W50 Three-Phase Electric Motor
|
|
|
- Gyles Lee
- 9 years ago
- Views:
Transcription
1 Motors Automation Energy Transmission & Distribution Coatings W50 Three-Phase Electric Motor Technical Catalogue IEC Market
2 W50 - The New Generation of WEG Motors for Heavy Duty Applications The W50 motor platform is the most modern option for applications that require high performance and reliability. The scenario of increasing demand for more compact and efficient electric motors creates the need to develop new products with higher performance, quality, reliability and that exceed the requirements of customers. It is with this concern that WEG introduces its new line of motors for heavy duty applications: the W50. The W50 motor offers excellent performance and complies with the strictest criteria of efficiency and safety. Its design was developed using a series of sophisticated computational tools for electromagnetic, structural and thermal analysis and optimization, resulting in a compact, and roboust product with high performance. Its frame ensures great mechanical strength to the motor and its fins provides great heat dissipation, which results in longer lifetime and higher levels of energy efficiency. The W50 platform also includes optimizations in the supply chain in order to reduce waste and CO 2 emission rates, reinforcing the WEG group concern with the green thinking. 2 W50 - Three-Phase Electric Motor
3 Main Features and Benefits of the W50 Motors Compact design Modular construction Low vibration levels High thermal efficiency High energy efficiency High mechanical strength High performance in the most demanding operating conditions Low starting current Designed for operation with frequency inverter W50 - Three-Phase Electric Motor 3
4 Visual Index Air baffle 2 Sealing system 3 DE-endshield 4 Shaft 5 Eyebolt 6 Accessory terminal box 7 8 Earth terminal in the frame 9 Main terminal box 10 Fan 11 Bearing 12 NDE-endshield 13 Earth terminal in the terminal box 14 External fan 15 Fan cover 16 Internal air baffle 17 Round steel screen Table 1 - Part description. 4 W50 - Three-Phase Electric Motor
5 Table of Contents 1. Standards Construction Details Eyebolts Grounding Terminals Grounding Brush Terminal Box Stator Winding Endshields Drains Fan Cover Air Baffle Nameplate Ventilation System/Noise Level/Vibration Level Ventilation System Noise Level Vibration Shaft/Bearings/Stresses Shaft Bearings Maximum Radial and Axial Loads Mounting Forms Degree of protection/bearing Sealing/Painting Degree of Protection Bearing Sealing Painting Voltage/Frequency Environment Operation Characteristics Thermal Protection Operation with Frequency Inverter Installation Characteristics Strength and Mass of the Motor Mechanical Support System (MSS) Dimensional Control Special Accessories Encoder Protection Against Voltage Surge Leveling Screw Non-Reverse Ratchet Thermometer Interchangeability Solutions Automatic Lubricator Construction Features Optional Features Electrical Data W50 - Low Voltage W50 - High Voltage kv to 5.0 kv W50 - High Voltage kv to 6.6 kv Mechanical Data s 315 H/G to 450 J/H Flange FF External Motor Dimensions with Steel Plate Terminal Box External Motor Dimensions with Sleeve Bearing External Motor Dimensions with Forced Ventilation Drip Cover Height Terminal Box Drawings Cast Iron Terminal Boxes Steel Plate Terminal Boxes Packaging Spare Parts...42 W50 - Three-Phase Electric Motor 5
6 1. Standards The W50 motors meet the requirements and regulations of the current versions of the following standards: Standard IEC EN IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC Table 2 - Standards observed in the motor design. 2. Construction Details Title Rotating electrical machines Part 1: Rating and performance Rotating electrical machines Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles) Dimensions and output series for rotating electrical machines. Part 1: numbers 56 to 400 and flange numbers 55 to 1080 Dimensions and output series for rotating electrical machines. Part 2: numbers 355 to 1000 and flange numbers 1180 to 2360 Rotating electrical machines Part 8: Terminal markings and direction of rotation Rotating electrical machines Part 7: Classification of types of construction, mounting arrangements and terminal box position (IM Code) Rotating electrical machines - Part 11: Thermal protection Rotating electrical machines Part 6: Methods of cooling (IC Code) Rotating electrical machines Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity Rotating electrical machines - Part 9: Noise limits Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors IEC standard voltages Explosive atmospheres - Part 0: General requirements Explosive Atmospheres Part 15: Equipment protection by type of Protection n Degrees of Protection Provided by Enclosures for Electrical Equipment Against External Mechanical Impacts (IK CODE) The information contained herein refers to the standard mounting features and the most common variants of the W50 line. Motors for special and/or customized application are also available on request. Please, contact the nearest WEG office. 2.1 Produced in cast iron FC-200, the frames of the W50 motors withstand high mechanical impacts, ensure maximum heat dissipation and high mechanical strength and reduce mechanical vibration even when transmitted by external sources. In addition, fins are distributed to have a greater heat dissipation area in the frontal area, which contributes to a uniform temperature distribution throughout the whole motor and reduces the DE bearing temperature. Thus, this unique fin distribution design ensures excellent thermal performance of the motor. Figure 1 - W50. The motor has solid and integrated cast feet which provide greater strength (see Figure 2). Figure 2 - Solid integrated cast feet ensuring high mechanical strength. 2.2 Eyebolts To facilitate lifting to the different mounting positions, the W50 motors have multiple points for attaching eyebolts. Motors with feet: Standard: five points for attaching eyebolts. Optional: nine points for attaching eyebolts (the five standard points plus four additional points - two on each motor foot). Figure 3 - Eye-bolt fixing points for motors with feet. 6 W50 - Three-Phase Electric Motor
7 Motors with two terminal boxes are provided with three main points for lifting eyebolts (two on the back and one in the center). Figure 7 - Lifting with vertical chains. Figure 4 - Eyebolt fixing points for lifting motors with two terminal boxes. Footless motor: Standard: nine eyebolts (five at top side and four at bottom side). Optional: nine standard eyebolt fixing points plus and one additional eyebolt fixing point located at the bottom side center. For lifting motors with inclined chains, the maximum inclination angle of the chain during the lifting process should not exceed 30º in relation to the vertical axis. We recommend to use a spreader bar for maintaining the lifting elements (chain or ropes) in vertical position and thus preventing damage to the motor surface. Figure 5 - Eyebolt fixing points for lifting footless motors (at the bottom side). Figure 8 - Lifting with inclined chains. Vertical motors: For lifting of vertical mounted motors always use the eyebolts mounted at the top side of the motor, diametrically opposite, considering the mounting position (see Figure 9). In these cases, it is also necessary to use a spreader bar. Figure 6 - Eyebolt fixing points for lifting footless motors (at the top side). Note: Horizontal motors: For lifting of horizontal mounted motors use all eyebolts simultaneously. For this procedure, there are two ways: vertical chains (see Figure 7) and inclined chains (see Figure 8). Figure 9 - Lifting of vertical motors. W50 - Three-Phase Electric Motor 7
8 Motors with two main terminal boxes: For lifting of motors with two terminal boxes, use always three eyebolts as shown in Figure 10. The motors can optionally be supplied with an AEGIS shaft grounding ring (see Figure 13) installed on the inner bearing cap for external use can be supplied on request. Figure 10 - Lifting of motors with two main terminal boxes. 2.3 Grounding Terminals The W50 motors are fitted with grounding terminals on the frame (see Figure 11) and inside the main terminal box. These terminals can be positioned on the right or left side of the frame and have cross-section from 25 to 185 mm 2. Figure 13 - AEGIS grounding ring. Note: The incorrect specification and/or inadequate use of the grounding devices can cause serious damage to the machine and people involved in the operation of the motor. Before powering up the motor, ensure that it is properly grounded and that all grounding components are in perfect operating conditions. 2.5 Terminal Box The W50 line has specific terminal boxes for motor power cables and accessory cable connections. Figure 11 - Detail of the standard grounding terminal for the main terminal box and frame. 2.4 Grounding Brush The motors can also be supplied with a grounding brush in the drive end as an optional item. For operation with variable frequency inverter, W50 motors are always fitted with shaft grounding brush at motor drive end (see Figure 12) and insulated non-drive end bearing to avoid current flow along the motor shaft, across the bearing and return to the frame thus preventing premature bearing wear and failure due to electric currents flowing through them Main Terminal Box It can be manufactured in cast iron FC-200, the same material used in the frame and endshields, or steel plate, and due to its mounting it can be rotated in steps of 90. The main terminal box has been designed for easier and ergonomically handling during cable connection procedures. In addition, the terminal box is mounted on a support on the top of the motor, allowing easy change of the terminal box position (see Figure 14). Figure 14 - Changing possibilities of the terminal box position. Low voltage motors are supplied with six cables connected to a terminal block, allowing direct online or star/delta starting. Figure 12 - Shaft grounding brush for bearing. 8 W50 - Three-Phase Electric Motor
9 2.5.2 Accessory Terminal Box The W50 motors have a specific terminal box for connecting accessories. This box is also manufactured in cast iron FC-200 and comprises two compartments (see Figure 18). Figure 15 - Terminal block for low voltage motors with six terminals. High voltage motors are supplied with three connection bolts and are supplied with terminal block as standard (see Figure 16). Figure 18 - Accessory terminal box. 2.6 Stator Winding The stator windings of the W50 motors, regardless of voltage, are supplied with Class F insulation system and Class B temperature rise (80 K). Optionally, the motors can be supplied with Class H insulation system and Class B temperature rise (80 K). Other insulation system combinations can be supplied on request. Figure 16 - Terminal block for high voltage motors with three terminals. Note: J J The tightening torque of the terminals for motors with high and low voltage must comply with the standard DIN The terminal box for high voltage motors is provided with a pressure relief device that ensures component integrity and user safety in case of short circuit. In case of activation of the pressure relief device, please contact WEG authorized servicing center. For safety reasons, this device must never be reassembled and never operate the motor without this safety device installed. To monitor the motor heating, the windings are fitted with two sets of Pt-100 per phase and with a set of space heaters in order to prevent water condensation inside the motor. The space heaters are mounted in the air ducts on both sides of the motor, for easy maintenance. On request, the high voltage motors can also be supplied with an additional terminal box mounted at the opposite side of the main terminal box to enclosure the star point (see Figure 17). High voltage motors can be supplied with surge arrester and/ or surge capacitors assembled in specific terminal box (see Section 11. Special accessories). Figure 19 - Air ducts of the frame for air flow. Since the lifetime of the motor is influenced by the temperature at which it operates, thus it is important to constantly monitor the winding temperature. Note: J J The space heaters must always be switched on when the motor is out of service for long periods and switched off when the motor is is running, thereby preventing the deterioration of motor components and possible overheating. Figure 17 - Motor with access to neutral connection in separated terminal box. The W50 High Voltage insulation systems are designed with mica tape layers and impregnated with epoxy resin through Vacuum Pressure Impregnation - VPI process and carefully manufactured and tested at factory thus ensuring a end product with high levels of reliability, preventing W50 - Three-Phase Electric Motor 9
10 contamination of the impregnation varnish and ensuring voidfree impregnation of windings. For motors that operate with a non sine wave frequency inverter, insulation systems are reinforced to prevent accelerated aging of insulation (available on request). 2.7 Endshields To improve heat dissipation and ensure lower operating temperatures on the bearing, the DE endshield is provided with fins uniformly distributed. The endshields are manufactured in cast iron FC-200 and fastened with 8 bolts to ensure maximum rigidity (see Figure 20). 2.9 Fan Cover The fan covers are built in cast iron FC-200 (see Figure 23), have an aerodynamic design, features high mechanical resistance to loads and impacts which allows their application in environments with risk of mechanical impact up to 5 Joules (IK08 according to standard IEC 62262). For motors with sleeve bearings, the fan cover is made of steel plate with the same features as the cast iron version. Figure 23 - Fan cover manufactured in cast iron FC-200. Figure 20 - DE endshield (left) and NDE endshield (right). Depending on its mounting, the W50 can be provided with flange type FF, as shown in Figure 21. Thanks to the new baffle design along with the new arrangement of the frame fins, the W50 ensures optimal air flow and air speed over the frame. The shape of the baffle ensures increased efficiency of the ventilation system, which improves the thermal performance and efficiency of the motor. The unique mounting system of the grid and internal baffle (see Figure 24) ensures low noise levels - even lower than noise levels stablished by the standardards. Figure 21 - DE endshield - Flange FF. 2.8 Drains W50 has automatic drain plugs with degree of protection IP66 (see figure 22) which do not require human intervention to open the plug and avoid accumulation of condensed liquids into the motor. Figure 24 - Mounting system that ensures low noise levels Air Baffle The W50 also has a pair of air baffles made of cast iron on the DE bearing. It was designed in order to guarantee a continuous and uniform airflow over the bearing housing, which significantly lowers its temperature and consequently increases relubrication intervals and bearing life (see Figure 25). Motors with sleeve bearings are supplied with two pairs of air baffles (see Figure 26). Figure 22 - Positions of automatic drains on the motors of the W50 line mounted in the horizontal and vertical position. Figure 25 - Representation of the air flow over the DE bearing. 10 W50 - Three-Phase Electric Motor
11 Main Nameplate The main nameplate provides information describing the mounting features and motor performance. It also iprovides the motor serial number and its year of manufacture. Figure 28 shows the layout of the nameplate on the W50 motor. Figure 26 - Two pairs of air baffles for motors with sleeve bearings. It is noteworthy to mention that for proper motor operation air inlets for motor ventilation are not blocked and that the space surrounding the equipment is enough to keep the air temperature at the baffle inlet below the maximum temperature indicated on the motor main nameplate. For motors installed outdoors ensure that ventilation openings are not blocked and a minimum clearance of 1/4 of the baffle diameter is maintained from the walls to ensure free airflow for the ventilation system. For indoor installations, besides the minimum distance from walls, the air temperature must be checked at the air inlet of the ventilation system to prevent motor overheating. Motors installed outdoors or in vertical position require the use of additional shelter to protect them against the ingress of rainwater and/or solid particles, for instance the use of a drip cover. Note: J J The mounting features of the fan cover must not be changed, because they are designed to ensure maximum efficiency of the fans Figure 28 - Main nameplate of the motor. 1 Motor line 2 Motor code 3 Manufacturing date 4 Serial number 5 Efficiency level 6 Certification 7 Number of phases 8 Output power 9 model 10 Rated voltage 11 Frequency 12 Rated current 13 Duty factor Nameplate The motors can be supplied with three types of nameplate: main, additional and warning nameplate. All nameplates are made of AISI 304 stainless steel and the main and additional plates are laser engraved. Figure 27 shows the location of the nameplates on the W50 motor. 14 Speed 15 Power factor 16 Duty cycle 17 Ambient temperature 18 Insulation class 19 Temperature rise of the windings 20 Degree of protection 21 Altitude 22 Weight 23 Wiring diagram 24 DE bearing and grease quantity 25 NDE bearing and grease quantity 26 Bearing s relubrication interval (in hours) 27 Grease type used for bearings Table 3 - Description of the items on the motor main nameplate. Figure 27 - Location of the nameplates on the electric motor. W50 - Three-Phase Electric Motor 11
12 Additional Nameplate To indicate the available accessories, the W50 motors are supplied with additional nameplates that contain informations on temperature sensors (see Figures 29 and 30), space heaters (see Figure 31), and other accessories supplied on customer request. If required, these nameplates can be used to show the TAG codes specific to the motor. Figure 32 - Warning plate for motors above 1 kv. 3. Ventilation System/Noise Level/ Vibration Figure 29 - Additional nameplate for winding temperature detectors (Pt-100). Figure 30 - Additional nameplate of the temperature sensor (Pt-100) for the bearings. Figure 31 - Additional nameplate for the space heater. Note: J J When motor is fitted with dual voltage space heaters, WEG supplies the motor connection set for 127 V. If required to connect to 220 V, the wiring diagram must be changed as shown on the additional nameplate of the space heater. 3.1 Ventilation System The motors of the W50 line comply with the specification of Totally Enclosed Fan Cooled motors (TEFC - IC-411) according to NEMA MG-1 Part 6. The optional version with forced ventilation (IC 416) can also be provided. On request, WEG can supply non-ventilated (TENV) and Air Over (TEAO) versions. Further information on the IC 416 option can be found in item 9.2 Operation with Frequency Inverter Fans With an innovative ventilation system, W50 motors have a uniform distribution of internal temperature. This system produces a pressure difference between the drive end and non-drive end of the motor, resulting in an air flow through the rotor cooling channels (see Figure 33). The internal ventilation system results in an homogeneous temperature distribution along the stator, and also helps to reduce the bearing temperature levels. The internal ventilation system adopted for the W50 motors is simple and compact and provides the required air flow while increasing the cooling efficiency and reducing the vibration levels Warning Plate Motors with rated voltage above 1 kv are supplied with a warning nameplate (see Figure 32), indicating the presence of high voltage on the motor. Never touch any energized circuits or rotating parts of the motor. Maintenance, installation and any interventions must be performed by qualified staff with appropriate tools only. For more details contact WEG technical support. Figure 33 - Airflow channels in the motor frame. 12 W50 - Three-Phase Electric Motor
13 The W50 2P motors are fitted with axial fans (figure 36) and with 4 or more poles are fitted with radial fans, ensuring low noise levels and high ventilation efficiency. Made of cast iron FC-200, the fans are unidirectional for 2-pole motors and bidirectional for four or more poles. For 2 pole motors, the direction of rotation must be specified by the customer. Aluminum fans can also be supplied on request. Figure 34 - Radial fan with straight blades.. Note: J J The sound pressure level increase for motors driven by frequency inverter that depends on the switching frequency of the inverter, may reach up to maximum 11 db (A) according to IEC and IEC Vibration The vibration of an electrical machine is directly related to its installation conditions. For this reason, it is extremely important that the customer ensures a sturdy base and the required dimensional tolerances. To prevent equipment damage, vibration levels should be monitored regularly and any abnormal behavior must be immediately reported to the nearest authorized repair shop and/or to WEG. Motors with rolling bearings are highly sensitive to vibrations, and can suffer premature wear if exposed to vibrations above the acceptable limits. It is recommended that vibration measurements be always performed before and after any maintenance or intervention on the equipment. Whenever possible, the vibrations generated only by the motor must be evaluated by no-load tests, following the procedures described in IEC According to Table 6, the limits of maximum vibration magnitude in displacement, velocity and acceleration defined by IEC for motors operating at no-load are classified into vibration grade A and B. Vibration grade Mounting Displacement (µm) Velocity (mm/s) Acceleration (m/s²) Figure 35 - Axial fan with inclined blades. 3.2 Noise Level Table below shows the noise levels of the W50 motor plattform. The data refers to motors operating at 50 Hz and 60 Hz with fan covers made of cast iron. For lower speeds, please contact WEG. Sound pressure level db(a) - 50 Hz 315 H/G J/H 400 L/K 400 J/H 450 L/K 450 J/H Sound pressure level db(a) - 60 Hz 2P 4P 6P 8P 2P 4P 6P 8P Table 4 - Sound pressure level for motors at 50 Hz and 60 Hz with fan cover made of cast iron. The sound pressure levels shown in the tables above are valid for motors operating with no load and sine-wave power supply. Under load, IEC specifies a sound pressure level increase according to Table 5. A B Free suspension Rigid mounting Free suspension Rigid mounting Table 6 - Limits of maximum vibration magnitude in displacement, velocity and acceleration according to the IEC When no special vibration requirements are specified in the Purchase Order, motors will be supplied in conformance with vibration grade A, while motors in conformance with vibration grade B will be supplied only on request. All rotors of the W50 motors are dynamically balanced with a half key and, as standard, are designed to vibration grade A. According to IEC , the standard motors are balanced to Grade G2.5. For special and lower vibration levels the balance quality grade is G2.5. For vibration monitoring, the D-endshield of the W50 motors has three M8 threaded holes where vibration sensors can be fitted. Optionally, these holes can be supplied with a threaded adapter for fitting the SPM vibration sensor (see Figure 37). Height of the shaft end - H (mm) 2P 4P 6P 8P H = H Table 5 - Maximum expected increase of the sound pressure level for motors operated with load. W50 - Three-Phase Electric Motor 13
14 4. Shaft/Bearings/Stresses Figure 36 - SPM Sensors. Figure 37 - Threaded adapter for vibration measurement. The frames also have flat areas for mounting of vibration sensors at the motor non-drive end. On request, non-drive end shields can be supplied with threaded holes for sensor mounting. Figure below shows the measuring point locations (see Figure 38). On request, the vibration sensors can be supplied with the motor. 4.1 Shaft The shafts of the W50 motors comply with IEC and undergo several numerical analyses until reaching the final dimensioning. Among the evaluation steps are: calculation of fatigue considering the stress concentration, torsion, bending and traction-compression efforts, stress and deformation analysis, torsional and modal analysis. In order to facilitate the maintenance and the coupling of loads, all motors have the shaft with threaded center hole. The standard shaft material is AISI 4140 steel, and supplied with key type A according to ISO On request, WEG can also supply double-end shaft motors, shaft end with special dimensions, and shafts made of other materials. The dimensions for the shaft and key can be found in section 15. Mechanical Data. 4.2 Bearings The standard motors are supplied with open ball bearings with C3 clearance and lubricated with grease. On request, motors with ball bearings can be supplied with C4 clearance. All motors are supplied with Pt-100 temperature sensors in the windings as standard thus ensuring an efficient method for continuous temperature monitoring during operation. Standard motors are supplied with taconite labyrinth seals and, as an option, they can be supplied with INPRO / SEAL or labyrinth with Teflon Seal. Figure 39 shows the bearing construction form. Figure 38 - Location of vibration measuring points Shaft Relative Vibration Limits For machines with sleeve bearings with speed over 1,200 rpm and at rated power over 1,000 kw, IEC recommends relative shaft vibration measurements (see Table 7). Sensor readings may be affected by mechanical and magnetic anomalies of the shaft, commonly referred to as runout. Vibration grade Grade A Grade B Speed range Maximum vibration (µm) Runout (µm) (peak-to-peak) >1, , >1, , Table 7 - Maximum relative shaft displacement. Figure 39 - Bearing construction form. The vertical motors, for normal thrust loads can be supplied with ball bearings or angular contact ball bearings at the drive side, considering frame size and speed. This bearing configuration ensures optimum operating conditions for the motor in different applications and also prevents possible coupling problem caused due to thermal expansion. The rated bearing lifetime, L10h, for direct coupling of the W50 line motors is 100,000 hours ( hours on frame size 450J/H 2-pole) and for other operating conditions the bearing lifetime, L10h, is 40,000 hours. Different bearing lifetime L10h can be evaluated on request. The rolling bearing lifetime depends on the type and size of the bearing, the radial and axial loads they are subject, the operating conditions, the speed and grease life. Thus, its lifetime is closely related to its correct use, maintenance and lubrication. When the recommended amount of grease and lubrication intervals are respected, the bearings can reach the lifetime aforementioned. 14 W50 - Three-Phase Electric Motor
15 Note: J J The bearing lifetime, L10h, in terms of operating hour, is the life that 90% of bearings is reached or even exceeded when motors are operated in compliance with the data provided in this catalog. Table 8 lists the standard rolling bearings for different configurations of the W50 line. Horizontal mounting Vertical mounting Normal thrust 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H Number of poles DE NDE C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C3 Horizontal mounting with sleeve bearings Number of poles DE NDE 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H Table 10 - Standard bearings per frame for motors with sleeve bearing Shaft Locking Device The W50 motors are fitted with a mechanical shaft locking device to prevent damage to the rotor and bearings during transportation (see Figures 41, 42 and 43). This locking device should only be removed right before installation and stored in a safe location for future transportation of the motor. Table 8 - Standard rolling bearings per frame size. Optionally, motors with horizontal mounting for applications with high radial loads can be supplied with roller bearings of the NU series, according to Table 9. Figure 41 - Shaft locking device for motors with rolling bearing. Number of poles Rolling bearing DE 315 H/G 4-8 NU320 C3 355 J/H 4-8 NU322 C3 400 L/K and 400 J/H 4-8 NU324 C3 450 L/K and 450 J/H 4-8 NU328 C3 Table 9 - Optional roller bearings of the NU series. The W50 motors can also be supplied with sleeve bearings with lateral flange and natural cooling (see Figure 40). This option ensures lower maintenance and longer bearing life in non-heavy duty applications with direct coupling. Depending on the customer requirements, other configurations can be supplied on request. Figure 42 - Shaft locking device for motors with special bearing. Figure 43 - Shaft locking device for motors with sleeve bearing. Figure 40 - Sleeve bearing. Table 10 lists the standard bearings for motors with sleeve bearings Insulated Bearing In order to avoid bearing damage caused by electrical discharges generated inside the bearings, the W50 motors are fitted as standard with insulated NDE bearing (Figure 44). Currents flowing through the bearing have the potential of creating premature failure of theses bearings, accelerating the degration og the lubricant and of the bearing rolling elements. W50 - Three-Phase Electric Motor 15
16 For all motors driven by frequency inverter, the electrical insulation of the NDE bearing and grounding between shaft and frame through grounding brush at drive end is mandatory. Figure 44 - Insulated NDE endshield. Horizontal motors with sleeve bearings, when required, both endshields may be supplied with insulation. Vertical motors with high thrust loads are also supplied with insulated DE bearing. For other configurations, contact WEG Lubrication Bearing Lubrication The W50 motors are fitted with a lubrication system with grease nipples on the DE and ND endshields, and a grease outlet drawer system for removing the old grease. The amount of grease and lubrication intervals are informed on the motor nameplate, and are also specified in Table 11. Horizontal mounting- ball bearings Vertical mounting- ball bearings Horizontal mounting- roller bearings 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H Number of poles DE bearing Grease (g) Hz (h) 60 Hz (h) NDE bearing Grease (g) 3, Hz (h) 60 Hz (h) 3, , ,500 4,500 4, , , , , ,800 2, ,800 1, ,500 4, ,500 4, ,000 2, ,000 2, ,500 3, ,500 4, , ,500 1, ,500 1, ,200 3, ,500 4, ,500 4, ,500 1, ,500 1, ,600 2,700 3, , ,500 4,500 4, ,000 1, ,000 1, ,200 2,300 3, ,500 4,500 4,300 4, , ,500 1, ,500 1, ,400 1, ,100 3, ,500 4, ,300 2,900 NU ,500 4, ,500 2,200 NU ,500 4,500 4 NU ,900 1, ,500 4, ,000 1,400 6 NU ,500 3, , ,500 2,700 4,500 4,500 Table 11 - Relubrication intervals and amount of grease for grease lubricated bearings. IIt is extremely important to follow the lubrication intervals specified on the motor nameplate. An excessive or insufficient lubrication may increase the bearing temperature during operation, resulting in premature wear of the bearings and consequent reduction of their lifetime. Table 12 specifies the standard type of grease for the motors and indicates some properties of the lubricating grease. Besides the greases already mentioned in the table, there are others that are compatible with the design of the W50 and can also be used. For these cases refer to WEG respective Installation, Operation and Maintenance Manual. Number of poles Lubricant 315 H/G J/H L/K and 400 J/H L/K and 450 J/H 2-8 Mobil Polyrex EM Table 12 - Typical properties of the standard lubricant. Note: Lubricant specification Grease with mineral oil, polyurea-based thickener, ISO VG 115 J J For operation of the motors under other than normal operating conditions, such as: ambient temperature above 40 C, altitude higher than 1,000 m above sea level and axial and/or radial load above the specified in the tables in this catalog, please refer to WEG. J J The use of greases not recommended by WEG or in different amounts than specified above may void the product warranty. Motors with ball bearings at the drive end (DE) and at the non-drive end (NDE) are fitted with bearings caps and locating bearing at DE and non-locating bearing at NDE with preload washer. When motor is fitted with roller bearing at the drive end, special bearing caps are assembled at the nondrive end where the locating bearing is assembled. Sleeve Bearing Lubrication Depending on the application the W50 motor can be supplied with sleeve bearings available on request. This type of bearing requires less maintenance ensures longer lifetime and relubrication intervals. Table 13 provides key information about lubricants for sleeve bearings. Mounting - sleeve bearings No. of poles H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H Bearing H/G J/H L/K and 400 J/H 450 L/K and 450 J/H Relubrication interval (h) 50 and 60 Hz 8,000 Amount of oil (L) Table 13 - Lubrication oil used in sleeve bearings Lubricant FUCHS Renolin DTA 10 FUCHS Renolin DTA 15 Lubricant specification ISO VG 32 mineral oil with antifoaming agents and antioxidant additives ISO VG 32 mineral oil with antifoaming agents and antioxidant additives 16 W50 - Three-Phase Electric Motor
17 4.3 Maximum Radial and Axial Loads The tables below show the maximum allowable radial and axial loads for the W50 motors. The values of the maximum load were calculated considering a L10h bearing lifetime of 40,000 h. The maximum radial load values consider the axial load equal to zero and the maximum axial load values consider the radial load equal to zero. For applications involving simultaeneously axial and radial load, refer to WEG on bearing lifetime. To determine the maximum allowable radial and axial loads on the motor shaft the following factors must be considered: Regular operating conditions. Shaft material: AISI pole motors: parabolic torque load. 4, 6 and 8-pole motors: constant torque load. J J The values consider the application of a standard bearing for horizontal mounted motors Radial Loads The values shown in Tables 14 and 15 for the radial loads refer to the force applied to the center of the shaft end, L/2, and the end of the length of the shaft end,(figure 45). Radial Load - Roller Bearing Radial load - 50 Hz - Fr (kn) 4P 6P 8P L/2 L L/2 L L/2 L 315 H/G J/H L/K and 400 J/H L/K and 450 J/H Table 16 - Maximum allowable radial loads at 50 Hz for roller bearings. Radial load - 60 Hz - Fr (kn) 4P 6P 8P L/2 L L/2 L L/2 L 315 H/G J/H L/K and 400 J/H L/K and 450 J/H Table 17 - Maximum allowable radial loads at 60 Hz for roller bearings. Note: J J Roller bearings require a minimum radial load (preload) to ensure proper operation. This type of bearing is not recommended for applications with direct coupling Axial Loads Axial Loads for Horizontal Mounted Motors The values shown in Table 18 indicate the maximum allowable values for axial load on the shaft end for horizontal mounted motors fitted with ball bearing. L Figure 45 - Radial load applied to the shaft end. Radial Load - Ball Bearing Radial load - 50 Hz - Fr (kn) 2P 4P 6P 8P L/2 L L/2 L L/2 L L/2 L 315 H/G J/H L/K and 400 J/H L/K and 450 J/H Table 14 - Maximum allowable radial loads at 50 Hz for ball bearings. Radial load - 60 Hz - Fr (kn) 2P 4P 6P 8P L/2 L L/2 L L/2 L L/2 L 315 H/G J/H L/K and 400 J/H L/K and 450 J/H H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H Number of poles Momentary traction or compression (kn) Table 18 - Maximum allowable axial load for horizontal mounted motors. Table 15 - Maximum allowable radial loads at 60 Hz for ball bearings. W50 - Three-Phase Electric Motor 17
18 Axial Loads for Vertical mounted motors The values shown in Table 19 indicate the maximum allowable axial load on the shaft end for vertical mounted motors with normal thrust. The table considers DE bearing with angular contact. Number of poles Thrust (kn) 315 H/G 355 J/H 400 L/K and 400 J/H 450 L/K and 450 J/H 2 On request On request On request On request Momentary compression (kn) Table 19 - Maximum allowable axial load for vertical motors with normal thrust. 18 W50 - Three-Phase Electric Motor
19 5. Mounting Forms WEG Reference B3R(E) B3L(D) B3T B5R(E) B5L(D) B5T With feet With feet Without feet Without feet Shaft end Left Right Left Right Fixation Base or rails Base or rails FF flange FF flange WEG Reference B35R(E) B35L(D) B35T V5L(D) V5R(E) V5T V1L(D) With feet With feet With feet Without feet Shaft end Left Right Downwards Downwards Fixation Base or FF flange Base or FF flange Wall FF flange WEG Reference V6L(D) Details Mounting Details Mounting Details Mounting The standard motors are supplied in the B3 - mounting (see Figure 46), with the terminal box on the left side of the frame, looking at the non-drive end of the motor. The mounting designation for the W50 motors designation the IEC Different mounting can be supplied, as shown in table 20. V6R(E) V6T V15L(D) V15R(E) With feet With feet Shaft end Upwards Downwards Fixation Wall Wall or FF flange V15T Table 20 - Mountings. Figure 46 - B3R(E) mounting. W50 - Three-Phase Electric Motor 19
20 6. Degree of protection/bearing sealing/painting 6.1 Degree of Protection Standard IEC defines the degrees of protection of electrical equipment by means of the characteristic letters IP, followed by two characteristic numerals. The W50 motors are supplied with degree of protection IP55. 1 st charact. numeral 0 No-protected machine First characteristic numeral Definition 1 Machine protected against solid objects greater than 50 mm 2 Machine protected against solid objects greater than 12 mm 3 Machine protected against solid objects greater than 2,5 mm 4 Machine protected against solid objects greater than 1,0 mm 5 Dust-protected machine 6 Dust-tight machine Table 21 - First characteristic numeral indicates the degree of protection against the ingress of solid objects and accidental or inadvertent contact. 2 nd charact. numeral 0 No-protected machine Second characteristic numeral Definition 1 Machine protected against dripping water 2 Machine protected against dripping water when tilted up to 15º 3 Water falling as a spray at any angle up to 60º from the vertical 4 Water splashing against the machine from any direction 5 Water protected by nozzle against the enclosure from any direction 6 Water from heavy seas or water projected in powerful jets 7 Machine protected against the effects of immersion 8 Machine protected against the effects of continuous submersion 6.3 Painting The motors can be applied in severe industrial environments, in sheltered locations or outdoors, in the presence of SO 2, steams and solid contaminants, high humidity indexes, alkali and solvent splashes. The painting plan of the motors ensures a minimum of 1,000 hours of corrosion resistance in the test by salt spray chamber according to ASTM B and corrosion category C5 (I), according to ISO Internal Anti Corrosive Painting High humidity indexes can result in premature insulation system deterioration which is the main component that ensures the motor lifetime. Motors applied in environments with relative air humidity of about 95% do not require additional protections beyond the space heater to prevent moisture condensation inside the motor. However, for use in environments with humidity inexes above 95%, it is recommended to apply an epoxy coating on the internal parts of the motor, also known as tropicalized painting. 7. Voltage/Frequency According to IEC , the combinations of voltage and frequency variations are classified as Zone A or Zone B (see Figure 47). Voltage Zone A Table 22 - Second characteristic numeral indicates the degree of protection against the ingress of water in the machine. The W50 motors can also be supplied with higher degree of protection, as indicated below: IPW55 for increased degree of protection for outdoor installation. IP56 and IPW56 for increased degree of protection against water. IP65 and IPW65 for increased degree of protection against dust. J J IP66 and IPW66 for iincreased degree of protection against dust and water. Note: J J Letter W means that the motor can be operated in weathering. 6.2 Bearing Sealing The bearing sealing used on the endshields of the motor is the taconite labyrinth, which ensures the degree of protection IP55 for the motor frame according to IEC This sealing system protects the motor against the ingress of dust and water into the frame present in the environment. Standard features Frequency Zone B (external to Zone A) Figure 47 - Limits of voltage and frequency variations under operation. A motor must be capable of performing its main function continuously at Zone A, however it may not develop completely its performance characteristics at rated voltage and frequency showing few deviations. Temperature rises can be higher than those at rated voltage and frequency. A motor must be capable of performing its main function at Zone B, however it may present higher deviations than those of Zone A in reference to performance characteristics at rated voltage and frequency. Temperature rises can be higher than those at rated voltage and frequency and probably higher than those of Zone A. The extended operation at Zone B is not recommended. 20 W50 - Three-Phase Electric Motor
21 8. Environment Unless otherwise specified, the rated outputs shown in the electrical data tables in this catalogue refer to continuous duty, S1, according to IEC and under the following operating conditions: Ambient temperature range from -30 C to +40 C. J J Altitudes not exceeding masl. When the operating temperatures and altitudes differ from those indicated above, you must apply the derating factors indicated in table 21 to determine the useful power output (Pmax). Pmax = Pnom x Derating Factor. T ( C) Altitude (m) 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5, Table 23 - Derating factor considering altitude and ambient temperature. 9. Operation Characteristics During installation and any intervention on the machine, all recommendations for handling, lifting and maintenance must be observed. 9.1 Thermal Protection In order to monitor the operating condition of the motor, all the W50 motors are fitted with temperature sensors in the windings and on the bearings. In its standard version, the motors are fitted with two resistance temperature detector (Pt-100) with three wires per phase and one resistance temperature detector (Pt-100) per bearing (see Figure 48). Motors with sleeve bearing use Pt-100 with connection head (see Figure 49) fixed directly to the bearing. These devices generally have three wires, but they can be supplied with 2, 4, 6 (duplex) and 8 cables (duplex), and can be supplied with with ATEX or Ex certifications. Figure 48 - Pt-100. Figure 49 - Pt-100 with connection head. The W50 motors can also be supplied with other accessories: J J Thermostat: bimetallic thermal protectors with silver contacts, NC type (normally closed), which open when predetermined temperature rise is reached. When the activation temperature of the bimetal thermal protector decreases, the thermostat will return to its original position instantaneously allowing to close the contact and the consequent restart of the motor. The thermostats are series connected to the motor coil, and thus can be used for switching off the motor. A second set of bimetal thermal protectors can be used for the alarm, however in this case it must be connected to a specific alarm circuit. J J PTC Thermistors: increase their resistance very fast with temperature increase. The sudden change in resistance interrupts the current in PTC, activates an output relay, which turns off the main circuit. (see Figure 50). Figure 50 - PTC Thermistor. The thermistors have reduced size, do not have mechanical wear, and provide faster response when compared to other temperature sensors. However they do not allow continuous monitoring of the motor heating process. Thermistors with their electronic circuit controls ensure complete protection against overheating caused by phase-fault, overload, under/ overvoltages or frequent reversals of direction of rotation or on/ off cycles. 9.2 Operation with Frequency Inverter The W50 motors have a design suitable for applications with variable speed. The standard motor is designed for sine wave filter inverter operation, otherwise a motor with reinforced insulation must be supplied. All W50 motors fitted with rolling bearings have rigid shafts, avoiding the need of skipping frequencies on the inverter in the operating range; however, for speeds above the catalog limits, contact WEG. The W50 motors can be supplied for high speed version (up to 5,000 rpm), also on request Influence of the Frequency Inverter on Temperature Rise of the Motor The induction motor may present a higher temperature increase when fed by a frequency inverter, than when fed with sine wave voltage. This overtemperature rise is due to the combination of two factors: the increase of losses on the motor as a function of the harmonic components of the PWM voltage supplied by the inverter, and the reduction of the W50 - Three-Phase Electric Motor 21
22 effectiveness of the ventilation system when the self-ventilated motor operates at low frequencies. Basically the following solutions can be used to prevent the motor overheating : Reduction of the rated torque. J J Use of an independent ventilation system (forced ventilation). Criteria for Torque Reduction In order to maintain the temperature of the motors within acceptable levels when operating with frequency inverters and without forced ventilation, the load limits shown in Figure 51 must be observed (derating curve of the W50 motor). This torque reduction is a required solution when the motor drives a load with constant torque. In order to drive loads with quadratic torque, usually it is not necessary to apply any torque reduction factor. ( T R ) - Torque derating factor (p.u.) 1,05 1,00 0,95 0,90 0,85 0,80 0,75 0,70 0,65 0,60 0,55 0,50 0,45 0,40 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 (f/fn) - Operating frequency (p.u.) W50 ("T = 105 K) W50 ("T = 80 K) Figure 51 - Derating curve for motors driven by frequency inverter. Constant flux Constant V/f For more information on motors operated with frequency inverter, refer to the Technical Guide - Induction motors fed by PWM frequency inverters, which can be found at ecatalog.weg.net/files/wegnet/weg-induction-motors-fed- by-pwm-frequency-converters-technical-guide-028- technical-article-english.pdf. Forced Ventilation Kit Motors driven by frequency inverter at low speeds generally require an independent ventilation system. In these cases, the application of a forced ventilation kit ensures constant cooling of the motor throughout its speed range. The forced ventilation kit (see figure 52) comprises a 4-pole motor with independent power supply from the main motor, and it is not subject to its operating conditions. This ventilation kit uses a motor with natural cooling method (IC410 or IC40). Figure 52 - Detail of the assembly of the forced ventilation kit with cast iron air baffle. The supply voltages available for the forced ventilation kit of the W50 motors are listed in table 24. Supply voltage available for the forced ventilation kit (V) / / / / / / / / / / Table 24 - Supply voltages available for the forced ventilation kit. Note: J J Motors with forced ventilation kits present an increase of 3 db(a) in the noise level, without taking into account the noise produced by the frequency inverter. Since the global noise value depends on the inverter switching frequency, for more precise information, contact WEG. J J The use of the forced ventilation kit changes the motor length. In Section 12 is possible to check the motor length increase due to the use of the forced ventilation kit Common-Mode Voltages The common mode voltages occur when the sum of the voltages at the inverter output is different from zero. They are the main reason why currents flow through the motor bearings driven by static inverter. These currents wear the balls and the ball bearing races, reducing the bearing lifetime and causing premature failures. The W50 motors are supplied with shaft grounding brushes to prevent the current flow through the bearing and this avoid its premature failure, see item 2.4. Grounding Brush. 10. Installation Characteristics Some important aspects must be taken into account when dimensioning the installations of the W50 motors, which are described below Strength and Mass of the Motor Mechanical Support System (MSS) Regardless the mounting type or design of the motor Mechanical Support System (MSS), the assembly must be strong enough with relatively high mass. Several tools can be used to evaluate the strength of the foundation, such as experimental or numerical analysis. The base must present vibration levels less than 30% of the vibration measured on the motor in positions next to the 22 W50 - Three-Phase Electric Motor
23 fixation points in the horizontal, vertical and axial directions. The design of the base must also ensure that its the natural frequencies does not match the running frequency of the motor, also keeping a separation of ±5% from the natural frequency to twice and three times the speed frequency and to once and twice the power line frequency (60 e 120 Hz). Motors that operate with frequency inverter and variable mechanical speed must have the natural frequencies of the system removed from the inverter operating range, so that there are no natural frequencies of the whole system (motor + base + driven equipment) throughout this operating range. Metal fixtures of the motor must feature anchors securely fastened to the foundation anchor plate, avoiding the connection to the motor only with metal parts. Since structural steels absorb little external vibration and do not damp the motor vibrations, the global vibration and noise levels may increase. The base design must be robust and withstand the motor without significant deformation, taking into account the mass and stresses on the foundation informed by WEG on the motor data sheet Dimensional Control The dimensional control must be precise, with tolerance for flatness, parallelism and perpendicularity between the supports, avoiding soft foot or motor misalignment. The area of the motor footrests in the drive end and non-drive end must be identical. The foundation must also ensure 100% support of the DE and NDE foot. The foot flatness must be controlled for each motor. W50 motors can have flatness of the feet below mm according to IEEE 841 standard. Vertical mounted motors must be mounted on rectangular or round, solid, steel plates with a hole in the center for the shaft extension. The flange support surface must be machined, with threaded or throughout holes, but the fastening screws must be tightened with controlled torque on flat surfaces. The steel plate must be at least three times thicker than the machine flange (WEG recommend five times). This mounting base plate must be securely fastened to a solid and leveled surface (in compliance with IEC requirements.). Figure 53 - Dynapar B58N Encoder. J J Leine Linde ,024 ppr and 2,048 ppr (hollow shaft). It can also be supplied as an optional item and offers good precision (see Figure 54). Figure 54 - Leine Linde 861 Encoder. Other encoder models can be supplied on request. Note: J J Mounted on the non-drive end of the motor and directly coupled to the shaft extension, the use of this device increases the motor length, which varies according to the encoder Protection Against Voltage Surge The terminal box of the motor of the W50 high-voltage line can be equipped with an surge arrester per phase (see Figure 55). These components are classified according to the following voltage classes: 3 kv, 6 kv, 9 kv or 12 kv. 11. Special Accessories Some special accessories can be installed on the W50 motors for specific functions, such as speed control, temperature monitoring, and protection against oscillations of the power line or lightning discharges Encoder For precise speed and shaft position control in critical applications, the W50 motors can be supplied with an encoder. WEG recommends the use of the following encoders: J J Dynapar- series B58N- 1,024 ppr and 2,048 ppr (hollow shaft). This encoder is easy to mount and ensures good precision (see Figure 53). Figure 55 - Surge arrester. Besides the surge arrester, the high-voltage motors also have a surge capacitor per phase as special component (see Figure 56). These devices are installed in the main terminal box and their application recommended in systems potentially subject to voltage peaks during switching operations or lightning discharges. The surge capacitors are installed in a stainless steel enclosure and have the following features: Capacitance μf Rate voltage - up to 7.2 kv Voltage class - 15 kv W50 - Three-Phase Electric Motor 23
24 Figure 56 - Surge capacitor used in the W50 line Leveling Screw In order to ensure perfect alignment between the driven machine and the motor, WEG supplies the leveling screws set as an accessory. These components must be used only during the motor installation and must be removed after the shims are placed between the foundation and the machine Non-Reverse Ratchet Some applications do not allow the inversion of direction of rotation. In order to prevent this reversal, the W50 motors must be fitted with the non-reverse ratchet (see Figure 57). Figure 57 - Non-reverse ratchet Thermometer In order to monitor the bearing temperature, for both rolling bearing and sleeve bearing, the motors can be fitted with thermometers. On the rolling bearings, one thermometer can be installed on each endshield, and for sleeve bearings, thermometers can be installed on the bearing shell or oil tank. Figure 59 - Intermediate base. If the replacement a motor with a frame size (shaft end height) immediately above the output power is required, we supply motors on the frame above with a dedicated design, keeping the mass, length and noise similar to the lower frame size. If necessary to use the height of two frames above (for example, change the 315 frame by the 400 frame), the motors can be supplied with intermediate steel base. In this case, the upper part of the base features the fixation drilling of the standard motor in the required power, and the lower base the fixation drilling of two frames immediately above Automatic Lubricator The automatic lubricator available for the W50 motors reduces the motor maintenance, especially in applications in which the motor is in a place with difficult access and high ambient temperature or speeds. The lubricator, when supplied with the motor, has polyurea based grease and it is configured for the lubrication intervals specified on the motor nameplate. The grease canister must be replaced with the same grease or compatible grease in order to ensure smooth motor operation.. The grease outlet works by the same way of the motors with grease nipple. Easily-accessible, the lubricator can be mounted on the motor sides or endshields (see Figure 60 and 61). Figure 60 - Lubricator located on the sides. Figure 58 - Thermometers with sights located on the sides Interchangeability Solutions With the technological progress, machines are increasingly smaller and more efficient, which consequently results in interchangeability problems, especially for older motors or from different manufacturers. In order to solve this problem, the W50 motors can be supplied with an intermediate base (see Figure 59), or also with dimensional variations, especially on feet and frame. Figure 61 - Lubricator located on the endshields. 24 W50 - Three-Phase Electric Motor
25 12. Construction Features 315 H/G 355 J/H 400 L/K 400 J/H 450 L/K 450 J/H Mechanical features Mounting B3R(E) Material Cast iron FC-200 Degree of protection IP55 Grounding Double grounding (1 terminal box + 1 frame) Cooling method TEFC Fan Material 2P 4P - 12P Cast iron FC-200 Fan cover Cast iron FC-200 (rolling bearings) - Steel (sleeve bearings) Material Endshields Cast Iron FC-200 Drain plug Automatic drain plug Shielded/clearance DE C3 Shielded/clearance NDE C3 Locating bearing Fixed on DE with external and internal bearing cap and preload spring NDE Bearing 2P Drive end 4P - 12P Non-drive end 2P P - 12P Axial clearence 4 mm 4 mm Locating bearing Located both bearings Sleeve bearings Drive end 2P P - 12P Non-drive end Bearing seal Type of grease Lubrification Grease fitting 2P P - 12P Taconite Labyrinth Mobil Polyrex EM With grease fitting Terminal box Material Cast Iron FC-200 Main (low voltage) 2 x M63 x x M80 x 1.5 Lead inlet Main (high voltage) M63 x 1.5 Size Additional 3 x M20 x 1.5 Plug Plastic threaded plug Material AISI 4140 Shaft 2P M20 Threaded hole 4P -12P M24 Shaft key C key Vibration level Grade A Balancing without/half/full key With 1/2 key Nameplate Material Laser printed Stainless Steel AISI 304 Painting Type 214P Color RAL 5009 Electrical features Design Low voltage, up to 500 HP - Design N / High voltage - not applicable Voltage Single speed 380 V a 6600 V Winding Space heater Impregnation Low voltage - Resin continuous flow / High voltage - VPI Insulation class F (DT 80 K) 110/220 V - 220/440 V Service factor 1.00 Ambient temperature Maximum +40 C Minimum -20 C Starting method DOL Rotor Die cast Aluminium (450 L/K 8 poles with copper bar) Copper bars Thermal protection PT100-3-wires (2 per phase) W50 - Three-Phase Electric Motor 25
26 13. Optional Features 1) 2) 315 H/G 355 J/H 400 L/K 400 J/H 450 L/K 450 J/H Mechanical optionals Terminal box type Cast iron SD SD SD SD SD SD Steel O O O O O O Terminal block BMC 3 terminals - KWHV-M16 SD SD SD SD SD SD BMC 6 terminals - KWLV-M16 SD SD SD SD SD SD Connection bolt (low and high voltage) S S S S S S Flying leads (low voltage) S S S S S S Cable gland Without cable gland SD SD SD SD SD SD Plastic O O O O O O Brass O O O O O O Stainless steel O O O O O O Flange Without flange SD SD SD SD SD SD Flange FF O O O O O O Fan Cast iron SD SD SD SD SD SD Aluminium S S S S S S Bronze S S S S S S Steel (carbon or stainless steel) S S S S S S Drive end bearing type Ball bearing SD SD SD SD SD SD Rolling bearing NU design (4p - 12p) O O O O O O Sleeve bearing O O O O O O Non-drive end bearing type Ball bearing 3) SD SD SD SD SD SD Sleeve bearing O O O O O O Angular contact ball bearing S S S S S S Insulated drive endshield hub Non isolated SD SD SD SD SD SD Isolated bearing S S S S S S Isolated end shield S S S S S S Insulated non-drive endshield hub Isolated end shield SD SD SD SD SD SD Isolated bearing S S S S S S Non isolated S S S S S S Bearing cap Bearing cap SD SD SD SD SD SD Drive end bearing seal Taconite labyrinth SD SD SD SD SD SD INPRO/SEAL O O O O O O Taconite labyrinth with slinger O O O O O O Mechanical seal O O O O O O Joint seal Loctite 5923 (Permatex) on joints O O O O O O Shaft Material: AISI 4140 SD SD SD SD SD SD Shaft locking device SD SD SD SD SD SD Threaded center hole (shaft) SD SD SD SD SD SD Second shaft end S S S S S S 26 W50 - Three-Phase Electric Motor
27 Notes: 1) Other optional features, on request; 2) Some combinations of optional features are not allowed - then contact WEG; 3) Vertical motors are supplied with angular contact ball bearing, except frames 315 H/G (4p - 12p). SD - Standard O - Optional S - Special Balance type Normal balance with 1/2 key (for 4 poles on) SD SD SD SD SD SD Special balance with 1/2 key (for 2 poles) SD SD SD SD SD SD Key C key SD SD SD SD SD SD B key S S S S S S Vibration level Grade A SD SD SD SD SD SD Grade B O O O O O O Lubrication Mobil Polyrex EM SD SD SD SD SD SD Aeroshell 7 S S S S S S Isoflex NBU 15 S S S S S S Oil mist S S S S S S Grease fitting Carbon steel grease fitting SD SD SD SD SD SD Threaded grease fitting NPT 1/4" S S S S S S Grease fiting able to oil mist S S S S S S Grease outlet Grease outlet by plastic slide valve SD SD SD SD SD SD Grease outlet through endshield S S S S S S Drain Automatic drain plug SD SD SD SD SD SD Threaded drain plug (closed) O O O O O O Stainless stell threaded drain plug (closed) O O O O O O Threaded T-type drain plug (automatic) O O O O O O Closed plastic drain plug S S S S S S Degree of protection IP55 SD SD SD SD SD SD IP56 O O O O O O IP65 O O O O O O IP66 O O O O O O IPW55 O O O O O O IPW56 O O O O O O IPW65 O O O O O O IPW66 O O O O O O 214P - ISO C5 (I and M) durability class High - Indicated for aggressive sheltered and non-sheltered environment. Industrial application that allows SO2, steams, solid contaminant, high humidity and alkali and solvent sprinkles presence 212E - ISO C5 (I and M) durability class High - Indicated for marine aggressive environment or marine industrial environment, sheltered allowing high humidity and alkali and solvent sprinkles presence. Indicate to pulp and paper, mining and chemical industrial applications 212P - ISO C5 (I and M) durability class High - Indicated for marine aggressive environment or marine industrial environment, sheltered or nonsheltered, allowing high humidity presence. Indicate to pulp and paper, mining and chemical industrial applications 213E - ISO C5 (I and M) durability class High - Indicated for marine aggressive environment or marine industrial environment, sheltered, allowing high humidity presence. Indicated to offshore ambient 216P - ISO C5 (I and M) durability class High - Indicated for marine environments, with salinity, containing or not sulfur-derivated gases. Operating temperature: 15 C to 80 C. Indicated for fixed and mobile platforms, exploration and production vessels, submerged structures, piers, single mooring buoys and others Painting plan SD SD SD SD SD SD O O O O O O O O O O O O O O O O O O O O O O O O Internal tropicalized painting (epoxi) O O O O O O W50 - Three-Phase Electric Motor 27
28 13. Optional Features 1) 2) Other mechanical optionals Ventilated bearing SD SD SD SD SD SD Drip cover O O O O O O Rubber slinger S S S S S S Electrical optionals Winding protection 3-wire Pt-100, 2 per phase (alarm) SD SD SD SD SD SD 3-wire Pt-100, 2 per phase (tripping ) SD SD SD SD SD SD 3-wire Pt-100, 2 per phase, calibrated (alarm) O O O O O O 3-wire Pt-100, 2 per phase, calibrated (tripping) O O O O O O PTC thermistor C (alarm) O O O O O O PTC thermistor C (tripping) O O O O O O Bimetal thermal protector C (alarm) O O O O O O Bimetal thermal protector C (tripping) O O O O O O Bearing thermal protection 3-wire Pt drive end / non drive end SD SD SD SD SD SD 3-wire calibrated Pt drive end / non drive end O O O O O O Two 3-wire Pt drive end / non drive end O O O O O O Two 3-wire calibrated Pt drive end / non drive end O O O O O O Bimetal thermal protector - drive end / non-drive end O O O O O O Space heaters / V SD SD SD SD SD SD V O O O O O O Insulation class F SD SD SD SD SD SD H S S S S S S Forced ventilation kit Forced ventilation kit prepared for encoder assembly O O O O O O Encoder Without encoder SD SD SD SD SD SD Dynapar B58N O O O O O O Leine&Linde XH O O O O O O Leine&Linde XH O O O O O O Grounding brush kit Drive end grounding brush O O O O O O Drive end SGR grounding brush O O O O O O Notes: 1) Other optional features, on request; 2) Some combinations of optional features are not allowed - then contact WEG; SD - Standard O - Optional S - Special 28 W50 - Three-Phase Electric Motor
29 14. Electrical Data 14.1 W50 - Low Voltage 400 V Full Locked Locked Breakdown Inertia J Allowable locked Output load rotor rotor rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) II poles H/G H/G H/G H/G J/H J/H J/H J/H J/H J/H IV poles H/G H/G H/G H/G J/H J/H J/H J/H J/H L/K L/K L/K J/H* VI poles H/G H/G H/G J/H J/H J/H J/H J/H J/H J/H L/K J/H J/H* J/H* VIII poles H/G H/G J/H J/H J/H L/K L/K J/H J/H J/H J/H J/H * Temperature rise ΔT 105 K. W50 - Three-Phase Electric Motor 29
30 14. Electrical Data 14.1 W50 - Low Voltage 400 V Full Locked Locked Breakdown Inertia J Allowable locked Output load rotor rotor rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) X poles H/G H/G H/G J/H J/H J/H J/H J/H L/K L/K L/K J/H J/H* L/K J/H J/H* XII poles J/H J/H L/K L/K J/H L/K L/K J/H J/H J/H* W50 - High Voltage kv to 5.0 kv V Full Locked Locked Break- Allowable locked Output load rotor rotor -down Inertia J rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) II poles H/G H/G H/G H/G H/G H/G J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H * Temperature rise ΔT 105 K. 30 W50 - Three-Phase Electric Motor
31 14. Electrical Data 14.2 W50 - High Voltage kv to 5.0 kv V Full Locked Locked Breakdown Inertia J Allowable locked Output load rotor rotor rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) IV poles H/G H/G H/G H/G H/G H/G H/G H/G J/H J/H J/H L/K J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H VI poles H/G H/G H/G H/G H/G H/G H/G J/H J/H J/H J/H J/H L/K J/H J/H L/K L/K L/K J/H J/H J/H J/H J/H VIII poles H/G H/G H/G J/H J/H J/H L/K J/H J/H J/H L/K L/K J/H W50 - Three-Phase Electric Motor 31
32 14. Electrical Data 14.2 W50 - High Voltage kv to 5.0 kv V Full Locked Locked Breakdown Inertia J Allowable locked Output load rotor rotor rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) X poles J/H J/H J/H J/H J/H J/H L/K L/K L/K J/H J/H L/K L/K L/K L/K XII poles L/K L/K L/K L/K L/K L/K L/K L/K L/K L/K W50 - High Voltage kv to 6.6 kv V Full Locked Locked Break- Allowable locked Output load rotor rotor -down Inertia J rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) II poles H/G H/G H/G J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H W50 - Three-Phase Electric Motor
33 14. Electrical Data 14.3 W50 - High Voltage kv to 6.6 kv V Full Locked Locked Break- Allowable locked Output load rotor rotor -down Inertia J rotor time (s) Weight Sound % of full load Full Rated torque current torque torque (kgm2) (kg) db(a) speed Efficiency Power factor load (Nm) Il/In Tl/Tn Tb/Tn current kw HP Hot Cold (rpm) In (A) IV poles H/G H/G H/G H/G H/G H/G J/H J/H J/H J/H J/H J/H J/H J/H L/K L/K L/K L/K J/H J/H J/H* VI poles J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H L/K L/K J/H J/H J/H J/H J/H* VIII poles J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H J/H* * Temperature rise ΔT 105 K. W50 - Three-Phase Electric Motor 33
34 15. Mechanical Data 15.1 s 315 H/G to 450 J/H 315 H/G 355 J/H 400 L/K 400 J/H 450 L/K 450 J/H N poles A AA AB AC AD AE B BA BB BC BD C Shaft end D E ES N F G GD / /6/ / /6/ / /6/ / /6/ / /6/ / /6/ H/G 355 J/H 400 L/K 400 J/H 450 L/K 450 J/H N poles H HA HC HD HH HK K K' L LL LM d1 S1 S2 DE Bearings M20 x C C M63 x 1.5 4/6/ M24 x C C M20 x C C /6/ M24 x C C M20 x C C3 4/6/ M24 x C C x M20 x M20 x C C3 2 x M80 x 2 4/6/ M24 x C C M20 x C C3 4/6/ M24 x C C M20 x C C3 4/6/ M24 x C C3 NDE 34 W50 - Three-Phase Electric Motor
35 8x Flange FF T ØS Flange C M N P S T N holes 315 H/G FF J/H FF L/K FF J/H L/K FF J/H ØM 22.5 ØN ØP C Utilization of sleeve bearing, forced ventilation and drip cover increases the total length of the motor. This additional length can be seen in the tables below External Motor Dimensions with Steel Plate Terminal Box Designation Steel 1 and Steel 2 Steel 11 AD HD AD HD 315 H/G J/H L/K 400 J/H L/K 450 J/H External Motor Dimensions with Sleeve Bearing N poles C LB 315 H/G J/H L/K J/H L/K J/H LB C W50 - Three-Phase Electric Motor 35
36 15.5 External Motor Dimensions with Forced Ventilation N poles L H/G J/H L/K J/H L/K J/H LC L 15.6 Drip Cover Height 315 H/G 355 J/H 400 L/K 400 J/H 450 L/K 450 J/H CH [mm] CH 36 W50 - Three-Phase Electric Motor
37 16. Terminal Boxes The terminal boxes can be manufactured in cast iron FC-200, the same material used in the frame and endshields, or manufactured in steel plate. Below see the external dimensionals and some technical features Cast Iron Terminal Boxes Iron 01 Technical data Maximum quantity of leads 1 per phase Entry plates for leads designation Type 01 Internal volume 51 dm³ Connecting bolt M16 x 2 Tightening torque of the terminals 30 Nm Grounding terminal Internal Approximate weight 75 kg Degree of protection IP66 General data Minimum teminal box thickness 7 mm Rotate in steps of 90 Yes W50 - Three-Phase Electric Motor 37
38 Iron 02 Maximum quantity of leads Technical data 1 per phase Entry plates for leads designation Type 02 Internal volume 64.7 dm³ Connecting bolt M16 x 2 Tightening torque of the terminals Grounding terminal Approximate weight Degree of protection Minimum teminal box thickness Rotate in steps of 90 Pressure relief device in the back of the terminal box in case of short circuit General data 30 Nm Internal 75 kg IP66 7 mm Yes 38 W50 - Three-Phase Electric Motor
39 16.2 Steel Plate Terminal Boxes Steel 01 1) 1) Note: 1) Dimensions of the terminal box cover. Technical data Maximum quantity of leads 1 per phase Entry plates for leads designation Type 01 Internal volume dm³ Connecting bolt M16 x 2 Tightening torque of the terminals 30 Nm Grounding terminal Internal or external Approximate weight 95 kg Degree of protection IP66 General data Minimum teminal box thickness 3.35 mm Rotate in steps of 90 Yes With eyebolts 4 eyebolts W50 - Three-Phase Electric Motor 39
40 Steel 02 Note: 1) Dimensions of the terminal box cover. Maximum quantity of leads Technical data 1 per phase Entry plates for leads designation Type 01 Internal volume dm³ Connecting bolt M16 x 2 Tightening torque of the terminals Grounding terminal Approximate weight Degree of protection Minimum teminal box thickness Rotate in steps of 90 With eyebolts Pressure relief device in the back of the terminal box in case of short circuit General data 30 Nm Internal or external 90 kg IP mm Yes 4 eyebolts Yes 40 W50 - Three-Phase Electric Motor
41 17. Packaging W50 motors in frames 315 to 400 are packaged in wooden pallets (see figure 62), following the dimensions, weights and volumes opposite. 1) 315 H/G External height (m) External width (m) Note: 1) Applicable for motor with side terminal boxes. External lenght (m) Weight (kg) Volume (m³) J/H L/K J/H Figure 62 - Wooden pallet. For frame 450, the motors are packaged in steel pallets. Dimensions, weights and volumes are in tables opposite. 1) 450 L/K 450 J/H External height (m) External width (m) External lenght (m) Weight (kg) Volume (m³) Note: 1) Applicable for motor with side terminal boxes. Figure 63 - Steel crates. W50 - Three-Phase Electric Motor 41
42 18. Spare Parts Grease nipple Fan External bearing cap N.D.E. endshield Internal bearing cap N.D.E. bearing Balancing disk Eyebolt Round steel screen Internal baffle (only for II poles) Grease relief plug Fan cover Labirinth seal Drain 42 W50 - Three-Phase Electric Motor
43 Auxiliar terminal box Main terminal box Main terminal box support Eyebolt Wound stator D.E. bearing D.E. endshield External bearing cap Grease nipple Labirinth seal Air baffle Rotor Shaft Key Grounding Drain Grease relief plug W50 - Three-Phase Electric Motor 43
