OWNER MANUAL INSTALLATION INSTRUCTIONS

Similar documents
Oil - kerosene burners

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

MODEL HS OIL BURNERS. Publication Date 8/01/01 Revision 12 Manual U.S. Patent No. 4,388,064

Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Boiler and Burner Cleaning and Servicing Specifications

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Your safety and the safety of others are very important.

BOWIE PUMPS OPERATION - MAINTENANCE

OTF Oil Fired Pool Heater

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INSTALLATION MANUAL MODEL RP-100

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS

M A N U A L

Cooktop Low-Profile Ventilation Hoods

Technical Guide 08/15/14

Thermo Top - Troubleshooting Tree

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

K6C Summit Multi Oil Warm Air Furnace SAVE THESE AND BURNER INSTRUCTIONS FOR REFERENCE


Before installation it is important to know what parts you have and what the capabilities of these parts are.

G670 Intermittent Pilot Ignition Controls

CARING FOR YOUR WATER HEATER

INSTALLATION MANUAL MODEL RP-150

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Factory owners must ensure the boiler is:

User's Instructions. Alpha HE CB25/33 and HE SY25

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER


Why use Tigerloop in fuel heating systems?

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

PC1130 Electric Air Compressor

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

PC1131 Electric Air Compressor

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

OPL BASIC. Dosing System for Professional Laundry machines. Contents

1998½-2007 Dodge Ram 5.9L Cummins

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

1 DESCRIPTION OF THE APPLIANCE

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

VOYAGER 570G. 744A Sprayer Control

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Diagnostics for Mobile Homes: HVAC

Model 1210C Battery Powered Pump Shown. Description

Installation Instructions

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Draining and filling cooling system

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Walbro 255lph Inline Fuel Pump Install Procedure


RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Operator: Save these instructions for future use!

Advantium 2 Plus Alarm

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Oil and Coolant Circulating Heating System. Model - OCSM

OIL-FIRED WATER HEATERS 72E 73E 190E 241E 361E 541E

Servicing manual. Gas wall hung boiler condensing 600 Series - 11S / 19S / 24S / 24C /2006 GB(EN) For trade use

LPM-06 CONVERSION KIT

Munchkin Heat Exchanger Maintenance

Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Installation & Maintenance Instructions

VS CONTROL PACK INSTALLATION INSTRUCTIONS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Trouble Shooting. Pump

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Serial ATA to Serial ATA

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

INSTALLATION AND SERVICE MANUAL

Installation Instructions for Water Methanol Stage 1

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Cooling system components, removing and installing

Diesel Fuel Systems. Injection Nozzles

Rexroth Hydraulic Pump A10VO Series User Manual

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Installation Instructions

CEILING CASSETTE FAN COIL UNIT

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

TS93 EMR T/PT/TDE. Surface applied door closer

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

WARNING CANADIAN D.O.C. WARNING

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Transcription:

RIELLO BURNER SYSTEM mectron 3M TYPE 215 OWNER MANUAL INSTALLATION INSTRUCTIONS We are delighted that you have chosen the Riello burner. It is modern. clean, efficient and like any quality product. must be professionally installed and maintained to run correctly and at peak performance. Should the burner lock-out on safety, a light will come on behind the re-set button (see figure 2). All you need to do is press the re-set button and the burner will restart. Should the burner lock-out again, call your Authorized RIELLO Dealer for assistance. There are no customer serviceable parts inside the red cover. You should have the installer fully explain to you the operation of your new RIELLO burner as well as your total heating system. Your RIELLO burner should be serviced once a year by your Authorized RIELLO Dealer to insure many years of trouble free operation. CAUTION All burners should be installed by trained and licensed service technicians. SPECIFICA TIONS Firing Rate: 0.50 to 0.95 GPH (1. 6 to 3 kg/h 70.000 to 133,000 BTU/h 17.640 to 33.520 kcal/h) Fuel: No.2 Fuel oil Power 120 VOlts/60 Hz. Single Phase Requirements: 155 Watts (Maximum) DIMENSIONS [in.] (mm) FIGURE 1 Compliments of Aspen Gas & Oil Services Ltd Page 1 of 12 1-250-489-3780 1 866 802 3614

FIGURE 2 1. Flange 6. Turbulator Adjustment Screw 2. Fuel Line Return Port 7. Pressure Gauge Fixing Point 3. Fuel Line Inlet Port 8. Lock-out Indicator light and Re-set Button 4. Pump Pressure Regulator 9. Air Shutter 5. Vacuum Gauge Fixing Point ASSEMBLY OF BLAST TUBE TO BURNER CHASSIS (see figures 3 & 4) The blast tube and drawer assembly are shipped in a carton separate from the burner chassis. Choose the proper blast tube length for the installation. A)Remove the blast tube and burner chassis from their respective cartons. B) Remove the drawer assembly, 1, from inside the blast tube by undoing the screw, 2. Carefully pull the drawer assembly out of the blast tube and set aside. C)Remove the two bolts,3,from the front plate,4,of the burner chassis. Align the two holes on the blast tube holding plate,5, with the two holes left open where the bolts, 3, were removed. Replace the bolts and tighten firmly. Compliments of Aspen Gas & Oil Services Ltd Page 2 of 12 1-250-489-3780 1 866 802 3614

