METAL COVERING AT EAVE A-1



Similar documents
Detached accessory structures that contain no conditioned floor area are exempt.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Asphalt Shingle Application Requirements

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

NRCA s steep-slope manual is thoroughly revised for 2013

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Residential Roofing Guide

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Chapter 6 ROOF-CEILING SYSTEMS

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Directions For Applying Malarkey Laminate Shingles

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

SHINGLE APPLICATION GUIDE

Best Barns USA Assembly Book

Shingle Installation Guide

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Retrofitting an Insulated Cold Roof

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

CHAPTER 7: Building Systems ROOFING SYSTEMS

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

INSTALLATION OF A BAY WINDOW

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Chapter 9: INSTALLING ROOFING

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Installation Manual for STANDING SEAM ROOFING

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Mark Cramer Inspection Services, Inc.

Titan Old World Spanish Tile

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

providing documentation that validates the year of construction. Acceptable documents include

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles

HCD DSA OSHPD 1 2 1/AC AC SS

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals Magnolia Ave. Chino, CA 91710

Metal Roof Systems in High-Wind Regions

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Residential Building Inspection Policies

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

How To Repair A Boat Landing Deck With A Boat Bed

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Section Page Section Page

March 14, Installation of Bay, Bow and Garden Windows

South Carolina Department of Insurance

RESIDENTIAL METAL BUILDING COMPONENTS

2.1. Architectural Character. Mountain. Agrarian. Craftsman. Gold Rush

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

SECTION STANDING SEAM METAL ROOFING

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

SECTION COMPOSITE ROOF TILE SYSTEMS

Additions and Alterations

FS Deck Mounted Skylight Installation Instructions 15-90

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

Window Sill Details for Effective Drainage of Water

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

Metal Roofing Practical Design

The Wo rd. Shingle Warranties - Getting Real

Gerard Installation Manual Shingle Profiles

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

METAL ROOFING INSTALLATION GUIDE

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Glossary of Roofing Terms for the Consumer

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

CertainTeed. Protecting Your Home From Ice Dams Homeowner s Guide

INDIAN HEAD ELEMENTARY SCHOOL

High Wind & Hail Standards

ROOF ASSEMBLIES CHAPTER 9

ISO Types 1-6: Construction Code Descriptions

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.

Delaney-Vogel School

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

DETAIL MANUAL. for Standing Seam East 23rd Street Chattanooga, TN South Lee Hwy. Cleveland, TN 37311

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

How to repair your existing low slope flat roof.

PDmB, Inc. Definitions

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam

Home Inspection Report

Most of my work is in exterior remediation, both as a builder. Adhered Concrete Masonry Veneer To avoid water damage, treat faux stone like stucco

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines

TIMBER FRAME STANDARD DETAILS SEPTEMBER 09

SUPER SHED. Indoor shelter for your outdoor tools.

GreenGuard Housewrap Installation Guide

METAL ROOFING SYSTEM ORDERING & INSTALLATION SELF HELP GUIDE. Fabral, Inc 1

Transcription:

ZIP SYSTEM SHEATHING-ROOF WITH METAL COVERING AT EAVE A-1

ZIP SYSTEM ROOF W/ METAL AT EAVE FOR BRICK WALL ASSEMBLY A-2 ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING ROOF TRUSS 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES ICE DAM PROTECTION AS PRESCRIBED BY LOCAL BUILDING CODE. SOFFIT VENT

TYPICAL FELT ROOF W/ METAL INTO ZIP SYSTEM SHEATHING-WALL ABOVE A-4 WALL ASSEMBLY VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEM SHEATHING WOOD OR LIGHT GAUGE METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING ROOF ASSEMBLY METAL ROOF COVERING ROOF UNDERLAYMENT PLYWOOD OR OSB SHEATHING ROOF TRUSS OR RAFTERS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING LAPPED OVER STANDING SEAM METAL ROOF ROOF UNDERLAYMENT

ZIP SYSTEM SHEATHING-ROOF W/ METAL INTO WATER RESISTANT BARRIER WALL ABOVE A-5 WALL ASSEMBLY VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) BUILDING PAPER/HOUSEWRAP PLYWOOD OR OSB SHEATHING WOOD OR LIGHT GAUGE METAL STUDS BUILDING PAPER/HOUSEWRAP ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING ROOF TRUSS OR RAFTER BUILDING PAPER/HOUSEWRAP LAPPED OVER FLASHING ADHESIVE BACKED FLASHING RECOMMENDED (MUST MEET AC148) CODE APPROVED FLASHING LAPPED OVER STANDING SEAM METAL ROOF

ZIP SYSTEM SHEATHING ROOF WITH METAL AT RIDGE VENT A-6 METAL RIDGE CAP VENT ROOF ASSEMBLY ASPHALT-FIBERGLASS SHINGLES ZIP SYSTEM SHEATHING ROOF TRUSS OR RAFTERS CUT BACK ZIP SYSTEM TAPE PRIOR TO INSTALLATION OF RIDGE VENT (OPENING SIZE BASED ON RIDGE VENT MANUFACTURER'S RECOMMENDATIONS) ZIP SYSTEM TAPE INSTALLED AT RIDGE FOR TEMPORARY DRY-IN

ZIP SYSTEM SHEATHING-ROOF WITH METAL AT SKYLIGHT A-7 ROOF ASSEMBLY METAL ROOF COVERING ZIP SYSTEM SHEATHING FOLLOW SKYLIGHT MANUFACTURER'S RECOMMENDED FLASHING/WATERPROOFING DETAILS ROOF SLOPE

ZIP SYSTEM SHEATHING W/ METAL COVERING AT WALL TO ROOF TRANSITION A-8 WALL ASSEMBLY ZIP SYSTEM SHEATHING WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES CODE APPROVED FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148) INSTALLED AT JOINT BETWEEN ZIP SYSTEM WALL AND ROOF SHEATHING* ZIP SYSTEM SHEATHING (ROOF).. 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES

ZIP SYSTEM SHEATHING-ROOF W/ METAL W/ CRIMPED VALLEY FLASHING A-9 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. METAL VALLEY FLASHING ZIP SYSTEM TAPE*

ZIP SYSTEM SHEATHING-ROOF WITH METAL WITH FLAT VALLEY FLASHING A-10 ZIP SYST TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148) LAPPED OVER METAL VALLEY FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. METAL VALLEY FLASHING ZIP SYSTE TAPE*

ZIP SYSTEM SHEATHING-ROOF WITH METAL AT PLUMBING VENT A-11 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING. UPPER METAL ROOF PANEL CUT TO FIT AROUND PREFORMED METAL ROOF VENT LAP LOWER PANEL OF METAL ROOF UNDER PREFORMED METAL ROOF VENT

ZIP SYSTEM SHEATHING-ROOF WITH METAL INTO ZIP-WALL AT CHIMNEY A-12 ZIP SYSTE SHEATHING ON WOOD-FRAMED CHIMNEY FLUE INSTALL ZIP SYSTEM TAPE ON ALL JOINTS OF CHIMNEY CRICKET LAP ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) OVER TOP OF CONTINUOUS FLASHING METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING CODE-APPROVED FLASHING AT ROOF TO CHIMNEY INTERSECTION FLASHING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1/8-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES

ZIP SYSTEM ROOF W/ METAL INTO ZIP-WALL AT CHIMNEY (ROOF EDGE) A-13 METAL ROOF COVERING - FASTEN PER CODE USING FASTENERS COMPATIBLE WITH SPECIFIC METAL ROOF COVERING ZIP SYSTEM SHEATHING ON WOOD-FRAMED CHIMNEY FLUE FLASHING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS