High Challenge Warehouse Fire Protection Strategies

Similar documents
Flammable and Combustible Liquid

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Flammable and Combustible Liquids. Slide 1 (of 23)

Laboratory Safety Manual

Queen's University Environmental Health and Safety

OSHA Office of Training and Education 1

Material Safety Data Sheet

Notes. Material 1. Appropriate Flammable Liquids

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Alcohols An alcohol contains a hydroxyl group ( OH) attached to a carbon chain. A phenol contains a hydroxyl group ( OH) attached to a benzene ring.

Copyright 2010 Pearson Education, Inc. Chapter Fourteen 1

Solvents: Theory and Application

Contact Angle and Surface Energy Measurements on Steel

Standard Operating Procedure

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

HAZARDOUS AREA TECHNICAL GUIDE

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Standard Operating Procedure: Flammable Liquids

FIRE HAZARD PROPERTIES. Acetaldehyde IA -38 (-39) 347 (175) (21) Yes CH 3

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

H H H O. Pre-Lab Exercises Lab 6: Organic Chemistry. Lab 6: Organic Chemistry Chemistry Define the following: a.

Fire Testing of Recycled Materials for Building Applications

9130 Kallo (Kieldrecht) Houston, TX Phone: Phone : info@monumentchemical.com Fax :

FLASH POINTS OF AQUEOUS SOLUTIONS OF FLAMMABLE SOLVENTS

Laboratory 22: Properties of Alcohols

Safe Method of Use 7 HSNO Class Flammable Liquids

Presented by: Rich Perry Marsh Risk Consulting

WORKING WITH MODERN HYDROCARBON AND OXYGENATED SOLVENTS: A GUIDE TO FLAMMABILITY

Material Safety Data Sheet

BRILLIANT TONER SERIES TONERS FOR PRINTING INKS BSTS SERIES

Alcohols. Copyright 2009 by Pearson Education, Inc. Copyright 2009 Pearson Education, Inc. CH 3 CH 2 CH 2 OH 1-propanol OH

Chapter 12 Organic Compounds with Oxygen and Sulfur

Flammable Storage in a Biotech Facility

I.CHEM.E. SYMPOSIUM SERIES NO. 97

BP WIND ENERGY POLICIES AND PROCEDURES

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FDNY C14 Certificate of Fitness Quiz

ADMINISTRATIVE SERVICES MANUAL

Fire Security Systems

Guidance Note: Chemical Storage

Distillation of Alcohol

Sample Written Program. For. Flammable Liquids

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

**** MATERIAL SAFETY DATA SHEET **** STABIL Fuel Stabilizer **** SECTION 1 - CHEMICAL PRODUCT AND MANUFACTURER IDENTIFICATION ****

MONOETHYLENE GLYCOL (MEG) (Monoethylene Glycol / MEG)

Hazard Warning Signage Guidelines

Flammable Liquids Storage

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Whoosh Bottle Safe Laboratory Practices

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Impact of Paint on Indoor Air Quality in Schools

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Sample Test 1 SAMPLE TEST 1. CHAPTER 12

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Experiment #8 properties of Alcohols and Phenols

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

Air Monitoring Guide 3500/3510, 3520/3530, 3550/3551

Experimental Determination of Flash Points of Flammable Liquid Aqueous Solutions

Antifreeze Solutions in Residential Fire Sprinkler Systems

Flammable Liquids Storage

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

Isopropyl Alcohol (IPA)

Newson Gale. Is it ever Safe to use Plastic Drums and Containers in Hazardous areas? White Paper. Author Details:

Material Safety Data Sheet

Acetaldehyde Production by Ethanol Dehydrogenation

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

Chapter 5 Classification of Organic Compounds by Solubility

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

Flammable Liquids 29 CFR

MATERIAL SAFETY DATA SHEET PAGE 1

NFPA : Basic Requirements for Storage Tanks

Selective Permeation of Solvents through Plastic Bottles

Safety Data Sheet (SDS)

Propane Fuel. Material Safety Data Sheet

Material Safety Data Sheet

SAFETY DATA SHEET INSTANT HAND SANITIZER GEL / SANTI-GEL

Phase diagram of water. Note: for H 2 O melting point decreases with increasing pressure, for CO 2 melting point increases with increasing pressure.