MOUNTING THE BURNER TO THE BOILER/FURNACE UNIT. (see Figure 5) The burner is mounted on to the burner/furnace unit by means of the two semi flanges supplied in the burner chassis carton. Optional universal flange and/or pedestal mount are available. A) Using the semi-flange assembly, 1, as a template, align the assembly so that it is centered on the burner access hole, 2, of the boiler/furnace unit. Mark the center of the two holes, 3. Be sure they are facing up. Drill 1/4" (6. 5mm) ho1es, through the front plate; install and secure at, 4, the two bolts with the special nuts (supplied). B) Secure the 2 halves of the mounting flange, l, to the blast tube using the two bolts, 5. Be sure that the flange is properly positioned so that the end cone is at least 1/4" (6.5 mm) back from the inside wall of the refractory of the combustion chamber. (see figure 6) C) Insert the blast tube into the boiler/furnace unit making sure the studs, 4, line up with the holes, 3, in the flange. Secure the burner using the two bolts 6 (supplied). D) The optional universal mounting flange could be used in place of steps A and B. MAKING THE BURNER CONNECTIONS WARNING When the combustion chamber is lined with a refractory material, it is imperative that the end cone not protrude into the chamber area as excessive heat at burner shut-down will cause damage to the end cone. Compliments of Aspen Gas & Oil Services Ltd Page 3 of 12 1-250-489-3780 866 802 3641

A) Remove the burner cover by loosening the three fixing screws, 7. (see figure 5) B) Wire as shown in figure 7 (A or B). All wiring must be done in accordance with existing electrical codes, both national and local. Compliments of Aspen Gas & Oil Services Ltd Page 4 of 12 1-250-489-3780 866 802 3641

1) Wire access hole 2) Hot Conductor (Black Wire) Terminal 3) Common Conductor (White Wire) Terminal 4) Ground Conductor (Green Wire) Terminal 5) Strain Relief WARNING The hot (Black) wire must be connected to the P terminal and the common (White) wire must be connected to the N terminal or damage will occur to the primary safety control. Compliments of Aspen Gas & Oil Services Ltd Page 5 of 12 1-250-489-3780 866 802 3641

OIL LINE CONNECTIONS (see figure 10) The burner is shipped with the pump set up for a two pipe system; 2 pipe connectors, 3, are supplied with the burner for connection to either a single or two pipe system. Pump is factory preset at 146 PSI (10 bar). 1a) LIFT (2 pipe) SYSTEM - The burner is shipped for installation in a two pipe system. See Table A for pipe lengths. Be sure that there are no air leaks or blockages in the piping system. DO NOT USE COMPRESSION FITTINGS. Suction and return lines should be the same size and both should extend to the same depth inside the fuel tank. Do not exceed the runs as shown in Table A. 1b) Attach the two pipe connectors to the pump suction and return ports, 9 & 10. Attach the required piping to these two pipe connectors. 2a) GRAVITY FEED SYSTEM - Convert the pump to a single line, gravity feed system by removing the BY -PASS plug, (see page 6). 2b) Connect one of the pipe connectors to the suction port, 10, of the pump. Attach the required piping to this pipe connectors. Be sure that the plug in the return port is tightened securely. NOTE: A pressure gauge can be attached to pressure port, 5, for eventual pressure readings. Compliments of Aspen Gas & Oil Services Ltd Page 6 of 12 1-250-489-3780 866 802 3641

Removal of BY PASS plug (see figure 10) 1) Remove the pump cover by undoing the four retaining screws, 6. 2) Remove the pump strainer, unscrew and remove the BY -PASS plug, 1, from port A. 3)Replace the strainer and pump cover. Tighten the 4 screws, 6, securely. NOTE: Be sure that the a-ring is properly seated prior to tightening the pump cover screws. WARNING Burner is shipped from the factory set up for a two pipe system. Figure 11 WARNING The height "p" should not exceed 13 feet (4 m) Warning The vacuum must not exceed 11.44 Hg. (11. 44 inches of Mercury). IMPORTANT An external appropriately listed/ certified filter must be placed in the fuel line between the fuel tank and the burner pump. Compliments of Aspen Gas & Oil Services Ltd Page 7 of 12 1-250-489-3780 866 802 3641

NOZZLE PLACEMENT (See figure 12) A) Determine the proper firing rate for the boiler/furnace unit, then use Table B, page 9, to select proper nozzle size for the burner. B) Remove the nozzle adapter, 2, from the drawer assembly by loosening screw, 1. C) Insert the proper nozzle into the nozzle adapter, tighten securely. D) Replace adapter, with nozzle installed, into drawer assembly and secure with screw,1 FIGURE 12 INSERTION OF DRAWER ASSEMBLY (see figure 13) A) Loosen the screw 3, then unplug the control box. 4. by pulling it up and back at the same time. B) Remove the air tube cover plate. 5, by loosening the retaining screw. 6. C) Slide the complete drawer assembly into the combustion head. as shown. and secure it in place with screw, 7. Attach the fuel line to the pump. E) Replace the air tube cover plate. 5. and carefully plug in the control box. 4. reversing step A. D) Securely tighten all screws. Compliments of Aspen Gas & Oil Services Ltd Page 8 of 12 1-250-489-3780 866 802 3641

