1.7 Accessories for Saia PCD programmable controllers



Similar documents
PCD Saia PCD2 programmable controllers. Overview of Saia PCD2 device series. Saia PCD2.M5 controllers Page 42

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

SMS GSM Alarm Messenger

PCS0100en Persy Control Services B.V. Netherlands

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Rack mounted telephone- and leased line modem for industrial applications

40.3. Control Relays and Timers

connecdim Gateway G1 Ethernet TCP/IP to DALI

Frequency selective monitoring and logging of environmental electromagnetic fields

Temperature & Humidity SMS Alert Controller

User manual Compact Web PLC WP240 series IEC-line

Application/Connection Examples

MINIMAT-EC-Servo Screwdriver Spindles

Telephone- and leased line modem for industrial applications TD-36

TX OPEN RS232/485 module

Climate Ready Control Systems Technical Specifications

M2M/IoT Solutions.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Digital input modules

Electronic Control Devices The European Product Catalogue 2007

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Waveguide Access Point WGA631. Product Guide

Master & Amplifier For ModuSat Communal Heating

NEW. EVEN MORE data acquisition and test stand automation

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

IntesisBox Modbus Server Fidelio IP

EDI Distributor Control Interface Wiring and Setup Instructions

Modular I/O System Analog and Digital Interface Modules

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

GSM ATT Modules Simply effective remote control

DCS Data and communication server

ewon Price List Rev: R45N

Operation and Installation Manual

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Square D Model 6 Motor Control Centers

ewon - Serial to Ethernet Gateways

TELECOM HF VHF UHF over IP

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

HARTING econ 3000 Introduction and features

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

TK800-Series Industrial GPRS / UMTS / LTE Router

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

IntesisBox KNX Modbus TCP master

GSMPBX version 1.3 Datasheet

Vibration analysis and monitoring Compact. Powerful. Modern technology.

HARTING mcon 3000 Introduction and features

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

HARTING mcon 1000 Introduction and features

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Optimize your simple machines... Modicon M218 Selection Guide

OZW30. Central Unit SYNERGYR

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

BridgeWay Fixed Base Radio Telecom VoIP Gateway

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Bristol ControlWave Redundant Control

Model: DC-A2IO Advanced HVAC Controller

SECTION LOW VOLTAGE LIGHTING CONTROLS

Static energy meters

TrueAlarm Fire Alarm Systems

Smart relays Zelio Logic Step into an intuitive world!

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

NC-12 Modbus Application

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

NUEVO With ::::::::::::::::

Unidirectional Transmitter/ Receiver Units Introduction

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

SNAP-SCM-PROFI Communication Module

PLC training panel (Twido version)

Continuous, remote monitoring and logging of electromagnetic fields

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

OPTICAL FIBER repeaters/ isolators

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

WinProladder software package

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

ESP 20/20. Compressor Monitoring System

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Electronic Control Devices The European Product Catalogue 2007

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

RACKS CLASSIC G4 SPEC. DATA SHEET page 1/5. Description. Features

emobility WAGO Leading the Charge

CP SIMATIC NET. S Telecontrol CP Preface. Application and properties. Displays and connectors 2

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Permissible ambient temperature Operation Storage, transport

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Transcription:

77 1.7 Accessories for Saia PCD programmable controllers 1.7.1 I/O-module integration into switching cabinet The way to achieve convenient and fast integration of the I/O-modules into the switching cabinet is to use the adapters by SBC. I/O-modules with ribbon connections, in particular, can be installed quickly and easily in the switching cabinet. The modules with terminals can also be connected to the adapters using traditional stranded wires. The adapters either are available for galvanic separation of the outputs with relays or as simple I/O-adapters with voltage distribution. System characteristics Available as I/O-terminal adapter or relay interface Relay interface with manual mode Compatible with Saia PCD2 and PCD3 systems For connection with system cable or stranded wire For DIN rail mounting Pluggable ribbon cables with connector at the Saia PCD end Cable for the digital modules with 16 inputs/outputs..e16x..a46x..e16x..a46x..e16x..a46x Terminal adapter for digital inputs/outputs Diameter = 11 mm Length Diameter = 11 mm Length Diameter = 11 mm Length 300 mm 100 mm PCD2.K221 / K223 cable Sheathed, round cable with 32 strands of 0.25 mm² (AWG 24), 34-pole ribbon connector at the PCD end Free, unsheathed 100 m ends at the process end Stranded wires, color-coded Cable length PCD2.K221 = 1.5 m PCD2.K223 = 3.0 m PCD2.K231 / K232 cable Sheathed, round ribbon cable with 34 strands of 0.09 mm², 34-pole ribbon connector at both ends Cable length PCD2.K231 = 1.0 m PCD2.K232 = 2.0 m PCD2.K241 / K242 cable Sheathed, round ribbon cable with 34 strands of 0.09 mm², 34-pole ribbon connector at the PCD end Process end divided into 2 branches, each 300 mm in length, leading to 16-pole ribbon connectors Cable length PCD2.K241 = 1.0 m PCD2.K242 = 2.0 m Automation stations Cabinet 5 4 3 2 1 components Consumption acquisition data Dedicated room controller HMI and operating Visualization

