Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in the UK H. Kuhnke Ltd Unit 6 Focus 303 Focus Way, Walworth Business Park Andover Hampshire SP10 NY United Kingdom Tel: +44 (0)164 364194 Fax: +44 (0)164 36991 Email: sales@kuhnke.co.uk Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.
Uc: 10 Standard type,, Mechanically guided contacts for security controls in accordance with DIN VDE 0113 part 1 High switching capability through bridge contacts High contact making reliability through twin contacts Version for printed circuit + S 10A310 4VDC Uc: 07 07 1A 10VAC 10A310 4VDC Ith=16A Ui=380Vac (C) 380VAC,kW AC3 Ith=16A Ui=380Vac (C) 380VAC,kW AC3 1A 10VAC Order Code Order code 10 A 400 4 V DC Type of relay 10 Model A Plug-in type for socket 6.3 mm or x B.8 resp. in accordance with DIN 4647 G For printed circuit G Contact arrangement 400 4 N/O 400 310 3 N/O, 1 N/C 310 0 N/O, N/C 0 Contact material, type of contact - Hard silver (no code letter) - C AgCdO (model A only) C F Twin contacts hard silver F Nominal operation coil voltage (see coil data) 4 V 4 V Coil current type DC Direct current DC AC Extensions Alternating current 0 / 60 Hz with bridge rectifier - None (no code letter) - B H Quick-action fastening for rail EN00-3 x 7. Manual override (combination B and H not possible) S Screw mounting S A AC B H Kuhnke 38 Relay Catalogue
Contact Data Contact arrangement 10 4 N/O 3 N/O and 1 N/C N/O and N/C Contact arrangement Single contact Control contact 07 1A 10VAC 10A310 4VDC Ith=16A Ui=380Vac (C) 380VAC,kW AC3 Type of contact Bridge contact Bridge contact as twin contact Contact material Hard silver AgCdO Hard silver Nominal contact current 16 A 10 A Inrush current 60 A 0 A Nominal contact voltage 400 VAC / DC Max. switching capacity (resistive) 6000 V0 VA Min. switching capacity 00 ma / 60 VDC 0 ma / 0 VDC Switching capacity AC1 AC3 DC1 AC4 6 kw / 400 V. kw / 400 V 3 kw / 400 V 0.7 kw / 400 V 100 W (for security circuit in accordance with professional association) not suitable Dimensions, Connection Diagram(s) 6. 0 39 6 6. 7. 0 39 6. 4 11 9. 1 0 4. 39 0 60 10A... B 10G... H 10A... S A 14 4 34 44 A 14 4 34 4 A 14 4 3 4 A1 13 3 33 43 A1 13 3 33 41 A1 13 3 31 41 10... 400 10... 310 10... 0 Grid. mm Viewed on connector pins Drillhole diameter.1 mm Kuhnke 39 Relay Catalogue
07 1A 10VAC 10A310 4VDC Ith=16A Ui=380Vac (C) 380VAC,kW AC3 General Data Pull-in-time approx. ms Drop-out time Bounce time Mechanical service life Test voltage Coil - contact Contact - contact Insulation group VDE 0110b/.79 Short-circuit protection VDE 0660 part 00 10 approx. 8 ms DC, approx. 3 ms AC approx. ms > 10 x switching cycles 00 VAC 00 VAC C380 1000 A Ambient temperature - C to +60 C Vibration resistance (30-100 Hz) Weight Operating range Pull-in DC Class (0.8-1.1 U N ) > 4 g approx. 60 g after coil excitation with U N at T U 3 C AC, 0 / 60 Hz Class (0.8-1.1 U N ) Drop-out > 0.0 U N > 0.1 U N Coil Data Coil voltage DC * *Other voltages on request 10 Pull-in power approx. 1.3 W Nom. operation coil power approx. 3.6 W Coil voltage AC * 10 Pull-in power approx. 1. VA Nom. operation coil power approx 4. VA. Nominal voltage (V) Nom. resistance (Ω) Nominal current (ma) Nominal voltage (V) Nom. resistance (Ω) Nominal current (ma) 1 41 90 1 3 340 4 11 160 4 10 180 40 473 8 4 390 97 60 968 6 60 780 69 110 3370 33 110 37 0 13700 16 30 13400 1 Kuhnke 40 Relay Catalogue
07 1A 10VAC 10A310 4VDC Ith=16A Ui=380Vac (C) 380VAC,kW AC3 Electrical Service Life Electrical Service Life AC 1 90 % operating 400 V 30 V AC 1 AC 1 10 10 0.1 0. 0. 1 10 Resistance switching capacity in kw Single contacts 0.1 0. 0. 1 10 Resistance switching capacity in kw Control contacts Electrical Service Life AC 3 90 % operating 400 V 30 V AC 3 AC 3 10 M 3~ 0.1 0. 0. 1 10 Motor switching capacity in kw 10 M 3~ 0.1 0. 0. 1 10 Motor switching capacity in kw Single contacts Control contacts Switching Capability 90 % operating 0 0 Switching current in A 10 1 Closing contact Switching current in A 10 1 Opening contact 0. 0. 0. Closing contact 0.1 0 0 40 60 80 100 10 140 160 180 00 0 40 60 80 300 Switch-off voltage in V Single contact closing contact 0. Opening contact 0.1 0 0 40 60 80 100 10 140 160 180 00 0 40 60 80 300 Switch-off voltage in V Single contact opening contact Kuhnke 41 Relay Catalogue
Order Specifications for Accessories Relay 10 Socket for scew connection with quick-action fastening Z30.0 Socket Z30.0 71 7. 07 1A 10VAC 10A310 4VDC Ith=16A Ui=380Vac (C) 380VAC,kW AC3 64 Socket Z30.0 Terminal capacity solid conductor flexible conductor with ferrule Terminal designation x. mm x 1. mm in accordance with EN000 Mounting Rail EN00-3 x 7./1 Screw terminals Torque in accordance with DIN EN 60999 Nominal current Insulation group VDE 0110b/.79 Weight Retaining clip Head screws metric M4 1. Nm 16 A C380 110 g enclosed retaining clips Kuhnke 4 Relay Catalogue