Patch Cord Wiring Guide

Similar documents
Panduit 28 AWG Patch Cords Installation Guideline

Connectors and Cables

Network Cabling Guide

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Connector and Cable Specifications

Ethernet Patch Cord Wiring

Chapter 4 Connecting to the Internet through an ISP

Packet Tracer - Connecting a Wired and Wireless LAN Topology

Cable Specifications and Information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Cable Specifications and Information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Network Design. Yiannos Mylonas

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Cabling Guide for Console and AUX Ports

Serial Cables & Adapters

Cable Pinouts. SRP I/O Module

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Connecting Hosts and Routers

Appendix C. Network Requirements. The Browser Interface. For Windows

Chapter 2 TCP/IP Networking Basics

GEU Port Gigabit Switch

KVM - DVI, USB 2.0, Cat 5 Extender

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

InstaPATCH Cu Cabling Solutions for Data Centers

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Appendix B Network, Routing, Firewall, and Basics

Power, Cable, and Antenna Connection Procedures

Wightman Telecom Wireless Router Quick Reference Booklet

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Solar monitoring gateway quick start guide

3 KRONE s 25-Pair FT Block is the perfect replacement

Accelerating Light. Copper Cabling Solutions. Category 6A

SMARTen 24 STP Patch Panels

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

iseries Ethernet cabling and configuration requirements

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

ethernet connection For more information about the printer's ethernet feature, click the topic below: ethernet lights network configuration page

Data Centre & Enterprise Solutions. RapidNet

Making a DB to RJ45 adapter.

CCNA Discovery Chapter Four

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Cable Specifications. T3 Trunk Cabling APPENDIX

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Data Center Architecture with Panduit, Intel, and Cisco

Cable Connection Procedures for Cisco 1900 Series Routers

1 crossover cable. the PCs. network

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

IT Cabling Solutions

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Connecting the Console Port to a PC

SMARTen 24 UTP Patch Panels

PROFINET Diagnostics Software and Tools

Westell VERSALINK GATEWAY (MODEL 327W) Quick Start Guide Rev. A May 2004

Terminating 25-Pair Cable and 4-Pair Cross Connects

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Network Infrastructure Security Solution

Power over Ethernet with Panduit Copper Cabling

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

Ethernet Cat 5e & Cat 6 Patch Panels

Network Infrastructure Security Solution

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Innovative Connectivity Solution for Maximum Performance and Security

IP Networking Primer. Presented by: Michael Leary

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Design Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.

Gigabit Switching Ethernet Media Converters - Product User Guide

Comtrol Cable User Guide

USB Rover port USB m Cat 5 Extender. User Guide

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Introduction to Computer

Encore Controller to Router Connections

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Telebyte 209 Short Haul Modem

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

MDI/MDIX) FEP-32008T-3

E Series. E Series. Category 6 and 5e. Features

Lightning Protection Guide. PTP 400 and 600 SERIES

LMR8TT Mini 10BASE-T Hub/Repeater

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

DSL Installation Guide

IP DSLAM IDL Quick Installation Guide

Transcription:

Patch Cord Wiring Guide TECHNICAL REFERENCE Introduction Panduit is a leading supplier of structured cabling systems and Unified Physical Infrastructure (UPI), enabling the physical infrastructure to be scalable, flexible, and easily manageable, while supporting Ethernet communications at ever-increasing data rates. Panduit is aware of confusion in the marketplace regarding patch cord wiring schemes and when they should be employed. These wiring schemes include T568A, T568B, crossover (flipped), and rolled (roll-over).the purpose of this technical reference is to eliminate any confusion, by providing an overview of each wiring scheme as well as typical deployment strategies in structured cabling systems. T568A & T568B Wiring T568A and T568B wiring schemes are defined in the ANSI/TIA-568-C.2 standard for 4-pair (8-position, 8-conductor) RJ45 interfaces. T568A and T568B are straight-through wiring schemes. Each conductor inside the patch cable connects to the same pin on both modular plug ends. As shown in the illustration below, the only difference between T568A and T568B is the orientation of the green and orange pairs. When used in traditional fashion, there is no functional difference between patch cords with T568A or T568B wiring schemes. Both wiring schemes are acceptable in network topologies, and are essentially interchangeable. T568A is the default wiring scheme in ANSI/TIA-568-C.2, with T568B listed as being optional. ANSI/TIA-568-C.2, is the most popular wiring scheme in modern installations. T568B is also consistent with the older AT&T 258A wiring scheme that many installers are already accustomed to. The US Government has standardized on T568A. It is the required wiring scheme for all government installations and in all performance categories. Although completely interchangeable in traditional plug-to-plug form, installers must be cognizant of the patch cord wiring scheme if they cut the patch cord to terminate a jack module on one end. This technique is often used when the modular plug is connected to a switch, and the jack module is installed in a modular patch panel. To web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 1

