K6C Summit Multi Oil Warm Air Furnace SAVE THESE AND BURNER INSTRUCTIONS FOR REFERENCE
|
|
|
- Prosper Austen Simpson
- 9 years ago
- Views:
Transcription
1 K6C Summit Multi Oil Warm Air Furnace SAVE THESE AND BURNER INSTRUCTIONS FOR REFERENCE HOMEOWNER AIR FILTERS To maintain furnace performance and safety, replace dirty filters as required or at least once every heating season. Use new approved disposable filters of the same size, or clean permanent filters according to manufacturers instructions. Replace the filters or clean the filter more often if dusty conditions exist. Dirty, clogged or wrongly sized filters will impair the furnace performance and may cause the furnace to shut down or overheat. HOMEOWNER REGULAR MAINTENANCE Have qualified technician check complete furnace operation at least once a year. HOMEOWNER DIRECT VENT It is the responsibility of the homeowner to ensure that the area around the Direct Vent Terminal and air intake is free of snow, ice, and debris. HOMEOWNER RESTARTING FURNACE Follow this procedure before restarting a unit that has been shut down for an extended period of time. INSPECTION Have the furnace/system serviced and inspected by a qualified technician. NEVER BURN GARBAGE OR PAPER IN THE UNIT AND NEVER STORE COMBUSTIBLE MATERIAL AROUND IT. CHECK Furnace/system has not been tampered with. DO NOT ATTEMPT TO START BURNER WHEN EXCESS OIL HAS ACCUMULATED, WHEN UNIT IS FULL OF VAPOUR, OR WHEN HEAT EXCHANGER IS VERY HOT. DO NOT USE GASOLINE, CRANKCASE DRAININGS OR ANY OIL CONTAINING GASOLINE. HOMEOWNER SHUTTING FURNACE DOWN POWER OFF Turn off main power switch FUEL ON & CHECK Turn on fuel supply and check that there are no leaks. POWER ON & CHECK Turn on power switch and check that the furnace starts and operates as usual. CHECK OPERATION: If the furnace/system fails to operate or operates in an unusual manner, call your service technician. If the burner fails to operate at any time, call a qualified burner technician. FUEL OFF Shut off manual fuel supply valve ALWAYS KEEP MANUAL FUEL SUPPLY VALUE SHUT OFF IF THE BURNER IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME. Installed by: Address: Telephone: Date: IMPORTANT Read this instruction sheet thoroughly before installing furnace or starting burner. Consult local authorities about your local Fire Safety Regulations. All installations must be in accordance with local state or provincial codes. Improper installation will result in voiding of warranty. CAUTION DO NOT START THE BURNER UNTIL ALL FITTINGS, COVERS AND DOORS ARE IN PLACE. DO NOT TAMPER WITH THE FURNACE OR CONTROLS, CALL A QUALIFIED BURNER TECHNICIAN. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance. INSTALLATION CODES INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, and the Installation Code for Oil Burning Equipment (USA NFPA31, or Canada CSA B139) and the USA National Electrical Code NFPA 70 or the Canadian Electrical Code. For chimney and ductwork (NFPA 90A/B) see required codes. Certified to CSA and UL requirements. Use only nozzles and settings shown on the appliance label. Use approved fittings, tubing, fuel tank, oil shut off valves etc. MULTI-POSITION The Summit Multi is designed to operate in the conventional upflow mode, or in horizontal mode. The breech is convertible from front to rear by switching the breech pipe and cover plates. The burner is always installed in an upright position by four nuts. PLACEMENT, VENTING, VENTILATION Furnace installation should conform to the required installation code for oil-fired equipment (USA: NFPA 31, Canada: CSA B139) HORIZONTAL CLEARANCES LOCATION BREECH CHIMNEY/VENT THROUGH the WALL VENTING COMBUSTION & VENTILATION AIR In suspended horizontal positions use the eyebolts provided. For installations where the furnace will be supported from below, use 4 long 3/8 UNC bolts as adjustable legs. Before placing unit, review installation clearances