Achieving IEC Standard Compliance for Fiber Optic Connector Quality through Automation of the Systematic Proactive End Face Inspection Process

Similar documents
Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Why Expanded Beam types are essential in military and other harsh environment applications

Fiber Optic Terminus End Face Quality Standards

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Inspection and Cleaning Procedures for Fiber Optic Connections

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

How To Properly Maintain A Fiber Optic Infrastructure

99 Washington Street Melrose, MA Phone Toll Free Visit us at

DEFINING AND MEASURING PHYSICAL PARAMETERS OF PC POLISHED FIBER OPTIC CONNECTORS

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

Module Connectors and Cable Specifications

Optical Power Meter. Specification & User Manual

Insertion Losses of Fiber Optical Connectors

Loss & Continuity Testing with MPO/ MTP Connectors

Enabling 21 st Century Connectivity

Corning Cable Systems CAH Connections SM Gold Program Tested and Trusted Cable Assembly Houses for High-Quality Products

As today s evolving data centers

BLINK Triple-Play Connector

HoW confident are You about Your connector cleanliness?

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Managing Physical Security Risk in Physical Layer Infrastructure Solutions

Making Strategic Decisions About Optics and FC Cabling for System z Enterprises

Next level Network Solutions

Optical Interconnect Technology for High-bandwidth Data Connection in Next-generation Servers

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

FIBER OPTIC CONNECTOR CLEANERS 2014/2015

Secure/Keyed LC System Solutions Overview

HARTING Value Added Business

Expanded Beam & Physical Contact Fiber Optic Connectors

MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2

MINIMIZING PMD IN CABLED FIBERS. Critical for Current and Future Network Applications

The High Cost of a Low-Cost Cable Certification Tester

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM

Cat S O SSM. Services. Reporting Particle Count by ISO Code. Management Guide. Two methods of reading particles

MDU SC Connector Termination Procedure

Fiber Optic Cable Installation

NATUS SOLUTIONS Turnkey Project Management Project Engineering and Industrial Installations. Electrotechnical Solutions at the Highest Level

Understand, Maintain and Service Your Torque Wrench

Improving Chromatic Dispersion and PMD Measurement Accuracy

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

Surface Scanning Probes for Lighthouse Particle Counters Solair Gen D/E

Residential Solar Guide:

CISCO 10GBASE X2 MODULES

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

WHITE PAPER. Achieving Total Traffic Visibility in Enterprise and Carrier Grade Optical Networks

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

PURE : REliable planning of data center cabling

White Paper Volume Choosing an Order Fulfillment Service.

3D Deformation Measurement with Akrometrix TherMoiré and Digital Fringe Projection

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

Fiber Coupler Overview

The Executive Guide to Agile BPM. A Readiness Assessment

Suggested Guidelines For the Handling of

Reliable, Consistent, Quality

APPLICATION NOTE POLARIZATION MEASUREMENTS

4RU High Density Shelf Installation Instructions

TIER-1/TIER-2 FIBER CERTIFICATION KITS

Polymer Coated Fiber Cable (PCF)

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Plug - Type (Male/Female) Attenuators CAA series Singlemode

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

PROFINET Installation Guideline for Cabling and Assembly

CommScope Intelligent Building Infrastructure Solutions (IBIS)

Fibre optic testing best practices

MOOG. MACHINING SUPPLIER WORKMANSHIP STANDARDS Issue: 1-APRIL- 2007

MT-RJ Connectors Termination Procedure

Asbestos abatement Sampling & Analysis. Abatement Project Supervision

KPMG Lean Six Sigma The right place and the right time is here and now

Reasons for reissue are in Section 6, REVISION SUMMARY.

agility made possible

Termination Procedure. FCUPC One Piece Connector

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

GOVERNANCE AND MANAGEMENT OF CITY COMPUTER SOFTWARE NEEDS IMPROVEMENT. January 7, 2011

How Do I know If I Need RCx HOW TO CHOOSE A MANAGED SERVICES PROVIDER.

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Measuring of optical output and attenuation

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

TAGUCHI APPROACH TO DESIGN OPTIMIZATION FOR QUALITY AND COST: AN OVERVIEW. Resit Unal. Edwin B. Dean

How To Use The Visifault Visual Fault Locator

DIAMOND AVIM Connector

Billions of arithmetic operations per second what s their value without cabling?

Patch Cord Quality, Reliability and Performance. The Impact of Industry Specifications and Physical Parameters on Patch Cord Performance

10 Keys to Increasing Print Apply System Uptime

White paper. Reduce the Risks When Deploying Data Collection Technologies: Outsource Implemenation Services

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

All replacement hub units are not created equal. What you don t know can cost you time, money, and customers.

For MRI Scanners, Equipment, and MRI Body Coils

TOYOTA TECHNICAL. An example of a tire pressure monitor valve sub-assembly. This mounts to a drop area in the wheel.

Cisco CWDM GBIC and CWDM SFP Installation Note

Cable Assemblies. Features and Benefits

ADDENDUM USER MANUAL LBV300S-6, LBV300XL & LBV600XL

REDUCING THE COST OF TEST IN LASER DIODE MANUFACTURING. Lawrence A. Johnson President, CEO, and Founder ILX Lightwave

Tube Control Measurement, Sorting Modular System for Glass Tube

Transcription:

Achieving IEC Standard Compliance for Fiber Optic Connector Quality through Automation of the Systematic Proactive End Face Inspection Process Matt Brown Executive Summary It is widely known in the fiber optic industry that scratches, defects, and dirt on fiber optic connector end faces negatively impact network performance. As bandwidth requirements continue to grow and fiber penetrates further into the network, dirty and damaged optical connectors increasingly impact the network. If dirty and damaged end faces are not dealt with systematically, these defects can degrade network performance and eventually take down an entire link. In the effort to guarantee a common level of performance from the connector, the International Electrotechnical Commission (IEC) created Standard 61300-3-35, which specifies pass/fail requirements for end face quality inspection before connection. Designed to be a common reference of product quality, use of the IEC Standard supports product quality throughout the entire fiber optic life cycle, but only when compliance to the standard occurs at each stage. In response, current best practices recommend systematic proactive inspection of every fiber optic connector end face before connection. While current research shows that this practice is eliminating the installation of contaminated fibers and improving network performance, the uncontrollable variables of technician eyesight and expertise, ambient lighting, and display conditions keep manual inspection and analysis from being a 100-percent reliable and repeatable method of assuring IEC compliance. In addition, because manual inspection does not create a record of the inspection process, certification of quality at the point of installation is not practical. Because compliance to the IEC Standard is the only way to achieve the promise of today s fiber-rich, high-connectivity networks, this white paper proposes the automation of the inspection process through the addition of analysis software programmed to the Standard s pass/fail criteria to the practice of systematic proactive inspection. Automation of the systematic proactive inspection process using software programmed to the IEC Standard eliminates the variables associated with manual inspection, provides a documentable record of the quality of the connector end face at the point of installation, and provides a 100-percent repeatable and reliable process. Combined, these benefits make automated end face inspection the most effective method available to assure and certify compliance to the IEC Standard throughout the fiber optic product life cycle, and achieve the promise of next-generation networks. White Paper

IEC Standard 61300-3-35 IEC Standard 61300-3-35 is a global common set of requirements for fiber optic connector end face quality designed to guarantee insertion loss and return loss performance. The Standard contains pass/fail requirements for inspection and analysis of the end face of an optical connector, specifying separate criteria for different types of connections (for example, SM-PC, SM-UPC, SM-APC, MM, and multi-fiber connectors). For more detail on the Standard, copies of the copyrighted document are available for purchase at www.ansi.org by searching for 61300-3-35. These criteria are designed to guarantee a common level of performance in an increasingly difficult environment where fiber is penetrating deeper into the network and being handled by more technicians, many of whom may be unfamiliar with the criticality of fiber optical connector end face quality or possess the experience and technical knowledge required to properly assess it. The standard is designed to be used as a common quality reference between supplier and customer, and between work groups in several ways: y As a requirement from the customer to the supplier (for example, integrator to component supplier or operator to contractor) y As a guarantee of product quality and performance from the supplier to the customer (for example, manufacturer to customer, contractor to network owner, or between work groups within an organization) y As a guarantee of network quality and performance within an organization As more stages in the fiber optic product life cycle, shown in Figure 1, are outsourced to disparate vendors, the standard takes on renewed importance in ensuring the optimized performance of today s fiber-dense networks. Figure 1. Fiber Optic Product Life Cycle 2 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

The Development of the IEC Standard The quality values used in the IEC standard are the result of years of extensive testing of scratched, damaged, or dirty optical connectors conducted by a coalition of industry experts including component suppliers, contract manufacturers, network equipment vendors, test equipment vendors, and service providers. This work has been published previously in a number of papers as noted in the References section of this paper. Understanding the variables and limitations of manual visual inspection, fiber optic test and measurement manufacturer Viavi contributed its automated objective inspection and analysis software FiberChek2, as illustrated in Figure 2, to the IEC for use in the development of the 61300-3-35 visual inspection standard. Automating the pass/fail process using research-based parameters extracted from testing conducted by the aforementioned industry coalition provided the IEC with a repeatable standard of quality that would guarantee a common level of performance, creating a positive impact on both product and network performance. More than 8 years of testing on a constantly expanding database of fibers and fiber devices (for example, SM, MM, Ribbon, E2000, SFP/ XFP, Bend-insensitive fibers, Lenses, and other interfaces), combined with widespread use in the industry by component manufacturers, integrators/cms, OEMs, third-party installers, and service providers, makes the Viavi software program the only proven automated objective inspection software program that assures compliance to the IEC standard at every step of the fiber optic life cycle. Testament to this is the fact that this software program is currently used by three of the top five U.S. cable assembly manufacturers, along with six of the largest optical component manufacturers, five of the largest network equipment vendors, and five of the top Network Service Providers (NSPs) in the world, making Viavi FiberChek2 software the current worldwide industry standard for automated objective fiber optic connector end face inspection. Figure 2. Example of the Proven Inspection and Analysis Software Program FiberChek2 from Viavi The criteria in the IEC Standard requires the user to know the exact location and size of surface defects (for example, scratches, pits, and debris) on the fiber optic connector end face. As a result, it is only through the use of automated inspection and analysis software that compliance to the IEC Standard (or customer specification) can be tested and certified. The combination of common requirements (the IEC Standard) and automated inspection and analysis (FiberChek2) have measurably impacted product quality through the supply chain. This is providing improved repeatability and stability of inspection analysis throughout the fiber optic product life cycle, ensuring consistent product performance regardless of the number and expertise of vendors and technicians involved in the manufacture, installation, and network administration processes. 3 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

Proactive Inspection Model: Step One Toward Achieving IEC Compliance Despite its role in the development of the IEC Standard and usage by industry leaders, automated inspection and analysis software is not yet in widespread use across the fiber optic industry. In an effort to enable compliance to the Standard even when using manual visual inspection equipment alone, IEC and industry leaders are supporting the promotion of fiber handling best practices. An example of one such educational effort is the proactive inspection model developed and promoted by fiber optic test equipment manufacturer Viavi, Inspect Before You Connect (IBYC), as illustrated in Figure 3. Figure 3. Example of the Proactive Inspection Model: Inspect Before You Connect The simple four-step IBYC model, which supports and is mandated by the IEC Standard, effectively guides technicians of varying levels of expertise in the proper implementation of systematic proactive inspection. y Step 1 Inspect: Use the microscope to inspect the fiber. If the fiber is dirty, go to Step 2. If the fiber is clean, go to Step 4. y Step 2 Clean: If the fiber is dirty, use a cleaning tool to clean the fiber end face. y Step 3 Inspect: Use the microscope to re-inspect and confirm the fiber is clean. If the fiber is still dirty, go back to Step 2. If the fiber is clean, go to Step 4. y Step 4 Connect: If both the male and female connectors are clean, they are ready to connect. Consistent use of the IBYC model ensures that proactive inspection is performed correctly every time and that fiber optic end faces are clean prior to mating connectors, eliminating the installation of dirty or damaged fibers into the network and optimizing network performance. As a result, IBYC has been incorporated into manufacturing procedures for the majority of the world s leading organizations using fiber, increasing knowledge of this process and helping it become routine practice around the world. 4 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

Automated Inspection and Analysis: Achieving and Certifying IEC Compliance Even with the aid of the IBYC model, manual inspection using only a video microscope can be difficult depending on the technician s expertise and can result in variable connector quality and network performance. Reliant on technician eyesight and expertise along with variable display settings and ambient lighting, manual inspection and analysis is not 100 percent reliable, repeatable, or certifiable. Because it produces no visual record of the end face condition in the manual inspection process, certifying compliance at the point of installation through images or reporting is both unreliable and impractical, as Figure 4a shows. To ensure IEC compliance is achieved, automated inspection of fiber optic connector end faces using inspection and analysis software built on the IEC Standard s pass/fail criteria is the most effective method available. With it technicians of all skill levels can effectively accomplish both compliance and certification through images and reports, as Figure 4b shows. PASS Figure 4a. Manual Inspection requires technicians to judge whether the connector complies with the IEC Standard. Figure 4b. Automated Inspection gives technicians a pass or fail result. Using the software, automated inspection and analysis can produce a visual record of the end face condition as shown in Figure 5, which can be used in reports and archived for future reference.) As a result, automated inspection and analysis presents several clear advantages over subjective inspection: y Eliminates variation in results y Certifies and records product quality at time of inspection y Enables technicians of all skill levels to certify quality reliably and systematically y Makes advanced pass/fail criteria simple to use y Improves product and network performance and yields 5 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