ensure the jack-to-plug link transmits Ethernet traffic, the jack module must be terminated using the same wiring scheme as the patch cord modular plug. Installers appreciate that the termination cap on all Panduit jack modules includes a wire map label that illustrates the correct conductor positions for T568A and T568B termination. Panduit manufactures a complete line of patch cords in Category 6A, 6, and 5e performance categories. These include UTP, shielded, standard diameter, small diameter (SD), in CM and/or LSZH flame ratings. The table below summarizes Panduit s patch cord offerings and the part numbers for each cord wired T568A or T568B. T568A & T568B Wiring Patch Cord s Standard T568 Wire Scheme Alternate T568 Wire Scheme Cat 6A UTP (CM) T568B UTP6A**xx T568A UTP6A**xxA/N Cat 6A UTP (LSZH) T568B UTP6AL**xx T568A UTP6AL**xxA/N Cat 6A SD UTP (CM) T568B UTP6ASD**xx T568A UTP6ASD**xxA/N Cat 6A SD UTP (LSZH) T568B UTP6ASDL**xx T568A UTP6ASDL**xxA/N Cat 6A Shielded (CM/LSZH) T568B STP6X**xx T568A STP6X**xxA/N Cat 6 UTP (CM) T568B UTPSP**xxY T568A UTPSP**xxA/NY Cat 6 UTP (LSZH) T568B UTPSPL**xxY T568A UTPSPL**xxA/NY Cat 6 SD UTP (CM/LSZH) T568B UTP28SP**xx T568A UTP28SP**xxA/N Cat 5e UTP (CM) T568A UTPCH**xxY T568B UTPCH**xxB/NY Cat 5e UTP (LSZH) T568A UTPCHL**xxY T568B UTPCHL**xxB/NY Cat 5e SD UTP (CM/LSZH) T568A UTP28CH**xx T568B UTP28CH**xxB/N Cat 5e Shielded (CM/LSZH) T568A STPCH**Bxx T568B STPCH**BxxB/N ** = Length xx = Color Code /N = Non-Standard Panduit s standard Category 5e patch cords are wired T568A at the factory with standard Category 6A and Category 6 patch cords are wired T568B. Through extensive validation testing, Panduit confirmed improved Near End Cross Talk (NEXT) margins were obtained by wiring higher bandwidth cords to T568B. The reason relates to the pair lays within the patch cable, and how the conductors are manipulated into position within the modular plugs. web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 2

Crossover (Flipped) Wiring TECHNICAL REFERENCE Although not specifically defined in ANSI/TIA-568-C.2, crossover patch cords, also known as flipped patch cords, are used to connect a PC directly to another PC, a hub to hub, or switch to switch. The term crossover is used because the send and receive pairs are crossed from one modular plug (end 1) to the other (end 2). Most modern hubs and switches have auto-sensing ports that allow the use of straight patch cords (T568A or T568B) for direct connections; however, regardless of equipment capabilities, many installers prefer the use of crossover cords for all direct connections. For visual differentiation, it is common for crossover cords to be deployed in a different color than standard straight-through cables. Users should be aware that many low end crossover cords on the market support data transition rates of only 10/100 megabits per second. This is because only 2 of the 4 conductor pairs have been crossed. As shown in the illustration below, Panduit cords crossover all 4 pairs. Known as full crossover, Panduit cords transmit data on all 4 pairs at speeds up to 1 gigabit per second. Because of their popularity, Panduit stocks a standard offering of Category 6 UTP crossover patch cords. Standard foot lengths include 2 to 10 feet (one foot increments) 15 and 20 feet. Standard meter lengths include 2 to 5 meters (one meter increments) 1 and 1.5 meters. Standard colors are RD (Red), YL (Yellow), and GY (Gray). The table below shows the part number matrix for these standard cords. Cross Over Patch Cord s - Standard Cat 6 UTP (CM) ** = Length xx = Color Code UTPSP**xxFY web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 3

The table below provides a part number matrix that should be referenced when ordering a crossover cord in different performance levels, lengths, and standard colors. Cross Over Patch Cord s Cat 6A UTP (CM) UTP6A**xxF/N Cat 6A UTP (LSZH) UTP6AL**xxF/N Cat 6A SD UTP (CM) UTP6ASD**xxF/N Cat 6A SD UTP (LSZH) UTP6ASDL**xxF/N Cat 6A Shielded (CM/LSZH) STP6X**xxF/N Cat 6 UTP (CM) UTPSP**xxF/NY Cat 6 UTP (LSZH) UTPSPL**xxF/NY Cat 6 SD UTP (CM/LSZH) UTP28SP**xxF/N Cat 5e UTP (CM) UTPCH**xxF/NY Cat 5e UTP (LSZH) UTPCHL**xxF/NY Cat 5e SD UTP (CM/LSZH) UTP28CH**xxF/N Cat 5e Shielded (CM/LSZH) STPCH**BxxF/N ** = Length xx = Color Code /N = Non-Standard Rolled (Roll-Over) Wiring Rolled (roll-over) patch cords are not used for network connectivity. These patch cords serve a unique purpose, and are used to connect the serial port or modem on a PC to the console port of a Cisco^ router or switch. Rollover patch cords are often referred to as Cisco console cables because they facilitate the configuration of a Cisco network router or switch from a PC. An RJ45 to DB9 or RJ45 to DB-25 adapter will be needed to connect the cord to the PC serial port or modem. As shown in the illustration below, a roll-over patch cord completely reverses the pin configurations between the two modular plugs. Pin 1 on modular plug end 1 connects to pin 8 on modular plug end 2. Pin 2 on modular plug end 1 connects to pin 7 on modular plug end 2, and so on. web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 4

Rolled (roll-over) wiring is also available in all Panduit patch cord types. The table below provides a part number matrix that should be referenced when ordering rolled patch cords in different performance levels, lengths, and standard colors. Rolled Patch Cord s Cat6A UTP (CM) UTP6A**xxR/N Cat6A UTP (LSZH) UTP6AL**xxR/N Cat6A SD UTP (CM) UTP6ASD**xxR/N Cat6A SD UTP (LSZH) UTP6ASDL**xxR/N Cat6A Shielded (CM/LSZH) STP6X**xxR/N Cat6 UTP (CM) UTPSP**xxR/NY Cat6 UTP (LSZH) UTPSPL**xxR/NY Cat6 SD UTP (CM/LSZH) UTP28SP**xxR/N Cat5e UTP (CM) UTPCH**xxR/NY Cat5e UTP (LSZH) UTPCHL**xxR/NY Cat5e SD UTP (CM/LSZH) UTP28CH**xxR/N Cat5e Shielded (CM/LSZH) STPCH**BxxR/N ** = Length xx = Color Code /N = Non-Standard Summary Panduit, a leading supplier of structured cabling systems and UPI, has the capability of manufacturing any patch cord with a T568A, T568B, crossover (flipped), or rolled (roll-over) wiring scheme. These cords can be manufactured in any cord type, length, or standard color. Contact Panduit customer service to initiate your order for any patch cord described in this technical reference. web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 5