Innovation on Medium Voltage Switchgear

Similar documents
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

UFES Active protection for switchgear

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Arc Terminator Active Arc-Resistant Switchgear

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

How To Make A Power Supply From A Power Generator

The Intelligent AX1 Switchgear for Medium Voltage

Unified requirements for systems with voltages above 1 kv up to 15 kv

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Sample - No Commercial Use

Choosing for tranquility

Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Secondary Unit Substations

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

Enhancing Personnel Safety with Arc Resistant Equipment

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Session Four: Internal Arc Safety in New and Existing Switchgear

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

Catalog. Arc Guard System TM TVOC-2

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Permissible ambient temperature Operation Storage, transport

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Securing your electrical installations Prisma,

SENTRON Switching and Protection Devices Air Circuit Breakers

Part 1 System Modeling & Studies for Existing Systems

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

The following components are common to most cubicles; this example is an ABB HK cubicle.

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

21 st Century Facilities

Chapter 1. Network Structures

MNS is Switchgear System Technical Overview

Electrical Shore Connections / Cold Ironing

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Design of a New Generation of Internal Arc Resistant Switchgear

CAS 36 Ring Main Unit

SIVACON The Versatile Low-Voltage Switchboard

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Arc Flash Energy Mitigation Techniques

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

How To Choose A Transformer

A seismic switch. Certified switchgear for nuclear power plants is providing a critical link in the chain

Comparative study for cables and busbars

Safe and secure distribution of medium voltage with AX1

Switchgear and Metal-Enclosed Bus

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

SURGE PROTECTIVE DEVICES

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Medium Voltage Switchgear

Automation Products. Low Voltage Switchgear MNS System Overview

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Engineering Specification

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

IEC in ZX Gas-insulated medium voltage switchgear

Advantages of Fixed Circuit Breaker Switchgear

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

DS1 Diode-based transient-free capacitor switch

Electronic overload relay EF65, EF96 and EF146

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Medium Voltage technical guide. Basics for MV cubicle design

Medium voltage indoor circuit breakers ANSI/IEC solutions

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear. Internal Arc Proof

ABB PSPS Erich Steinmann; Generator control-2013

Arc Protection Relay REA 101. Operator s Manual

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

FAQs-Main switchboard design criteria

P System Cubicles. Certified for more safety

Mitigation of Arc-Flash Hazards and Reduction of Costs by Selective Arc-Flash Protection

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Medium voltage switchgear Withdrawable vacuum circuit-breaker 1 to 17.5 kv. Catalogue. Web enabled Power & Control. MCset

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Arc Protection Relay REA 10_. Product Guide

Transcription:

Bruno Rivas, Guarulhos - Brazil, April 2015 Jornadas Técnicas de ABB en Perú Innovation on Medium Voltage Switchgear May 5, 2015 Slide 1

Application 5. Mai 2015 Slide 2

Unigear ZS1 Design concepts: Single Busbar System Back to Back System Double Level System May 5, 2015 Slide 3

Unigear ZS1 Single Busbar System May 5, 2015 Slide 4

Unigear ZS1 Single Busbar System Electrical characteristics Rated voltage Test voltage (50-60 Hz/1 min) Impulse withstand voltage Rated frequency Rated short-time withstand current Peak withstand current Internal arc withstand current Rated current of the main busbars Rated circuit-breaker thermal current Feeders rated current [kv] [kv] [kv] [Hz] [ka] [ka] [ka] [A] [A] [A] Up to Up to Up to Up to Up to 12 12 (*) 28 75 50-60 50 60 125 50 125 50 4000 50 4000 4000 4000 630 1250 630 1250 1600 1600 2000 2000 2500 2500 3150 3150 3600 3600 4000 4000 17,5 38 95 50-60 50 125 50 4000 4000 630 1250 1600 2000 2500 3150 3600 4000 24 50 125 50-60 31,5 80 31,5 3150 3150 630 1250 1600 2000 2500 3150 May 5, 2015 Slide 5

R L Unigear ZS1 Single Busbar System May 5, 2015 Slide 6

Unigear ZS1 Double Busbar System Double Level; Double Level Duplex. May 5, 2015 Slide 7

Unigear ZS1 Double Busbar System Electrical characteristics Rated voltage Test voltage (50-60 Hz/1 min) Impulse withstand voltage Rated frequency Rated short-time withstand current Peak withstand current Internal arc withstand current Rated current of the main busbars Rated current branch connection [kv] [kv] [kv] [Hz] [ka] [ka] [ka] [A] [A] Up to Up to Up to Up to 7,2 20 60 50-60 50 125 50 1600 630 12 28 75 50-60 50 125 50 1600 630 17,5 38 95 50-60 40 100 40 1600 630 1000 1250 1600 1000 1250 1600 1000 1250 1600 May 5, 2015 Slide 8

R L R L Unigear ZS1 Double Busbar System May 5, 2015 Slide 9

R L Unigear ZS1 Double Busbar System May 5, 2015 Slide 10

R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L R L Unigear ZS1 Double Busbar System Metering unit Metering unit Outgoing feeders with circuit breakers Outgoing feeders with contactors Incoming feeder Bus tie Bus riser Incoming feeder Outgoing feeders with contactors Outgoing feeders with circuit breakers Earthing transformer outgoing Earthing transformer outgoing May 5, 2015 Slide 11

Unigear ZS1 Back to Back System May 5, 2015 Slide 12

Unigear ZS1 Back to Back System Electrical characteristics Rated voltage Test voltage (50-60 Hz/1 min) Impulse withstand voltage Rated frequency Rated short-time withstand current Peak withstand current Internal arc withstand current Rated current of the main busbars Rated circuit-breaker thermal current Feeders rated current [kv] [kv] [kv] [Hz] [ka] [ka] [ka] [A] [A] [A] Up to Up to Up to Up to Up to 12 12 (*) 28 75 50-60 50 60 125 50 125 50 4000 50 4000 4000 4000 630 1250 630 1600 1250 2000 1600 2500 2000 3150 2500 3600 3150 4000 3600 4000 17,5 38 95 50-60 50 125 50 4000 4000 630 1250 1600 2000 2500 3150 3600 4000 24 50 125 50-60 31,5 80 25 2500 2500 630 1250 1600 2000 2500 May 5, 2015 Slide 13

Unigear ZS1 Back to Back System May 5, 2015 Slide 14

Safety 5. Mai 2015 Slide 15

Safety ABB Month DD, YYYY Slide 16

Safety The most complete range Complies with IEC Standards; GOST (Russia); GB (China) as well as main Shipping Registers Regulations Type tested Fully type tested according to IEC standard; Additional tests performed in compliance with shipping registers regulations; Specifically tested to be in compliance with several local requirements (e.g. GOST and GB); Seismic: IEC (IEC 68-2-6 / 68-2-57), IEEE standards (IEEE Std. 693-1997) and ETG-1020 (by calculation). Inclination test Vibration test May 5, 2015 Slide 17

Safety PM (partition metallic) and LSC2B (Busbar, feeder and apparatus compartments physically and electrically segregated) classified according the IEC 62271-200; Complete of safety mechanical interlocks (interlock-controlled or tool-based accessible compartments); Metallic shutters operated by the apparatus movement; Closed door apparatus racking. May 5, 2015 Slide 18

Safety Earthing switch With full making capacity short time withstand current for 3 seconds; Operated from the front; Provided with secure position indicators; Motor operated drive mechanism available. May 5, 2015 Slide 19

May 5, 2015 Slide 20

Safety Internal arc classified IAC AFLR according to the IEC 62271-200 Annex A UniGear is in full accordance to all the five criteria: 1. The doors of the switchboard must remain closed and no opening of the cover panels must occur; 2. Any part of the switchboard which may be hazardous for personnel must not be ejected; 3. No holes must appear in the external housing of the switchboard in any parts accessible to personnel; 4. The vertically and horizontally arranged fabric indicators placed outside the switchboard must not get burnt; 5. All the switchboard earthing connections must remain effective. Front, rear and sides arc resistance. May 5, 2015 Slide 21

Safety Arc proof Internal arc classified IAC AFLR according to the new IEC 62271-200 Annex A; Front, rear and sides arc resistance. May 5, 2015 Slide 22

Safety Wall standing solution Maintenance and service operations performed from the front; Front access to all the compartments (apparatus, busbars, cables); Comfortable front cables access. May 5, 2015 Slide 23

Safety ABB Month DD, 2015 Slide 24

Remote racking ABB Month DD, YYYY Slide 25

IR Temperature Monitoring Faulty connections due to loose screws or corrosion Increase of the contact resistance Conversion of the power to heat Damage of the switchgear Prevention by contactless temperature monitoring of the contact points with IR sensors Busbars / points of contact May 5, 2015 Slide 26

IR Temperature Monitoring Medium Voltage Switchgear May 5, 2015 Slide 27

IR Temperature Monitoring MV-cubicle Busbar / Cable conexion IR Power supply: Modbus / Profbus 24 VDC PLC Binary outputs Temperature probes Sensor IR temperature probes Temperature monitoring of up to 12 points without contacting any live parts Measurement of the ambient temperature in the cubicle with sensor May 5, 2015 Slide 28

IR Temperature Monitoring Fast detection of the presence of a hot spot in an early stage Increasing of plant safety No additional checks of the contact points necessary Decreasing of costs Passive type temperature sensors Retrofit in most existing MV-cubicles (e.g. in the cubicle s front door) May 5, 2015 Slide 29

Safety ABB Month DD, YYYY Slide 30

Gas exhaust duct Overpressure flaps May 5, 2015 Slide 31

Gas exhaust duct Without extra measures May 5, 2015 Slide 32

Gas exhaust duct Standard duct 3m B < 3.5m Compact duct 2.8m B < 3m May 5, 2015 Slide 33

Gas exhaust duct May 5, 2015 Slide 34

Gas exhaust duct Compact duct with top chimneys 2.8m B < 3m May 5, 2015 Slide 35

Arc Detection ITH ü 15 ms ITH + 60 ms CB REA ü 2,5 ms + 60 ms CB IED ü 12 ms IED + 60 ms CB UFES ü < 4 ms after detection of an internal arc fault May 5, 2015 Slide 36

Arc Protection - ITH Ith pressure switches ü Easy to use ü Fast and reliable ü Economic solution

Arc Protection - REA 3 Trip REA 101 REA 101 Trip 3 Trip 1 Trip 2 Light I> I> REA 103 REA 105 Trip 1 Trip 2 Example Sectionalizing of outgoing feeders REA 105 on the second outgoing level trips the feeder CB on detection of an arc The upstream REA 105 trips the sectionalizing CB after a preset delay if the arc has not been eliminated The two REA 101 units trip the incoming feeder CBs if the arc fault still persists May 5, 2015 Slide 38

Arc Protection - IED Relion 615 & 620 (optional) Per compartment (CB, Busbar, Cables) Economic solution May 5, 2015 Slide 39

Arc Protection - UFES + UFES + REA Versatile monitoring options with REA system: Optical detection via line or lens sensors Overcurrent detection Selective protection Circuit-breaker failure protection Ultra-fast arc extinction by UFES Certified interfaces Extremely short tripping times < 4 ms (after detection) Combinable arc protection UFES + REA May 5, 2015 Slide 40

Arc Protection - UFES

UniGear Digital Available product 5. Mai 2015 Slide 42

UniGear Digital Overview 61850 May 5, 2015 Slide 43

UniGear Digital Overview Current sensor Shielded cable with RJ45 Protection relay Adapter Voltage sensor May 5, 2015 Slide 44

UniGear Digital Overview Protection relay with IEC 61850 Current sensors Voltage sensors 1pcs 0.5kg 1pcs 2kg May 5, 2015 Slide 45

UniGear Digital Overview Keep project time schedule Comply with specifications and standards Keep cost targets Maximize integration Flexible to changes May 5, 2015 Slide 46