as shown on furnace settings label. Install the furnace close to chimney or vent and central to ductwork. Move the breech pipe to the rear if rear breech is required. Connect the furnace to a chimney/vent system of size and condition required by the Installation Code. FURNACE IS APPROVED FOR FACTORY BUILT CHIMNEY TYPE A OR TYPE L VENT. See furnace marking label for approved vent/flue pipe sizes. MAXIMUM FLUE GAS TEMPERATURE IS 575 F. Furnace is approved for Kerr Direct Vent Install openings and ductwork to the furnace room to provide fresh outside combustion air and circulation air for cooling the furnace casing as installation code requires (USA: NFPA 31, Canada: CSA B139). If installed in a closed room provide two free air ventilation openings of at least 8 x 12 free flow area near ceiling and floor. Oil burners must have sufficient air to allow vent systems to operate properly. See furnace operating label. Not applicable to Direct Vent. UPFLOW If required, support furnace on 4 concrete blocks. Make sure each corner of furnace base is supported. For a furnace installed on a combustible floor, ensure that the requirements of the authorities having jurisdiction are satisfied. Floor must be strong enough to carry the weight of the furnace. CERTIFIED TO CAN/CSA Std. B140.0 Std. B140.4 CONFORMS TO UL 727
2 INSTALLATION Return Air Plenum The return air filter assembly is inter-changeable with the left or right side panel, and also with the base pan depending upon the furnace operating position. An optional painted side panel is available to replace the unpainted base pan if requested. Please contact your local Kerr dealer. ELECTRICAL VENT PIPE BREECH DRAFT CONTROL Wire according to the National Electrical Code (Canadian Electrical Code in Canada) or local codes. Use a separately fused #12 electrical line directly from the service panel to the furnace junction box. Install a manual shut off switch at the door or stairway to furnace room so furnace can be shut off remotely. See NFPA 31 (USA) or CSA B139 (Canada) code. Breech is certified for 5 vent pipe. Keep vent/flue pipe as short as possible with min. 1/4 per foot upward slope. Use approved fitting through a wall. Vent/flue pipe MUST NOT pass through a ceiling. The breech is convertible from front to rear by switching the breech pipe and cover panels. Use approved control supplied for 5 pipe. Use two draft controls on strong draft chimneys. Set specified draft pressure to wc. The above is not applicable to Direct Vent installations. ASSEMBLE and INSTALL BURNER ASSEMBLE BURNER Check burner model is correct for furnace rating required. Assemble as per burner manufacturer s instructions. SET END CONE BECKETT AFG Use low firing rate baffle with 0.65 nozzle and lower- see instructions RIELLO Set turbulator on furnace settings label SELECT NOZZLE Select oil input, nozzle required and burner configuration as shown on furnace label settings. INSTALL NOZZLE CHECK ELECTRODES INSERTION LGTH MOUNT BURNER PUMP BY-PASS PLUG COMPLETE WIRING THERMOSTAT CHANGING NOZZLE NOZZLE CHANGE Install selected nozzle, check for clean seating and tighten in nozzle adaptor. See burner instructions for correct setting. See diagram and specifications on this sheet. Tighten top nut first so burner tips down slightly. The burner is always installed in an upright position by four nuts. For one pipe system BECKETT, and RIELLO as factory setting (no plug). Refer to wiring diagram or furnace label for correct burner connections. Connect thermostat terminals. If a new nozzle of a different size is installed, change the heating blower speed according to the specifications table. SET BURNER FOR EFFICIENT OPERATION SET END CONE BECKETT MB air tube with L1 head RIELLO Set turbulator to furnace label settings. PUMP PRESSURE BECKETT 140 psi. Check settings label. RIELLO psi. Check settings label. BURNER AIR BECKETT AFG Set as burner manual, use