MATERIAL SAFETY DATA SHEET

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Chapter 14 Solutions

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks

Warehouse Checklist. Warehouse Construction

Safe Method of Use HSNO Class Flammable Liquids

Synthesis of Isopentyl Acetate

Material Safety Data Sheet Wix Diesel Fuel Additive

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

The Official NAPAonline.com E-commerce Site Shop NAPAonline

22 APR 2010 <MSDS_ID>300088</MSDS_ID> MATERIAL SAFETY DATA SHEET. <Product> PHENOLPHTHALEIN INDICATOR SOLUTION # HR </Product> Part#: N/A

Alcohols. Characterized by OH group Name: add ol. to name of hydrocarbon. Methanol. Butanol. Sterno. Alcohols burn in air. A mixture of ethanol +

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Identification of Arson Accelerants by Gas Chromatography

Classification of Hazardous Atmospheres

2. Why does the solubility of alcohols decrease with increased carbon chain length?

Transcription:

High Challenge Warehouse Fire Protection Strategies Flammable and Combustible Liquids in Ordinary, Non-listed, Nonmetallic Intermediate Bulk Containers (IBC s) Industry Perspective David P. Nugent, Valspar Corporation Paris, France 27 June 2012

Type of IBC used There are a number of critical issues to consider when utilizing IBC s: Type of liquid - physical, ignition and combustion properties Can sprinkler system mitigate a fire for a given combination? If sprinkler system can not mitigate, what exposures are you are creating?

Statement of Problem Ordinary, non-listed and non-metallic IBC's (plastic or composite) containing flammable and combustible liquids continue to present a serious fire risk (life safety and property/business interruption) to industry.

NFPA Liquid Classifications Flammable Liquid Class IA Flash Point < 22.8 o C & Boiling Point < 37.8 o C Class IB Flash Point < 22.8 o C & Boiling Point 37.8 o C Class IC Flash Point 22.8 o C & < 37.8 o C Combustible Liquid Class II Flash Point 37.8 o C & < 60 o C Class IIIA Flash Point 60 o C & < 93 o C Class IIIB Flash Point 93 o C * Based upon Closed Cup Test

Some Definitions: Flash Point: The minimum temperature of a liquid at which sufficient vapor is given off to form an ignitable mixture with air and when ignited will produce a flash fire, and not continuous flaming combustion, over the surface of the fuel. Fire Point: The minimum temperature of a liquid at which sufficient vapor is given off to form an ignitable mixture with air and when ignited will produce continuous flaming combustion, over the surface of the fuel. The fire point is typically a few degrees higher than the flash point. Liquids that have a flash point and not a fire point are not considered flammable or combustible liquids.

Some Additional Liquid Properties Flash Point, open cup ( o C) Fire Point ( o C) Heat Release Rate (kw/m 2 ) Total Heat Released (MJ/m 2 ) Solubility (Polar vs. Non-Polar)

Ordinary, Non-listed and Non-metallic IBC's

Permeation IBC's using a Polyethylene bottle are subject to softening or plasticizing" when filled with hydrocarbons.

A number of manufacturers produce materials containing various soluble solvent mixtures and water Can these blends be treated as less-hazardous liquids allowing us to develop effective and reliable sprinkler system design criteria?

Fire Test Program Phase I Ignition & combustion properties of various aqueous organic solutions Phase II Additional testing including largescale sprinklered fire tests

Sponsors 3M Corporation American Coatings Association Dow Corning Corporation Eastman Chemical Corporation Property Insurance Research Group Rigid Intermediate Bulk Container Association Sherwin Williams Silicon Environmental Health and Safety Council Valspar Corporation

Fire Risks Issues Electrostatic Ignition Potential Not Addressed in Project Ignition, Combustion Properties, & Fire Mitigation Primary Focus of Project

Aqueous Solutions Thirty aqueous blends of flammable / combustible solvents were selected and subjected to small scale testing: flash point fire point cone calorimetry

Aqueous Solutions Stable one phase systems with 2 or more components Polar (hydrophilic) & partially non-polar (hydrophobic) solvents No hydrocarbons due to permeation and protection issues Co-solvents used to enhance solubility Vary concentrations and number of components Possibly representative of a broader range of materials Partially diluted with water having a lower heat of combustion than pure materials

Various Organic Families Carboxylic acids (C 2, C 3, & C 4 ) Alcohols (C 3 & C 4 ) Ketones (C 3 & C 4 ) Glycols (C 2 & C 6 ) Glycol ethers (C 4, C 5, & C 6 )

Test Methods Closed Cup Flash Point, Seta Flash Rapid Equilibrium Method (BS EN ISO 3679:29004, equivalent to ASTM 3828) Cleveland Open Cup Flash Point and Fire Point (ASTM D92) Cone calorimetry (ASTM E1345) 100 X 100 X 10 (LWD) Incident heat flux 35 kw/m 2

Solvent List Flash Point cc o C * NFPA Class Acetone -20 IB Flammable Methyl Ethyl Ketone -9 IB Flammable Isopropyl Alcohol 13 IB Flammable Propylene Glycol Monomethyl Ether 33 IC Flammable N-butyl Alcohol 36 IC Flammable Acetic Acid 39 II Combustible Ethylene Glycol Monopropyl Ether 49 II Combustible Propionic Acid 53 II Combustible Ethylene Glycol Monobutyl Ether 62 IIIA Combustible N-butyric Acid 72 IIIA Combustible Ethylene Glycol 111 IIIB Combustible Dipropylene Glycol 121 IIIB Combustible Water N/A * MSDS

Blend # Composition (%wt/wt in water) Total Water Organic % Liquid % Flash Point cc o C NFPA Class Flash Point oc o C Fire Point oc o C 14 50% Acetone 50% 50% -12 IB Flammable < 20 < 20 16 25% Methyl Ethyl Ketone 25% 75% -4 IB Flammable < 20 < 20 15 25% Acetone 25% 75% -2 IB Flammable < 20 < 20 17 75% 2-Propanol 75% 25% 19 IB Flammable 32 32 12 50% Propanol 50% 50% 21 IB Flammable 35 35 11 25% Propanol 25% 75% 27 IC Flammable 35 43 1 20% Propanol, 12% Ethylene glycol, 30% Propylene glycol monomethyl ether 62% 38% 32 IC Flammable 39 46 2 20% 1-Butanol, 20% 2-Propanol, 30% Ethylene glycol monobutyl ether 70% 30% 36 IC Flammable 46 50 27 10% Propanol, 30% Ethylene glycol 40% 60% 38 II Combustible 52 70 3 15% 1-Butanol, 15% 2-Propanol, 30% Ethylene glycol monobutyl ether 60% 40% 39 II Combustible 52 52 6 10% 1-Butanol, 10% 2-Propanol, 20% Ethylene glycol monobutyl ether 40% 60% 41 II Combustible 56 58 4 10% 1-Butanol, 10% 2-Propanol, 30% Ethylene glycol monobutyl ether 50% 50% 43 II Combustible 58 60 13 90% Butanol 90% 10% 44 II Combustible 59 59 8 5% 1-Butanol, 5% 2-Propanol, 10% Ethylene glycol monobutyl ether 20% 80% 44 II Combustible 60 72 24 75% Propylene glycol monomethyl ether 75% 25% 45 II Combustible 59 61 9 90% Acetic Acid 90% 10% 48 II Combustible 66 92 7 5% 1-Butanol, 5% 2-Propanol, 20% Ethylene glycol monobutyl ether 30% 70% 50 II Combustible 64 80 5 5% 1-Butanol, 5% 2-Propanol, 30% Ethylene glycol monobutyl ether 40% 60% 51 II Combustible 66 84 22 50% Propylene glycol monomethyl ether 50% 50% 53 II Combustible 73 77 23 25% Propylene glycol monomethyl ether 25% 75% 65 IIIA Combustible 95 95 18 90% Butyric Acid 90% 10% No Flash N/A Not Categorized 96 104 25 75% Ethylene glycol monobutyl ether 75% 25% No Flash N/A Not Categorized No Flash 71 29 70% Dipropylene glycol * 70% 30% No Flash N/A Not Categorized > 122 > 122 10 70% Acetic Acid * 70% 30% No Flash N/A Not Categorized > 104 > 104 19 70% Butyric Acid 70% 30% No Flash N/A Not Categorized 106 110 26 70% Propionic acid 70% 30% No Flash N/A Not Categorized 57 57 60% No Flash N/A Not Categorized No Flash 79 28 40% Ethylene glycol monobutyl ether, 20% Ethylene glycol monopropyl ether 40% 20 50% Ethylene glycol monobutyl ether 50% 50% No Flash N/A Not Categorized 67 67 20% Ethylene glycol monobutyl ether, 10% Propylene glycol monomethyl 30% No Flash N/A Not Categorized No Flash 30 ether 70% 91 21 25% Ethylene glycol monobutyl ether 25% 75% No Flash N/A Not Categorized No Flash 73 * Fire Point Occurred at Boiling Point

