PART NO. COMBUSTION AIR CAP

Similar documents
Explosion-Proof Electric Unit Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Commercial Gas Cooking Thermostats

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

NAVIEN AMERICA INC FITCH AVENUE

Cooling Capacity CFM in. w.c. (125 Pa)

HL Series - Commercial Heaters Tankless Water Heating Solutions

Commercial Gas Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

High efficiency, cast-iron gas boiler

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Powers Controls TH 192 S Single Temperature Room Thermostat

Commercial Portable Air Conditioners

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Commercial Gas Water Heaters

"EC" Series Electric Humidifier

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Electronic Flow Switches

F9MXE. Product Specifications

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

Industrial Generator Set Accessories

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

In-Line Electronic Flow Switches

Cooling Capacity CFM in. w.c. (125 Pa)

Industrial Generator Set Accessories

Commercial Electric Water Heater

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

2010 Residential Water Heater Replacement Check List

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

PIEZOMETER AIRFLOW MEASURING RING

ASX7-4-IOM-7 J

Commercial Gas Furnace Upflow

Cooling Capacity CFM in. w.c. (125 Pa)

AIR LINE VALVES AND GAUGES

Sanitary Type Electronic Flow Switches

Light Duty Commercial Electric Water Heater

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

REGULATORS 175/153 Series

Industrial Generator Set Accessories

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

EFFECTIVE NOVEMBER 2007

Arapahoe County Residential Water Heater Installation and Inspection Guide

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

ASME Packaged Indirect Fired Water Heater

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

NFPA31FuelOilPiping 1 Revised

Pressure Switch for gas and air

Spare Parts List M96A.24SM/B M96A.28SM/B

G9MXE. Product Specifications

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

4 Posiflow Proportional Solenoid Valves

Commercial Gas Water Heater

Industrial Generator Set Accessories

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

B-Series Temperature Switches

In-Line Electronic Flow Switches

Electronic, Digital and Mechanical Vibration Switches

NSN

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

EFFECTIVE OCTOBER Atwood Furnaces. and Digital Thermostats

Industrial Generator Set Accessories

G234X-55 Conventional Gas Boiler

SECTION AIR CONDITIONING UNIT

Data sheet Thermostatic sensors type RA 2000

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Electronic faucets for every occasion, every application

SIOUX HYBRID WATER HEATER

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

3500/93 System Display

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Commercial Semi-Instantaneous Water Heaters

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat


Installation Manual CLIFC Fan & Coil Variable Speed

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Centro-Matic Automatic Lubrication Systems System Controls

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

catalog Single Package Vertical Air Conditioners and Heat Pumps

SECTION HEAT PUMPS

RM7000 TC with Internal Pulser

RECON WATER HEATER INSTALLATION FORM

Transcription:

ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction Heavy-gauge aluminum construction Riveted at all major stress points for durability and service Fits type B flue pipe. Can be used for sidewall venting as well as thru the roof venting C FITS DIMENSIONS A B C 30297040 4 8-1/2 8-1/4 4 1-1/2 lbs. 30297060 6 10-1/2 9-1/4 6 4 lbs. 30297080 8 12-1/2 12-3/4 8 6 lbs. COMBUSTION AIR CAP Heavy gauge aluminum construction Eliminates downward draft Fits type B or single wall flue pipe Fresh air (combustion air) duct termination. A MODEL DIMENSIONS A B C 41000020 3050 6-3/4 4-1/4 4 1.5 lbs. C B.023.017 41000000 5070 9-1/2 5 6 3 lbs. 41000010 7090 12 7 8 5 lbs. EXHAUST HOOD Used for indirect vented applications Directs the heat away from the draft inducer Includes bird screen Heavy gauge aluminized steel construction. 7½ 6 3¾ MODEL NO. 3½ CB, LTS/U, and ETS/U 42924000 5 lbs. 4 (Side View) (Front View) RSTP15 and RSTP17 * 42406000 7 lbs. * Dimensions not shown 1

LINE REGULATORS Up To 2 psig Durable, corrosion-resistant construction Equipped with 12A09 Vent Limiting Device In the event of diaphragm rupture, gas escapement is limited to a non-hazardous level Must be installed on a horizontal plane. USE MODEL FOR HEATERS UP TO 140,000 BTU/HR FOR HEATERS 150,000 TO 220,000 BTU/HR FOR HEATERS 225,000 BTU/HR AND ABOVE CONNECTIONS MAXIMUM INLET OUTLET 325-3L 03307260 1/2 x 1/2 2 psig 7 W.C. 2 lbs. 325-5L 03307310 1/2 x 1/2 2 psig 7 W.C. 2 lbs. 325-5L 03307270 3/4 x 3/4 2 psig 7 W.C. 2 lbs. LINE REGULATORS Above 2 psig Heavy-duty construction High Capacity Internal Relief Inlet and Outlet Pressure Taps for easy system checks Must be vented to the outside. MODEL CONNECTIONS MAXIMUM INLET OUTLET 03483070 R622-BCF 1/2 x 1/2 10 psig 11 W.C. 3 lbs. FLEXIBLE CONNECTOR CSA Listed stainless steel gas connector. Included with all Tube Heaters. USE LENGTH I.D. FOR HEATERS UP TO 225,000 BTU/HR FOR HEATERS 225,000 BTU/HR AND ABOVE 30302360 36 1/2 1 lb. 30302361 36 3/4 2 lbs. RT SERIES Line Voltage Thermostat Part #30348970 Temperature range 50ºF to 90ºF with ± 4ºF differential 22 amp full load Capable of controlling up to 7 Space-Ray infrared tube heaters Economically priced Durable, bi-metallic heat sensing element Simple connections with easy-to-reach wiring terminals Easy to mount, fits flat on wall with one-inch recess in wiring box. 2

