ZIP SYSTEM SHEATHING-ROOF WITH METAL COVERING AT EAVE A-1
ZIP SYSTEM ROOF W/ METAL AT EAVE FOR BRICK WALL ASSEMBLY A-2 ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING ROOF TRUSS 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES ICE DAM PROTECTION AS PRESCRIBED BY LOCAL BUILDING CODE. SOFFIT VENT
TYPICAL FELT ROOF W/ METAL INTO ZIP SYSTEM SHEATHING-WALL ABOVE A-4 WALL ASSEMBLY VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEM SHEATHING WOOD OR LIGHT GAUGE METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING ROOF ASSEMBLY METAL ROOF COVERING ROOF UNDERLAYMENT PLYWOOD OR OSB SHEATHING ROOF TRUSS OR RAFTERS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING LAPPED OVER STANDING SEAM METAL ROOF ROOF UNDERLAYMENT
ZIP SYSTEM SHEATHING-ROOF W/ METAL INTO WATER RESISTANT BARRIER WALL ABOVE A-5 WALL ASSEMBLY VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) BUILDING PAPER/HOUSEWRAP PLYWOOD OR OSB SHEATHING WOOD OR LIGHT GAUGE METAL STUDS BUILDING PAPER/HOUSEWRAP ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING ROOF TRUSS OR RAFTER BUILDING PAPER/HOUSEWRAP LAPPED OVER FLASHING ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING LAPPED OVER STANDING SEAM METAL ROOF
ZIP SYSTEM SHEATHING ROOF WITH METAL AT RIDGE VENT A-6 METAL RIDGE CAP VENT ROOF ASSEMBLY ASPHALT-FIBERGLASS SHINGLES ZIP SYSTEM SHEATHING ROOF TRUSS OR RAFTERS CUT BACK ZIP SYSTEM TAPE PRIOR TO INSTALLATION OF RIDGE VENT (OPENING SIZE BASED ON RIDGE VENT MANUFACTURER'S RECOMMENDATIONS) ZIP SYSTEM TAPE INSTALLED AT RIDGE FOR TEMPORARY DRY-IN
ZIP SYSTEM SHEATHING-ROOF WITH METAL AT SKYLIGHT A-7 ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING FOLLOW SKYLIGHT MANUFACTURER'S RECOMMENDED FLASHING/WATERPROOFING DETAILS ROOF SLOPE
ZIP SYSTEM SHEATHING W/ METAL COVERING AT WALL TO ROOF TRANSITION A-8 WALL ASSEMBLY ZIP SYSTEM SHEATHING WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES CODE APPROVED FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148) INSTALLED AT JOINT BETWEEN ZIP SYSTEM WALL AND ROOF SHEATHING* ZIP SYSTEM SHEATHING (ROOF).. 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES
ZIP SYSTEM SHEATHING-ROOF W/ METAL W/ CRIMPED VALLEY FLASHING A-9 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. METAL VALLEY FLASHING ZIP SYSTEM TAPE*
ZIP SYSTEM SHEATHING-ROOF WITH METAL WITH FLAT VALLEY FLASHING A-10 ZIP SYST TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148) LAPPED OVER METAL VALLEY FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. METAL VALLEY FLASHING ZIP SYSTE TAPE*
ZIP SYSTEM SHEATHING-ROOF WITH METAL AT PLUMBING VENT A-11 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. UPPER METAL ROOF PANEL CUT TO FIT AROUND PREFORMED METAL ROOF VENT LAP LOWER PANEL OF METAL ROOF UNDER PREFORMED METAL ROOF VENT
ZIP SYSTEM SHEATHING-ROOF WITH METAL INTO ZIP-WALL AT CHIMNEY A-12 ZIP SYSTE SHEATHING ON WOOD-FRAMED CHIMNEY FLUE INSTALL ZIP SYSTEM TAPE ON ALL JOINTS OF CHIMNEY CRICKET LAP ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) OVER TOP OF CONTINUOUS FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING CODE-APPROVED FLASHING AT ROOF TO CHIMNEY INTERSECTION FLASHING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES
ZIP SYSTEM ROOF W/ METAL INTO ZIP-WALL AT CHIMNEY (ROOF EDGE) A-13 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING ZIP SYSTEM SHEATHING ON WOOD-FRAMED CHIMNEY FLUE FLASHING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS