for streamlined operation and maximum productivity. Global relays as well as individual IQ Power BPS relays are accessible for both warning and fault user selectable alarm thresholds. Incorporating the latest in ionization technology, the IQ power control station is equipped with a full color touch panel interface. The control station allows the user to configure global and localized settings for up to 10 devices and offers single point monitoring for each device. No power sources available? No problem, as the IQ Power Control Station can provide full power and communications for up to 6 neutralizing devices. The Control Station provides three Output Modes of operation to manage the output polarity: Fixed Mode for system optimization based on average web conditions. Manual Mode for user adjusted output settings. Auto-Tune Mode a patented feature for consistent live web reading and optimization based on current conditions. Output Modes

Static Neutralizing Bars The IQ Power static neutralizing bars consist of current-limited emitter points which eliminate operator shocks. The system offers over 85 different lengths of industrial-designed static bars that are available in four varieties to suit the application based on the web speeds or operating distance. All bars include rugged mounting hardware. Speed Static Bars are engineered to neutralize static charges on webs traveling up to 3,000 fpm and are mounted approximately 4 from the material to be neutralized. Operating at 7 kv. Speed Bars available for Hazardous Locations. Speed-T Static Bars are the latest addition to our static bar lineup and feature tungsten emitters for long life. Operating at 7 kv. Hybrid Static Bars are designed for installations where the distance between static bar and material to be neutralized changes during the process and up to 18 away. Operating at 9 kv. Hybrid Bars available for Hazardous Locations. Distance Static Bars are specially engineered to provide powerful ionization for distances up to 30 inches from the web in applications where installing a static bar close to the web is not an option. Operating at 12 kv. IQ Power HL Static Bar Available in Speed and Hybrid IQ Power Static Bar Available in Speed, Hybrid and Distance Static Bar Types Operating Voltage: 7 kv Emitter Spacing: 30 mm Operating Voltage: 9 kv Emitter Spacing: 90 mm Operating Voltage: 12 kv Emitter Spacing: 180 mm

Control Station Data logging is sometimes necessary in critical areas. Therefore, the IQ Power Control Station incorporates user selectable time interval data points in addition to event logging capabilities. Couple that with simplified data retrieving methods via USB or FTP for ultimate convenience. The Control Station provides operating details of each device in the system upon clicking on the individual icons from the Global View screen. Device details include system name, status, output and current. Also shown are upstream and downstream charge indicators for operator safety and verification. An optional web speed encoder can provide automatic web speed readings if desired. Color coordinated icons and output readings are designed to notify operator of device status. Control Station Connections

BPS Power Supply The heart of the system is the IQ Power BPS and HL Power Supply. This industrial powerhouse provides patented one touch calibration, and full ionization output readings. No fumbling with pots or trying to figure out if your bar is even working. The 24 VDC input power enabled provides low voltage connections. With clearly displayed power, clean bar, fault and communication indicators there s no guesswork required. The patented connector system automatically senses bar type to adjust frequency and voltage. No configuration required. In installations where a machine system is in place, the IQ Power s Communication Module provides simplified full PLC integration with various protocols available. Offering upstream and downstream charge readings, balance optimization, the IQ Power system is engineered to allow users to operate the system in the mode that meets their needs. IQ POWER System Advantages Patent-pending Auto-Tune technology Complete system monitoring for up to 10 power supplies Patented Dual-Axis control Patented One-touch self calibration Patented HV Power supply connector system System control, global or by device Low 24 VDC input power Fully serviceable modular system Neutralizing ability up to 30 inches Customizable data logging and retrieval Optional tungsten emitters for long life Full PLC integration The full IQ Power system is also available and approved for hazardous location installations, Class 1, Div 1.

Control Station Views The core of the IQ Power System is the Control Station which includes a full color touch screen designed with an intuitive interface and userfriendly features that help you monitor and control the system globally or by device. Set parameters for the whole system from one convenient location. Instantly view live operating conditions of all neutralizing devices in the system. Adjust settings easily with a fully functional touch screen keyboard. View individual settings for each neutralizing device connected to the system. Individually adjust each neutralizing device in the system.

The IQ Power and IQ Power HL Systems can monitor up to ten devices in one complete network through the touch screen Control Station. Full integration into an existing industrial PLC is provided via the IQ Power Communication Module, streamlining system functionality. Full IQ Power Network

Simco-Ion Industrial Group 2257 North Penn Road Hatfield, PA 19440 2014 Simco-Ion All rights reserved. 5201213 Rev D w o r l d w i d e l e a d e r s i n s t a t i c c o n t r o l