Contents

Similar documents
1 General information

1. Safety information

Drayton Digistat +2RF/+3RF

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

RESOL DeltaSol A. Mounting Connection Operation Examples. Manual

Contents. Operation manual of solar water controller SR868C8/SR868C8Q

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SWIMMING POOL HEAT PUMP Owners Manual

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ELECTRIC CENTRAL HEATING FLOW BOILER

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

HERZ-Thermal Actuators

EK908FHL - Thermostat for floor heating

Split Controller. User Manual SM-SS-F 2009/01/04

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

User s Manual Before using the inverter, you need to read and save the safety instructions.

Overheating limit control

INSTALLER S & OWNER S MANUAL

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Solar Hot Water Heaters

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Duct Humidity Transmitter

Operating manual For split pressurized solar hot water system controller

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Aerona Air Source Heat Pumps

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Installation, operation and maintenance manual TX 35A

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

User Manual THR840DUK Digital Thermostat

SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

ALL IN ONE. Heat Pump Water Heater

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

T0118 T2118 T3118. Instruction Manual

Hygro-Thermometer + InfraRed Thermometer Model RH101

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Unit 24: Applications of Pneumatics and Hydraulics

USER S MANUAL HSC-24A

Installation and maintenance instructions. Danfoss Vent

M A N U A L

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Advantium 2 Plus Alarm

What you can expect from your Solar Hot Water System

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Failure code manual. content

Neuton Solar Power Diverter Quick Installation Guide

=============================== WARNING

Operators manual Basic water heater

Portable Air Conditioner

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

AIR CONDITIONER INSTALLATION MANUAL

SELECTION, APPLICATION AND MAINTENANCE

Wind Sensor W-RS485 with RS485 Interface

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

OPL BASIC. Dosing System for Professional Laundry machines. Contents

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Manual. Solar Fountain Mobile Phone Charger

Series description: Wilo-Star-Z

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Model UT201/202: OPERATING MANUAL. Table of Contents

Installation Instructions. Thermo Call TC3

Operating Manual Color Changing Fountains

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Thermo Top - Troubleshooting Tree

Instruction manual for Firstline FCS12000CH

Reverse Cycle Inverter Split System Air Conditioner

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User Manual. Video Doorphone CDV-1020AQ

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Luna 3 Comfort Troubleshooting Guide June 2008

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

INFRARED QUARTZ WALL HEATER

MIC-WKT and MIC-WKT-IR

TC-9102 Series Surface Mount Temperature Controllers

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Installation Instructions. ThermoCall TC4. Entry/Advanced

ELECTRIC INSTANTANEOUS WATER HEATER

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Manual Ranging MultiMeter

Transcription:

Contents Contents-----------------------------------------------------------------------------------1 1. Safety information ------------------------------------------------------------------3 1.1 Installation and commissioning--------------------------------------------------3

Contents Contents------------------------------------------------------------------------------------1 1. Safety information---------------------------------------------------------------------3 1.1 Installation and commissioning--------------------------------------------------3 1.2 Liability waiver------------------------------------------------------------------------3 1.3 Description of symbols-------------------------------------------------------------4 2.Installation-----------------------------------------------------------------------------4 2.1 Installing the controller-------------------------------------------------------------4 2.2 Power connection -------------------------------------------------------------------5 2.3 Terminal connection ---------------------------------------------------------------6 2.4 Installing electromagnetic valve ------------------------------------------------7 2.4.1 Faults checking of electromagnetic valve----------------------------------8 2.5Installation of water level and temperature sensor 2.5.1Installation of Silico-Sensor(B03) -----------------------------------------9 2.5.2 Installation of Ion-Sensor(B01 or B02)------------------------------------9 2.5.2.1 Diagram of cable connection for Ion-Sensor(B01 or B02)-- - -----------------------------------------------------------------------------------------------10 2.5.2.2 Anti-overflow probe installation for Ion-sensor instructions---- ------------------------------------------------------------------------------------------------11 3.Introduction of solar system--------------------------------------------------------12 4.Instruction of display illustration---------------------------------------------------13 4.1 Screen display instruction--------------------------------------------------------13 4.2 Code instruction---------------------------------------------------------------------13 5.Functions and Operation------------------------------------------------------------14 ~ 1 ~

5.1 ON/OFF button-------------------------------------------------------------------14 5.2 Water loading ---------------------------------------------------------------------14 5.3 Water supply function when lack of water----------------------------------15 5.4Timing control water loading ---------------------------------------------------15 5.5 Temperature control water loading ------------------------------------------16 5.6 Hot water circulation -------------------------------------------------------------16 5.7 Insulation by Tem. controlled --------------------------------------------------17 5.8 Insulation by time controlled ---------------------------------------------------18 6. Protection Function-----------------------------------------------------------------19 6.1 Collector high temperature protection----------------------------------------19 6.2 Low water pressure protection-------------------------------------------------19 7.Technical data------------------------------------------------------------------------20 8. Delivery scope-----------------------------------------------------------------------20 9.Quality Guarantee-------------------------------------------------------------------21 ~ 2 ~

1. Safety information 1.1 Installation and commissioning When laying cables, please ensure that no damage occurs to any of the constructional fire safety measures presented in the building. The controller must not be installed in rooms where easily inflammable gas mixtures are present or may occur. All devices connected to the controller must conform to the technical specifications of the controller. All operations on an open regulator are only to be conducted cleared from the power supply. All safety regulations for working on the power supply are valid. Connecting and /or all operations that require opening the regulator (e.g. changing the fuse) are only to be conducted by specialists. 1.2 Liability waiver The manufacturer cannot monitor the compliance with these instructions or the circumstances and methods used for installation, operation, utilization and maintenance of this controller. Improper installation can cause damages to material and persons. This is the reason why we do not take over responsibility and liability for losses, damages or cost that might arise due to improper installation, operation or wrong utilization and maintenance or that occurs in some connection with the aforementioned. Moreover we do not take over liability for patent infringements or infringements occurring in connection with the use of this controller- on third parties rights. The manufacturer preserves the right to put changes to product, technical date or installation and operation instructions without prior notice. As soon as it becomes evident that safe operation is no longer possible (e.g visible damage). Please immediate take the device out of operation. Note: ensure that the device cannot be accidentally placed into operation. ~ 3 ~

1.3 Description of symbols Safety instruction: Safety instructions in the text are marked with a warning triangle. They indicate measures, which can lead to injury of persons or safety risks. Note:Contains important information on operation or function. 2.Installation 2.1 Installing the controller Note: the controller can only be installed in an area having an adequate level of protection. Fixing the hang-panel of controller Choose a suitable site Mark the position of hole Drill the fixing hole, insert the expansion screw Take away the cover Put bottom plate one the position of Market the hole of and Then take away of bottom plate again. Drill the fixing hole. Rehang the bottom plate and fixing on Insert the screw,fixing hole and on the bottom plate. ~ 4 ~

2.2 Power connection Power can only be switched on when the house of controller is closed, an installer must make sure that the IP protection class of the controller is not damaged during installation. Depending on the type of installation, the cables may enter the device through the rear hole of the case 4or the lower side hole of the case 5 Cable come from the rear 4: remove the plastic flaps from the rear side of the case using an appropriate tool. Cable come from the below5: cut the left and right plastic flaps using an appropriate tool (e.g. knife) and break them out of the case. Notes: the flexible wire must be fastened on the case using the clamps provided ~ 5 ~

2.3 Terminal connection Before to open the terminal, please be sure to switch-off the power supplier and pay attention to the local electricity supply rules. Terminal Layout. Power Connection 1. Please note the type of power supply required from the type plate on the case of the device 2. The protective conductor (GND)which two colors must be connected also. Inputs: T, 1&2&3 1.Port T: Temperature sensor for heating cable(ntc10k) 2.Water level and temperature sensor input: 1)If siliconsensor(b01 or B02) was connected on Port1: connect red wire Port2: connect white wire Port3: connect black wire 2)If ion-sensor(b03) was connected on Port1: Outputs: P1,P2, R1 1.Output P1: Electromagnetic relay, for pressure increasing pump, max. switching current: 5A 2.Output P2: electromagnetic relay, maximal switching current: 5A, P2 is used for electrical heating cable 3.Output R1: for electromagnetic vale of loading water, outlet voltage:dc12v ~ 6 ~