ELECTRODE SETTING IMPORTANT THESE DIMENSIONS MUST BE OBSERVED AND VERIFIED NOTE: ELECTRODES ARE PRESET AT THE FACTORY PUMP PURGE (see figure 10) A) Gravity System. Remove the plug 7 and wait for the fuel oil to flow from the tank. B) Lift System. Start the burner and wait for IGNITION. Should lock-out occur, wait at least 20 seconds, then re-set primary control. Repeat this operation until the pump is primed. C) Either System (preferred manner): Turn off the main power to burner and remove the control unit. Using a short jumper cable, connect pin 5 and pin 6 of the control plug-in socket. Return the power to the burner. When the pump is sufficiently purged, the automatic air shutter will activate. Once the burner is purged, turn off all power to the burner, remove the jumper cable and replace the control unit. Return power to the burner. The burner is now ready to operate. ATTENTION It is important that the fuel line be completely sealed and free from air leaks or any internal blockages. WARNING WHEN THE BY-PASS PLUG IS INSTALLED,A TWO PIPE SYSTEM MUST BE USED. REGULATION OF THE TURBULATOR AND Am SHUTTER FOR PROPER COMBUSTION A) TURBULATOR SETTING (see figure 15) 1) Loosen nut, 1, then turn the screw, 2_ until the index marker, 3, is aligned with the correct index number as per Table B, column 4. 2) Retighten the retaining nut, 1. B) AIR SHUTTER SETTING (see figure 16) 1) Loosen the retaining nut, B; turn the bolt, A, in a counterclockwise direction until about one inch of thread is visible. Using the setting taken from Table B, column 5, position the air shutter so that the top of the shutter is aligned with the proper index line indicated on the air intake. side of the burner housing. Holding the shutter in this position, turn the adjusting bolt, A, in a clock Wise direction until resistance is met. Release the air shutter, it should return to the full closed position. Compliments of Aspen Gas & Oil Services Ltd Page 9 of 12 1-250-489-3780 866 802 3641

2) Apply power to the burner, the shutter should open automatically to the preset position. Make proper adjustments for optimum efficiency. 3) The final position of the air shutter will vary on each installation. Use instruments to establish the proper settings for maximum CO2 and a smoke reading of "zero". Note: Be sure that the burner cover is in place when making the final instrument. readings as it may cause variations in these results. FIGURE 16 NOISE REDUCING PLATE (see figure 17) Should it be desired to reduce burner noise further, the cover plate, 1 (supplied with burner), can be positioned, as in figure 17, over the combustion air inlet louvers on the burner front panel. NOTE: If plate is used, all combustion tests should be done with the cover and plate in place. It must be remembered that the fan capacity with this plate in place, is greatly altered and should not be used at the burner's higher firing rates. Figure 17 Compliments of Aspen Gas & Oil Services Ltd Page 10 of 12 1-250-489-3780 866 802 3641

NOZZLES: Monarch NS; Delavan A - E - W; Steinen H - Q; Danfoss H - B. Angle: 60 degrees in most cases. 80 degrees in cases of flame detachment, during ignitions at low ambient temperatures. COMBUSTION CHAMBER Follow the instructions furnished by the boiler/furnace manufacturer. No refractory is required. A tar get wall at the far end of the combustion chamber is useful, but not necessary. The combustion chamber dimensions listed in Table C are minimums. The center line of the combustion head should be placed along the center line of the chamber area. Compliments of Aspen Gas & Oil Services Ltd Page 11 of 12 1-250-489-3780 866 802 3641

FOR CANADA PRECAUTIONS Air for combustion: Do not install burner in room with insufficient air for combustion. It might be necessary to create a window to permit sufficient air to enter the boiler!.;: furnace room. The installer must follow local ordinances in this regard.: Should local ordinances be lacking it is suggested the installer follows installation code for oil burning equipment, CSA standard B 139. Chimney: Be sure chimney is sufficient to handle the exhaust gases. It is recommended that only the burner be connected to the chimney. Be sure that it is clean and clear of obstructions. Filter: An external filter is REQUIRED even though there is an internal strainer in the pump. The filter should be replaced at least once a 'year and the filter container should be thoroughly cleaned prior to installing a new filter cartridge. Draft: Follow the instructions furnished with the heating appliance. The pressure in the combustion area should be kept as close to zero as possible. The burner will operate with a slight draft or pressure in the chamber. Electrical Connections: All electrical connections should be done in accordance with the C. E. C. point I and all local codes. The system should be grounded. Control Burner Operation: Check out the burner and explain its operation to the homeowner. Attention: Be sure there is an adequate air supply for combustion if the boiler furnace room is enclosed. Fire Extinguisher: If required by local codes, install an approved fire extinguisher. Compliments of Aspen Gas & Oil Services Ltd Page 12 of 12 1-250-489-3780 866 802 3641