MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Series 8146/5-V37 and Series 8150/5-V37

MEMBRANE VACUUM MINI PUMPS

Plug and Socket Devices CES 63 A Series 8579

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Control and Distribution Boxes made of Stainless Steel Series 8150

Operataing Manual. Single stage radial Fan. Model MKV/TKV

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES

Product Brochure. Certified Mining Motors

Series description: Wilo-Drain TC 40

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Plug and Socket Devices SolConeX 16 A Series 8570

SEISMIC VELOCITY TRANSDUCER T1-40

Italvibras USA. Operator s Manual

Terminal Boxes Series 8146

Reaction Torque Sensor

Mounting Instructions. Torque Transducer. A en

Inductive sensor NI10-M18-Y1X-H1141

TECHNICAL DATASHEET Incremental Encoder RI 58-H

CRN A-F-G-E-HQQE 3x400D 50 HZ

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

2.12. page Products for Explosion hazardous Environment

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Standard offering (pumps)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

3/2-way Solenoid Valve, direct-acting, NC or NO

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Technical Data. Dimensions

Terminal Box. Specifications TNCN

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Technical data sheet TDS0070

Explosion Proof Dynamic Brushless Servo Motors

Fin-cooled motors for the oil, gas, chemical and petrochemical industries. Loher CHEMSTAR and Loher VARIO motors. Explosion-proof motors LOHER

and Accelerometers

Compact pressure switch Flameproof enclosure Ex d Model PCA

Operating Instructions

Thermistor motor protection

A good connection. International approvals.

Redundancy Module QUINT-DIODE/40

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Air blast cooler/radiator DK A03

D.C. Motors. Products and specifications subject to change without notice.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Instructions for Safe Use

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Fluxi 2000/TZ Turbine Gas Meter

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Series description: Wilo-Yonos MAXO

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Water-cooled three-phase asynchronous motors. Type series K21B / K23B

W50 Three-Phase Electric Motor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

CompactLogix Power Supplies Specifications

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

S Y N C H R O N O U S G E N E R A T O R S

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

CRK A-W-A-BUBV

Linear Luminaire with LED Series EXLUX 6402/2

Operating Instructions Drill rig DRU160

3DLevelScanner II TECHNICAL DATA SHEET

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Manual motor starter MS116

Series description: Wilo-Star-Z

Explosion proof enclosures

OJ L 191, , p. 26. OJ L 2, , p. 1.

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Technical Information RIA14

Heating, air-conditioning, cooling

SURGE PROTECTIVE DEVICES

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

EC DECLARATION OF CONFORMITY FOR MACHINES

Three-phase monitoring relay CM-PFE

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

3753 en /b VE/B - VE/RG Va V riable speed drives

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Series description: Wilo-Yonos MAXO-D

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

TEIP11 I/P signal converter for standard signals. Measurement made easy

ELECTROMAGNETIC DISC BRAKES

Selecting and Sizing Ball Screw Drives

Electronic, Digital and Mechanical Vibration Switches

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

A S Y N C H R O N O U S M O T O R S

Transcription:

M3 Designed for industrial continuous duty, the M3 series features a compact shape, reduced overall dimensions, terminal box underneath which means also a high electric protection in dusty environments. Multi-holes mounting feet enable M3 series to match several existing mounting plates. M3 series motors comply with the most recent international standards for use in explosive dust atmospheres. Particularly M3 series can be used in zones 21 and 22. Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz o 60Hz or singlephase 100-130V, 60Hz and 200-240V, 50Hz; suitable for use with an inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and 4 poles. Conformity with European Directives ATEX 94/9/EC. Low Voltage 2006/95/EC. Reference Regulations IEC/EN 61241-0, IEC/EN 61241-1, EN 60034-1. Functioning Continual service (S1) at maximum declared centrifugal force and electric power. Intermittent services are also possible depending on the type of vibrator and the operating conditions. For detailed information contact our technical assistance office. Range up to 311 f (3.05 kn). can be changed by adjusting the eccenctric weights Protection against mechanical impacts IK 08 according to IEC 68, EN 50102. Insulation Class F (155 C). Tropicalization Standard with vacuum encapsulation. Ambient temperature From -20 C to +40 C. Versions for higher or lower temperatures are available on request. Vibrator thermal protection On request with PTC thermistor rated heat detectors 130 C (DIN 44081-44082). Fixing of the vibrator In all positions and therefore without restriction. The terminal box is positioned underneath the vibrator, on the same side as the fixing base. Lubrication Sealed ball bearings, lubricated for life. Mechanical protection IP 66 according to IEC 529, EN 60529. 48

Category: II 2 D Level of protection: td A21 IP66 Temperature : 120 C EC certificate: LCIE 05 ATEX 6163 X Areas of use: 21, 22 Certifications Terminal box The terminal box is positioned underneath the vibrator, on the same side as the fixing base. Special shaped terminals allow to fix the power supply cable, protecting it from loosening. Electric motor Three-phase or single-phase asynchronous type. Insulated windings using vacuum encapsulating. The rotor is die cast aluminium. Casing In high-tensile aluminium alloy, with sand blasted surface. Bearing flange In ductile cast iron. The geometry of the flange transmits the load to the casing uniformly. Motor shaft In treated steel alloy (Isothermic hardening) resistant to stress. Eccentric weights Easily adjustable from 100% down to 0. eight covers Made in die cast, high strength alluminium alloy with accurate surface sand blasting. Regulation CAN/CSA - C22.2 N. 100-95, file n LR100948 Class 4211 01 Motors and generators. Mechanical protection IP66 (EN 60529), protection against impacts IK 08 (EN 50102) II 2 D, td A21 IP66 IEC/EN 61241-0, IEC/EN 61241-1 Certificate n. LCIE 05 ATEX 6163X Certificate GOST-R n POCC IT.ГБ04.B01154, standards GOST R 51330.0-99, GOST R 51330.1-99, GOST R 51330.8-99, GOST R IEC 61241-1-1-99 Certificate of Conformity n IECEx CES 09.0001X standards IEC 61241-0, IEC 61241-1. Comply with the applicable European Union directives 49

M3 2 poles - 3000/3600 rpm three-phase Description Code Type SIZE II2D Mechanical specifications Static moment* eight mm kn 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz Electrical specifications Max input Max. current power A IA/lN 400 V 460 V 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 600467 M3/65-S02 00 120 C 6.43 6.43 64.7 93.1 0.635 0.913 4.3 4.3 120 120 0.27 0.23 3.43 3.90 600465 M3/105-S02 00 120 C 9.64 9.64 97.0 140 0.950 1.37 5.2 5.2 180 180 0.35 0.30 2.68 3.00 600462 M3/205-S02 00 120 C 21.0 21.0 211 304 2.07 2.98 6.0 6.0 180 180 0.35 0.30 2.68 3.00 600461 M3/305-S02 00 120 C 31.0 21.0 311 304 3.05 2.98 6.3 6.0 180 180 0.35 0.30 2.68 3.00 single-phase 600467 M3/65-S02 00 120 C 6.43 6.43 64.7 93.1 0.635 0.913 4.3 4.3 110 110 0.56 1.52 2.24 2.24 600465 M3/105-S02 00 120 C 9.64 9.64 97.0 140 0.950 1.37 5.2 5.2 165 165 0.75 1.52 1.67 2.24 600462 M3/205-S02 00 120 C 21.0 21.0 211 304 2.07 2.98 6.0 6.0 165 165 0.75 1.52 1.67 2.24 220 V 50 Hz 115 V 60 Hz 600461 M3/305-S02 00 120 C 31.0 21.0 311 304 3.05 2.98 6.3 6.0 165 165 0.75 1.52 1.67 2.24 4 poles - 1500/1800 rpm threephase singlephase Description Code Type SIZE II2D Mechanical specifications Static moment* eight mm kn 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz Electrical specifications Max input Max. current power A IA/lN 400 V 460 V 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 601514 5/36-S02 00 120 C 12.0 12.0 30.2 43.5 0.30 0.43 5.4 5.4 85 95 0.21 0.20 1.78 1.95 601515 5/81-S02 00 120 C 31.0 21.0 77.9 76.1 0.76 0.75 6.3 6.0 85 95 0.21 0.20 1.78 1.95 601514 5/36-S02 00 120 C 12.0 12.0 30.2 43.5 0.30 0.43 5.4 5.4 90 100 0.43 1.00 1.20 1.30 601515 5/81-S02 00 120 C 31.0 21.0 77.9 76.1 0.76 0.75 6.3 6.0 90 100 0.43 1.00 1.20 1.30 220 V 50 Hz 115 V 60 Hz * orking moment = 2 x static moment. IA/lN = ratio between start-up current and maximum current. 50

Fig. Dimensional specifications (mm) Multi-hole Holes Type Fig. A B C D E øg N F H I ØL M N P M3/65-S02 197 40 Condenser (μf) 220 V 50 Hz 115 V 60 Hz Cable entry thread M3/105-S02 211 30-60 85-100 47 123 127 9 4 24 70 M3/205-S02 235 65-62 85-106 59 106 86 106 88,5 - - M20x1,5 M3/305-S02 235 59 M3/65-S02 197 40 M3/105-S02 211 30-60 85-100 47 123 127 9 4 24 70 M3/205-S02 235 65-62 85-106 59 106 86 106 88,5 10 28 M20x1,5 M3/305-S02 235 59 Type Dimensional specifications (mm) Multi-hole Holes Fig. A B C D E øg N F H I ØL M N P Condenser (μf) Cable entry thread 5/36-S02 5/81-S02 235 123 127 30-60 65-62 85-100 85-106 9 4 24 70 59 106 86 106 88.5 - - M20x1,5 5/36-S02 5/81-S02 235 123 127 30-60 65-62 85-100 85-106 9 4 24 70 59 106 86 106 88.5 3.15 25 M20x1,5 51

M3-E The M3-E is designed for use in industrial processes in environments with a potentially explosive atmosphere, caused by gas and dust, in compliance with ATEX Directive (94/9/ EC). In particular, the M3-E can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts) according to the layout and the following features: Technical features Power supply Three-phase voltage 127/220V 50Hz, 200/346V 50Hz, or 210/363V 60 Hz; suitable for use with an inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 poles. Conformity with European Directives Low Voltage 2006/95/EC, ATEX 94/9/EC. Reference Regulations IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0, IEC/EN 61241-1, EN 60034-1. Controls The components that affect protection are 100% accurately controlled and recorded. Functioning Continual service (S1) at maximum declared centrifugal force and electric power. Intermittent services are also possible depending on the type of vibrator and the operating conditions. For detailed information contact our technical assistance office. Range up to 311 f (3.05 kn). can be changed by adjusting the eccenctric weights. Mechanical protection IP 66 according to IEC 529, EN 60529. Protection against mechanical impacts IK 08 according to IEC 68, EN 50102. Insulation Class F (155 C). Tropicalization Standard with vacuum encapsulation. Ambient temperature From -10 C to +40 C, on request it is possible to have vibrators for max. ambient temperatures of +55 C. Vibrator thermal protection On request with PTC thermistor rated heat detectors 130 C (DIN 44081-44082). Fixing of the vibrator In all positions and therefore without restriction. The terminal box is positioned underneath the vibrator, on the same side as the fixing base. Lubrication Sealed ball bearing, lubricated for life. three-phase 2 poles - 3000/3600 rpm Description Code Type SIZE Static moment* mm Mechanical specifications eight kn 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 600467 M3/65-E-S02 00 6.43 6.43 64.7 93.1 0.635 0.913 4.3 4.3 600465 M3/105-E-S02 00 9.64 9.64 97.0 140 0.950 1.37 5.2 5.2 600462 M3/205-E-S02 00 21.0 21.0 211 304 2.07 2.98 6.0 6.0 600461 M3/305-E-S02 00 31.0 21.0 311 304 3.05 2.98 6.3 6.0 * orking moment = 2 x static moment. te (s) = set time te from IEC/EN 60079-7. (G) (D) Electrical specifications Max input Power Max. current power rating A 400 V 460 V 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz T4 120 C 105 105 80 80 0.30 0.29 20 t E (s) 52

Certifications Category: II 2 G,D Level of protection: Ex e II, td A21 IP66 Temperature : Gas: T4 (135 C) Dusts: 120 C EC certificate: LCIE 06 ATEX 6092 X Areas of use: 1, 2, 21, 22 II 2 G, D Class Ex e II T4/T3 td A21 IP 66. IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0, IEC/EN 61241-1. Certificate n LCIE 06 ATEX 6092 X GGTN Permit and Gost-R certificate for increased safety Ex e: GOST R 51330.0-99, GOST R 51330.8-99, GOST R IEC 61241-1-1-99. Certificate of Conformity n IECEx LCI 10.0003X following standards IEC 61241-0, IEC 61241-1, IEC 60079-0, IEC 60079-7 Comply with the applicable European Union directives Terminal box The terminal box is positioned underneath the vibrator, on the same side as the fixing base. Special shaped terminals allow to fix the power supply cable, protecting it from loosening. Electric motor Three-phase asynchronous type. Insulated windings using vacuum encapsulating. The rotor is die cast aluminium. Casing In high-tensile aluminium alloy, with sand-blasted surface. Eccentric weights Easily adjustable from 100% down to 0. eight covers Made in die cast, high strength alluminum alloy with accurate surface sand blasting. Other features For the M3-E series, the user must fill the terminal box with suitable silicone, after having performed the connection. Bearing flange In ductile cast iron. The geometry of the flange transmits the load to the casing uniformly. Motor shaft In treated steel alloy (Isothermic hardening) resistant to stress. Fig. IA/lN Type Dimensional specifications (mm) Multi-hole Holes Fig. A B C D E øg N F H I L M M Cable entry thread 3.48 M3/65-E-S02 197 40 3.68 M3/105-E-S02 211 30-60 85-100 47 123 127 9 4 24 70 3.68 M3/205-E-S02 235 65-62 85-106 59 106 86 106 M20x1,5 3.68 M3/305-E-S02 235 59 IA/lN = ratio between start-up current and maximum current. 53