For more summarised information please check our website sub section SABS Codes.



Similar documents
SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

SURGE PROTECTIVE DEVICES

Class I surge protection with sparkover gaps

Surge Protection Main Catalogue 2014/ New Products.

wietap wietap Overvoltage Protection Tensions running high

Surge protection for emergency alarm systems

DEHNshield Application-optimised multipole combined lightning current and surge arrester

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

CATALOGUE SURGE PROTECTION LOW VOLTAGE

Surge Protection for Photovoltaic Systems

Unified requirements for systems with voltages above 1 kv up to 15 kv

Telecommunication Line Protectors

Power surges can also be generated by equipment in your facility such as:

Electrical safety requirements in DC distribution systems

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

How To Understand The Electrical Power Supply Of A Power Supply System

DEHN stops Surges. More Information. Safety for your property. DEHN + SÖHNE DEHN + SÖHNE. Lightning Protection Surge Protection Safety Equipment

White paper. ABB solutions for switching and protection of low speed wind turbines

This is a preview - click here to buy the full publication TECHNICAL REPORT

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Technical guide Protection against earth faults with Residual Current Devices

Arc Terminator Active Arc-Resistant Switchgear

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

How To Make A Power Meter Safe

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Distribution Design Manual

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

INTERNATIONAL STANDARD

Lightning Arresters P KVA P KVA. Description & Installation

Guide to the electrical parameter classifications of IEC and IEC safety standards

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Fault location on power cables. Fault location on power cables

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

When power interruptions happen.

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Cahier technique no. 178

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Electrical safety and protection devices

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Power Quality for Information Technology System

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

DESCRIPTION DWG DESCRIPTION DWG

Circuit Electrical Testing

R.C.C.B. s two-pole LEXIC

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

How can a charging station for electric vehicles be set up simply and safely?

3. Cooling System Closed-loop Pure Water-cooling. Rated Voltage: 6 ~ 66kV. Rated Current: 4000A (phase current).

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Grounding & Bonding Why it is done And How to Install Properly

Rule Fast Track Analysis for National Life Insurance Co.

Surge Protection. Electrical Installations. Photovoltaic. Telecom. Data. Radiocommunication

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Intersection Preassembled 19-inch Rack

How to Prevent Power Surges: The Leading Cause of Serial Device Server Failures

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Application of Four-Pole Circuit Breakers within Data Centers

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

SHORT CIRCUIT CURRENT CALCULATION AND PREVENTION IN HIGH VOLTAGE POWER NETS

Residual Current Circuit Breaker

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

How To Choose A Transformer

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Motor Protection Voltage Unbalance and Single-Phasing

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Guide to the Selection & Use of Residual Current Devices

Transient and Lightning Protection for the Water Industries

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

1. Franklin Rod Performance 2. LEC/DAS Performance

Fundamentals of Power

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Electrical Contractors Association

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Technical Article MS-2443

Engineering Specification

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transcription:

A simple guide to selection of Lightning and Surge Protection Please note that this is a very simple summary and must be read in conjunction with the relevant code SANS 10142-1:2008 Edition 1.6 Annex L which refers specifically to surge arresters. At present it is not compulsory to install lightning and overvoltage protection but should you install surge arresters then it must be done in accordance with SANS 10142-1:2008 Annex L. For more summarised information please check our website www.surgetek.co.za sub section SABS Codes. The selection of surge arresters has become very confusing for the layman and gets even worse when trying to ensure that you select the correct surge and lightning protection for the application. To make it easy here is a simple selection guide. There are 3 x main categories of lightning surge arresters. Class 1 (10/350) lightning current arresters, which can withstand direct lightning (must be used with Class 2) Class 2 (8/20) surge arresters, to protect against induces surge currents Class 3 - (8/20) surge arresters, to protect against induces surge currents 1.0 Lightning Current Arresters Class 1 (10/350) Typical surge handling ability must be 12.5kA (10/350) per phase. Whenever a building has external lightning protection such as a mast, or conductors on the building, Class 1 lightning current arresters are required. DEHNbloc M (Phase), DEHNgap M (Neutral) These units are designed to withstand direct lightning surge currents and are very robust devises, but on their own cannot clamp the voltage to low enough levels to protect sensitive electronics. Thus Class 1 lightning current arresters must always be used in conjunction with Class 2 surge arresters (8/20). Should you use DEHNbloc M then there is no need for decoupling between Class 1 and Class 2 arresters. (This is not true for all other makes of surge arresters). If you do not use a Class 2 surge arrester in conjunction with the Class 1 lightning current arresters, surge up to 3kV could enter the system and the surge arresters would not operate thus damaging sensitive electronics. BRANCH OFFICE: KWAZULU-NATAL: TEL. (031) 765-3397 FAX. (031) 765-5496 WEB SITE: www.surgetek.co.za Directors: P. Narismulu, A. Nydoo

Page 2 2.0 Surge Arresters Class 2 (8/20) DEHNguard 275 In all cases you must install a minimum of a Class 2 surge arrester in the main electrical distribution board. The SANS 10142-1:2008 requires that these surge arresters must withstand a nominal surge current of 5kA and a peak surge current of 10kA. Experience has shown this to be inadequate. The IEC requires a nominal surge current rating of 10kA and 25kA peak surge current. All surge arresters (except for gapped type) must have a disconnection mechanism with a visual indication showing end of life, this can be mechanical flag or a light. 3.0 Combination Arresters Class 1 & 2 3.1 DEHNventil TT (25/100 ka) (10/350) To overcome the problem of co-ordination of Class 1 and Class 2 arresters we have developed a combined surge arrester which eliminates this problem. The DEHNventil M TT makes use of pre-triggering technology which is a combination Class 1 and Class 2 arrester in 1 x packaging. The main advantage of this unit is that it can be used in all applications and offers complete protection and co-ordination with Class 3 arresters that may be installed within the equipment. In addition it has pluggable modules that can be replaced without the need to disconnect the power. A further advantage of this combination is that it halves the clamping voltage Phase to Neutral when compared to the standard method of installing surge arresters from each Phase and Neutral to Earth and it can be used on all types of wiring applications, TNS, TN-C-S and TT earthing systems. This means you can install the DEHNventil M TT in a container electrical distribution board and have complete protection These units can take a direct strike and limit the voltage to less than 1,5kV as required by SANS 10142-1:2008 Table L.1.2. 3.2 DEHNguard M TT (40kA) (8/20) In cases where a very high level of protection is required but Class 1 is not a requirement, we recommend that a DEHNguard M TT be installed. This unit consists of 3 x 40kA Class 2 surge arresters from Phase to Neutral as well as 1 x 12,5kA Class 1 arrester Neutral to Earth. The main advantage of this combination is that it halves the clamping voltage Phase to Neutral when compared to the standard method of installing surge arresters from each Phase and Neutral to Earth and it can be used on all types of wiring applications, TNS, TN-C-S and TT earthing systems. In addition it has pluggable modules that can be replaced without the need to disconnect the power.

Page 3 4.0 Surge Arresters Class 3 (8/20) DEHNrail M 255V When using Class 3 surge arresters there must always be Class 2 surge arresters installed upstream to ensure that the units will not be overstressed. These units are typically 5kA (8/20) devises and are used to dissipate any surges that may be induced between the electrical distribution board and the equipment. Class 3 surge arresters without internal disconnecting mechanisms may only be used in circuits that are supervised by earth leakage devices. 5.0 Pre-Fusing of Surge Arresters When surge arresters are installed in systems with a main breaker larger than 250 Amps or 5kA fault current, they should be pre-fused to prevent the units creating a danger when subjected to high fault currents. Due to the fact that the surge arresters are connected directly to the incoming supply and thus have no means of extinguishing the arc should they become conductive under electrical fault conditions. For Class 1 lightning current arresters we recommend that 315A fuses and for Class 2 surge arresters we recommend that 125A fuses, of the same fault current rating or larger than that of the board, be installed in series with the surge arresters to disconnect the surge arresters under fault conditions. These fuses have nothing to do with the normal operation of the surge arresters but is purely for electrical safety. 6.0 Installation mode of SPDs Connection type 2 as per SANS Figure L.1.3 SANS 10142:2008 section L.1.3.5.5 b) states for connection type 2, the nominal discharge current (In) for the SPD connected between the neutral conductor and the PE shall be not less than 20 ka (8/20) for three-phase systems and 10 ka (8/20) for single-phase systems (see figure L.1.3).

Page 4

Page 5