Temperature controller for heated/chilled ceiling systems



Similar documents
CRK24-B1 Heated/chilled ceiling system

CR24-.. Single room controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Belimo Gateway MP to Modbus RTU - UK24MOD

HERZ-Thermal Actuators

Product and Application Description

RRV934. Multi-controller. Synco living

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Heating Controller. Building Technologies HVAC Products

VAV system solution for non-pressure-dependent applications in enclosed spaces

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Product and functional description

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Electric Rotary Actuator - On/Off or programmable control actuator

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Air damper actuators

Flush-mounted room thermostats

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Electronic Control Devices The European Product Catalogue 2007

Digital input modules

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electronic Control Devices The European Product Catalogue 2007

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

How To Use A Power Supply On A Powerline 2.2 (Ai)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

HCR3.2/.. Chipcard reader HOTEL SOLUTION

basicdim DGC Compact control module

Inwall Room Temperature Unit

ACS-30-EU-EMDR-10-MOD

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

DALI RC BASIC SO. Control unit Operating instructions

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

HCE80/HCC80/HCE80R/HCC80R

Inwall 4 Input / 4 Output Module

Modular I/O System Analog and Digital Interface Modules

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MINI MCR-SL-R-UI(-SP)

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Combi switchbox with integrated 3/2 way pilot valve

Controls for fan coil units and cassettes

Actuator for modulating control AME 435

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

T5000 T000 LCD Digital Fan Coil Thermostat

Installation Instructions. Thermo Call TC3

CO2 Alarm. Operation. Application

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

KNX Gateway RGK E-01

Operating instructions IV / 2007

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Electrical connection

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

WD-AMX Water Detection Controllers

SYSTEM 45. C R H Electronics Design

Operating instructions II / 2004

T7560A,B,C Digital Wall Module

Proportional pressure regulators VPPE

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Duct Humidity Transmitter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Smile. The All-In-One Heating Controller

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Installation Instructions. ThermoCall TC4. Entry/Advanced

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Electronic Power Control

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Multi-Range Programmable DC Power Supplies 9115 Series

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Fire Alarm Control Panel. Family. Operating Manual

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

ALARMLINE ANALOGUE Linear Heat Detection System

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

MasterINTERFACE 39 Series - Relay interface modules

SYSTEM 4C. C R H Electronics Design

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

User Manual THR840DUK Digital Thermostat

Thermostat with display

T7079A,B Solid State Remote Temperature Controllers

is then retained absolutely without interruption.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Transcription:

Product information Temperature controller for heated/chilled ceiling systems Table of contents Overview of the system 2 Brief description, Accessories 3 Technical data sheet Technical data 5 Safety notes 5 Product features 6 Configuration 6 Electrical installation 6 Operation 7 Functions Introduction 9 Function overview 9 Setpoint determination 10 Pre-comfort 11 Energy hold off (EHO) 11 Chilled ceiling with dew point monitoring 12 External setpoint shift 12 External temperature sensor (ai1) 13 Analogue outputs 13 Dimensions, installation, commissioning, service Dimensions [mm] 15 Mechanical installation 15 Electrical installation 15 Design for supply / wire sizing 16 Commissioning / Power On response 16 Test and simulation mode 16 Internal Function test 17 Simulation control sequence 17 www.belimo.eu S4- en v1.1 10.2009 subject to changes 1 / 20

Overview of the system Single room controller Heated/chilled ceiling applications 6-way ball valve and rotary actuators EXT-K3B2-..-.. + LR24A-MP / LR24A-SR Accessories Diagnostic and setting device ZTH-GEN Setting for MP / MFT(2) actuators PC-Tool ZK1-VAV Connection cable ZTH-VAV to CRK24, Diagnostic socket 1/2 2 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Brief description, Accessories Brief description The room temperature controller is precisely designed for the regulation of heated / chilled ceilings. The output sequence of the controller is calibrated to the new 6-way ball valve EXT-K3B2-..-.. with LR24A-MP / LR24A-SR actuator. This controller should therefore only be utilised in the actuator in combination with the 6-way ball valve. The multitude of override features makes possible an economically and energetically optimised system solution for individualised control of the room climate. Device Standard model with user interface (setpoint adjustment, mode switch and status display). For operation, see page 7. Accessories Mechanical accessories Type Description CRZA-A CRZW Spare cover without user interface Spare baseplate www.belimo.eu S4- en v1.1 10.2009 subject to changes 3 / 20

4 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Technical data sheet Temperature controller for single-room applications with one analogue output: The 6-way ball valve for the regulation of a heated/chilled ceiling can be connected with the analogue output ao1. Technical data Safety notes Electrical data Nominal Voltage AC 24 V 50/60 Hz Dimensioning 3 VA, without actuators Power supply range AC 19.2 28.8 V Connections Terminal block 1 3: 2.5 mm 2 Terminal block 4 8: 1.5 mm 2 Functional data Control characteristics P P-band heating / cooling Selectable: 2.0 K / 1.0 K or 4.0 K / 2.0 K External temperature sensor (ai1) Type NTC, 5 k, Power supply range 10 45 C e.g. Belimo Type TFK Setpoint Adjustment range 15 36 C (Default 21 C) Energy hold off (EHO) Pre-comfort Heating 15 C / Cooling 40 C Heating 3 K / Cooling +3 K Dead band 1 K Frost protection limit 10 C Operation Mode switch and status display (LED) AUTO (green) ECO (orange) MAX (red) Rotary knob for setpoint adjustment ±3 K Communication connection for field devices 2 x PP (for PC-Tool, ZTH-GEN, etc.) Inputs Output 2 x analogue, 2 x digital External temperature sensor (ai1) Type NTC, 5 k, Power supply range 10 45 C External setpoint shift (ai2) 0 10 V correspond to: 0 10 K Digital inputs (di1, di2,) Contact rating 10 ma 1x analogue 6-way ball valve (ao1) (0) 2 10 V, max. 5 ma Norms and Standards Protection class III Safety extra-low voltage Degree of protection IP30 (EN 60529) Mode of operation Type 1 (EN60730-1) Software class A (EN 60730-1) EMC CE according to 2004/108/EU Ambient conditions Operation 0 +50 C / 20 90% r.h. (non-condensating) Transport and storage 25 +70 C / 20 90% r.h. (non-condensating) Dimensions / Weight Dimensions (H x W x D) 99 x 84 x 32 mm Weight 105 g Housing colour Baseplate NCS2005-R80B light grey (corresponds approximately to RAL 7035) Cover RAL9003 signal white! The controller is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by government agency authorities must be observed during assembly. The device does not contain any parts that can be replaced or repaired by the user. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. www.belimo.eu S4- en v1.1 10.2009 subject to changes 5 / 20

Technical data sheet Product features Energy hold off (EHO) Pre-comfort Frost Dew point limitation In energy saving mode, the room temperature is regulated to the building protection level, i.e. the heating setpoint is significantly reduced or the cooling setpoint is significantly increased, for instance in a room with an open window. The room temperature is reduced to stand-by level, i.e. the heating setpoint is slightly reduced and/or the cooling setpoint is slightly increased, for instance in a room that is temporarily unoccupied. If the current room temperature falls below 10 C, then the frost function will be activated. If the optional connectable dew point limiter responds, then the valve is moved into neutral position. External temperature sensor External setpoint shift An external temperature sensor can be connected at analogue input ai1. An external DC 0... 10 V signal at the analogue input ai2 can be used to shift the basic setpoint by 0... 10 K, e.g. for summer/winter compensation. The functions are described in detail on pages 9 to 13. Configuration Configuration ao1 modulating ao1 On/Off ao1 [V] ao1 [V] ON 10 10 OFF ao1 l 1 2 3 4 5 6 (heating) 7.3 ao1 (heating) l DIP Default settings 1 P-Band normal P-Band wide 2 Output ao1 modulating Output ao1 On/Off 4.7 2 ao1 (cooling) 0 10 33 66 90 100 [%] 6 2 ao1 (cooling) 0 10 33 66 90 100 [%]. Electrical installation Wiring diagram Notes Connect via safety isolation transformer.! Parallel connection of other actuators possible. Note the performance data. AC 24 V ~ External NTC temperature sensor 0 10 V Shifting Pre-comfort EHO Dew point limiter 3 4 5 ao1 U5 1 U5 2 ai1/di1 di2 ai2 1 2 6 7 8 1 2 3 5 y U ~ Actuator for 6-way valve Inputs Outputs 3 ai1 External temperature sensor 6 ao1 System output for 6-way valve di1 Pre-comfort Other connections 4 di2 Energy hold off / dew point 7 PP1 Diagnostic socket 1 5 ai2 External setpoint shift 6 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Operation Operating level 1 Operation Operating mode / Setpoint Rotary knob for setpoint adjustment Potentiometer ±3 K Status display MAX (red) ECO (orange) AUTO (green) Mode switch MAX ECO AUTO Mode switch and status display Selection can be made between three operating modes: AUTO optimum comfort mode The room will be kept at comfort zone status insofar as the external control signals permit this. All control functions are enabled. ECO optimum energy mode The room will be kept at pre-comfort status insofar as the external control signals permit this. Reduced heating ( 3 K) and elevated cooling setpoints (+3 K) are in effect in this status. Starting from this status, the room can be returned to comfort status within a short time. Sequence control is enabled. The operating mode ECO is intended for rooms not continuously occupied and/or for reduced requirements. MAX Boost function The room will be heated or cooled at maximum power, insofar as the external control signals permit this. The Boost function is switched off: Timer off Setpoint is reached Selection of a different mode (AUTO or ECO) Operating level 2 Configuration DIP switch for configuration Order-Nr. CR24-B2xxxxx ON OFF 1 2 21 15 W H 36 Basic setpoint setting Application / Parameters DIP switch for configuration DIP switches 1 and 2 Basic setpoint setting W H (heating setpoint) Potentiometer 15 36 C (Default 21 C) Label for settings Recording the settings used (DIP switch and basic setpoint) U5/ 2 U5/ 1 Label for settings Operating level 3 Service Test / Simulation Measuring point terminals Measuring points for all connection terminals (also during operation). Measuring point terminals 2 1 1 2 3 4 5 6 7 8 Internal function test A comprehensive internal function test can be started with the mode switch which makes it possible to check the controller, including nominal voltage (AC 24V). The three LEDs (status display) are used thereby to display the voltage level and the statuses. Simulation control sequence The rotary knob for the setpoint adjustment can be used to simulate the connected actuators, and thus the heating and cooling control sequences, independent of the room temperature. Rotary knob for simulation of control sequence Internal function test ZTH-GEN / PC-Tool connection ZTH-GEN / PC-Tool connection The diagnostic socket 1 is used for PP communications with the connected Belimo MFT actuator. Physical access to the valve actuator can be dispensed with as a result. www.belimo.eu S4- en v1.1 10.2009 subject to changes 7 / 20

8 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Functions Introduction The control functions of the define the behaviour of the controller output or influence the current setpoint, respectively. Operation can be automated and comfort and energy savings potential enhanced through the utilisation of corresponding sensor mechanisms at the input side. The corresponding functions are described in detail in the following. Function overview Supply Application Operation Inputs Output Functions Installation AC 24 V / 50/60 Hz Room temperature controller in the comfort zone Internal temperature sensor (Type NTC, Power supply range 10 45 C) Setpoint (adjustment range 15... 36 C) Mode selection switch: AUTO ECO MAX Mode display LED: AUTO ECO MAX Setpoint adjustment rotary knob ±3 K Pre-comfort Dew point limitation Energy hold off (EHO) External temperature sensor (Type NTC 5 kω, Power supply range 10 45 C) External setpoint shift 0 10 V 2 10 V System output: Belimo 6-way ball valve Control characteristics: P P-Band, switchable Output can be switched (modulating / On/Off) Room temperature monitoring (frost) Internal Function test with nominal voltage check Commissioning mode with simulation of output and sequence Diagnostics via integrated PC-Tool connection Surface mounting with flush-mounted or surface-mounted connection Application documentation Continually expanded, comprehensive documentation with specific applications is available for the controller. www.belimo.eu S4- en v1.1 10.2009 subject to changes 9 / 20

Functions Setpoint calculation Valve opening [%] 100 Pre-comfort EHO 0 Frost Dew point W A current setpoint t Room [ C] Dead band W H Basic setpoint W s Setpoint shift 0 10 V Setpoint adjustment ±3 K Operating status Heating setpoint Cooling setpoint Comfort Pre-comfort Basic setpoint W H ±3 K setpoint adjustment + Setpoint shift 0 10 V Comfort-Heating setpoint W A 3 K Pre-comfort-Offset heating Comfort-Heating setpoint W A +1 K dead band Comfort-Heating setpoint W A +1 K dead band +3 K Pre-comfort-Offset cooling Energy hold off fix 15 C (building protection) fix 40 C (building protection) Frost fix 10 C without function Examples Comfort Pre-comfort Y Y 3 K Pre-comfort-Offset Heating +3 K Pre-comfort-Offset Cooling t R +1 K dead band t R +1 K dead band 23 C Comfort setpoint W A 23 C Comfort setpoint W A 10 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Functions Pre-comfort Digital input di1 AC 24 V ~ NTC If a local detector (e.g. a motion detector) has an effect on the digital input di1 and closes the corresponding contact, then the room will be regulated to stand-by level, i.e. the heating setpoint is reduced by 3 K or the cooling setpoint is raised by 3K, respectively. Typical applications [%] 100 1 2 Y Pre-comfort 3 ai/di1 Pre-comfort One motion detector, light switch or other detector at di1 reduces the energy consumption in unoccupied rooms. Superordinate imperative command, e.g. GLT. Notes The frost limit is monitored with the internal sensor during Pre-comfort when an external temperature sensor is used. As a result of the automatic sensor recognition feature, the switch-over to Pre-comfort takes approximately 40 seconds. Legend 0 W A t Room [ C] Y W A Output signal Current setpoint Energy Hold Off (EHO) Digital input di2 AC 24 V ~ 1 2 Energy Hold Off 4 di2 If a local detector (e.g. a window switch) has an effect on the digital input di2 and closes the corresponding contact, then the room will be regulated in energy-savings mode to the building protection level, i.e. the heating setpoint is significantly reduced (15 C) and/or the cooling setpoint is significantly raised (40 C), so that sensitive furnishings (plants, pictures, etc.) will not be able to suffer any damage. Typical applications One window switch at di2 stops energy consumption as soon as the window is opened until the lower or upper building protection limit has been reached. Superordinate imperative command, e.g. GLT. [%] 100 Y EHO Notes The 6-way valve is moved into neutral position during the Energy Hold Off (ao1 = 6 V). The mode switch (operating level 1) is deactivated during the Energy Hold Off (the input di2 has higher priority). 0 t Room [ C] W A Legend Y Output signal W A Current setpoint www.belimo.eu S4- en v1.1 10.2009 subject to changes 11 / 20

Functions Chilled ceiling with dew point limiter AC 24 V ~ Dew point Cooling / Heating Dew point reached Digital input di2 If the optional connectable dew point limiter responds, then the output ao1 is overridden to 6 V by means of the input di2 (external dew point limiter). The 6-way ball valve moves into neutral position. Typical applications Chilled ceiling systems in which one dew point limit is required. 1 2 6 7 ao1 U5 1 di2 4 1 2 3 5 Y U5 ~ Belimo actuator for 6-way valve ao1 [V] 10 ao1 (heating) l 7.3 Dew point 4.7 2 ao1 (cooling) 0 10 33 66 90 100 [%]. External setpoint shift Analogue input ai2 AC 24 V ~ Setpoint shift 0 10 V An external DC 0...10 V signal at the analogue input ai2 can be used to raise the basic setpoint by 0... 10 K (corresponding to 0 10 V). Typical application Summer/Winter Compensation 5 ai2 1 2 W [ C] 26 21 16 0 5.0 10 S [V] Legend W Setpoint S Shift signal Notes A negative shift is possible by setting the basic setpoint to the desired final setpoint, e.g. from 21 C (default value) to 16 C. This results in the following correspondences: 0 5 V: 16 21 C and 5 10 V: 21 26 C (see illustration at the left). 12 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Functions External temperature sensor (ai1) An external NTC temperature sensor can be connected at analogue input ai1. Sensor type: NTC 5k (5 kω), e.g. Belimo TFK. Typical applications More flexible placement of the sensor for recording the room temperature Temperature measurement in the ventilation channel for recording the average room temperature. Notes The controller recognises it automatically if an external sensor is connected. No additional adjustments are required. The simultaneous utilisation of Pre-comfort at di1 is possible, although in this case a switchover to the internal sensor is made (see also «Pre-comfort»). As a result, the current room temperature is monitored for building protection. AC 24 V T ~ External NTC temperature sensor Pre-comfort 3 ai/di1 1 2 Analogue outputs LR24A-MP Actuator for 6-way ball valve System output «ao1» (Terminal 6). diagnostic socket «U5/1» (Terminal 7). AC 24 V ~ Note When using an LR24A-MP, it is expedient to direct the communications signal U5 of the actuator to the controller. Interventions can be implemented on the actuator by means of controller diagnostic socket 1 without the need for direct physical access. ao1 U5 1 U5 3 4 5 2 ai1/di1 di2 ai2 1 2 6 7 8 1 2 3 5 y U ~ LR24A-MP Actuator for 6-way valve www.belimo.eu S4- en v1.1 10.2009 subject to changes 13 / 20

14 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Dimensions, installation, commissioning, service Dimensions [mm] 56 84 32 60 56 99 90 Mechanical installation 1. Remove the housing cover. 2. Pull out slightly the wall of the housing to release the pcb. 3. Remove the PCB. Rotary knob for setpoint adjustment If the rotary knob has been removed proceed as follows: a. Insert the rotary knob approximately half way and turn it clockwise as far as the stop. b. Remove the knob and align it so that the cam is flush with the left stop (see left). c. Insert the knob fully. 2 1 2 3 4 5 6 7 8 3 1 Left stop Cam Electrical installation 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Flush-mounted connection Surface-mounted connection 2.5mm 2 AC 24V - - 1.5mm 2 1 2 3 4 5 6 7 8 Terminal connection 1 8 www.belimo.eu S4- en v1.1 10.2009 subject to changes 15 / 20

Dimensions, installation, commissioning, service Power supply design / wire sizing In addition to the actual wire sizing, attention must also be paid to the surrounding area and the cable routing. Signal cables must not be laid in the vicinity of load cables, objects liable to cause EMC interference. etc. Paired or layer stranded cables improve immunity to interference. 24 V supply Wire sizing and cabling Analogue input connection ai1 The wire sizing and installation of the AC 24 V supply, the fuse protection, and the cables are dependent on the total operated load and local regulations. Account must be taken of the following performance data, including starting currents: Wire sizing values for room temperature controllers: 3 VA per Wire sizing values for the valve actuators can be obtained from current data sheets and product information (www.belimo.eu) Other devices to be operated with the AC 24 V supply Reserve capacity for subsequent expansion (if planned) The analogue input ai1 is used to connect an external NTC 5 kω temperature sensor. The sensor value is 5969 Ω at 21 C. A change of 50 Ω corresponds to approximately 0.2 K in this range. The sensor cable constitutes a series resistance that must be added to the actual sensor value. Assuming a cable length of 15 m (2 x 15 = 30 m), the resistance of one 0.75 mm 2 Cu cable is approximately 0.7 Ω, in other words negligible. To prevent interference, however, the sensor cable should be a maximum of 20 m long. Commissioning / Power on behaviour Commissioning 1. Assemble the baseplate of the housing and connect the cables (see page 15) 2. Configure the DIP switches on the printed circuit board according to the required application. 3. Assemble the printed circuit board on the baseplate of the housing and then mount the housing cover (see page 15) 4. Switch on the nominal voltage AC 24 V 5. Optional: start the test and simulation mode (see below) When the voltage is applied, the system starts operating normally in AUTO mode unless the test simulation mode is selected. The active operating status is determined primarily by the configuration of the DIP switches and the status of the inputs. Power on behaviour After power on of the voltage supply the output gets initialised as follows: ao1 = 0 V Subsequently the controller switches automatically to the control mode. Test and simulation mode All controllers are supplied with two auxiliary programs for commissioning and servicing: Internal function test Control sequence simulation Activating test and simulation mode Deactivating test and simulation mode The test and simulation mode of controllers can be activated easily with the mode switch on the operator panel. To activate test mode 1. Set the mode switch to MAX The red LED (MAX status indication) lights up 2. Keep the mode switch pressed for ten seconds The internal function test is activated (see below) To activate simulation mode 3. Press the mode switch again briefly for approx. one second The green LED (COMF status indication) flashes Control sequence simulation is activated (see below) The test and simulation mode can be deactivated either by pressing the mode switch again for ten seconds or by interrupting the power supply. It is also deactivated automatically 15 minutes after the last user action (auto-reset). 16 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

Dimensions, installation, commissioning, service Internal function test The internal function test tests the nominal voltage that is connected to the controller (AC 24 V), in other words the complete electrical wiring system from the control cabinet to the controller.. The three LEDs (status indication) indicate the voltage level (see below) and states during the test. Note Case B and C do not need further attention. In case A (<20 V) attention must be paid to the following points: Quality of the wiring and connections Cable length and diameter and the transformer sizing Nominal voltage (AC 24 V) LED (status indication) Scenario A Scenario B Scenario C MAX red flash flash permanently on ECO orange flash flash permanently on AUTO green permanently off flash permanently on <20 V 20 22 V >22 V Control sequence simulation In the simulation mode, the connected actuator can be operated regardless of the room temperature. This permits the function of the system to be checked. Cooling 2 1 0 W = X +1 Heating +2 3 +3 Notes The external control signals (di1 and di2) are suppressed during the simulation. The potentiometer may be adjusted only slowly, due to the system-dependent attenuation of the setpoint potentiometer in simulation mode. Simulation mode is automatically deactivated 15 minutes after the last user action (auto-reset). Output [V] 10 6 2 0 XpK XpH out 1 3 0 +3 Potentiometer (setpoint adjustment) Shift www.belimo.eu S4- en v1.1 10.2009 subject to changes 17 / 20

18 / 20 S4- en v1.1 10.2009 subject to changes www.belimo.eu

All-inclusive. 5 year guarantee World-wide on your doorstep Complete product range froma single source Tested quality Short delivery time Comprehensive support Switzerland Germany Austria Slovakia BELIMO Automation AG Sales Switzerland Brunnenbachstrasse 1 CH-8340 Hinwil Tel. +41 (0)43 843 62 12 Fax +41 (0)43 843 62 66 verkch@belimo.ch www.belimo.ch Benelux BELIMO Servomotoren BV BENELUX Postbus 300, NL-8160 AH Epe Radeweg 25, NL-8171 MD Vaassen Tel. +31 (0)578 57 68 36 Fax +31 (0)578 57 69 15 info@belimo.nl www.belimo.nl BELIMO Stellantriebe Vertriebs GmbH Welfenstrasse 27 D-70599 Stuttgart Tel. +49 (0)711 1 67 83-0 Fax +49 (0)711 1 67 83-73 info@belimo.de www.belimo.de At no charge Orders: Tel. 0711 1 67 83-83 Technical Consultation: Tel. 0711 1 67 83-84 Fax 0711 1 67 83-73 Personal consultation with Regional Sales Director in: Berlin, Hanover, Düsseldorf Leipzig, Frankfurt, Munich Hamburg, Stuttgart BELIMO Automation Handelsgesellschaft m.b.h. Geiselbergstrasse 26-32 A-1110 Vienna, Austria Tel. +43 (0)1 749 03 61-0 Fax +43 (0)1 749 03 61-99 info@belimo.at www.belimo.at Austria West Tel. +43 (0)644 14 26 365 Fax +43 (0)732 70 10 51 dietmar.niederhametner@belimo.at Hungary Tel. +36 (06)20/920 46 16 Fax +36 (06)23/37 77 30 gabor.koeves@belimo.at Tel. +43 (0)1 749 03 61-0 Fax +43 (0)1 749 03 61-99 info@belimo.at Slovenia/Croatia/Bosnia Tel. +386-(0)41-75 89 63 Fax +386-(0)4-2342-761 samo.smid@belimo.at Serbia/Montenegro/ Macedonia/Bosnia Tel./Fax +381-(0)11 311-9127 branimir.petrovic@belimo.at Belimo worldwide: www.belimo.com