50 40 30 20 10 1050.0 900.0 750.0 600.0 450.0 300.0 150.0 Flash Point cc oc Flash Point oc oc Fire Point oc oc HRR Max. kw/m2 0 75/25 50/50 25/75 0.0 Blend IPA/ Water % Flash Point cc o C Flash Point oc o C Fire Point oc o C Total Heat Released MJ/m 2 HRR Max. kw/m 2 17 75/25 19 32 32 218.5 894.4 12 50/50 21 35 35 175.7 739.4 11 25/75 27 35 43 76.8 532.5

100 80 60 40 20 700 600 500 400 300 200 100 Flash Point cc oc Flash Point oc oc Fire Point oc oc HRR Max. kw/m2 0 75/25 50/50 25/75 0 Blend Propylene Glycol Monomethyl Ether/Water % Flash Point cc o C Flash Point oc o C Fire Point oc o C Total Heat Released MJ/m 2 HRR Max. kw/m 2 24 75/25 45 59 61 212.2 655.3 22 50/50 53 73 77 145.9 437.8 23 25/75 65 95 95 6.6 96.7

90 80 70 60 50 40 30 20 10 0 800 700 600 500 400 300 200 100 0 Flash Point cc oc Flash Point oc oc Fire Point oc oc HRR Max. kw/m2 2 3 4 6 5 7 8 Blend # Blend # Butanol Isopropyl Alcohol Ethylene Glycol Monobutyl Ether Total Organic Water ROH/Glycol Ether Ratio Flash Point cc o C Flash Point oc o C Fire Point oc o C Total Heat Released MJ/m 2 HRR Max. kw/m 2 2 20% 20% 30% 70% 30% 1.33 36 46 50 223.3 693.2 3 15% 15% 30% 60% 40% 1.00 39 52 52 195.6 601.5 4 10% 10% 30% 50% 50% 0.67 43 58 60 164.7 464.2 6 10% 10% 20% 40% 60% 1.00 41 56 58 136.5 387.8 5 5% 5% 30% 40% 60% 0.33 51 66 84 134.5 376.3 7 5% 5% 20% 30% 70% 0.50 50 64 80 87.6 383 8 5% 5% 10% 20% 80% 1.00 44 60 72 45.7 240.4

Phase I Test Report Fire Performance of Ordinary, Non-listed and Non-metallic IBCs with Aqueous Solutions of Flammable and Combustible Liquids Phase 1: Small Scale Testing of Solutions Health & Safety Laboratory Harpur Hill, Buxton Derbyshire, UK

Full-Scale Testing Explore which aqueous solvent mixtures stored in ordinary, non-listed IBC s can be protected with conventional sprinkler systems considering these options: Water Foam-water Palletized using ceiling sprinklers Rack using in-rack sprinklers with and without barriers

Full-Scale Testing These aqueous solvent mixtures stored in ordinary, nonlisted IBC s need to be compared against: Empty, ordinary, non-listed IBC s Ordinary, non-listed IBC s filled with non-ignitable liquids Ordinary, non-listed IBC s filled with pure oxygenated hydrocarbons

Questions? dnugent@valspar.com