Spiral Duct Specifications

Similar documents
FINAL December 2012 SECTION DUCTWORK

The EDGE Self-Sealing Round Duct System

Uni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA

Duct Fabrication Specifications. Duct Construction SUBURBAN SHEET METAL LTD. Page 1 of 43. Mailing Address P.O. Box 739 Kennedale, TX 76060

Welcome. Green HVAC Ductwork Done Right! John Reints, PE Eugene Smithart, PE

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

EFFICIENT DUCT SYSTEM DESIGN

Lindab Representative s Handbook

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

Flanged and Butt-= Weld Type

FIRE DAMPER APPLICATION GUIDE

AMPSEAL* Automotive Plug Connector and Header Assembly

SECTION HVAC AIR DISTRIBUTION

HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Air-side Systems: Air Duct Design

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

GENERAL RUBBER LINING PRINCIPLES

James M. Pleasants Company

UNITED STATES CUTTING TOOL INSTITUTE Product Groupings for Standards Activities CUTTING TOOL PRODUCTS

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

HYDRAULIC PIPING STANDARD HANDBOOK. Revision 1

Section SEWER PIPE INSTALLATION AND TESTING

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

SECTION STORM DRAINAGE SYSTEM

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Section 2100-Trenching and Tunneling

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

Copper Meter Resetters

Heating, Ventilation & Air Conditioning

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

ME 111: Engineering Drawing

Sheet Metal Products for the HVAC Industry

GrEAT PACIFIC ELBOW COMPANY PRODUC T C ATALOG

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Fabricated Drainage Products

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Haviland Drainage Products Co. Box 97 Haviland, Ohio Ph. (419) Fax (419)

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

GEET Fuel Processor Plans

SECTION UNDERGROUND ELECTRIC SERVICE

GK Packing System Welding Instructions

IEC ALUMINUM EXTRUSIONS IEC. International Extrusion Corporation ALUMINUM EXTRUSION FABRICATION ANODIZING VERTICAL & HORIZONTAL WET PAINT LINE

Design Calculation or Analysis Cover Sheet. Complete only applicable items M8C-VCTO B

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

DIVISION 4300 STORM DRAINAGE

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

TARIFF CODE and updates standard

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

security products metric sizes Redefine your comfort zone.

Rubber Lining Application Manual Revision Date: September 1, Section 10: Pipe Lining Procedures Page: 10-1

MIQ TM Mineral Insulated Heating Cable INSTALLATION PROCEDURES. (North America)

INDEX. Sec. No. Items Page Nos.

pvc well casing & drop pipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Caps STANDARD WEIGHT Inches / Pounds

Suggested Specifications: Steel Pipe for Water Transmission

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

ABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

POWERS Controls No. 4 Pneumatic Damper Actuator

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Pipe Thread Types and Designations

Pipeline Replacement using Relining

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013

Fire Barrier Duct Wrap 15A

RING JOINT SYSTEMS 207

COMPACT DATA FAST AND SIMPLE DATA CABLE TRUNKING. Building Solutions Automotive Industry

Partitioning & Ceiling Product Information

Transcription:

Duct Specifications 9707 Williams Road Thonotosassa, FL 33592 Fax (813) 413-8377 Tel (813) 413-8230 Toll free (877) CDS DUCT 237-3828

SINGLE WALL All round spiral duct and fittings shall be manufactured from G-90 galvanized steel, conforming to ASTM and SMACNA standards. Standard elbows will have 1.5 centerline radius. Other radii and vaned elbows are available as needed. Elbows through 12 shall be die formed, with stitch welded joints. Elbows 14 through 30 shall be gore-locked construction. All elbows above 32 shall also be gored, but with tack weld and sealed construction for use to 4 w.g., or solid welded for use to 10 w.g. Branch connections in medium pressure systems shall be conical for 90 degree taps, and straight for 45 degrees. Seams and tap connections shall be tack welded and sealed with mastic for use up to 4 w.g., or solid welded for use to 10 w.g. Standard connections are slip fit with couplings. Gasketed (up to 36 ), flanged, or mate (by Ductmate Industries) connections are also available. DUAL WALL Double wall insulated spiral is available with solid or perforated liners; Mylar barrier is available as a barrier between perforated liner and insulation. 1, 2 and 3 insulation thicknesses are available; k value is 0.27.

SINGLE WALL ROUND Nominal Diameter Maximum 2" w.g. Maximum 4" w.g. Maximum 10" w.g. Positive Static Pressure Positive Static Pressure Positive Static Pressure Std. Std. Std. 4 26 24 1.02 20' 26 24 1.02 20' 26 24 1.02 20' 6 26 24 1.59 20' 26 24 1.59 20' 26 24 1.59 20' 8 26 24 2.15 20' 26 24 2.15 20' 26 24 2.15 20' 10 26 24 2.7 20' 26 24 2.7 20' 26 24 2.7 20' 12 26 24 3.25 20' 26 24 3.25 20' 26 24 3.25 20' 14 26 24 3.8 20' 26 24 3.8 20' 26 24 3.8 20' 16 26 24 4.35 20' 26 24 4.35 20' 24 22 5.55 20' 18 26 24 4.9 10' 24 24 6.25 20' 24 22 6.25 20' 20 26 24 5.44 10' 24 22 6.95 20' 24 22 6.95 20' 22 26 24 5.99 10' 24 22 7.64 20' 24 22 7.64 20' 24 26 24 6.54 10' 24 22 8.34 10' 24 22 8.34 10' 26 26 24 7.08 10' 24 22 9.04 10' 24 22 9.04 10' 28 24 22 9.74 10' 22 20 11.84 10' 22 20 11.84 10' 30 24 22 10.43 10' 22 20 12.69 10' 22 20 12.69 10' 32 24 22 11.13 10' 22 20 13.54 10' 22 20 13.54 10' 34 24 22 11.83 10' 22 20 14.39 10' 22 20 14.39 10' 36 24 22 12.53 10' 22 20 15.24 10' 22 20 15.24 10' 38 22 20 16.08 10' 20 20 18.94 10' 20 20 18.94 10' 40 22 20 16.93 10' 20 20 19.94 10' 20 20 19.94 10' 42 22 20 17.78 10' 20 20 20.94 10' 20 20 20.94 10' All gauges and weights are for galvanized steel. Some gauges are not available for alternate materials. Leakage for 2" w.g. product will not exceed SMACNA Leakage class 6 when joints are adequately sealed. Leakage for 4" & 10" w.g. product will not exceed SMACNA Leakage class 3 when joints are adequately sealed.

SINGLE WALL ROUND Nominal Diameter Maximum -2" w.g. Maximum -4" w.g. Maximum -10" w.g. Negative Static Pressure Negative Static Pressure Negative Static Pressure Std. Std. Std. 4 26 24 1.02 20' 26 24 1.02 20' 26 24 1.02 20' 6 26 24 1.59 20' 26 24 1.59 20' 26 24 1.59 20' 8 26 24 2.15 20' 26 24 2.15 20' 26 24 2.15 20' 10 26 24 2.7 20' 26 24 2.7 20' 26 22 2.7 20' 12 26 24 3.25 20' 26 24 3.25 20' 24 22 4.15 20' 14 26 24 3.8 20' 24 22 4.85 20' 24 20 4.85 20' 16 26 24 4.35 20' 24 22 5.55 20' 22 18 6.75 20' 18 24 22 6.25 10' 24 20 6.25 20' 22 18 7.6 20' 20 24 22 6.95 10' 22 20 8.45 20' 22 18 8.45 20' 22 24 20 7.64 10' 22 18 9.3 20' 22 16 9.3 20' 24 22 20 10.15 10' 22 18 10.15 10' 20 16 11.95 10' 26 22 20 10.99 10' 20 18 12.95 10' 20 18** 12.95 10' 28 22 18 11.84 10' 20 16 13.95 10' 18 16** 18.16 10' 30 22 18 12.69 10' 20 16 14.95 10' 18 16** 19.46 10' ** Reinforce with 2x2x3/16 angle 12' on center All gauges and weights are for galvanized steel. Some gauges are not available for alternate materials.

DOUBLE WALL ROUND Nominal Diameter (I.D) OD/ID Maximum 2" w.g. Maximum 4" w.g. Maximum 10" w.g. Positive Static Pressure Positive Static Pressure Positive Static Pressure OD/ID Std. OD/ID OD/ID Std. OD/ID OD/ID Std. 4 26/26 24/24 2.51 20' 26/26 24/24 2.51 20' 26/26 24/24 2.51 20' 6 26/26 24/24 3.62 20' 26/26 24/24 3.62 20' 26/26 24/24 3.62 20' 8 26/26 24/24 4.63 20' 26/26 24/24 4.63 20' 26/26 24/24 4.63 20' 10 26/26 24/24 5.71 20' 26/26 24/24 5.71 20' 26/26 24/24 5.71 20' 12 26/26 24/24 6.71 20' 26/26 24/24 6.71 20' 26/26 24/24 6.71 20' 14 26/26 24/24 7.8 20' 26/26 24/24 7.8 20' 24/26 22/24 9 20' 16 26/26 24/24 8.79 10' 24/26 24/24 10.15 20' 24/26 22/24 10.15 20' 18 26/26 24/24 9.88 10' 24/26 22/24 11.38 20' 24/26 22/24 11.38 20' 20 26/26 24/24 10.87 10' 24/26 22/24 12.52 20' 24/26 22/24 12.52 20' 22 26/26 24/24 11.95 10' 24/26 22/24 13.75 10' 24/26 22/24 13.75 10' 24 26/26 24/24 12.95 10' 24/26 22/24 14.9 10' 24/26 22/24 14.9 10' 26 24/26 22/24 16.13 10' 22/26 20/24 18.24 10' 22/26 20/24 18.24 10' 28 24/26 22/24 17.28 10' 22/26 20/24 19.53 10' 22/26 20/24 19.53 10' 30 24/26 22/24 18.5 10' 22/26 20/24 20.91 10' 22/26 20/24 20.91 10' 32 24/26 22/24 19.65 10' 22/26 20/24 22.21 10' 22/26 20/24 22.21 10' 34 24/26 22/24 20.88 10' 22/26 20/24 23.59 10' 22/26 20/24 23.59 10' 36 22/26 20/22 24.88 10' 20/26 20/22 27.74 10' 20/26 20/22 27.74 10' 38 22/26 20/22 26.26 10' 20/26 20/22 29.27 10' 20/26 20/22 29.27 10' 40 22/26 20/22 27.64 10' 20/26 20/22 30.8 10' 20/26 20/22 30.8 10' 42 22/26 20/22 28.94 10' 22/26 20/22 32.25 10' 20/26 20/22 32.25 10' All gauges and weights are based on 1" dual wall with perforated liners. Leakage for 2" w.g. product will not exceed SMACNA Leakage class 6 when joints are adequately sealed. Leakage for 4" & 10" w.g. product will not exceed SMACNA Leakage class 3 when joints are adequately sealed.

DOUBLE WALL ROUND Nominal Diameter Maximum -2" w.g. Maximum -4" w.g. Maximum -10" w.g. Negative Static Pressure Negative Static Pressure Negative Static Pressure Std. Std. Std. 4 26/26 24/24 2.51 20' 26/26 24/24 2.51 20' 26/26 24/24 2.51 20' 6 26/26 24/24 3.62 20' 26/26 24/24 3.62 20' 26/26 24/24 3.62 20' 8 26/26 24/24 4.63 20' 26/26 24/24 4.63 20' 26/26 22/24 4.63 20' 10 26/26 24/24 5.71 20' 26/26 24/24 5.71 20' 24/26 22/24 6.61 20' 12 26/26 24/24 6.71 20' 24/26 22/24 7.76 20' 24/26 20/24 7.76 20' 14 26/26 24/24 7.8 20' 24/26 22/24 9 20' 22/26 18/22 10.2 20' 16 24/26 22/24 10.15 20' 24/26 20/24 10.15 20' 22/26 18/22 11.5 20' 18 24/26 22/24 11.38 10' 22/26 20/24 12.88 20' 22/26 18/22 12.88 20' 20 24/26 20/24 12.52 10' 22/26 18/24 14.18 20' 22/26 16/22 14.18 20' 22 22/26 20/24 15.56 10' 22/26 18/24 15.56 10' 20/26 16/22 17.36 10' 24 22/26 20/24 16.86 10' 20/26 18/24 18.81 10' 20/26 18/22** 18.81 10' 26 22/26 18/24 18.24 10' 20/26 16/24 20.34 10' 18/26 16/22** 24.55 10' 28 22/26 18/24 19.53 10' 20/26 16/24 21.79 10' 18/26 16/22** 26.3 10' 30 20/26 18/24 23.32 10' 20/26 16/24 23.32 10' 18/26 16/22** 28.13 10' ** Reinforce with 2x2x3/16 angle 4' on center All gauges and weights are for galvanized steel. Some gauges are not available for alternate materials.

NEED SPIRAL OR OVAL IN A HURRY? Let us help! Now Shipping Stock 90 & 45 Elbows Tees, Crosses, & Taps Plugs & Endcaps Reducers Bellmouths NOW FABRICATING SPIRAL & OVAL : PIPE & FITTINGS SINGLE & DOUBLE WALL Standard sizes range from 4 Φ to 24 Φ Couplings CALL FOR COMPETITIVE PRICES! Other fittings and sizes available. Please contact our office for pricing. Commercial Duct Systems Tel: (813) 413-8230 Toll Free: (877) 237-3828 Fax: (813) 413-8377 9707 Williams Rd. Thonotosassa, FL 33592 GASKETTED CONNECTORS

COMMERCIAL DUCT SYSTEMS NOW MANUFACTURING FLAT OVAL Now Manufacturing Flat OVAL s & : -Labeled and piece-marked for easy installation. -Every piece meets SMACNA standards -Available as Single Wall, Double Wall, Perforated, Paintgrip, Gasket, Continuous Weld Seams, and more custom options. Our LOW PRICES will make a competitive difference on your next job. 9707 Williams Rd Thonotosassa, FL 33592 Call us today and place your Order: Phone: 877-237-3828 Fax: 813-413-8377 E-mail: CDSLLC@commercialduct.com

WHEN QUALITY, SERVICE, AND DETAILS REALLY MATTER. Q U A L I T Y, P R E C I S I O N - ON TIME". CDS OFFERS THE BEST PRICING AND THE HIGHEST QUALITY. -Rectangular,, and Oval Duct -LEEDS approved Duct -Everything SMACNA approved -Many orders available within 48 hours -All pieces labeled and tagged for convenient, coordinated, hassle free installation. -Delivery or Pickup LET US PROVIDE THE EDGE YOU NEED IN TODAY'S MARKET, FAST TURNAROUND WITH QUALITY YOUR FIELD CREWS WILL APPRECIATE. contact us: (877) 237-3828 or CDSLLC@COMMERCIALDUCT.COM