connect red wire Port2: connect white wire Port3: connect black wire 2.4 Installing electromagnetic valve Before installing electromagnetic valve, please clean up and wash pipe. If water is provided by water tower, please select electromagnetic valve, which caters the water pressure of water tower. So to avoid the low flow rate or even no water flows from electromagnetic valve. Check whether the output voltage of controller caters to the label voltage of electromagnetic valve; check whether the filter net is completed, whether the body of electromagnetic valve is completed. Outlet and inlet of electromagnetic valve should be right installed, the side with filter net is input, and water flow direction should be same as the arrow which marked on the body of electromagnetic valve. Electromagnetic should be installed in the place where is easy to maintain and does not bring other lose, please take measures for anti-freezing, anti-sunburn and therefore to avoid aging of body of valve and to prolong the lifetime of valve. Please pay attention to install the wire coil upwards. It is forbidden to use wrench to work on the wire coil and on plastic part. The inlet and outlet pipe of electromagnetic valve should be keep at a same level, and ensure not to mount valve compulsively when both connection parts are not at a same level, and therefore to avoid damaged of valve. It should be noted that installed valve doesn t bear the torsional strength which caused by wrong mounted pipe. Two-cores wire should be connected with electromagnetic valve, when wire need to be prolonged, please select 1.0mm 2 cable. The pipe, which is connected with valve, should be easy to dismount or use flexible pipe, it should be easy to clean the filter. ~ 7 ~

Switch-on power and check valve after installation. Note: electromagnetic valve has check-valve function, it is not necessary to install one way valve any more. 2.4.1 Faults checking of electromagnetic valve Reasons of fault Checking measures Error rectification Wire connection is Check wire Re-connect wires not good connection Whether wire coil of electromagnetic valve has power Operation voltage is unstable Water pressure is less than 0.012Mpa Measure the resistance with Ohmmeter Measure voltage Open the tap and estimating Change wire coil or change valve if necessary Change input power resource Installing a pressure increase pump or change a new valve with lower water pressure Filter is stopped Check optically Regular wash filter Water pressure is high than 0.8Mpa Open the tap and estimating Installing a pressure reduction pump or change a new valve with high operational voltage (about10% more) ~ 8 ~

2.5 Installation of water level and temperature sensor 2.5.1 Installation of Silico-Sensor(B03) Insert silicon-sensor(b03) into overflow outlet of solar tank. Tighten the sensor screw Connecte same color wires correspondingly. Red wire(+12v) White wire (COM) Black wire (GND) Note: In order to avoid measuring error of tank temperature, water level and temerature sensor can t touch the electrical heater or is too near to electrical heater 2.5.2 Installation of Ion-Sensor(B01 or B02) Installation of bottom sensor(b02) Insert the bottom installed sensor(b02) into tank from bottom hole, fasten sensor. Make sure no water leak. Note: The distance between overflow hole and tip of sensor should be around at 1cm to 2cm. See picture 1 ~ 9 ~

Installation of top sensor(b01) Insert the top installed sensor(b01) into tank from top hole, fasten sensor. See picture 2 Note: 1. Sensor is suitable for tank, which diameter of inner tank is 350mm 2. Sensor is installed inside tank, it works under high temperature, high humidity and scale conditions and thereof to be damaged easily, so sensor is damageable depart, its quality guarantee is valid within 12 months from the purchasing date. 2.5.2.1 Diagram of cable connection for Ion-Sensor(B01 or B02) Port 1 connected with red wire ( +12V) Port 2 connected with white wire ( COM) Port 3 connected with black wire ( GND) Port3 and port4 connected with overflow Probe(Port3 connected white,port4 connected red) Connection cable should be leaded into building; the outside exposed part should be fixed properly to avoid damage of cable. ~ 10 ~

2.5.2.2 Anti-overflow probe installation for Ion-sensor instructions In order to avoid Bring about overflowing water due to water level sensor from checking abnormally when solar tank is loading water, install a overflow probe at the overflow hole and ensure that water in solar tank can not overflow, to avoid bringing about unnecessary lose and to get double insurance. screw the overflow probe into tank through the overflow port, which positioned on the side of tank, note the direction of probe, flat side upwards.(see the picture) The white one of overflow probe connect to port3,and red one to port4(details see paragraph 2.5.2.1) Then close the back cover. Note: If B01(or B02) was installed on system,overflow probe is necessary installation. ~ 11 ~

