600 A 15 kv class BT-TAP deadbreak connector

Similar documents
25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

ELASTIMOLD CATALOG SP2. Issue Date: 03/2003

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Type MOST oil switch. Technical Data Contents. Effective October 2013 Supersedes March 2000

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Product Selection Guide

How To Test A Power Cable For Power And Safety

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Section kv Power Cables

16300 MEDIUM VOLTAGE DISTRIBUTION

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Medium Voltage Terminations, 5 kv 46 kv

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

100% EMI Emission Containment

Lightning Arresters P KVA P KVA. Description & Installation

Transformer Bushings for GIS

Medium Voltage Joints & Terminations

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

MEDIUM VOLTAGE DISTRIBUTION

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Secondary Unit Substations

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Equipment. Metering. Metering Equipment 1. Contents

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

a Nexans company Catalogue 2014

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint

ENGINEERING COMMITTEE

Instrumentation Cable Power Cable Assembly Solutions...32

a Nexans company Catalogue 2013

CABLE ACCESSORIES kv

EDITION 2012 CABLE SYSTEMS

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

5.2. Overview. The better method to install solderless compression connectors on power cable

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

Type K current limiting fuse canister Technical information and installation guide

TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No V.

TRANSFORMER DICTIONARY

Hyperlinks are Inactive

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

I NTERFACE CABLE ADAPTER MODULE

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

Step 1. Item 6. Item 1

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits, 7620-S, 7680-S and 7690-S Series 5, 8, 15, 25/28 and 35 kv

Cables. Accessories. For Force, Torque and Strain Sensors

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Power Cable Splicing & Terminating. edited by Robert Goodman and William Osborn

RAY-MAX Integrated Solar Power Strip

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Fault location on power cables. Fault location on power cables

Medium Voltage Electrical Distribution

Current Transformers

EVALUATION OF ON-SITE DIELECTRIC RESPONSE METHODS FOR NON- DESTRUCTIVE TESTING OF WATER TREED MV XLPE CABLES

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

3M Scotchcast Mine and Portable Cable Splice Kit

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Standards Affecting a Premise T-1 Installation

Industrial Cable Solutions for Variable Frequency Drives

Exclude all sales to foreign countries and all sales or transfers to other divisions or plants of your company. Survey Form 3.3.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Distribution Transformers

Bolted contact switches. Pringle switches

W1 Connector W1 Adapter W1 Termination

Waterproof Connectors for Outdoor Use

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Distribution Dry Type Transformers

Specification for Cable Accessories, Termination and Jointing Materials for Underground Electrical Power Cables for Nominal System Voltage Up to 33kV

CONDUCTOR SHORT-CIRCUIT PROTECTION

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Connecting the Channel A

Directory chapter 04

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

Why Buy HVI VLF Products?

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Owner's/Installation Manual

Transcription:

Deadbreak Connectors Catalog Data CA650002EN Supersedes January 2015 600 A 15 kv class BT-TAP deadbreak connector COOPER POWER SERIES General Eaton terminates high-voltage underground cable to transformers, switches, switchgear and other apparatus with its Cooper Power series 600 A 15 kv Class BT-TAP deadbreak connector. It is designed for use with unthreaded connectors, to easily retrofit existing 600 A BOL-T installations or in new installations where a 200 A interface is required and where the system will not need to be frequently operated. If the system will be frequently operated to sectionalize or to achieve a visable break or ground, Eaton recommends its Cooper Power series T-OP II Connector System. (See catalog section CA650017EN.) The BT-TAP deadbreak connector is fully shielded, submersible and meets the requirements of IEEE Std 386-2006 standard Separable Insulated Connector Systems. The 200 A, three-phase rated loadbreak interface provides a means for obtaining a direct conductor test, visible ground and provides a convenient location for an Eaton's Cooper Power series M.O.V.E. arrester or grounding elbow. Eaton offers an optional capacitive test point similar to test points on its Cooper Power series 200 A elbow connectors. This allows use of Eaton's Cooper Power series Type TPR faulted circuit indicators, and provides a hotstick operable means of determining circuit condition when used with high impedance voltage sensing devices designed for test points. BT-TAP connectors are designed for use on solid dielectric cable (XLPE or EPR) with extruded semi-conductive shields and concentric neutral, with or without a jacket. Installation on jacketed concentric neutral cable may require additional sealing material. Cold shrinkable adapters are available for tape shield, linear corrugated, unishield, and drain wire cables for use with deadbreak connectors.

Catalog Data CA650002EN 600 A 15 kv class BT-TAP deadbreak connector 900 AMP rating The BT-TAP connector is rated for 900 A continuous when used with a coppertop compression connector and copper bushing or junction. If a 900 A rating is desired, specify a C as the 10th digit when determining your part number. See Step 3, page 4. Interchangeability Eaton conforms to the electrical, mechanical and dimensional requirements of IEEE Std 386-2006 standard with its Cooper Power series 600 A deadbreak connectors. The connectors can be used on any comparably rated bushing interface that also meets the requirements of this standard. In addition, all T-bodies, cable adapters, insulating plugs and compression connectors are designed to be interchangeable with those currently available from other major manufacturers that also certify their components to IEEE Std 386-2006 standard. Installation The T-body is assembled onto prepared cable with an unthreaded compression or shear bolt connector. The stud provided with the kit, is torqued onto a de-energized 600 A bushing. Using a T-WRENCH, the loadbreak reducing tap plug is threaded onto the stud drawing the entire assembly tight to the apparatus bushing. The assembly is then torqued to the apparatus bushing using a torque wrench. Refer to Service Information MN650004EN, 600 A 15 and 25 kv Class BT-TAP Connector System Installation Instructions for details. Production tests Tests conducted in accordance with IEEE Std 386-2006 standard: ac 60 Hz 1 Minute Withstand 34 kv Minimum Partial Discharge Extinction Voltage 11 kv Tests conducted in accordance with Eaton re quire ments: Physical Inspection Periodic Dissection Periodic X-ray Analysis Table 1. Voltage Ratings and Characteristics Description Standard Voltage Class 15 Maximum Rating Phase-to-Phase (loadbreak reducing tap plug only) 14.4 Maximum Rating Phase-to-Ground 8.3 ac 60 Hz 1 Minute Withstand 34 dc 15 Minute Withstand 53 BIL and Full Wave Crest 95 Minimum Partial Discharge Extinction Voltage 11 Voltage ratings and characteristics are in accordance with IEEE Std 386-2006 standard. Table 2. Current Ratings and Characteristics Description Amperes 600 A Interface Continuous 600 A rms (Aluminum) 900 A rms (Copper) 4 Hour Overload 900 A rms (Aluminum) 1,200 A rms (Copper) Short Time 25,000 A rms symmetrical for 0.17 s 10,000 A rms symmetrical for 4.0 s 200 A Interface* Continuous 200 A rms Switching 10 operations at 200 rms at 14.4 kv phase-to-phase Fault Closure 10,000 A rms symmetrical at 14.4 kv phase-to-phase for 0.17 s after 10 switching operations Short Time 10,000 A rms symmetrical for 0.17 s 3,500 A rms symmetrical for 3.0 s Current ratings and characteristics are in ac cor dance with IEEE Std 386-2006 standard. * System design and protection must recognize the ratings of 200 A interface. kv 2