Using a fiber optic inspection and analysis software program that is preloaded with the IEC Standard specifications, such as Viavi FiberChek2 software, any technician can effectively: y Inspect and certify compliance with IEC 61300-3-35 or other customer-specified standards at every stage of the fiber optic product life cycle at the push of a button y Implement simple pass/fail acceptance testing; no skill in quality judgment is necessary y Generate detailed analysis reports that can be archived Figure 5. Automated inspection enables the technician to certify compliance to the standard by producing a date stamped test report. 6 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

Conclusion: Business Impact of Automated End Face Analysis The combination of common requirements (the IEC Standard) and automated fiber optic inspection and analysis software (FiberChek2) has positively impacted product quality across the supply chain. The business impacts of reliable, repeatable automated fiber optic connector inspection and certification include: y Insured and repeatable product quality through the quantification of connector end face condition at installation y Assurance of customer satisfaction and supplier protection through the reliable documentation of connector end face quality y Competitive advantage for component and system vendors, and for installation contractors who can cost-effectively document end face quality y A common, repeatable system provides correlation through the supply chain y Easy deployment of custom requirements analysis Combined, these benefits make automated end face inspection the most effective method available to assure and certify compliance to the IEC Standard throughout the fiber optic product life cycle, and achieve the promise of next-generation networks. 7 Achieving IEC Standard Compliance for Fiber Optic Connector Quality

References 1. Qualification of Scattering from Fiber Surface Irregularities, Journal of Lightwave Technology, V.20, N 3, April 2002, pp. 634 637. 2. Optical Connector Contamination/Scratches and its Influence on Optical Signal Performance, Journal of SMTA, V. 16, Issue 3, 2003, pp. 40 49. 3. At the Core: How Scratches, Dust, and Fingerprints Affect Optical Signal Performance, Connector Specifier, January 2004, pp. 10 11. 4. Degradation of Optical Performance of Fiber Optics Connectors in a Manufacturing Environment, Proceedings of APEX2004, Anaheim, California, February 19 Feb 26, 2004, pp. PS-08-1-PS-08-4. 5. Cleaning Standard for Fiber Optics Connectors Promises to Save Time and Money, Photonics Spectra, June 2004, pp. 66 68. 6. Analysis on the effects of fiber end face scratches on return loss performance of optical fiber connectors, Journal of Lightwave Technology, V.22, N 12, December 2004, pp. 2749 2754. 7. Development of Cleanliness Specification for Single-Mode Connectors, Proceedings of APEX2005, Anaheim, California, February 21 26, 2005, pp. S04-3-1, 16. 8. Keeping it clean: A cleanliness specification for single-mode connectors, Connector Specifier, August 2005, pp. 8 10. 9. Contamination Influence on Receptacle Type Optical Data Links, Photonics North, 2005, Toronto, Canada, September 2005. 10. Development of Cleanliness Specifications for 2.5 mm and 1.25 mm ferrules Single-Mode Connectors, Proceedings of OFC/NFOEC, Anaheim, California, March 5 10, 2006. 11. Standardizing cleanliness for fiber optic connectors cuts costs, improves quality, Global SMT & Packaging, June/July 2006, pp. 10 12. 12. Accumulation of Particles Near the Core during Repetitive Fiber Connector Matings and De-matings, Proceedings of OFC/NFOEC2007, Anaheim, CA, March 25 29, 2007, NThA6, pp.1 11. 13. Development of Cleanliness Specifications for Single-Mode, Angled Physical Contact MT Connectors, Proceeding of OFC/NFOEC2008, San Diego, February 24 28, 2008, NThC1, pp. 1 10. 14. Correlation Study between Contamination and Signal Degradation in Single-Mode APC Connectors, Proc. SPIE, Vol. 7386, 73861W (2009); doi:10.1117/12.837545. Contact Us +1 844 GO VIAVI (+1 844 468 4284) To reach the Viavi office nearest you, visit viavisolutions.com/contacts. 2016 Viavi Solutions Inc. Product specifications and descriptions in this document are subject to change without notice. iecinspect-wp-fit-tm-ae 30168245 900 1010 viavisolutions.com