low firing rate baffle with 0.65 nozzle and lower. RIELLO Set air damper as settings on label. SAMPLING HOLE On smoke/vent pipe, between appliance breech and (Non Direct Vent Only) draft control, punch or drill a 1/4 round opening. Not applicable to Direct Vent. DRAFT PRESSURE Using an accurate draft meter, adjust the draft control (Non Direct Vent Only) to obtain -.04 wc draft pressure at the breech sampling hole. Use two barometrics if necessary. BURNER SETTING EFFICIENCY DO NOT start burner until all fittings and covers are in place. Set the burner to give a stable symmetrical flame After 15 minutes of normal operation, check SMOKE for #0- trace reading and measure CO 2 Read just the burner controls as required. Always leave burner set with CO 2 reading about 1% of CO 2 lower than the peak efficiency achieved with a #0- trace smoke (eg a #0-trace reading of 12.5% CO 2 should be set back 1% to 11.5%). This gives better allowance for fuel and draft variations and maintains a better seasonal efficiency. When the burner is set, lock the adjustments with the locking nuts. Always set flame with proper draft, smoke and CO 2 measurements. FLAME CHECK Look through view port to check the flame after setting the burner. If the flame is not clean and sy mmetrical, reset the burner or replace the nozzle use only nozzle types specified on settings label. BLOWER SETTINGS Ensure power is off when adjusting blower setting For heating, use the blower speeds shown on the furnace specifications to give a rise of F. The #4 Lo blower speed can be used for air circulation when neither heating or cooling are required. Set blower speeds to match the installation requirements. HUMIDIFIER-Furnace If a humidifier is installed ensure that no water can drip or run from it into the furnace. This would cause deterioration and void the furnace warranty. THERMOSTAT ANTICIPATOR SETTING 0.2 amps for any burner. Check that the thermostat anticipator setting matches the primary control circuit current draw. This setting affects the thermostat s response to the control. FAN CONTROL LIMIT 200 F - Factory set FAN ON 130 F FAN OFF 100 F COMFORT ADJUSTMENTS -- Outlet air is initially too hot or too cold - adjust the fan on setting. -- Outlet air consistently too warm or too cold - change the blower motor speed to give the specified air temperature rise (70-85 F). -- Blower motor shuts off and the oil burner keeps going - the fan on setting is set too low or the inlet air is below 50 F. -- Outlet air gets too hot and burner shuts down - increase air by changing the blower motor speed to give the specified temperature rise (70-85 F) -- Outlet air is too cold or too hot at the end of the heating cycle after the burner has turned off - adjust the fan off time higher or lower. OFF CYCLE AIR CIRCULATION #4 LO SPEED All furnace models have the #4 Lo speed switch for optional constant off cycle air circulation. REGULAR MAINTENANCE AND CLEANING Check complete operation at least once a year. In Canada see B139, Section 14, Maintenance, for recommended servicing procedure. Heat exchanger ducts are accessed through access panel at front of unit. Clean flue pipes on a regular basis. Replace flue pipes if there is any sign of corrosion or other problem. TROUBLESHOOTING GUIDE Furnace will not start Blown fuse No oil Repair with new fuse Call oil supplier Oil burner keeps turning off Dirty air filter Change air filter Restricted air supply Check all air return/supply registers Limit control Check blower motor speed. Speed blower up Motor over heating Check motor speed correct for nozzle on furnace label settings. Dirty nozzle Call mechanic to replace nozzle. Sooty flame Wrong pump pressure Increase pressure to correct setting. Dirty nozzle Replace nozzle. Improper burner air setting Increase burner air- see BURNER SETTING. Barometric draft wrong Adjust barometric regulator for wc draft pressure at breech.
3 Using too much oil Oil leak in line or tank Draft regulator set high Nozzle too large Burner reset cuts out No oil Frozen oil line Dirty oil filter Dirty nozzle, smoky fire Faulty oil pump Faulty or dirty electrodes Check fittings for tightness. Inspect tank and replace if necessary. Adjust regulator for wc draft pressure at breech. Replace nozzle to lower input. Call oil supplier. Call technician or oil supplier. Replace filter Replace nozzle, adjust burner air. Have pump replaced, adjust burner air. Have technician clean or replace. BLOWER REMOVAL PROCEDURE Use a reversing drill with 1/4 inch hex drive for the sheet metal screws. The KERR K6C SUMMIT has a quick release blower suspension system which is designed to be tight and rattle free. 1. Disconnect power. 2. Remove front panel to blower compartment. 3. Remove the screw (s) from the blower key. (Fig. 1) 4. Remove the blower key and slide the blower towards the burner. (Fig. 2) Replace the blower assembly using the reverse procedure. Warm air register blowing cold air Circulation fan switch is on Switch off blower circulation fan switch FAN OFF setting is high Fan control Set FAN OFF lower. Basement cooling ducts Insulate ductwork to maintain duct temperature. Motor speed set too high Reset motor speed to slow blower. All rooms at different temperatures Supply air not regulated Adjust warm air regulators to suit each room. Noisy Operation Loose blower wheel Damaged motor bearings Faulty oil pump Air leak in oil line Tighten wheel set screw or replace. Replace blower motor. Repair or replace oil pump. Reset to correct pressure. Tighten all connections. Warm air registers blowing too hot Blower running slow Speed blower up by rewiring to higher speed Make sure blower motor current is within motor rating. Return air restricted Open up return air duct work to ensure adequate air flow. OIL TANKS AND PIPING Tank installation should conform to local requirements Install according to code. Minimize number of connections in suction line and make all connections as tight as possible. Use a good pipe joint compound for oil on all pipe threads. To reduce possibility of air leaks, tighten stem packing gland nut on any valves installed in the suction line. Also, be sure the oil filter is tight, as filter gaskets often shrink. Check for kinks in the oil lines as well as for possible air pockets and for loose connections. ONE PIPE SYSTEM TWO PIPE SYSTEM Where the tank is above the burner and when the oil flows by gravity to the oil pump, a single-stage fuel unit with a single oil line to the pump may be used. When single line is unsuitable, use double line or see your KERR dealer for special oil line fittings. Install tank system to code requirements See your KERR dealer for information on tank system Always use a good quality 10 micron oil filter such as Kerr K10. Install appliance in accordance with Installation Codes (USA NFPA 31 or Canada CSA B139) and local regulations. Oil filter appliances shall be connected to flue or vents having sufficient draft at all times to ensure safe and efficient operation of the appliance.
4 SETTINGS K6C SUMMIT - MULTI OIL FURNACE Model Burner Input Nozzle Pump Air Setting Turbulator Output Blower Motor K6CG-120(A3) K6CC-120(A3) K6CE-110(A3) K6CE-120(A3) Beckett AFG PA402 Carlin EZ-1HP Riello 40 F3 Riello 40 F5 Heating cfm@ Blower Speed USGPH L/h (psi) Btu/h kw 0.2"wc 0.5"wc 0.2"wc 0.5"wc A* 8.0/0.0* 83, A* 7.5/1.0* 90, A 8.0/ , A 7.0/ , A / , A , W , W , W , W , K6CV-090(A3) Riello 40 BF3*** B** , K6CV-120(A3) Riello 40 BF5*** B , W , K6CD-120(A3) Beckett AFG PA404*** B 80* **** 83, B 110* 90, B , B , K6CG-120(A5) Beckett AFG PA A / , GT /4 hp A 7.0/ , A / , K6CC-120(A5) Carlin EZ-1HP GT /4 hp A , W , K6CE-160(A5) Riello 40 F W , GT /4 hp W , W , B , K6CV-145(A5) Riello 40 BF5*** W , GT /4 hp K6CD-120(A5) Beckett AFG PA404*** W , B , GT /4 hp B , * Low firing rate baffle required Set flame to #0-1 smoke after CO 2 test. ** Use Hago 70B Nozzle Use turbulator and air settings as guide *** Direct Vent Models **** Use Air Boot Flow Restrictor Beckett: Air Shutter/Air Band For 4 Ton AC use Blower Speed 2 (Blue Wire) with ¾ hp motor (1600 cfm) Burner Insertion: 2-1/2 (63mm) For 5 Ton AC use Blower Speed 1 (Black Wire) with ¾ hp motor (2000 cfm) CLEARANCE TO COMBUSTIBLES Top 1 Front 24 Rear 24 Side (access) 6 (24 ) Flue Pipe 9 Floor Non-combustible DRAFT PRESSURE (not applicable to Direct Vent) Breech draft pressure Overfire draft pressure wc wc BURNER INSERTION (overall) in mm Motor/Blower ½ hp 4 Speed/GT ¾hp 4 Speed/GT AIR/BLOWER DATA see table above External static standard model 0.2 wc External Static A/C models 0.5 wc Maximum air temperature rise 85 F High limit, max design outlet temp 200 F Thermostat anticipator 0.2 amps AIR FILTERS All models (Pleated) FAN/HIGH LIMIT CONTROL Honeywell L6064 CLEANOUTS Smoke pipe cover, Burner opening SMOKE/VENT PIPE 5 Fuel not heavier than No. 2 furnace oil. 20 x25 x2 DIMENSIONS in mm Depth Height 52½ 1333 Width PLENUM DIMENSIONS Cold air return 19 x 20½ 483x521 Hot air supply 23¾ x 20½ 603x521 OPENING HEIGHTS from floor Burner c/l 27½ 699 Smoke pipe c/l 44½ 1130 ELECTRICAL 120 Volts, 60Hz Canada USA less than 14 amps 13 amp, circuit protection 20 amps Parrsboro Metal Fabricators Limited 2002 P.O. Box 637, Parrsboro, NS B0M 1S0 Canada 09/02