600 A 15 kv class BT-TAP deadbreak connector Catalog Data CA650002EN BOL-T LOADBREAK REDUCING TAP PLUG BOL-T Loadbreak Reducing Tap Plug (BLRTP) is 200 A, three-phase loadbreak and three-phase fault close rated. It incorporates internal threads that mate with the stud in the apparatus bushing. T-BODY Molded T-body adapts to all cable sizes and provides a deadfront shielded connection. CONDUCTOR CONNECTOR (Compression Connector pictured) Compression connector is sized to ensure a cool running connector with maximum current transfer. Shear bolt connector description below. DRAIN WIRE TAB Molded into semi-conductive shield for the attachment of a drain wire to maintain deadfront safety LATCH INDICATOR RING CAPACITIVE TEST POINT Capacitive test point (optional) on molded T-body with snapon cap provides a place to mount Eaton's Cooper Power series TPR faulted circuit indicators. SEMI-CONDUCTING SHIELD Precision molded, peroxidecured, semi-conducting shield provides ground shield continuity and meets the requirements of IEEE Std 592-2007 standard. SEMI-CONDUCTING INSERT Molded peroxide-cured, semiconducting insert provides corona-free electrostatic shielding of the compression connector. EPDM INSULATION High-quality, peroxide-cured EPDM insulation is mixed and formulated in-house for complete control of rubber characteristics. CABLE ADAPTER Molded cable adapter, sized to fit cable insulation diameters from 0.640 inches to 1.965 inches (16.3 to 49.9 mm), provides stress relief for the terminated cable. BOL-T LOADBREAK REDUCING TAP PLUG (BLRTP) 200 A, three-phase loadbreak and three-phase fault close rated. Figure 1. Cutaway drawing illustrates design features. Optional features Protective cap 200 A insulated protective cap fits over loadbreak reducing tap plug for deadfront shielding. Capacitive test point Capacitive test point on molded T-body, with snap-on cap, provides a place to mount Eaton's Cooper Power series TPR faulted circuit indicators. Shear bolt connector (optional) Bolted cable lug is fitted with stepless bolts, which shear off when optimum contact force has been reached. Provides electrical continuity for copper and aluminum conductors while eliminating need for dies and compression tools. Figure 2. Shear bolt connector 3

Catalog Data CA650002EN 600 A 15 kv class BT-TAP deadbreak connector BT-TAP connector kit catalog numbering system Build the 12 digit catalog number for a 15 kv BT-TAP Kit by following the steps given below. The first 6 digits are always BTP615, only digits 7 through 12 need to be selected. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 B T P 6 1 5 Catalog Number Digits: 1, 2 & 3 = BTP, BT-TAP Connector System 4 = 6, 600 A System 5 & 6 = 15, 15 kv Class Bushing Interface Step 1 Select Digits 7 and 8 Cable Adapter Range Code Determine the cable s diameter over the electrical insulation as shown in Figure 3 (including tolerances). Then identify a cable range from Table 3 that covers the minimum and maximum insulation diameters. Select the correct CABLE RANGE CODE from Table 3. Table 3. Cable Diameter Range Inches mm Code 0.610-0.970 15.5-24.6 AB 0.750-1.080 19.1-27.4 CC 0.970-1.310 24.6-33.3 DD 1.090-1.470 27.7-37.3 EE 1.260-1.640 32.0-41.7 FF 1.360-1.710 34.5-43.4 GG 1.510-1.850 38.4-47.0 HH 1.700-1.970 43.2-50.0 JJ Step 3 Select Digit 11 Determine whether 600 A or 900 A Rating is required. Shear bolt is only available as 600 A Aluminum Connector. A = 600 A Rating (Aluminum Compression or Shear Bolt Connector, Aluminum Stud and Aluminum Reducing Tap Plug) C = 900 A Rating (Coppertop Compression Connector, Copper Stud and Copper Reducing Tap Plug) Step 4 Select Digit 12 Determine if a standard length or extended length stud is required. S = Standard Length L = Extended Length Step 5 Select Digit 13 (optional) Determine if the T-body should have a test point. T = Test Point on T-body If no test point is required, do not include a 13th digit. Step 6 Select Digit 14 (optional) Determine whether a 15 kv, 200 A protective cap is required in the kit. C = Protective Cap If no cap is required, do not include a 14th digit. Step 2 Select Digits 9 and 10 Conductor Code Identify the conductor size and type in Table 4 and select the CONDUCTOR CODE from the appropriate (compression or shear bolt) column. S 1 S 3 S 2 OUTER JACKET METAL NEUTRAL OR SHIELD INSULATION SHIELD DIAMETER OVER INSULATION TANK WALL INSULATION CONDUCTOR SHIELD 15 kv S 1 5.0" (126 mm) S 2 0.5" (13 mm) Note: Dimensions given are for reference only. S 3 8.3" (211 mm) Figure 4. BT-TAP profile and stacking dimensions from Figure 11A of IEEE Std 386-2006 standard. CONDUCTOR Figure 3. Illustration showing typical construction of medium voltage underground cable. 4

600 A 15 kv class BT-TAP deadbreak connector Catalog Data CA650002EN Table 4. Conductor Size and Type Compression Connector Concentric or Compressed Compact or Solid AWG or kcmil mm 2 AWG or kcmil mm 2 Compression Conductor Code Shear Bolt Connector Cable Conductor Size AWG or kcmil mm 2 Standard Compact Compressed Concentric Sizes No Connector 0 1/0 1/0 1/0 50 #2 35 1-11 2/0 2/0 2/0 70 #1-1/0 50 12 3/0 3/0 3/0-1/0 50 2/0 70 13 4/0 4/0 4/0 95 2/0 70 3/0-14 250 250 250 120 3/0-4/0 95 15 350 - - 150 4/0 95 250 120 16-350 350 185 250 120 300-17 500 500 500 240 300-350 - 18 600 600 600 300 350-400 185 19 700 - - - 400 185 450-20 - 700 700-450 - 500 240 21 750 750 750-500 240 600 300 22 800 800-400 600 300 700-23 900 - - - 650-750 - 24 750-900 - 25 900-1000 500 26 1000 500 - - 27 1250 630 - - 28 Shear Bolt Connector Conductor Code S1 S3 S4 Catalog Number CDT630SB150 CDT630SB300 CDT630SB400 5

Catalog Data CA650002EN 600 A 15 kv class BT-TAP deadbreak connector To order replacement parts and tools, refer to Table 5. To order replacement compression connectors and cable adapters for a BT-TAP Connector System, see section CA650007EN Deadbreak Accessories, Tools and Replacement Parts. Table 5. Replacement Parts and Tools Description Catalog Number T-body without Test Point DT625 T-body with Test Point DT625T Hex Wrench HD625 Aluminum Stud, Standard Length STUD-A 15 kv, 200 A Insulated Protective Cap LPC215 BOL-T Loadbreak Reducing Tap Plug BLRTP, aluminum BLRTP615A BOL-T Loadbreak Reducing Tap Plug BLRTP, copper BLRTP615C BOL-T Loadbreak Reducing Tap Plug BLRTP, aluminum with stud BLRTP615AS BOL-T Loadbreak Reducing Tap Plug BLRTP, aluminum with stud, Factory installed BLRTP615ASP BOL-T Loadbreak Reducing Tap Plug BLRTP, copper with stud BLRTP615CS BOL-T Loadbreak Reducing Tap Plug BLRTP, copper, Factory installed BLRTP615CSP Aluminum Stud, Extended Length STUDAL Copper Stud, Standard Length STUD-C Copper Stud, Extended Length STUDCL Note: The standard packaging for the BLRTP is a sealed plastic bag. Add X to the end of the catalog number for an individual box. 6

600 A 15 kv class BT-TAP deadbreak connector Catalog Data CA650002EN This page intentionally left blank. 7

Catalog Data CA650002EN 600 A 15 kv class BT-TAP deadbreak connector Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton's Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerrseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA650002EN Eaton, Cooper Power, BOL-T, T-OP, and BT-TAP are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use these trademarks without the prior written consent of Eaton. IEEE Std 386-2006 and Std 592-2007 standards are trademarks of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication is not endorsed or approved by the IEEE. For Eaton s Cooper Power series BT-TAP deadbreak connector product information call 1-877-277-4636 or visit:.