Shingle Installation / Fixing Specification

Similar documents
Western Red Cedar Shingles Product Guide

JBCEDAR SHINGLES & SHAKES

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Asphalt Shingle Application Requirements

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Cupa Natural Slate Roofing design and fixing guide

Residential Roofing Guide

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Western Red Cedar Shingles & Shakes

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

SHINGLE APPLICATION GUIDE

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Chapter 9: INSTALLING ROOFING

How To Build A Gambrel Roof And A Gable End Roof

Multi-layer Insulation Blanket for Roofs

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

UNIT 4: SHEATHING AND SHINGLING THE ROOF

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Technology at its best. Benefits

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Detached accessory structures that contain no conditioned floor area are exempt.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Ubiflex. Non-lead flashing system

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

SECTION PREFORMED METAL STANDING SEAM ROOFING

HfHMD uses LP SmartSide siding and trim.

Directions For Applying Malarkey Laminate Shingles

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

VM ZINC : standing seam Guidelines for specification and installation

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

application instructions

The formation of roof waterproofing details calls for

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Shingle Installation Guide

ROOF ASSEMBLIES CHAPTER 9

Chapter 6 ROOF-CEILING SYSTEMS

Under Tile and Slate Undersheeting System

INSTALLATION OF A BAY WINDOW

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

CHAPTER 7: Building Systems ROOFING SYSTEMS

Interlocking tiles and slates

K2 STONE NATURAL VENEER

Retrofitting an Insulated Cold Roof

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Rockwool Flexi Insulation Application Guide

Roofers Guide to Underslating Membranes

Post and Beam Construction

Epdm Flat Roofing Systems

Including. Rubershield-Pro. Breather Membrane

Installation Manual for STANDING SEAM ROOFING

SUPER SHED. Indoor shelter for your outdoor tools.

V-joint fascia soffit systems

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Best Barns USA Assembly Book

SECTION STANDING SEAM METAL ROOFING

Mark Cramer Inspection Services, Inc.

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Materials and Colors

Tried, Tested and Proven Timber Protection

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Clay Roof Tile Council. Vertical Tiling

FS Deck Mounted Skylight Installation Instructions 15-90

HCD DSA OSHPD 1 2 1/AC AC SS

Barewood Octagon and Elongated Windows Installation Instructions

CI/SfB (Ff3) January Roofing design guide. Showing you the way. Redefining traditional products

Ridge. Hip. Abutment. Eaves. Roof slope. Vertical slating. Clay plain tiles. Valley. Ridge Roll. Verge. Bedded verge.

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

FUNCTIONAL REQUIREMENTS

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

I n s u l a t i o n. Low Energy Low Carbon Buildings

ROOFING. Introduction

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

PANELIZED HOME INSTALLATION GUIDELINE

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

CHAPTER 5 ASPHALT-SHINGLE ROOFING

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Frequently Asked Questions LP SmartSide Siding, Trim, and Soffit

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

Building Regulations for the Conservation of Fuel and Power

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

When considering Roof drainage design the following should be taken into account:

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Roof Slate. Westerland fi bre cement slate with dressed edge and textured surface. Complementary fibre cement ridge profiles also available!

REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

STANDING SEAM SHEET METAL ROOFING

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Transcription:

Uniclass L5216 CI/SfB (47) Ni May 2012 Shingle Installation / Fixing Specification John Brash offers one of the widest ranges of Cedar Shingles in Europe. Western Red Cedar Shingles These are taper sawn and have a relatively smooth face and back. Three lengths are generally available: 400mm ( XXXXX ), 450mm ( Perfections ) and 600mm ( Royals ). The 400mm Shingle is most often used in the UK and we hold significant stocks, along with smaller quantities of 600mm Shingles. John Brash only recommends the use of the premier No 1 Grade Blue Label Western Red Cedar Shingle in the standard XXXXX size (the lower grade Red and Black labels contain flat grain and sapwood that makes them unsuitable for premium roofing applications, often curling and with reduced longevity). Cedar Shingles can be laid in straight lines giving a clean regular appearance to the roof or wall, or with random butts giving a much more irregular aspect. Shape and Dimension Cedar Shingles are supplied in random widths varying between 75mm and 350mm. Their thickness tapers from approximately 10mm at the tail or butt edge to 3mm at the head. Cedar Shingles are supplied by the bundle ready to apply, either untreated, or with a timber preservative or fire retardant treatment. Underlay The use of underlay is not generally recommended in normal conditions for cold roofs. However, if one is to be used, the vapour permeable type to Annex A of BS 5534:2003+A1:2010 is recommended. Battens Should be strong and stiff enough to withstand the proposed loading and to provide adequate fixing and alignment. They should comply with BS 5534:2003+A1:2010. The minimum size recommended is 25mm x 38mm. John Brash recommends the use of JB-RED factory graded battens. Nails For maximum life, fixing should be made with 2 no. 31mm x 1.8mm silicon bronze annular ring nails or JB ShingleFix S16x38mm Stainless Steel Staples. Fire Some building regulations impose certain restrictions concerning possible fire risk and may require a fire retardant treatment, for example, FRT exterior which achieves the following performance - Euroclass B to BS EN 13501-1 (transposes to Class 0) Euroclass C to BS EN 13501-1 (transposes to Class 1) AAP60 rating BS 476: Part 3:2004 external Fire exposure of Roofs Shingles that are treated with a preservative have a CB rating. Preservation Cedar Shingles which are treated by John Brash to a specially designed cycle and formulation, carry a 40 year treatment guarantee against all forms of wood rotting fungi and insect attack in compliance with BS 8417:2011.

Conditioning John Brash recommend that all timber handled on site is managed as per BS 8000-5 and 6:1990 Workmanship on Building Sites. Fixing Guidelines The corrosive nature of WRC extractives requires the use of corrosion-resistant nails or fixings particularly in applications where the timber may get wet. Iron and copper nails rapidly decompose and deteriorate, leaving holes in the timber where the nails used to be after only 1-2 years, the timber may also stain. Where there are lead or other metal flashings care should be taken to avoid contact between the cedar and the metal. It is recommended that bituminous paint is applied as an effective barrier or GRP or other inert valleys or flashings are used. When used as vertical cladding; to prevent cladding coming into direct contact with porous or wetted surfaces John Brash recommend use of either a damp proof membrane or flashing or leaving a sufficient gap. In all cases a gap of 150mm - 200mm should be left below the bottom of the cladding and ground level. The Cedar should always be kept clear of any flashings below, by at least 10mm. The top edges should also be well protected. Projecting roofs and overhangs - these provide protection to cladding and joinery products during service and result in the product being only partly exposed to the elements. This can result in uneven appearance. Care must be taken with Cedar as it has a high tannin content; any run off water may cause a build up of a brown coating on the surface of any metal detailing or flashings. Consideration must be given at the design stage to ensure water is drained away to the outside of the wall. These can be removed using Oxalic acid. Oxalic-Acid Based Products - will remove extractives bleed and iron stains but are ineffective against mildew. After application of these products the timber should be thoroughly rinsed with clean water and completely dried before re-coating. Note the manufacturer s health & safety instructions when using this product. Important: Do not use wire brushes or wire wool for surface cleaning or preparation. See the TRADA External Timber Cladding Guide for full details. Waste Disposal WRC should be treated as softwood for on site disposal, and can be disposed of with other site softwood waste. It is suggested that recycling opportunities are explored with a responsible waste management company.

Frost Cedar Shingles are resistant to frost. Thermal Shingles & Shakes offer a high degree of thermal insulation with a value of K=0.1067 W/mºC. Roll Vent Roll Vent is relatively new to the UK but has been available in the USA for many years. It is used where both ridge and eave ventilation is required. Roll Vent complies with the requirements in the USA (CABO, BOCA, SBCCi and iicbo, FhA and US department of housing and development) with independent certification. This product gives a nett free area of 38,100mm 2 per m (18 sq. inches per linear foot) and should be installed in a balanced system. Full technical details are available on request. Roll Vent is simple to install. Extra wide ridge units should be used with this product. Estimating Coverage Shingles can be applied at a variety of gauges depending on their length and application. There are 3 main applications; 2 for roofing dependant on the pitch and 1 for vertical cladding. Nails For maximum life fixing should be made with 2 no. 31mm x 1.8mm silicon bronze or stainless steel annular ring nails per shingle. As a guide approximately 0.9kg of nails are required to fix four bundles of shingles. N.B. These are exact areas and do not allow for cutting and wastage. For simple roofs allow approximately 5% but for complex roofs with significant amounts of cutting this can be up to 20%. In addition for all cases allow extra for the following: i. Double Starter Course - 1 bundle for every 18 lin.m ii. Valleys - 1 bundle for every 7.5 lin.m. iii. Hips & Ridges* - 1 bundle for every 7.5 lin.m (traditional method) * Pre-formed Cedar Hip and Ridge units are now available from John Brash. For large projects John Brash recommend the use of JB ShingleFix S16x38mm Stainless Steel Staples. As a guide approximately 1000 staples are required to fix 4 bundles of shingles. Type Vertical 90-22 Degrees 22-14 Degrees XXXXX (400mm) Gauge - 190 mm 125 mm 95 mm Coverage - 3.47 m 2 2.28 m 2 1.73 m 2 Battens 25 x 38-5.3m per m 2 8.0m per m 2 10.5m per m 2 Royals (600mm) Gauge - 290 mm 190 mm 140 mm Coverage - 3.53 m 2 2.31 m 2 1.7 m 2 Battens 25 x 38-3.5m per m 2 5.3m per m 2 7.2m per m 2 Hip & Ridge N/A 4.5m 3.4m Fixing Coverage 95mm 125mm 190mm JB ShingleFix Staples - 1 Box (3000) 21.5m 2 28.5m 2 43.5m 2 Silicon Bronze Nails - 1KG 1.9m 2 2.5m 2 3.9m 2

Fixing Method Fixing Specification Cold Roofs The shingles should be fixed at the appropriate gauge directly onto roofing battens. A double course of shingles should be used as a starter course at the eave. The shingles should project at least 38mm beyond the eave protection or if a gutter is used at least to the centre line of the gutter. They should extend 38mm over the verge or gable moulding/barge board. Shingles are usually laid in straight lines but this application may be varied to produce different patterns i.e. staggered butts, double or shadow coursing. Thatch weave or ocean wave. The maximum gauge should never be exceeded. Shingles can accommodate changes of roof pitch and curved roofs. The shingles shall be spaced 6mm apart and be nailed or stapled twice, the nails/staples should be fixed 19mm in from the edge and 38mm above the butt of the course above. Joints in any one course should have a side lap of not less than 38mm from the joint in adjacent courses and in any 3 courses no 2 joints should align. Battens should be strong and stiff enough to withstand the proposed loading and provide adequate fixing and alignment. They should comply to BS 5534:2003+A1 2010. John Brash recommend JB-RED factory graded battens, 25x38. Traditionally for cold roof no underlays are required, however for most situations a vapour permeable underlay is recommended to Annex A of BS 5534:2003+A1:2010. For low pitch roofs of below 22 degrees a water impermeable, vapour permeable, underlay should be used, as there is a possibility of water penetration at very low pitches. Code 4/5 lead valley flashing edges dressed over tilt fillets - all in accordance with LSA (Lead Sheet Association) recommendations. Underlay to be taken over valley flashing Layboards fitted between rafters to support valley flashing Order of applying Shingles at valley 1. Stop course line here. 2. Place pre-cut piece so that cut angle is positioned chalk line with tip on course line 3. Select a Shingle of the required width to complete the course. Gaps between adjacent course not to align 6mm gap left between each shingle Adjacent course to be offset by 38mm Tilt fillets to be fixed to each side of layboard Cut the shingles to meet at the ridge. Then overlay with a ridge cap Vapour permeable underlay laid taught over tops of rafters Ends of battens to be fixed to layboards Batten Gauge: Roof 14-22 Roof 22 + = 95mm = 125mm 25mm x 38mm battens Paint the lead with a bitumen paint where it is likely to be in contact with the shingles Lead lining to valley to be dressed into gutter 38mm projection Double starter course 38mm overhang at the verge

Fixing Method Fixing Specification Cold Roofs (continued...) Shingle Fixing Details Exposure / Gauge Nails or staples should be 19mm in from the edge of the shingle and 38mm above the butts of the course above 38mm gap to be left on adjacent courses Alternative courses should not align Hips & Ridges may be formed on site by hand or alternatively a pre-formed hip & ridge capping may be used. A strip of roofing felt should be used beneath each capping piece. Roof Ridge Without Ventilation Pre-manufactured cedar ridge cap. Install per manufacturers instructions. OR Ridge cap manufactured on site using 125mm and 150mm shingles. Each shingle is chamfered and fixed with an alternate overlap Alternate left and right shingle ridge caps BS 747 Type 1 Shingles to roofs at 22 and above laid to give an exposure of 125mm. Fix with 2N 31mm x 1.8mm silicon bronze, stainless steel annual ring nails or staples 19mm in from the edge and 38mm up from the butt line of the course above 25mm x 38mm minimum size treated battens to comply with BS 5534:2003+A1:2010 at 125mm gauge Underlay Hip Detail Shingles to roofs at 22 and above laid to give an exposure of 125mm. Fix with 2N 311mm x 1.8mm silicon bronze or stainless steel annular ring nails 19mm in from the edge and 38mm up from the butt line of the course above Water vapour permeable underlay Alternate overlaps Intersecting roof surfaces at hips to be capped to ensure a weathertight joint. Either site made or factory assembled hip units may be used but both types must have alternate overlaps andconcealed nailing. Weather exposure should be the same as for the body of the roof. Nails must be longer than those used for the body of the roof and of all sufficient length to penetrate 19mm into the battens Strip of felt on edge over ridge and hip covered by ridge cappings Shingles to project over fascia 38mm Fascia board 25mm x 38mm minimum size treated battens to comply with BS5534:2003+A1:2010 at 125mm gauge

Fixing Method Fixing Specification Cold Roofs (continued...) Ventilation should be at eave level and a Roll Vent ridge ventilator is available from John Brash & Co Ltd. Roof Ridge With Ventilation Extra wide Pre-manufactured cedar ridge cap. Install per manufacturers instructions Ridge cap manufactured on site using 190mm and 200mm shingles. Each shingle is chamfered and fixed with an alternate overlap Alternate left and right shingle ridge caps BS 747 Type 1 Roll vent ventilation system 6mm min Shingles to roofs at 22 and above laid to give an exposure of 125mm. Fix with 2N 31mm x 1.8mm silicon bronze, stainless steel annual ring nails or staples 19mm in from the edge and 38mm up from the butt line of the course above 25mm x 38mm minimum size treated battens to comply with BS 5534:2003+A1:2010 at 125mm gauge Nails must penetrate roof deck, 12mm minimum Underlay Valleys should be code 5 lead or as specified and should be at least 375mm in width and should be coated with patination oil or bituminous paint where contact is made with the shingles. The shingles should lap the lead by not less than 178mm on each side. Flashings shall be in accordance with good building practice and should be coated with patination oil or bituminous paint where contact is made with the shingles. Fixing Method Fixing Specification Warm Roofs Shingles can be used over a variety of roof types. boarded roofs, metal decks and warm roof construction. Care should be taken to follow current building regulations and individual specifications can be determined in conjunction with the insulation manufacturer. Typically counter battens are used to create a vented space over the insulation. Again care is needed on low pitched roofs, below 22 deg, where a water impermeable membrane must be used as there is the possibility that water may penetrate through the roof covering. Warm Roof Construction Eaves with Solid Insulation Water vapour perpeable underlay Shingles to roofs at 22 and above laid to give an exposure of 125mm. Fix with 2N 31mm x 1.8m silicon bronze, stainless steel annual ring nails or staples 19mm in from the edge and 38mm up from the butt line of the course above Insulation between trusses Top of truss 25mm x 38mm minimum size treated battens to comply with BS5534:2003 at 125mm gauge fixed to 50mm x 50mm treated counter battens fixed through overlay to rafter of truss 125 125 135 Insect guard First course doubled Shingles to project over fascia 38mm Vapour permeable underlay Duplex grade plaster board ceiling lining Gutter Polythene sheathed mineral wool cavity closer Soffit board Section of extruded polystyrene insulation cut to fit between trusses at eaves

Typical Roof Details Swept / Ball Eave For excessive sweep the shingles may be bent Convex Roof Juncture to Vertical Cladding Juncture Double or triple starter course Narrow shingles applied horizontally or wood moulding Sheathing Concave Roof Juncture Concave Roof Juncture Double starter course Two last courses over flashing Double starter course Metal flashing Monopitch Roof Juncture Last course over flashing Metal Flashing Ridge cap: Alternate overlap with double starter course Fixing Method Fixing Specification Vertical Shingles are applied in the same manner as for roofing except there need only be a two ply (2 thicknesses of shingle) rather than 3 for roofing. Shingles are nailed directly onto battens that can be fixed to masonry or studs. A breather paper is used behind the battens. Double coursing can give attractive shadow lines. Here shingles are applied at an extended gauge but with two courses together. Staggered butts can also be effective. Outside corners are laced with an alternate overlap and inside mitred with a flashing behind.