78 1.7.1 I/O-module integration into switching cabinet To facilitate and speed up the installation of controllers, various adapters are offered which can be directly connected with the Saia PCD I/O-modules via system cables. Apart from terminal adapters, there are also relay interfaces available which enable simple galvanic separation. The relay interfaces can be connected with ribbon cables or with stranded wires. Terminator adapter for I/O-modules with ribbon connection Mechanical layout Ribbon connector (to the PCD) LED status Screw terminals Process end Terminal adapter for 8 inputs/outputs Terminal adapter PCD2.K51x 16-pole ribbon connector at the PCD end Process end 2 6 Screw terminals 0.5 1.5 mm² PCD2.K510 without LEDs PCD2.K511 with LEDs (source operation) For DIN rail mounting Terminal adapter for 16 inputs/outputs Source adapter PCD2.K520 / K521 34-pole ribbon connector at the PCD end Process end 2 10 screw terminals 0.5 1.5 mm² PCD2.K520 without LEDs PCD2.K521 with LEDs (source operation) Dimensions: 42 82 60 mm (B H T) Terminal adapter for 16 inputs/outputs Terminal adapter PCD2.K525 34-pole ribbon connector at the PCD end Process end 3 16 screw terminals 0.5 1.5 mm² with LEDs (source operation) Dimensions: 65 82 60 mm (B H T) Dimensions: 94 82 72 mm (B H T) Adapter relay interface Adapter relay interface Relay interface PCD2.K551 for 8 PCD transistor outputs with 24 screw terminals and LED Switching capacity of the changeover contacts 10 A / 250 VAC or 10 A / 24 VDC (ohmic), 24 VDC spool 16-pole ribbon connector or screw terminals at the PCD end 24 screw terminals 0.5 1.5 mm² at the process end Mechanical data Diameter of the screw terminals: M2.6 mm Starting torque: 0.4 Nm Relay interface PCD2.K552 for 8 PCD transistor outputs with 24 screw terminals, LED and manual operation mode (switch on-offauto) and 1 output as feedback for the manual mode Switching capacity of the changeover contacts 10 A / 250 VAC or 10 A / 24 VDC (ohmic), 24 VDC spool 16-pole ribbon connector or screw terminals at the PCD end 24 screw terminals 0.5 1.5 mm² at the process end Mechanical data Diameter of the screw terminals: M2.6 mm Starting torque: 0.4 Nm Dimensions: 128 82 55 mm (B H T) Dimensions: 128 82 44 mm (B H T)

79 1.7.2 External modems for top-hat rail installation With state-of-the-art telecommunications combined with the Saia PCD, customers can not only save costs in commissioning and maintenance, but also increase the security, availability and profitability of a system. To achieve this, external modems which enable wired as well as wireless communication are available alongside the Ethernet connections of the controllers. Automation stations System properties Remote support upon commissioning Event or time-driven information and requests to operations and support staff Fault clearance with remote diagnostics Process optimization with software updates and/or updates to process parameters Efficient preventive maintenance by qualified specialists, giving lower repair costs Remote user support for operations directly on the screen Telecommunications setup External analog modem External ISDN modem Analog, ISDN or GSM modem GSM modem integrated into the PCD3.WAC Saia PCD3 Accessories H External GSM antenna PCD7.K830: Antenna for GSM modem B Q.G736-AS2 Cable connection external modem / PC Q.VM-09SAS / 18: RS-232 interface cable Technical data GSM modem Analog modem ISDN modem Q.G736-AS2 Q.M716-KS1 Q.T726-RS1 Interface speed 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600 and 115,200 bps, autobauding Interface V24 (RS-232), D-Sub 9 poles Instruction set Extended AT instruction set Frequency band Dual band GSM 900 and GSM 1800 --- SIM interface SIM card: 3V, drawer --- Transmission standards 2,400 (V.22bis / V.110), 4,800 (V.32 / V.110), 9,600 (V.32 / V.110), 14,400 (V.34 / V.110) bps ITU standards: V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, Bell 103, Bell 212A Dimensions: 45 76 120 mm (B H T) ITU standards: X.75, V.110, V.120 Dialing procedure --- DTMF (multi-frequency) Telephone line RJ-11 and screw terminals for La --- + Lb RJ-45 (ISDN 4-wire) Antenna connector FME-m --- Voltage supply --- 24 VDC +15%, 30% --- T Cabinet 5 4 3 2 1 components Consumption acquisition data Dedicated room controller HMI and operating Visualization

80 1.7.4 Saia upgrade kit The Saia module makes it possible to connect existing Saia PCD4 I/O-modules to the latest Saia PCD3 and PCD2.M5 systems. By upgrading to the latest Saia PCD system, you can increase the availability and reliability of the system. It is also possible to enhance systems with Automation Server functions and thus prepare them for the future. Installation is easy: Replace Saia PCD4 CPU with, install Saia PCD3 or PCD2 CPU, connect new or existing PCD4 I/Os and you re done. Regardless of whether IL or FUPLA programming is used, the user programs can be directly transferred to new CPUs with small program adjustments in PG5, i.e., minimum programming effort. System overview System properties PCD2.M5_ PCD2.K106 PCD4 E/As Supports Saia PCD3.Mxxx0 and Saia PCD2.M5xx0 Program can be easily transferred Existing I/Os can still be used PCD3.M_ PCD3.C200 PCD3.K1x6 Features Increase system availability with a minimum of effort: Replace old PCD4 CPUs that are no longer available with the latest Saia PCD CPUs. The reliability and availability of an existing system or controller can be increased in a time-saving manner and cost-efficiently by using a new CPU. Benefits of the Automation Server functions: New Web/IT functions can also be made available in existing systems with PCD4 systems. Existing program structures can be copied across with small program adjustments and can still be used. Add new PCD2/3 I/O-modules to PCD4 systems. Up to 8 additional PCD2/3 I/O-modules can be integrated into existing systems by replacing the CPUs. Retaining the wiring: The system can be upgraded without costly rewiring of the I/Os. Short upgrade period: The CPU is replaced quickly and the system will be available again in a very short period of time. This way the wiring effort can be delayed to a later point in time. Technical overview Supported PCD types Supported PCD4 I/O-modules Number of PCD4 I/O-modules Max. number of PCD2/3 I/O-modules PCD3.Mxxx0 All PCDs with I/O-bus connection PCD2.M5xx0 (no extension PCD2.C1000/C2000) All PCD4 I/O-modules except PCD4.Hx are supported See technical documentation of the PCD4 systems 8 (only PCD2.C200 module carriers can be used in combination with the PCD3.M system) Order details Type PCD3.K106 PCD2.K106 Description PCD4 upgrade kit basic module (without I/O-bus cable) I/O-bus extension cable for Saia PCD3 I/O-bus extension cable for Saia PCD2

81 1.7.4 Saia upgrade kit Once it has been clarified whether all I/O-modules are suitable for upgrading, installation is really easy: Replace Saia PCD4 CPU with, install Saia PCD3 or PCD2 CPU, connect new or existing PCD4 I/Os. Automation stations 1. Insert module The existing PCD4 CPU is completely removed. To continue to ensure I/O-bus supply, the PCD4 supply module will still be used. The new module is used instead of the PCD4 CPU. The existing power supply module PCD4.N2x0 must have at least the hardware version B. 2. Connect PCD2.M5_ or PCD3.M_ The new PCD CPU is connected to the module with the I/O-bus cable. For PCD2.M5xxx: PCD2.K106. For PCD3.Mxxxx: PCD3.K116 or PCD3.K106. 3. SERIAL INTERFACES None of the PCD4 serial interfaces are supported. They must all be replaced with new PCD2/3 interfaces. Maximum of 3 integrated serial interfaces on the PCD3. Maximum of 4 integrated serial interfaces on the PCD2. Additional upgrade option with PCD3.F1xx or PCD3.F2xx/PCD2.F2xxx*. 4. Programming with PG5 Transfer user program to PG5, adjust programs, download and you re done. Detailed descriptions of the individual steps are listed in the manual. PCD2.M5_ PCD3.M_ PCD4 I/Os PGU RS-232 S-Net/MPI 2 PCD7.F1xxS * Additional serial interfaces can be implemented via SPI I/O-slots. However, the I/O-address range will shift as a result. See the manual 26/888 for further details. S-Net MPI PGU RS-485 RS-232 Cabinet 5 4 3 2 1 components Consumption acquisition data Dedicated room controller HMI and operating Visualization

82