44 WEG Worldwide Operations ARGENTINA WEG EQUIPAMIENTOS ELECTRICOS San Francisco - Cordoba Phone: [email protected] WEG PINTURAS - Pulverlux Buenos Aires Phone: [email protected] AUSTRALIA WEG AUSTRALIA Victoria Phone: [email protected] AUSTRIA WATT DRIVE - WEG Group Markt Piesting - Vienna Phone: [email protected] BELGIUM WEG BENELUX Nivelles - Belgium Phone: [email protected] BRAZIL WEG EQUIPAMENTOS ELÉTRICOS Jaraguá do Sul - Santa Catarina Phone: [email protected] CHILE WEG CHILE Santiago Phone: [email protected] CHINA WEG NANTONG Nantong - Jiangsu Phone: [email protected] COLOMBIA WEG COLOMBIA Bogotá Phone: [email protected] FRANCE WEG FRANCE Saint Quentin Fallavier - Lyon Phone: [email protected] GERMANY WEG GERMANY Kerpen - North Rhine Westphalia Phone: [email protected] GHANA ZEST ELECTRIC GHANA WEG Group Accra Phone: [email protected] INDIA WEG ELECTRIC INDIA Bangalore - Karnataka Phone: [email protected] WEG INDUSTRIES INDIA Hosur - Tamil Nadu Phone: [email protected] ITALY WEG ITALIA Cinisello Balsamo - Milano Phone: [email protected] JAPAN WEG ELECTRIC MOTORS JAPAN Yokohama City - Kanagawa Phone: [email protected] MALAYSIA WATT EURO-DRIVE - WEG Group Shah Alam, Selangor Phone: [email protected] MEXICO WEG MEXICO Huehuetoca Phone: [email protected] VOLTRAN - WEG Group Tizayuca - Hidalgo Phone: NETHERLANDS WEG NETHERLANDS Oldenzaal - Overijssel Phone: [email protected] PERU WEG PERU Lima Phone: [email protected] PORTUGAL WEG EURO Maia - Porto Phone: [email protected] RUSSIA and CIS WEG ELECTRIC CIS Saint Petersburg Phone: [email protected] SOUTH AFRICA ZEST ELECTRIC MOTORS WEG Group Johannesburg Phone: [email protected] SPAIN WEG IBERIA Madrid Phone: [email protected] SINGAPORE WEG SINGAPORE Singapore Phone: [email protected] SCANDINAVIA WEG SCANDINAVIA Kungsbacka - Sweden Phone: [email protected] UK WEG ELECTRIC MOTORS U.K. Redditch - Worcestershire Phone: [email protected] UNITED ARAB EMIRATES WEG MIDDLE EAST Dubai Phone: [email protected] USA WEG ELECTRIC Duluth - Georgia Phone: [email protected] ELECTRIC MACHINERY WEG Group Minneapolis - Minnesota Phone: VENEZUELA WEG INDUSTRIAS VENEZUELA Valencia - Carabobo Phone: [email protected] For those countries where there is not a WEG own operation, find our local distributor at WEG Group - Motors Business Unit Jaraguá do Sul - SC - Brazil Phone: [email protected] Cod: Rev: 06 Date (m/y): 05/2015 The values shown are subject to change without prior notice.
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
A S Y N C H R O N O U S M O T O R S
ASYNCHRONOUS M O T O R S S E R I E S INDAR ASYNCHRONOUS MOTORS S E R I E S WHO WE ARE Indar Electric s trajectory is endorsed by the construction of thousands of motors for the different industrial sectors.
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved
SOUTH AUSTRALIA HEAD OFFICE (Accounts / Payments) 34-36 Kinkaid Avenue NORTH PLYMPTON SA 5037 Ph: (08) 8295 5566 Fax: (08) 8295 5533 VICTORIA 23 James Street CLAYTON SOUTH VIC 3169 Ph: (03) 9544 2324 Fax:
THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES
THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES IE2 FRAMES 80 355 0,75 315kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in this catalogue satisfy the essential
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
We will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Water-cooled three-phase asynchronous motors. Type series K21B / K23B
Water-cooled three-phase asynchronous motors Type series K21B / K23B Contents Page Introduction 3 Standards and regulations 4 Design version 4 Water cooling 5 Degree of protection 5 Drain holes 5 Vibration
TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...
SYNCHRONOUS MOTORS TABLE OF CONTENTS Motores Síncronos INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...11 CONSTRUCTIVE CHARACTERISTICS...12
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
S Y N C H R O N O U S G E N E R A T O R S
S E R I E S SYNCHRONOUS G E N E R A T O R S INDAR SYNCHRONOUS GENERATORS S E R I E S BZK INDAR ELECTRIC INDAR, EXPERIENCE AND COOPERATION INDAR Electric develops and manufactures electrical rotating machines
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
Solving VFD-sourced Bearing Current Problems in AC Motors.
Solving VFD-sourced Bearing Current Problems in AC Motors. The 2 main sources of motor shaft voltage are: 1. Asymmetric Motor construction The stator and rotor magnetic circuits within the motor itself
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Standard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) [email protected]
Generators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
Torque motors. direct drive technology
Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly
Installation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
AC Replacement for DC Mill-Duty Motors
AC Replacement for DC Mill-Duty Motors This article is available online at www.aist.org for 30 days following publication. For many years, DC mill auxiliary motors for steel mill applications such as screwdowns,
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Siemens AG 2009. Spindle solutions. Spindle motors and motor spindles for every requirement. Brochure October 2009. Motors. Answers for industry.
Spindle solutions Spindle motors and motor spindles for every requirement Brochure October 2009 Motors Answers for industry. The right spindle solution for any task The function, performance and accuracy
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
X8 X13A X14 - AC Gearless
This manual is to be given to the end user X8 X13A X14 - AC Gearless Installation and maintenance THIS MANUAL MUST REMAINS WITH THE MACHINE. THE TABLE (page 4) MUST BE SUPPLEMENTED TO ATTEST GOOD REALIZATION
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig
Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
Operataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
MICRO HYDRO POWER GENERATING EQUIPMENT
MICRO HYDRO POWER GENERATING EQUIPMENT TOSHIBA TOSHIBA ENGINEERING In general, specifications of hydroelectric power system vary depending upon the installation location. The hydro turbine and generator
Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers
Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers Topic: Noise Q: Is there a way to predict/calculate noise on a ball screw? A: No, there is no way to calculate the noise of
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Turbo generators Best quality for thermal power plants
Turbo generators Best quality for thermal power plants www.andritz.com ANDRITZ HYDRO Turbo generators International technology Group ANDRITZ is a globally leading supplier of plants, equipment, and services
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,
Réf. 1744-4.33 / c - 5.97 LSK
Réf. 1744-4.33 / c - 5.97 3 26 1 LSK Installation and maintenance CONTENTS PAGES 1. - TOOLS... 3 2. - HANDLING... 3 PAGES 9. - DISMANTLING... 6 9.1 - Procedure... 6 9.2 - Dismantling the armature only...
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Series description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
Motor Specifications. Nameplate
Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower
IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax
IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist
System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
3097 en - 2013.06 / e. This manual is to be given to the end user POULIBLOC 2000-3000. Shaft mount reducer. Installation
097 en - 0.06 / e 8 en This manual is to be given to the end user POULIBLOC 000-000 Installation LEOY-SOME ISTALLATIO POULIBLOC 000-000 097 en - 0.06 / e This document complements the general instructions
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Roller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.
SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior
No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
SF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4
Medium voltage Electric motors ELECTRICAL MACHINES UNIBOX & MS4 Index - Medium Voltage Motor Series PRODUCT TOPIC ACTOM our company history Who is ACTOM PG UNIBOX Bearings and lubrication 7 UNIBOX Ventilation
SECTION 16461 DRY-TYPE TRANSFORMERS
SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any
ZKL Bearings for Railway Rolling Stock
2 ZKL Bearings for Railway Rolling Stock ZKL Bearings for Railway Rolling Stock Railway industry is a very prospective sector worldwide and therefore ZKL pays particular attention to bearings for railway
LC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
Italvibras USA. Operator s Manual
Italvibras USA Industrial Electric Vibrators Model Operator s Manual Table of Contents Section Title Page Tables and Figures Index.................................Below Introduction.................................................1
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
AC Submersible Pump Motors Installation & Operating Manual
AC Submersible Pump Motors Installation & Operating Manual 2/12 Any trademarks used in this manual are the property of their respective owners. Table of Contents Section 1 General Information... Overview...
Manual for High Voltage Process Performance Motors ABB
Manual for High Voltage Process Performance Motors ABB Safety Instructions AMA, AMB, AMG, AMH, AMI, AMK, AMZ, HXR, M3BM, M3GM 1. General 2. Intended use General safety regulations, specific agreements
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
WEg Mod Shop Modification Program, Special Features & Spare Parts
INDEX & ACCESSORIES WEg Mod Shop Modification Program, Special Features & Spare Parts V-RING NON-DRIVE ENDSHIELD BEARING STATOR BEARING V-RING FAN COVER FAN FRAME ROTOR DRIVE ENDSHIELD TERMINAL BOX WEg
Regal Beloit AC Motors
Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service
Dry Pit Solids Handling Pumps
Dry Pit Solids Handling Pumps A Time-Tested Leader Chicago Pump Dry Pit Solids Handling Pumps have an established reputation of efficiency, long life and reliable operation First in: Quality 3Reliability
Bearing Failure: Causes and Cures
Bearing Failure: Causes and Cures bearing.ppt Page 1 Excessive loads usually cause premature fatigue. Tight fits, brinelling and improper preloading can also bring about early fatigue failure. The solution