3.Introduction of solar system Description: this system is water and collector integrated solar water system, it is easy for mounting, and efficiency is high. ~ 12 ~

4.Instruction of display illustration 4.1 Screen display instruction 4.2 Code instruction Code E0 E4 E6 E7 Code explanation Connection cable between controller and sensor fault Collector pipe high temperature protection Temperature senor fault Water level sensor fault ~ 13 ~

5.Functions and Operation Under cut off power supply,connection sensors, pump or solenoid valves to the controller! 5.1 ON/OFF button After power is switched-on, as default set controller is open, and controller displays water temperature and water level, all functional buttons are ready for setting operational parameters. After controller is open, press on/off button, then controller entries into close mode, after two 2 hours controller recovers to work again. Automatically water loading under Auto mode: When water temperature is over 60 o C and water level is at 20% position or at 50% or 80% position, 10 minutes later it starts to load water, but in the case when man is using water (water level is changing) it starts to load water 60 minutes later. When water temperature is lower than 55 o C or when water level raises up to 100% position, then it stops to load water. When water level drops due to using water, tank appears the status of lack of water, and then it starts to load water to desired position after 30 minutes. 5.2 Water loading Functional description: When water isn t full in tank, and user wants to start water load immediately, it can be achieve by press"water load" button to start manual water loading function Activate and deactivate function: press"water load" button,water loading signal displays. Water level area blinks, press"water load" button continuously to set desired water level ( 50% - 100%) ~ 14 ~

press"water load" button again to deactivate function. Note: Water level of loading can be set by user. First time loading of new installation,there is some water overflow,it's normal operation by controller. Or power off suddenly during the using,these is some water overflow when power on again,it's normal operation by controller. 5.3 Water supply function when lack of water Functional description: Water level from high to lower, when water level lower than 20% postion, delay 30minutes,then loading water to preset position(water level setting:see paragraph5.2;fatory default:20%) 5.4Timing control water loading Functional description: Timing load button is used to set the time for triggering the water loading. Press Timing load button continuously to set the desired time for triggering water loading,( adjustable time range 1-23 hours). For example: if now is 8 o'clock AM, but you want to load water at 4 o'clock PM, then press this button until 08 disappears on screen, that means controller will start to load water 8 hours later automatically. After setting an indicating light blinks, 3 seconds later controller confirms the setting, and the Indicating light of this function is on. After the setting, you can press this button to check how long time is left to the preset water loading time. Press this button again to cancel this function. System has memory function,in the condition that power of controller isn't switched-off, your setting will be remember, it is not ~ 15 ~

necessary to set every day. During the water loading process, press Timing load button again, it can stop the water loading immediately. When the symbol" " light on screen,"timing load" function is activated. 5.5 Temperature control water loading Functional description: When this function is activated, water will be loaded according to preset loading temperature. In the case that water tank isn t full, when tank temperature is above the preset loading temperature, controller starts to load water automatically until tank temperature drops to 5 o C below the loading temperature. In the case that water level is changed in the same, then water loading will be started after 60 minutes, doing like this can avoid water temperature changes so acutely and therefore avoid uncomfortable feeling for customer. Press "tem. Load" button continuously to adjust the desired temperature for triggering water loading, adjustable range is "35 o C ~95 o C", default value is 55 o C, 3 seconds later controller confirms the setting. The indicating light of temperature controlled water loading is on. When the water temperature is higher than the preset temperature of tank, water loading is started, when the water temperature drops 5 o C below the preset temperature, water loading is stopped. Press this button again to cancel this mode. When the symbol" " light on screen,"tem.load" function is activated. 5.6 Hot water circulation Function description: The controller support the function that time-controlled hot water circuit ~ 16 ~

pump. It s asked to add one circuit pump (P2),user can set operation time of pump, to achieve hot water and water pressurized will come soon. Press "circulation" button continuously to adjust the operation time for circulation pump(adjustable time range is 1-30 minutes) and default value is 3 minutes. After 3 seconds controller confirms the setting, and indicating light of " " is on, press this button again to switch off circulation pump during the operation of circulation pump. 5.7 Insulation by Tem. controlled Functional description: In Winter when ambient temperature is low, in order to avoid freezing pipeline.when test the temperature(t) on the pipeline less than turning on temperature(1 o C),activate the accompany electrical heating cable(p2). When test the temperature(t) on the pipeline more than turning on temperature(5 o C),deactivate the accompany electrical heating cable(p2). For example:if setting turning on temperature was 1 o C,so when T drop to 0 o C active the P2.When T rise up to 6 o C deactivate the P2. (Doing like this can save electricity, prolong the lifetime of heating wire and avoid fire accident which caused by aging electrical heating wire.) Activate/deactivate function: press "Insulation" button, Insulation signal and temperature blinks on displays,the function is activate. press "Insulation" continuously,to adjust switch-on temperature(adjustable:0-99 o C) After setting,3seconds later,the controller activate insulation function. press "Insulation" button again to deactivate function. When the symbol" " light on screen,the function activated. Note: Temperature sensor(t) not belong to standard delivery scope,user ~ 17 ~

who want to use this function need to buy it(t) with extra Without installation sensor(t),the function was deactivated automatically. Hot water circulation pump and pipe insulation function are controlled by a same output P2, when use pipe insulation function, P2 outlet is used, then thermostat hot water supply function will be deactivated automatically. 5.8 Insulation by time controlled In Winter when ambient temperature is low, in order to avoid freezing pipe man can press "Insulation" button to activate accompany electrical heating cable ( P2) to heat pipe. When this function is activated, electrical heating wire will works for 10 minutes(factory default,can not adjustable) and then stops for 30minutes(can adjustable), this process repeats. Doing like this can save electricity, prolong the lifetime of heating wire and avoid fire accident which caused by aging electrical heating wire. Activate/deactivate function: press "Insulation" button, Insulation signal and time blinks on displays,the function is activate. press "Insulation" continuously,to adjust switch-off time(adjustable:0-99mins,factory default "00",mean that accompany electrical heating cable always "power on") After setting,3seconds later,the controller activate insulation function. press "Insulation" button again to deactivate function. When the symbol" " light on screen,the function activated. Note: Hot water circulation pump and pipe insulation function are controlled by a same output P2, when use pipe insulation function, P2 outlet is used, then thermostat hot water supply function will be deactivated automatically. ~ 18 ~

6. Protection Fuction 6.1 Collector high temperature protection Functional description: In the status that there is no water inside tank, and tank temperature is over 99 o C, then water-loading button is invalided, and E4 displays on screen, water loading is complete stopped until tank temperature drops below 80 o C. Doing like this can avoid breaking collector pipe, which caused by large temperature difference. 6.2 Low water pressure protection Functional description: During the water loading mode, because of low water pressure or no water flow rate ( when water level can rise 1 level within 60minutes, then it means no water flow rate) controller will entry low water pressure protection mode automatically, low water pressure signal displays, after 30 minutes, controller exit program automatically. Doing like this can avoid damaging of electromagnetic valve, which caused by long operation, and avoid water flows back from tank to pipe. ~ 19 ~

7.Technical data Appearance of controller: see product itself ( dimension: 180mm x120mm x40mm) Power supply:ac230v±10% Power consumption:< 3W Accuracy of temperature measuring: ± 2 o C Range of tank temperature measuring: 0 ~99 o C Range of temperature display: 0~ 99 o C Can connect loading pump:1pc < 600W Can connect electrical heating cable:1pc < 800W Ambient temperature :-10 o C ~ 50 o C. Water proof grade:ip41. Socket : choice by customer 8. Delivery scope Controller-------------------------------------------------------------------- 1 piece Customer manual----------------------------------------------------------1 piece Water level and temperature sensor----------------------------------1 piece Overflow probe--------------------------------------------------------------1 piece Solenoid valve---------------------------------------------------------------1 piece M6 Plastic expansion screw-------------------------------------------- 3 pieces Ø4*30 flat screw------------------------------------------------------------ 3 pieces Power cord-------------------------------------------------------------------1piece ~ 20 ~

9.Quality Guarantee Manufacturer provides following quality responsibilities to end-users: within the period of quality responsibilities, manufacturer will exclude the failure caused by production and material selection. A correct installation will not lead to failure. When a user takes incorrect handling way, incorrect installation, improper or crud handling, wrong connection of sensor in system and incorrect operation, the quality responsibility is invalid for them. The warrantee expires within 12 months after the date of purchasing the controller. ~ 21 ~