Paricon Technologies



Similar documents
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION

HPM-5 Performance Testing

Agilent Improved Method for Characterizing and Modeling Gigabit Flex-Circuit Based Interconnects. White Paper

S-PARAMETER MEASUREMENTS OF MEMS SWITCHES

High Speed Characterization Report

The Design & Test of Broadband Launches up to 50 GHz on Thin & Thick Substrates

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

Time and Frequency Domain Analysis for Right Angle Corners on Printed Circuit Board Traces

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

R3765/67 CG Network Analyzer

Ultra640 SCSI Measured Data from Cables & Backplanes

PRODUCT SPECIFICATION

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

Experiment 7: Familiarization with the Network Analyzer

Probes and Setup for Measuring Power-Plane Impedances with Vector Network Analyzer

A Comparison of Measurement Uncertainty in Vector Network Analyzers and Time Domain Reflectometers. White Paper

ELECTRICAL CHARACTERISATION OF SMA CONNECTORS FOR CRYOGENIC AMPLIFIERS. Carmen Diez Juan Daniel Gallego Isaac López Rafael García.

ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS. Carmen Diez Rafael García Juan Daniel Gallego.

Measuring Parasitic Capacitance and Inductance Using TDR

Agilent Stripline TRL Calibration Fixtures for 10-Gigabit Interconnect Analysis. White Paper

Extending Rigid-Flex Printed Circuits to RF Frequencies

Twinax Intra Pair Skew Comparison Report Various Lengths and Competitors Tested

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

2. The Vector Network Analyzer

Agilent AN In-Fixture Measurements Using Vector Network Analyzers

Measurement of Inductor Q with the MSA Sam Wetterlin 3/31/11. Equation 1 Determining Resonant Q from Inductor Q and Capacitor Q

How to make a Quick Turn PCB that modern RF parts will actually fit on!

The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements

Cable Impedance and Structural Return Loss Measurement Methodologies

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

Connector Launch Design Guide

Techniques for precise cable and antenna measurements in the field

USB 3.1 Channel Loss Budgets

Capacitor Self-Resonance

MEASUREMENT OF CRYOGENIC PERFORMANCE OF 4-8 GHz PAMTECH ISOLATORS S/N Juan Daniel Gallego Isaac López Fernández Carmen Diez González

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

AMERICAN NATIONAL STANDARD

IC-EMC v2 Application Note. A model of the Bulk Current Injection Probe

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

spinner Measurement & Calibration equipment for network analyzers

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Comprehensive Analysis of Flexible Circuit Materials Performance in Frequency and Time Domains

PCB Design Conference - East Keynote Address EMC ASPECTS OF FUTURE HIGH SPEED DIGITAL DESIGNS

Agilent Measuring Noninsertable Devices

Balun Parameter Definitions & Measurement May 2004

Keysight E5063A ENA Series PCB Analyzer

RC Scrub R. High Performance Test Socket Systems for Micro Lead Frame Packages

Using Simple Calibration Load Models to Improve Accuracy of Vector Network Analyzer Measurements

Measurements in 75 Ω Coaxial Transmission Lines

Agilent Test Solutions for Multiport and Balanced Devices

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Copyright 1996 IEEE. Reprinted from IEEE MTT-S International Microwave Symposium 1996

Agilent 8753ET/8753ES Network Analyzers

MOHR Application Note: TDR vs. FDR: Distance-to-Fault

Agilent Time Domain Analysis Using a Network Analyzer

Printed Circuit Board (PCB) Test Methodology

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

VJ 6040 Mobile Digital TV UHF Antenna Evaluation Board

Solving Difficult Cable Measurements

RClamp0522PA RClamp0524PA

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Experimental Analysis of Common Mode Currents on Fibre Channel Cable Shields due to Skew Imbalance of Differential Signals Operating at 1.

Current Probes, More Useful Than You Think

75 Ω Transmission System

a 1 a 2 2 Port b 2 b 1 Multi-Port Handset Switch S-Parameters Application Note AN20 Seven-Port S-Parameter Definition Introduction Summary:

Impedance 50 (75 connectors via adapters)

Times Microwave Systems Hermetically Sealed Assemblies

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Managing Connector and Cable Assembly Performance for USB SuperSpeed

MAURY. VNA Calibration Kits, Microwave Components & Adapters. Calibrate With Confidence IN THIS CATALOG:

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

AVR2006: Design and characterization of the Radio Controller Board's 2.4GHz PCB Antenna. Application Note. Features.

1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

PRODUCTS SPECIFICATION

Perturbation of near-field scan from connected cables Sørensen, Morten; Franek, Ondrej; Pedersen, Gert F.; Baltsen, Knud A.

Measurement & Modeling Device Characterization Solutions

Agilent PN In-fixture Microstrip Device Measurements Using TRL* Calibration. Product Note

2/20/ Transmission Lines and Waveguides.doc 1/3. and Waveguides. Transmission Line A two conductor structure that can support a TEM wave.

For MRI Scanners, Equipment, and MRI Body Coils

KVPX CONNECTOR SERIES HIGH SPEED SIGNAL INTEGRITY REPORT

Techniques for Precise Cable and Antenna Measurements in the Field

Automotive Ethernet Compliance Testing

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Cable Analysis and Fault Detection using the Bode 100

Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

Agilent Ultra-Low Impedance Measurements Using 2-Port Measurements. Application Note

3.3 Calibration standards

Index mm Connector Series mm Connectors (50 GHz)... Page. Interface Standards Specifications Connector Numbers...

What is Characteristic Impedance?

How To Measure Power Loss On A Cable Or Antenna System

Transcription:

Paricon Technologies Flex connector Measurement Results prepared by Gert Hohenwarter 1/24/07 1

Table of Contents TABLE OF CONTENTS... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 4 Setup... 4 MEASUREMENTS... 6 Time domain... 6 Frequency domain... 10 2

Objective The objective of these measurements is to determine the RF performance of a Paricon Technologies flex connector. Measurements in both frequency and time domain form the basis for the evaluation. Parameters to be determined are differential insertion loss and return loss in the range from 50 MHz to 20 GHz. Methodology Frequency domain measurements were acquired with a VNA (vector network analyzer - HP8722C). The instrument was calibrated up to the end of the feed cables. The cables were then connected to the test fixture and the response measured from one side to the other. Time domain measurements are obtained via Fourier transform from VNA tests. These measurements reveal the type of discontinuities at the interfaces plus contacts and establish bounds for digital signal risetime. 3

Test procedures To determine insertion loss a measurement of an arrangement of PCB to PCB only is performed. This measurement then serves for normalization of measurements taken with a flex and its connectors inserted. As a comparison, a reference trace on the PCB only is also evaluated. Setup A signal is fed to PCB connectors on a PCB with 50 Ohm microstrip lines. The PCB is connected via Pariposer material to a flex circuit, which in turn again via Pariposer connects to another PCB with connectors. Fig. 1 shows an example of this PCB, the connector and part of the flex circuit: Fig. 1 Flex connector test arrangement 4

Port assignments are as shown in Fig. 2: Fig. 2 Microstrip line flex connector and port assignments Connections to the VNA are made with high quality coaxial cables with K connectors. The differential properties are extracted from a sequence of several measurements during which two of the four ports are connected to 50 Ohm terminations while response on the other two ports is being recorded. 5

Measurements Time domain TDR reflection measurements are shown in Fig. 3 for a total of 4 differential pairs: Diff TDR rho 0.25 0.20 0.15 0.10 0.05 0.00-0.05-0.10 0 1 2 3 4 t [ns] GW N 107 Fig. 3 TDR signal from the flex connector The reflected signals from the complete assembly include the responses from the connectors and the PCBs. The first peak near 0 ns is due to the SMA to PCB connector. The corresponding impedances are shown in Fig. 4: 6

Diff TDR 120 115 110 105 Ohms 100 95 90 85 80 0 1 2 3 4 t [ns] GW N 107 Fig. 4 TDR signal from the assembly The impedance levels are slightly above 100 Ohms. The first flex connector is located at 1.4 ns (red arrow). This connector produces no distortion in the passing signal since it leaves no distinguishable signature in the TDR response. The other end of the assembly is not visible in the graph and is just beyond the recorded range. This is unavoidable because of the limited 5 ns span of the VNA. While it is possible to shift the response to show this interconnect, it too did not leave any noticeable imprint. 7

The TDT performance for a step propagating through the pin arrangement was also recorded (see Fig. 5). TDT THRU 1.2 1.0 0.8 rho 0.6 0.4 0.2 0.0-0.2-1 0 1 2 3 4 t [ns] Fig. 5 TDT measurement G W N 502 The TDT measurements for transmission show total contribution to risetime from all components for three different lengths of flex circuit (1.5, 5, 10 ). The 10-90% risetime values for the flex circuit connection are 125, 200 and 250 ps (10%-90%) and 75, 80 and 125 ps (20%-80%) for the 1.5, 5 and 10 connections, respectively. The trace on the far left is the system response which has a risetime of 25 ps. The excellent signal integrity of the Paricon connector is demonstrated by the following TDR trace: 8

Diff TDR 0.15 0.1 rho 0.05 0-0.05 0 0.2 0.4 0.6 0.8 1-0.1 t [ns] Fig. 6 Differential TDR of a short connection This differential TDR response shows the launch into a 1.5 long flex circuit on the left side. The probe at the end of the coax cable is slightly inductive, hence an upward peak occurs at the left edge of the graph. From there on the trace shows the reflections as the signal travels through the flex circuit until it reaches the Pariposer connection to the PCB (red arrow). This connection shows no contribution to the TDR response, underlining the performance of the Pariposer material.. 9

Frequency domain An insertion loss measurement is shown in Fig. 6 for the frequency range of 50 MHz to 20 GHz for the complete PCB to connector/flex/connector to PCB arrangements. Sdd21(f) db 0-5 -10-15 -20-25 -30 0 10 20 f [GHz] GW N 502 Fig. 7 Insertion loss S21 (f) The graph shows the total loss of the arrangement for flex lengths of 1.5, 5 and 10. Naturally, loss increases with increasing flex length. To extract the flex performance, a measurement of a PCB control trace of appropriate length was subtracted out. The resulting S21 for the three different flex types is shown below: 10

Sdd21(f) 0-5 db -10-15 -20 0 10 20 f [GHz] GW N 502 Fig. 8 Normalized insertion loss S21 (f) Insertion loss is less than 3 db to 21.3 GHz, 7.5 GHz and 2.8 GHz for the three different lengths, shortest to longest, respectively. An estimate of flex cable loss per 1 length was made by curve fitting the result for the longest flex connector and then reducing that result to the desired 1 length. The corresponding graph is shown below: 11

Sdd21(f) per inch db 0.0-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6 0 10 20 f [GHz] G W N 502 Fig. 9 Flex insertion loss per inch of cable As a reference the common mode insertion loss and the return loss for the longest flex connector are graphed below: 12

Scc21(f) db 0-10 -20-30 -40-50 -60-70 0 10 20 f [GHz] G W N 502 Fig. 10 Common mode insertion loss Sdd11 Sdd11 [db] 0-5 -10-15 -20-25 -30-35 -40-45 0 5 10 15 20 f [GHz] GW N 706 Fig. 9 Return loss as a function of frequency 13