5
6
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
OTF Oil Fired Pool Heater
OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
HEAT WAVE DUCT KIT KIT # 946-568
HEAT WAVE DUCT KIT KIT # 946-568 www.regency-fire.com Approved for use with Models: P36, P36D, P42, P48, P90, P95, L676S, P33S & HZ54 WARNING: Improper installation, adjustment, alteration, service or
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.
INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and
Installation Instructions
VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
ASX7-4-IOM-7 J30-08579
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
SIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02
SIBIR MANUAL RKE - 1D V110 KE English page 5 822 70 66-02 2 1 A. Flue tube E. Adapter I. Thermostat B. Flue baffle F. Burner base J. Lever arm C. Control knob G. Lamp glass D. Fuel gauge H. Lamp glass
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Diagnostics for Mobile Homes: HVAC
Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests
E2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
F9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
TECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.
FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
Commercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Annual Service Agreement
Annual Service Agreement 462 Main Street P.O. Box 130 Royersford, PA 19468 610-948-7220 www.plottsenergy.com GAS OIL HEAT PUMP AIR CONDITIONING A family owned and operated business since 1949. We are here
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
NFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
GAS SAFETY PRECAUTIONS
GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.
Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
Oil - kerosene burners
Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
THREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information
Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...
Operator: Save these instructions for future use!
WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE
heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.
3 & cooling 17 heating 2010 PulteGroup, Inc. All Rights Reserved. condensation The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. Air conditioning
MODEL HS OIL BURNERS. Publication Date 8/01/01 Revision 12 Manual 21663 U.S. Patent No. 4,388,064
MODEL HS OIL BURNERS 801 Glasgow Ave. Fort Wayne, IN 46803 Publication Date 8/01/01 Revision 12 Manual 21663 U.S. Patent No. 4,388,064 ELECTRIC SHOCK HAZARD HIGH VOLTAGES ARE PRESENT IN THIS EQUIPMENT.
Central Air Conditioner
Central Air Conditioner USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL AIR CONDITIONER NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
Installation Instructions
CNPVU CNRVU Uncased Coils Upflow - Downflow Heating - Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting
ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or
I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION
I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety
Installation Instructions ERV/PRV Downdraft Vent
Installation Instructions ERV/PRV Downdraft Vent Tested in accordance with the latest edition of ansi z 21.1 standard for household gas cooking appliances, ANSI/UL 858 household electrical ranges, can/csa-c22.2
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL Boiler Manual A. INSTALLING EXHAUST VENT AND INTAKE AIR VENT B. GENERAL n DANGER The Elite Heating Boiler must be vented as detailed in this section.
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
SERVICE DIAGNOSIS Modine heating & ventilating equipment
75-551.5 December, 2003 SERVICE DIAGNOSIS Modine heating & ventilating equipment A Problem/Remedy Guide for Modine: Gas-Fired Unit Heaters Gas-Fired Duct Furnaces Steam/Hot Water Unit Heaters Electric
Installation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!
Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger! All installation, burner set-up and adjustment, and maintenance operations
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped