Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Similar documents
Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Thermal processing for drying, heating and cooling

Chapter 3.4: HVAC & Refrigeration System

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

dryon Processing Technology Drying / cooling in outstanding quality we process the future

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Improving Data Center Energy Efficiency Through Environmental Optimization

Detailed Design Review. P15611: Digital Microfluidics Packaging

EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT

CoolTeg Plus Chilled Water (CW) version: AC-TCW

We have been working in an ideal climate for thirty years.

Wet Bulb Temperature and Its Impact on Building Performance

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Experimental Evaluation Of The Frost Formation

EuroSun 1998 A NEW CONCEPT FOR SOLAR THERMAL DESALINATION Results of In-Situ Measurements

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

DRYPOINT RA REFRIGERATION DRYER RANGE

How To Run A Data Center Efficiently

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager

Maintenance for Energy Efficiency

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Automated Commissioning for Energy (ACE) Platform for Large Retail Property. Overview

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

Data Center Environments

Energy savings in commercial refrigeration. Low pressure control

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

HVAC Systems: Overview

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

A single solution to the four challenges facing your urea prilling plant

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

heatersteam precision and reliability for all types of applications

VACUUM REFRIGERATION SYSTEMS

THEORETICAL ANALYSIS OF THE PERFORMANCE OF DUAL PRESSURE CONDENSER IN A THERMAL POWER PLANT

ThermoSorb Desiccant Dryers

Dehumidifier D 850E. - Instruction manual version 02

The Single Absorption Scrubbing Sulfuric Acid Process

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

University of St Andrews. Energy Efficient Data Centre Cooling

In-Line Air Separators

HEAVY DUTY STORAGE GAS

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle


Solar Thermal Energy Storage Technologies

Refrigeration Compressed Air Dryer Buran Ultrapulse

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Chilled Water HVAC Systems

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

UDSA - UDSBD unit heater

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Sound pr. (db(a)) Phone: Pressure hpa Fax: Capacity kw

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Description of Thermal Oxidizers

Drives and motors. A guide to using variable-speed drives and motors in retail environments

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

Haldor Topsøe Catalysing Your Business

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

Energy Efficiency HOSPITALITY.

Session 2: Hot Water Supply

Year project completed or estimated year of completion: October 2014

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

System solution for data centres

Urea DAP MOP. November 08 November 07 April 08 - November 08 April 07 - November 07

Improving Data Center Efficiency with Rack or Row Cooling Devices:

I don t want to move to the Arctic - a HPC Data Center Take on PUE and Energy Efficiency

Refrigerated Air Dryers. Catalogue

C. starting positive displacement pumps with the discharge valve closed.

The CEETHERM Data Center Laboratory

Direct steam injection humidifiers

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Analysis of data centre cooling energy efficiency

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Enclosed Football Stadium Design History and Lessons Learned

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Appendix C. Minimum Equipment Efficiency Standards

Environmental Data Center Management and Monitoring

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Hines Property Management, NYC

HEAT TRANSFER ANALYSIS OF COLD STORAGE

Blade Server & Data Room Cooling Specialists

Agenda. Who we are What we do How we serve the BPO Industry

Thermochemical Storage for Air-Conditioning using Open Cycle Liquid Desiccant Technology

ThermoStar Refrigeration Air Dryers

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Second Place: Industrial Facilities or Processes, New

Completion of SCR System for Ninghai Power Plant Unit 4 in China

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Transcription:

Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance 6 th to 10 th of May 2013. AGADIR MOROCO Neville Jordison Solex Thermal Science Inc. Canada

A Brief History o o o o Indirect Heat Exchanger introduced to the fertilizer industry approximately 25 years ago Today more than 100 coolers installed in fertilizer plants round the world Equipment operating successfully in every type of fertilizer - Urea (prills & granules), AN, CAN, LDAN, NPK, MAP, DAP, AS Company History 1990 - creation of Bulkflow Heat Exchangers a technology division within Cominco Engineering Services Ltd 1999 - BULKFLOW TECHNOLOGIES is incorporated with headquarters in Calgary, Canada 2008 - Rebranded as Solex Thermal Science Inc to enhance profile as a world leader in the science of heating and cooling bulk solids

Advantages compared to Air Cooling (Rotary or Fluid Bed) o o o o Low energy consumption No air usage eliminates chillers, fans ducts and scrubber Compact design Lower installed capital cost

Principle of Operation Combines the science of mass flow with indirect heat transfer Product flows slowly by gravity between water cooled plates Product flows in uniform velocity mass flow Water flows counter-current inside plates Heat Exchange by conduction

The Secret to Long Term Operating Performance What causes Caking? HYGROSCOPIC PRODUCT HUMIDITY IN VOID SPACE WATER COOLED PLATES CONDENSATION CAKING ON PLATES

The Secret to Long Term Operating Performance Preventing the Caking Mechanism PURGE AIR ADD PURGE AIR TO LOWER DEWPOINT CORRECT WATER TEMP PROFILE ELIMINATE CONDENSATION NO CAKING

The Secret to Long Term Operating Performance The CRH Curve

The Secret to Long Term Operating Performance Thermal Modelling Process Input Conditions

The Secret to Long Term Operating Performance Thermal Modelling Output Temperature Profile

The Secret to Long Term Operating Performance Ensuring Water Temperature is above the Dew Point Water temperature must be to right of dewpoint line to prevent condensation mechanism

The Secret to Long Term Operating Performance Complete System o Tempered Water Module to provide controlled cooling water temperatures o Purge air system controlled flowrate and dewpoint o Instrumentation and Control System

Pilot Testing at OCP Jorf Lasfar o DAP o Product Inlet Temperature 65 75 C o Maintain discharge temperature below 50 C o Demonstrate long term run capability without caking

Pilot Testing at OCP Jorf Lasfar PRODUCT IN Test Set-up o Double Bank Exchanger o Controlled Cooling Water Temperatures PURGE AIR o Purge Air system o Demonstrate long term run capability without caking PRODUCT OUT

Pilot Testing at OCP Jorf Lasfar Results Steady-State Averages for each run: Product T in T out Rate TOP BANK T in Water BOTTOM BANK T out Purge Air Run 1 (July 17) 66-74 C 44-58 C 180 kg/h 65-72 C 43-58 C yes Run 2 (July 18) 71.5-74 C 45-46 C 230-370 kg/h 61 C 44-45 C yes Run 3 (July 20) 63-72 C 39-44 C 200 kg/h 58.5-60 C 40-45 C yes

Pilot Testing at OCP Jorf Lasfar Plate Banks checked after each run o Removable Plexiglas plate o Plate surfaces stayed clean throughout testing

Typical DAP Cooler o Product Flowrate: 100 t/h o Product Size: 1 4 mm o Product Temperature in: 85C A = 10740 B = 1650 C = 1580 E = 150 F = 1800 G = 2470 J = 1390 o Required Product Temp. out: < 50C o Cooling Water: Cooling Tower at 28C o Purge Air: Required

Typical DAP Cooler o Water Temperature Control Module o Primary water supply can be cooling tower or sea water use 254SMO or titanium plate heat exchanger o Purge Air Supply o Unit typically installed immediately following the screens

Recent Fertilizer Projects Company Location Product Capacity Yara Fertilizers Porsgrun, Norway NPK 210 t/h Gemlik Gubre Gemlik, Turkey Amm. Nitrate 80 t/h National Fertilizers Jagdishpur, India Urea Prills 2 x 155 t/h Zuari Fertilizers and Chem. Zuarinagar, India NPK 75 t/h JPMC Jordan DAP 2 x 70 t/h

Large urea prill cooler during installation in India

Long Term Operating Performance This campaign the CAN Plant started up on 5 th of June and until now The Solex Cooler hasn t needed cleaning yet and is operating perfectly. Quote from Alp Bulent GULES Gemlik Gubre Sanayii A.S. Sept 26 th 2010 Thank you for your attention