HEAVY DUTY Line Voltage Thermostat Part #03209000 Temperature range 35ºF to 95ºF with ± 2ºF differential 16 amp full load Sealed, dust protected SPDT switch Liquid-filled sensing element, specially treated against corrosion and firmly attached to top of thermostat, provides uniform control at ambient temperatures Dependable single-pole, double-throw snap acting contacts in steel, dust-tight, NEMA 1 enclosure Close differential for critical requirements Adjustable cutout stop. GENERAL DUTY /HIGH HUMIDITY ENVIRONMENT Line Voltage Thermostat Part #30525010 Temperature range 40ºF to 104ºF with ± 2.5ºF differential 16 amp full load Recommended for general duty and high humidity environments such as car washes, agricultural buildings, and water treatment plants Quality constructed thermostat designed for use in harsh environments Watertight ABS plastic meets NEMA 4x and NEC Article 547-4 requirements Responsive, durable, 316 stainless steel, sidemounted sensing coil Adjustable dial allows thermostat to be recalibrated Single SPDT switch. 24 VOLT THERMOSTAT Part #30562000 Temperature Range 50ºF to 90ºF with ± 4ºF differential Adjustable Heat Anticipator 24 volts 0.1 to 1.0 Amps Individual Heater Operation Requires Relay Kit Hermetically sealed Reed Switch operated by a magnet attached to coiled bimetal Snap-action operation makes precise leveling of the thermostat unnecessary Universal mounting vertical and horizontal faceplates included Use with 24-Volt Thermostat Relay Kit (Part #43274000 for LTU40-75 & CB20-50 or Part #43274010 for LTU80-250, LTS40-250 & ETS/U40-250) to control one Space-Ray infrared tube heater. PTS/U Series can be externally connected with a single 24V Thermostat and do not require a 24-Volt Thermostat Relay Kit 3

SETBACK 3000 THERMOSTAT Part #43240030 Digital Programmable 24-Volt thermostat N5 or L5 Control Capable of controlling up to 5 Space-Ray infrared tube heaters Fan center relay shipped separately Temperature Range 45ºF and 90ºF with ±1ºF differential 4 different program periods per day w/ 7 day programming Temporary Temperature override Battery Back-up Supplied with Heavy Duty Self-contained Locked Cabinet & Enclosure SETBACK 5000 THERMOSTAT Part #43240050 Digital Programmable Line Voltage thermostat N5 or L5 Control Temperature Range 45ºF and 90ºF with ±1ºF differential 4 different program periods per day with 5/2 day programming Temporary Temperature override Battery Back-up Supplied with Heavy Duty Self-contained Locked Cabinet & Enclosure. TWO STAGE DIGITAL SETBACK THERMOSTAT Part #30644100 For modulating two stage heaters- N7 or L7 Control 24V Digital Night Setback Thermostat with Large hybrid dot matrix display Temperature Range 40ºF and 90ºF with ±1ºF differential 7 day programming & 4 periods per day with Night Setback function ENERGY STAR Compliant Temporary override, Hold & Vacation hold Optional smart recovery Advanced copy function for fast easy programming Temperature offset (user calibration) Programmable length minimum run time Multi-stage adjustable temperature differential/cycle rate ± 2.25ºF differential Dual power capable (system/battery) Daylight savings button Multimode keyboard lockout with user programmable 3 Digit Code TWO STAGE ECONOMY THERMOSTAT - Part #30348100 For modulating two stage heaters- N7 or L7 Control Temperature Range 50ºF and 90ºF with ± 4ºF differential 24V Mechanical Thermostat Bi-Metallic heat sensing element Easy to mount, fits flat with one-inch recess in wiring box Non adjustable differential Economically priced. To be used when a mechanical thermostat is specified 4

24V Thermostat Relay Kit To control one Space-Ray infrared tube heater with a 24V Thermostat. 43274000 for LTU40-75 & CB20-50 43274010 for LTU80-250, LTS40-250 & ETS/U40-250 PTS/U Series can be externally connected with a single 24V Thermostat and do not require a 24V thermostat Relay Kit Two Stage Thermostat Relay Kit Part# 44195000 Required when controlling multiple Two Stage heaters (N7 / L7 Controls) with a single 24V Two Stage Thermostat. One relay kit per heater required. Supplied with ABS Enclosure and mounted externally. Thermostat Enclosure Part# 43244010 Heavy Duty metal thermostat enclosure - tamperproof Hinged access door with locking cover Can be used with any thermostat Prevents direct radiant energy affecting the thermostat sensor. Enclosure dimensions 9 ½ X 5 ½ 4 CHAIN KITS 41690250 Chain Kit 25 ft. chain with 12 S-hooks 41690350 Chain Kit 35 ft. chain with 12 S-hooks (50' straight heaters) 41690500 Chain Kit 50 ft. chain with 12 S-hooks (80' straight heaters) 41690120 Chain Kit for CB Series, 12 ft. chain with 8 S-hooks MANUAL CUTOFF VALVES 30285000 CSA listed ball valve, ½" NPT 30285020 CSA listed ball valve, ¾" NPT, for heaters 225,000 Btu/hr and above SPACE-RAY P.O. Box 36485 Charlotte, NC 28236 Phone (704) 372-3485 Fax (704) 332-5843 Toll Free (800) 438-4936 www.spaceray.com info@spaceray.com 5